• Title/Summary/Keyword: Immediate implants

Search Result 181, Processing Time 0.023 seconds

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

Clinical Evaluation about the Immediate Implant Replacement after Tooth Extraction (발치 직후 시행된 즉시 임플란트 식립술에 관한 임상적 평가)

  • Yang, Eun-Young;Chun, Sang-Deuk;Rho, Jae-Hwan;Lee, Seung-Eun;Song, Jae-Chul;Chin, Byung-Rho
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • Background: Immediate implant placement has become an acceptable treatment for the edentulous area. The advantages of the immediate implant placement include considerable decrease in time from tooth extraction to placement of the finial prosthesis, fewer surgical procedures, and better acceptance of the overall treatment plans. But the success is dependent on the quantity and quality of the extraction socket. The purpose of this study is to evaluate the success of the immediate implant placement. Materials and Methods: Twenty-one sites in 16 patients were selected for the evaluation of the immediate implant placement. All of the cases were followed using clinical and radiographic examinations. Criteria of success were the absence of peri-implant radiolucency, mobility, and persistent pain or sign of infection. Results: Of the 21 implants, 13 implants have been succeeded. Of the 13 implants, 10 implants were replaced for the periodontal disease and 3 implants were replaced for the trauma. Conclusion: The criteria of the success in immediate implant placement are as follows. 1) Implants placed into fresh extraction sockets have a high rate of survival. 2) Implant should be placed as close as possible to the alveolar crest. 3) Implant placed into available bone beyond the apex have a high success rate.

  • PDF

The feasibility of immediately loading dental implants in edentulous jaws

  • Henningsen, Anders;Smeets, Ralf;Wahidi, Aria;Kluwe, Lan;Kornmann, Frank;Heiland, Max;Gerlach, Till
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.234-243
    • /
    • 2016
  • Purpose: Immediate loading of dental implants has been proved to be feasible in partially edentulous jaws. The purpose of this retrospective investigation was to assess the feasibility of immediately loading dental implants in fully edentulous jaws. Methods: A total of 24 patients aged between 53 and 89 years received a total of 154 implants in their edentulous maxillae or mandibles. Among the implants, 45 were set in fresh extracted sockets and 109 in consolidated alveolar bones. The implants were provisionally managed with chair-side made provisional resin bridges and exposed to immediate loading. Implants were followed up for 1-8 years, including radiographic imaging. Marginal bone levels were evaluated based on radiographic imaging. Results: A total of 148 out of the 154 implants survived over the follow-up period of 1 to 8 years, giving a survival rate of 96%. The time or region of the implantation, the pre-implant augmentation, and the length and diameter of the implants had no statistically significant influence on the survival or the success rate. The marginal bone level remained stable with only minimal loss of 0.3 mm after 60 months of loading. Conclusions: Within the limitations of this study, immediate loading is feasible for dental implants in edentulous jaws.

COMPARATIVE STUDY ON THE MARGINAL BONE LOSS OF IMMEDIATE NONSUBMERGED AND SUBMERGED ENDOSSEOUS DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKETS OF DOGS (발치후 즉시 매식한 Nonsubmerged와 Submerged 임플랜트의 변연골 흡수양상에 관한 비교연구)

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.255-264
    • /
    • 1997
  • The conventional osseointegration protocol calls for waiting up to 12 months for ossification of an extraction socket to heal before placing an endosseous implant. In this study, the possibility of placing a pure titanium implant directly into an extraction socket immediately after extraction was investigated. And the marginal bone loss of immediate nonsubmerged and submerged endosseous dental implants placed into extraction sockets was also compared. Pure titanium Nobelpharma Branemark implants and solid screw type ITI implants were placed into premolar extraction sockets of two adult dogs and allowed to heal for a period of 3 months, followed by functional loading of the implant. Radiographic examination was performed before implantation, immediately after implantation and 3, 6, 9, 12 months after implantation. The results obtained were as follows : 1. Immediately placed nonsubmerged ITI implants and submerged Branemark implants showed favorable radiographic osseointegration status and there were minimum marginal bone loss. 2. There were no significant differences in radiographic finding of osseointegration between conventional and immediate implantation. 3. Gingival tissue around implants showed more inflammatory signs than that of adjacent natural teeth. This study suggest that pure titanium Branemark implants and submerged ITI implants have the potential to integrate when placed immediatly after extraction of the teeth and warrants further investigation.

  • PDF

Guidance and rationale for the immediate implant placement in the maxillary molar

  • Kezia Rachellea Mustakim;Mi Young Eo;Ju Young Lee;Hoon Myoung;Mi Hyun Seo;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.1
    • /
    • pp.30-42
    • /
    • 2023
  • Objectives: While the reliability of immediate implant placement in the maxillary molar has been discussed, its significance is questionable. There have been no guidelines for case selection and surgical technique for successful treatment outcomes of immediate maxillary molar implants. Therefore, in this study, we classified alveolar bone height and socket morphology of the maxillary molar to establish guidelines for immediate implant placement. Materials and Methods: From 2011 to 2019, we retrospectively analyzed 106 patients with 148 immediate implants at the Department of Oral and Maxillofacial Surgery, Seoul National University Dental Hospital. Inclusion and exclusion criteria were applied, and patient characteristics and treatment results were evaluated clinically and radiologically. Results: A total of 29 tapered, sand-blasted, large-grit, and acid-etched (SLA) surfaces of implants were placed in 26 patients. The mean patient age was 64.88 years. Two implants failed and were reinstalled, resulting in a 93.10% survival rate. Fluctuating marginal bone level changes indicating bone regeneration and bone loss were observed in the first year following installation and remained stable after one year of prosthesis loading, with an average bone loss of 0.01±0.01 mm on the distal side and 0.03±0.03 mm on the mesial side. Conclusion: This clinical study demonstrated the significance of immediate implant placement in maxillary molars as a reliable treatment with a high survival rate using tapered SLA implants. With an accurate approach to immediate implantation, surgical intervention and treatment time can be reduced, resulting in patient satisfaction and comfort.

An 8-year survival rate of immediate implants: retrospective study (발치후 즉시 임플란트의 8년 누적 생존율에 대한 후향적 연구)

  • Ko, Seung-Hee;Chang, Yun-Young;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.47 no.11
    • /
    • pp.758-768
    • /
    • 2009
  • Purpose : Schulte introduced immediate implant cases in 1970s, since then many patients have been treated by immediate implants. The aim of this study was to evaluate the cumulative survival rate of immediate implant and to analyze various factors associated with survival of immediate implant in a 8-year period retrospectively. Materials and methods : From May, 2000 to October, 2007, 77 implants were placed in 63 patients immediately after tooth extraction at Department of Periodontology, Yonsei University Hospital. The implant survival rate was analyzed using a life-table analysis. After delivery of prosthesis, along 1 year of observation period, all implants were evaluated clinically and radiographically. Results : Among 77 implants, 59 were placed in maxilla and 18 in mandible. The most common site of the implantation was Mx anterior (65%). The overall survival rate was 94.8% over a mean follow-up period of $44.2{\pm}21$ months and the 8-year cumulative survival rate was 94.6%. Failure occurred in 4 implants, all of which were due to early failures. None of the following factors were significantly associated with the survival of immediate implants: advanced surgical technique including bone graft and guided bone regeneration, the types of implants, causes of tooth loss, and types of prosthesis. Conclusion : On the basis of 8-year life time analysis, immediate implant placement can be considered a safe and predictable treatment mordality.

  • PDF

A STUDY OF MARGINAL BONE RESORPTION AROUND IMPLANTS AFTER IMMEDIATE LOADING (Immediate loading하에서 치근형 임프란트 주위 변연골 흡수에 대한 연구)

  • Kim Sung-Hyen;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.376-390
    • /
    • 2001
  • Alveolar bone changes after immediate loading on implants up to one year were observed by means of standard intraoral X-ray measurement which were taken at 3 month intervals. At the same time, bone density changes were observed according to digital subtraction method which is a becoming a more and more promising diagnostic tool for implants. Following results were obtained ; 1. There was no significant difference in the amount of alveolar bone loss implant type, sex and implant diameter, but there was difference according to case selection. In fully bone anchored prostheses cases, bone loss was $1.16{\pm}0.15m$ whereas, in partial edentulous cases, it was $1.84{\pm}0.08mm$. 2. Alveolar bone loss after immediate loading showed a higher degree of bone loss than after submerged loading in the initial three months. But there were no significant difference at the 12th month. 3. According to the one year bone density change observation at the alveolar bone surrounding the implant, significant change was observed vertically, whereas no significant change could observed horizontally. According to the above mentioned results, we can conclude that immediate loading of implants results in a higher degree of alveolar bone loss in one year than submerged loading. But since alveolar bone loss rate decreases to a reasonable rate after the initial 3 months of rapid bone loss, immediate loading of implants seems to be an acceptable treatment modality for patients with good bone conditions. Fully bone anchored cases showed an favorable outcome, but partial edentulous cases showed more bony resorption. So this cases considered in case selections. Bone density changes observation in the study was performed for only one year therefore a more longitudinal observation may be studied.

  • PDF

MULTICENTER RETROSPECTIVE STUDY OF IMMEDIATE TWO DIFFERENT RBM SURFACED IMPLANT SYSTEMS AFTER EXTRACTION (발치 후 즉시 매식된 서로 다른 두종의 RBM표면 처리된 임플란트에 대한 다기관 후향적 임상연구)

  • Park, Hong-Ju;Kook, Min-Suk;Kim, Su-Gwan;Kim, Young-Kyun;Cho, Yong-Seok;Choi, Gab-Lim;Oh, Young-Hak;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.258-265
    • /
    • 2008
  • Purpose. This multicenter retrospective study was performed to evaluate the survival and success rates of immediate placement of USII and SSII Osstem implant (Osstem implant Co, Korea) on the maxillary and mandibular anterior and premolar areas. Materials and methods. Dental records were obtained in 37 patients who were treated with immediate implantation on the maxillary and mandibular anterior and premolar areas in 6 different clinics. The 98 implants were evaluated both clinically and radiographically using predefined success criteria. Results. There was no failed implant in all patients. The mean follow up period was 24.7 months (ranged from 12 to 58 months), and 25.1 months (ranged from 16 to 35 months) in USII and SSII implants, respectively. The crestal bone loss was 3 mm in 3 USII implants during 41 months, and in 1 SSII implant during 22 months. The overall success rate was 94.2% and 97.7% in USII and SSII implants, respectively. The age, gender, diameter, or length of implants, and type of surgery were not influenced to the success rate of immediate implantation. Conclusion. These results suggest that USII and SSII Osstem implant can be used successfully in immediate implantation on the maxillary and mandibular anterior and premolar areas.