• Title/Summary/Keyword: Imaging thermography

Search Result 91, Processing Time 0.032 seconds

Panorama Image Processing for Condition Monitoring with Thermography in Power Plant (공업플랜트의 상태감시를 위한 열화상 파노라마 이미지 처리기법 연구)

  • Jeon, Byoung-Joon;Kim, Tae-Hwan;Kim, Soon-Geol;Mo, Yoon-Syub;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.98-103
    • /
    • 2010
  • In this paper, imaging processing study obtained from CCD image and thermography image was performed in order to treat easily thermographic data without any risks of personnels who conduct the condition monitoring for the abnormal or failure status occurrable in industrial power plants. This imaging processing is also applicable to the predictive maintenance. For confirming the broad monitoring, a methodology producting single image from the panorama technique was developed no matter how many cameras are employed, including fusion method for discrete configuration for the target. As results, image fusion from quick realtime processing was obtained and it was possible to save time to track the location monitoring in matching the images between CCTV and thermography.

MRI의 현황과 전망

  • 전희국
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.125-130
    • /
    • 1988
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of $0.1^{\circ}C$ under the spatial resolution of lmrad, the image matrix size of $256 {\times} 240, $ and tile imaging time of 4 seconds.

  • PDF

Realization of Optic Systems for the Infrared Thermography (적외선 체열촬영시스템을 위한 광학계의 구성)

  • Lee, Soo-Yeol;Woo, Eung-Je;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.1
    • /
    • pp.97-104
    • /
    • 1994
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensionaloptic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the infrared thermography system composed ofthe proposed optic system has the temperature resolution of $0.1{\circ}C$ under the spatial resolution of 1mrad, the image matrix size of $256{\times}240$, and the imaging time of 4 seconds.

  • PDF

The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography (적외선 열화상을 이용한 비파괴시험 활용 및 결함 진단)

  • Choi, Man-Yong;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.5
    • /
    • pp.525-531
    • /
    • 2004
  • In this paper, the concept of infrared thermography(IRT), the principle of measurement of IRT and how to set up the IR camera for the nondestructive testing are described in detail. Also, its utilization and non-destructive testing(NDT) diagnosis are reviewed. By performing the periodic non-touched WDT through the estimation of thermal patterns related with the temperature for the surface targeted, IRT can be applied to the early prevention of the device failure. For the diagnosis utilization, thermal imaging patterns obtained from IRT for heated blocks with internal defects were estimated through the lion-destructive method and discussed the way of IRT estimation from the analysis of characteristics between material defects and thermal imaging patterns.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Effects of Hyeong points' Acupuncture of Three Foot-eum Collaterals on Abdominal Thermography of Healthy Human Beings (족삼음경(足三陰經) 형혈(滎穴) 자침(刺鍼)이 흉복부(胸腹部)의 체열변화(體熱變化)에 미치는 영향(影響))

  • Shin Jong-Keun;Kim Jae-Hyo;Park Sung-Sub;Park Kui-Jong;Kim Kyung-Sik;Sohn In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.20 no.4
    • /
    • pp.1-16
    • /
    • 2003
  • Objectives : This study was examined for effects of acupuncture of Hyeong points' Acupuncture of Three Foot-eum Collaterals on the abdominal thermography of health subject. Methods : The volunteers who participating in this study had taken rest for 20 - 30 minutes in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 minutes before, just before and 15 minutes after, 30 minutes after and 45 minutes after acupuncture stimulation. Acupuncture was applied to the left Hyeong points' Acupuncture of Three Foot-eum Collaterals for 30 minutes. Results : The results showed that acupuncture of Hyeong points had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, it was observed that the quantities of thermal changes following acupuncture of Hyeong points been increased comparing that of control group at all the ROIs (region of interest). Observed the thermography classified by ROI, however, it was failed that acupuncture of Hyeong points could modulate the specific areas concerning to the abdominal pathway of Three Foot-eum Collaterals. Conclusions : These results suggest that acupuncture of Hyeong points may modulate thermal distributions and changes of abdominal areas including the below of chest.

  • PDF

Predicting lipoabdominoplasty complications with infrared thermography: a delta-R analysis

  • Resende, Patricia Rodrigues;Brioschi, Marcos Leal;Meneck, Franciele De;Neves, Eduardo Borba;Teixeira, Manoel Jacobsen
    • Archives of Plastic Surgery
    • /
    • v.48 no.5
    • /
    • pp.553-558
    • /
    • 2021
  • The diagnosis of the main complications resulting from lipoabdominoplasty has not yet been standardized. Infrared thermal imaging has been used to assess possible complications, such as necrosis and changes in micro- and macro-circulation, based on perforator mapping techniques, among others. The objective of this study was to present two clinical cases involving thermal imaging monitoring of the healing process of lipoabdominoplasty in the immediate postoperative evaluation and its preliminary results. Infrared thermography was performed 24 hours after the operation and on postoperative days 5, 25, and 27. In clinical case 1, it was found that the delta-R (∆TR)-defined as the difference in minimum temperature between the highest and lowest points in the SA3 region (caution suction area) following the classification established by Matarasso-was 0.4℃ at 24 hours after surgery and decreased to 0.1℃ on a postoperative day 5. There were no complications in this case. In contrast, in clinical case 2, the ∆TR was 1.7℃ at 24 hours after surgery (upon hospital discharge) and remained high, at 2.2℃, on postoperative day 5. A higher ∆TR was found in the second patient, who developed necrosis of the surgical wound. The ∆TR thermal index may be a new tool for predicting possible complications, complementing the clinical evaluation and therapeutic decision-making.

Characteristics of Acupuncture at ST36 on Facial Thermography of Health Subject (족삼리(足三里) (ST36) 자침(刺鍼)이 안면부(顔面部) 한열변화(寒熱變化)에 미치는 영향(影響))

  • Kim Yong-Tae;Kim Jae-Hyo;Hwang Jae-Ho;Kim Kyung-Sik;Sohn In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.13-33
    • /
    • 2002
  • This study was examined for effects of acupuncture of Zusanli (ST36) on the facial thermography in health subjects. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature (23-$25^{\circ}C$) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of face was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 min before, just before and 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to the left ST36 for 30 mins. The results showed that acupuncture of ST36 significantly decreased the temperature of all the areas of facial surface comparing to those of control group. Also, it was observed that the quantities of thermal changes following acupuncture of ST36 been increased significantly at the A1, A4, A6, A7 and A9 ROIs (region of interest) comparing that of control group. Observed the thermography classified by ROI, it was clear the fact that acupuncture of ST36 could modulate the specific areas concerning to the facial pathway of Stomach Meridian, because the thermal responses following acupuncture of ST36 were specific at the A1, A2, A5 and A9 ROIs, relatively. These results suggest that acupuncture of ST36 may modulate thermal distributions and changes of facial areas concerned with Stomach Meridian.

  • PDF

Thermal Imaging for Detection of SM45C Subsurface Defects Using Active Infrared Thermography Techniques (능동 적외선 열화상 기법에 의한 SM45C 이면결함 검출 열영상에 관한 연구)

  • Chung, Yoonjae;Ranjit, Shrestha;Kim, Wontae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.3
    • /
    • pp.193-199
    • /
    • 2015
  • Active thermography techniques have the capability of inspecting a broad range simultaneously. By evaluating the phase difference between the defected area and the healthy area, the technique indicates the qualitative location and size of the defect. Previously, the development of the defect detection method used a variety of materials and the test specimen was done. In this study, the proposed technique of lock-in is verified with artificial specimens that have different size and depth of subsurface defects. Finally, the defect detection capability was evaluated using comparisons of the phase image and the amplitude image according to the size and depth of defects.