• Title/Summary/Keyword: Immediate fixation group

Search Result 28, Processing Time 0.026 seconds

STABILITY OF TWO-JAW SURGERY FOR MANDIBULAR PROGNATHISM (하악전돌증 환자에 대한 양악 수술의 안정성)

  • Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.4
    • /
    • pp.348-356
    • /
    • 2001
  • The factors related to relapse in 20 skeletal class III patients who performed two-jaw surgery with Le Fort I maxillary osteotomy and bilateral sagittal split ramus osteotomy was investigated. All patients were fixed with miniplate on the maxilla and three screws at each mandible. Cephalograms taken at preoperative, immediate postoperative and 8 months postoperative after surgery were traced and digitized. 1.The horizontal and vertical relapse of maxilla and mandibular chin points was within 1mm postoperatively. Compare to the preceding report concerning the mandibular set-back surgery only group, this reveals two-jaw surgery for mandibular prognathism using rigid fixation is more stable. 2.Although there was no significant relapse tendancy was observed at chin points, the screw tip land-marks moves anterio-superiorly and each side of the screws moved as a one unit. The screw tip points moved similar direction to the masticatory force and this movements might be influenced by the muscular tension to the distal segment of the mandible. 3.According to the regression analysis, the amount of horizontal and vertical movement of mandibular set-back influenced the mandibular relapse. However, direction and amount of maxillary surgical movement did not inf1uenced the maxillary and mandibular relapse.

  • PDF

MORPHOLOGIC AND POSITIONAL CHANGE OF THE PROXIMAL SEGMENTS AFTER INTRAORALVERTICAL RAMUS OSTEOTOMY OF THE MANDIBULAR PROGNATHISM ON SUBMENTOVERTEX CEPHALOGRAM (하악골 전돌증환자의 구내 하악골상행지 수직골절단술후 이하두정 계측방사선사진상에서의 근심골편의 형태 및 위치 변화)

  • Chung, Jae-Hyung;Park, Hyung-Sik;Hwang, Chung-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.26-34
    • /
    • 2003
  • Intraoral Vertical Ramus Osteotomy,along with Sagittal Split Ramus Osteotomy,is an popular surgical technique performed on mandibular prognathism. However Intraoral Vertical Ramus Osteotomy has been suspected for an initial mobilization at the healing phase of segment because it does not employ the rigid fixation between segments. To execute a study on the healing phase of segment after Intraoral Vertical Ramus Osteotomy on the horizontal plane, 102 patients (204 parts) who were diagnosed mandibular prognathism and took Intraoral Vertical Ramus Osteotomy at the Yonsei University dental hospital were observed during the period of before operation, immediately postoperation, 1 month, 3 months, 6 months, and 12 months. The change in the width of segment and horizontal angle of proximal segment and condylar head on the Submentovertex Cephalogram taken from those patients represented following results. 1. The width of proximal and distal segment decreased with the lapse of time. It decreased into 84.5% between immediate postoperative and 6M and even continued to decrease till 12M. 2. The horizontal angle of the proximal segment did medial rotation according as the lapse of time and rigorously continued till 3M. The rotation angle of condylar head indicated its tendency of recurrence to the original position but the entire recurrence was not allowed. The bigger an initial angle was, the higher was the tendency of recurrence after the operation while the rotation angle remained still bigger. 3. After grouping into group 1, group 2,and group 3 based on the extent of the variation of rotation angle of condylar head at immediate postoperative, the variation of rotation angle was measures in each group. The result presented that the initial rotation angle of condylar head had correlation with that of proximal segment but had no relation with the extent of setback of the mandible. However a quantitative analysis alone is not a sufficient method for analyzing the healing phase of segment on the horizontal plane.Therefore a multilateral analysis using 3 dimensional data such as CT is recommendable for the future study.

Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients (요추전방전위증 환자들에서 후방요추체간유합술로 자가골편 또는 Cage를 사용한 두 군간의 비교)

  • Shin, Pill Jae;Kim, Chang Hyun;Moon, Jae Gon;Lee, Ho Kook;Hwang, Do Yun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : Posterior lumbar interbody fusion(PLIF) with transpedicular screw fixation(TPSF) have many merits in the treatment of spondylolisthesis. The aim of this study was to compare cage PLIF group(PLIF using cage and TPSF) with chip PLIF group(PLIF using autologous bone chips and TPSF) as surgical treatment of spondyloisthesis. Methods : PLIF and TPSF were performed in 44 patients with spondylolisthesis from January 1994 to December 1998. The surgical methods were divided into two groups. One group was cage PLIF(20 patients), and the other group was chip PLIF(24 patients). We analyzed the change of anterior translation, change of intervertebral space height, fusion rate, clinical outcomes, and postoperative complications in two groups. Result : There was no significant difference in reduction and maintenance of anterior translation between two groups. Intervertebral space height was increased in the two groups at immediate postoperative state. At last followup, it was decreased compared to preoperative height in chip PLIF group. In cage PLIF group, last follow-up height was decreased compared to immedate postoperative height, but it was significantly increased compared to preoperative height. Fusion rates were 70.9% and 90% in chip PLIF group and cage PLIF group, respectively. Excellent and good clinical outcomes were 79.2% in chip PLIF group and 85% in cage PLIF group, but there was no statistical significance. Complications were screw fracture(1 case), CSF leakage(1 case) in chip PLIF group and screw loosening and retropulsion of cage(1 case), CSF leakage(2 cases) in cage PLIF group. Conclusion : PLIF using cage is better than PLIF using autologous bone chips in the maintenance of intervertebral space height and fusion rate. But there is no statistical difference of the clinical outcomes between the two groups. Further studies, especially on long term follow-up, should be considered.

  • PDF

Correction of Spondylolisthesis by Lateral Lumbar Interbody Fusion Compared with Transforaminal Lumbar Interbody Fusion at L4-5

  • Ko, Myeong Jin;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.422-431
    • /
    • 2019
  • Objective : In an aging society, the number of patients with symptomatic degenerative spondylolisthesis (DS) is increasing and there is an emerging need for fusion surgery. However, few studies have compared transforaminal lumbar interbody fusion (TLIF) and lateral lumbar interbody fusion (LLIF) for the treatment of patients with DS. The purpose of this study was to investigate the clinical and radiological outcomes between TLIF and LLIF in DS. Methods : We enrolled patients with symptomatic DS at L4-5 who underwent TLIF with open pedicle screw fixation (TLIF group, n=41) or minimally invasive LLIF with percutaneous pedicle screw fixation (LLIF group, n=39) and were followed-up for more than one year. Clinical (visual analog scale and Oswestry disability index) and radiological outcomes (spondylolisthesis rate, segmental sagittal angle [SSA], mean disc height [MDH], intervertebral foramen height [FH], cage subsidence, and fusion rate) were assessed. And we assessed the changes in radiological parameters between the postoperative and the last follow-up periods. Results : Preoperative radiological parameters were not significantly different between the two groups. LLIF was significantly superior to TLIF in immediate postoperative radiological results, including reduction of spondylolisthesis rate (3.8% and 7.2%), increase in MDH (13.9 mm and 10.3 mm) and FH (21.9 mm and 19.4 mm), and correction of SSA ($18.9^{\circ}$ and $15.6^{\circ}$) (p<0.01), and the changes were more stable from the postoperative period to the last follow-up (p<0.01). Cage subsidence was observed significantly less in LLIF (n=6) than TLIF (n=21). Fusion rate was not different between the two groups. The clinical outcomes did not differ significantly at any time point between the two groups. Complications were not statistically significant. However, TLIF showed chronic mechanical problems with screw loosening in four patients and LLIF showed temporary symptoms associated with the surgical approach, such as psoas and ileus muscle symptoms in three and two cases, respectively. Conclusion : LLIF was more effective than TLIF for spondylolisthesis reduction, likely due to the higher profile cage and ligamentotactic effect. In addition, LLIF showed mechanical stability of the reduction level by using a cage with a larger footprint. Therefore, LLIF should be considered a surgical option before TLIF for patients with unstable DS.

EVALUATION OF CONDYLAR DISPLACEMENT USING COMPUTER TOMOGRAPHY AFTER THE SURGICAL CORRECTION OF MANDIBULAR PROGNATHISM (전산화단층촬영법을 이용한 하악전돌증 환자의 외과적 악교정술후 하악과두 위치 변화 검토)

  • Lee, Ho-Kyung;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.3
    • /
    • pp.191-200
    • /
    • 1998
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after orthognathic surgery in 37 patients(male 13, female 24) using computed tomogram that were taken in centric occlusion before, immediate after, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period of intermaxillary fixation, at the 24 hours later removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.42{\pm}5.30mm$ and horizontal long axis of condylar angle was $12.79{\pm}4.92^{\circ}$ on the right, $13.53{\pm}5.56^{\circ}$ on the left side. Condylar lateral poles were located about 12mm and medial poles about 7mm away from the reference line(AA') on the axial tomogram. Mean intercondylar distance was $83.15{\pm}4.62mm$ and vertical axis angle of condylar angle was $76.28{\pm}428^{\circ}$ on the right, $78.30{\pm}3.79^{\circ}$ on the left. 2. In amount of set back, We found the condylar change(T2C-T1C) which had increasing tendency in group III (amount of setback : 10-15mm). but there was no statistical significance(p>0.05). 3. There was some correlation between condylar change(T2C-T1C) and TMJ dysfunction. It seemed that postoperative condylar change had influenced postoperative TMJ dysfunction, through there was no statistical significance (p>0.05). As we have observed the change of condylar axis in the group that complained of TMJ dysfunction in cases of large amount of mandibular setback. So we consider that the more trying to conserve condylar position will decrease occurrence rate of post operational TMJ dysfunction.

  • PDF

A comparative study on the change of postoperative facial hard tissue profile after maxillary rotational surgery (하악전돌증 환자의 양악 수술 시 상악골 후상방 회전이동 여부에 따른 안면부 경조직 변화량에 대한 비교 연구)

  • Kim, Uk-Kyu;Lee, Sung-Tak;Kim, Tae-Hoon;Song, Jae-Min;Hwang, Dae-Seok;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.264-271
    • /
    • 2011
  • Purpose: This study evaluated retrospectively the postsurgical facial hard tissue profile of a Le Fort I osteotomy with/without posterior impaction and rigid internal fixation to correct mandibular prognathism. After observing a difference between the two groups, this measurement was used to prepare a treatment plan for 2-jaw surgery. Patients and Methods: Thirty patients who had undergone orthognathic surgery in Pusan National University Dental Hospital were enrolled in this study. Fifteen patients were treated using a Le Fort I osteotomy with posterior impaction and mandibular setback bilateral sagittal split ramus osteotomy, and the other fifteen patients were treated without posterior impaction. The preoperative (T0), immediate postoperative (T1) and six-month follow-up period (T2) cephalograms were taken and difference between T1-T0 and T2-T2 was analyzed. Results: Both groups was FH-ABp, SNB and ANB showed significant changes in the measurement, whereas only the posterior impaction group showed a change in the SN-U1, occlusal plane, posterior facial height, surgical movement difference from the L1 and B-point. There was no significant statistical change between the immediate postoperative (T1) and six-month follow-up (T2) hard tissue analysis in the two groups. Conclusion: A Le Fort I osteotomy with posterior impaction is considerable for patients with a flat occlusal plane angle, large posterior facial height, prominent B-point, pogonion and labioversed incisal inclination if the indications are well chosen.

Analysis of the Risk Factors for Unfavorable Radiologic Outcomes after Fusion Surgery in Thoracolumbar Burst Fracture : What Amount of Postoperative Thoracolumbar Kyphosis Correction is Reasonable?

  • Seo, Dong Kwang;Kim, Chung Hwan;Jung, Sang Ku;Kim, Moon Kyu;Choi, Soo Jung;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.96-105
    • /
    • 2019
  • Objective : The aims in the management of thoracolumbar spinal fractures are not only to restore vertebral column stability, but also to obtain acceptable alignment of the thoracolumbar junction (T-L junction) to prevent complications. However, insufficient surgical correction of the thoracolumbar spine would be likely to cause late progression of abnormal kyphosis. Therefore, we identified the surgical factors that affected unfavorable radiologic outcomes of the thoracolumbar spine after surgery. Methods : This study was conducted in a single institution from January 2007 to December 2013. A total of 98 patients with unstable thoracolumbar spine fracture were included. In these patients, fixation was done through transpedicular screws with rods by three surgical patterns. We reviewed digital radiographs and analyzed the images preoperatively and postoperatively during follow-up visits to compare the change of the thoracolumbar Cobb angle with radiologic parameters and clinical outcomes. The unfavorable radiologic group was defined as the patients who were measured as having greater than 20 degrees of thoracolumbar Cobb angle on the last follow-up, or who underwent kyphotic progression of thoracolumbar Cobb angle greater than 10 degrees from the immediate postoperative state to final follow-up, or who had overt instrument failure with/without additional surgery. We assessed the risk factors that affected the unfavorable radiologic outcomes. Results : We had 43 patients with unfavorable radiologic outcomes, including 35 abnormal thoracolumbar alignments and 14 instrumental failures with/without additional surgery. The multivariate logistic regression test showed that immediate postoperative T-L junction Cobb angle less than 10.5 degrees was a statistically significant risk factor, as well as the presence of osteoporosis (p=0.017 and 0.049, respectively). Conclusion : Insufficient correction of thoracolumbar kyphosis was considered to be a major factor of an unfavorable radiological outcome. The spinal surgeon should consider that having a T-L junction Cobb angle larger than 10.5 degrees immediately after surgery could result in an unfavorable radiological outcome, which is related to a poor clinical outcome.

AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING (임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향)

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).