• Title/Summary/Keyword: Imaging studies

Search Result 1,627, Processing Time 0.048 seconds

Imaging of a Defect in Thin Plates Using the Time Reversal of Single Mode Lamb Wave: Simulation

  • Jeong, Hyun-Jo;Lee, Jung-Sik;Bae, Sung-Min;Lee, Hyun-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.261-270
    • /
    • 2010
  • This paper presents an analytical investigation for a baseline-free imaging of a defect in plate-like structures using the time-reversal of Lamb waves. We first consider the flexural wave (A0 mode) propagation in a plate containing a defect, and reception and time reversal process of the output signal at the receiver. The received output signal is then composed of two parts: a directly propagated wave and a scattered wave from the defect. The time reversal of these waves recovers the original input signal, and produces two additional side bands that contain the time-of-flight information on the defect location. One of the side band signals is then extracted as a pure defect signal. A defect localization image is then constructed from a beamforming technique based on the time-frequency analysis of the side band signal for each transducer pair in a network of sensors. The simulation results show that the proposed scheme enables the accurate, baseline-free detection of a defect, so that experimental studies are needed to verify the proposed method and to be applied to real structure.

Brain Areas Subserving Torrance Tests of Creative Thinking: An Functional Magnetic Resonance Imaging Study

  • Hahm, Jarang;Kim, Kwang Ki;Park, Sun-Hyung;Lee, Hyo-Mi
    • Dementia and Neurocognitive Disorders
    • /
    • v.16 no.2
    • /
    • pp.48-53
    • /
    • 2017
  • Background and Purpose Torrance Tests of Creative Thinking (TTCT) is a well-known and commonly used measure of creativity. However, the TTCT-induced creative hemodynamic brain activity is rarely revealed. The purpose of this study is to elucidate the neural correlates of creative thinking in the setting of a modified version of the figural TTCT adapted for an functional magnetic resonance imaging (fMRI) experiment. Methods We designed a blocked fMRI experiment. Twenty-five participants (11 males, 14 females, mean age $19.9{\pm}1.8$) were asked to complete the partially presented line drawing of the figural TTCT (creative drawing imagery; creative). As a control condition, subjects were asked to keep tracking the line on the screen (line tracking; control). Results Compared to the control condition, creative condition revealed greater activation in the distributed and bilateral brain regions including the left anterior cingulate, bilateral frontal, parietal, temporal and occipital regions as shown in the previous creativity studies. Conclusions The present revealed the neural basis underlying the figural TTCT using fMRI, providing an evidence of brain areas encompassing the figural TTCT. Considering the significance of a creativity test for dementia patients, the neural correlates of TTCT elucidated by this study may be valuable to evaluate the brain function of patients in the clinical field.

PREPARATION OF N-(3-BROMO-2,4,6-TRIMETHYLACETANILIDE)IMINODIACETIC ACID AND ITS ${99M}^TC$-COMPLEX FOR HEPATOBILIARY IMAGING

  • CHOI OK-JA;HONG YOUNG-DON;GWON HUI-JEONG;CHOI SANG-MU;CHOI SUN-JU
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.391-394
    • /
    • 2005
  • N-(3-bromo-2,4,6-trimethylacetanilide)iminodiacetic acid (BrTIDA) was synthesized using nitrilotriacetic anhydride prepared in situ, and lyophilized vials were prepared which contained 20 mg of BrTIDA and 0.4 mg of $SnCl_2$. To evaluate the clinical efficacy of the in-house prepared lyophilized kit, a technetium-99m complex of BrTIDA was prepared; its in vivo pharmacokinetic behavior was evaluated via animal studies to assess the hepatocytic function and the functional status of the cystic duct and the gallbladder. Serial static image scans of rabbits and the biodistribution in mice injected with $^{99m}Tc-BrTIDA$ revealed that none of the tissues except for the hepatobiliary system showed radioactivity concentrations, and a rapid clearance from the organs was observed. In conclusion, a lyophilized kit and its prepared $^{99m}Tc-BrTIDA$ can be applied as a hepatobiliary imaging agent for the evaluation of the functional status of the hepatocytes and the patency of the biliary duct.

A study on shield on the center of gravity moving designed for high efficiency operation for the gamma-ray imaging detector (감마선 영상화 장치용 고효율 동작을 위한 차폐체 무게중심 이동 설계에 관한 연구)

  • Park, Gang-teck;Lee, Nam-ho;Hwang, Young-gwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.948-949
    • /
    • 2016
  • In this study, we perform the structure change of the shielding this is applied for gamma-ray detectors for imaging of gamma-ray source. Through previous studies, we implemented the commercially available gamma-ray imaging apparatus similar to the shielding body but weight reduction, center of gravity moving of shield. In this paper, we changed a shield for motion control detectors efficient movement. We performed the MCNP simulation of shield design and then we obtained the results of reducing the weight of the 17% and moving of center of gravity the shield center.

  • PDF

System Design and Evaluation of a Compact and High Energy X-ray Talbot-Lau Grating Interferometer for Industrial Applications

  • Lee, Seho;Oh, Ohsung;Kim, Youngju;Lee, Seung Wook;Kim, Insoo;Kim, Jinkyu
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1827-1833
    • /
    • 2018
  • X-ray grating interferometry has been an active area of research in recent years. In particular, various studies have been carried out for the practical use of the x-ray grating interferometer in medical and industrial fields. For the commercialization of the system, it needs to be optimized for its application. In this study, we have developed a prototype of the compact high energy x-ray grating interferometer of which the high effective energy and compactness is of our primary feature of design. We have designed the Talbot-Lau x-ray interferometer in a symmetrical geometry with an effective energy of 54.3 keV. The system has a source-to-analyzer grating distance of 788.4 mm, which is compact enough for a commercial product. In a normal operation, it took less than ten seconds to acquire a set of phase stepping images. The acquired images had a maximum visibility of about 15%, which is relatively high compared with the visibilities of the other high-energy grating interferometric systems reported so far.

Robust group independent component analysis (로버스트 그룹 독립성분분석)

  • Kim, Hyunsung;Li, XiongZhu;Lim, Yaeji
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.2
    • /
    • pp.127-139
    • /
    • 2021
  • Independent Component Analysis is a popular statistical method to separate independent signals from the mixed data, and Group Independent Component Analysis is an its multi-subject extension of Independent Component Analysis. It has been applied Functional Magnetic Resonance Imaging data and provides promising results. However, classical Group Independent Component Analysis works poorly when outliers exist on data which is frequently occurred in Magnetic Resonance Imaging scanning. In this study, we propose a robust version of the Group Independent Component Analysis based on ROBPCA. Through the numerical studies, we compare proposed method to the conventional method, and verify the robustness of the proposed method.

Investigation of Near Infrared Radiation Based Screening for Video-Fluoroscopy Swallowing Studies (비디오투시연하검사 스크리닝을 위한 근적외선 기술 조사)

  • Park, Ji-Su;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.9-14
    • /
    • 2021
  • With the recent advances in radiological science, there was radiographic techniques development and several researches to diagnosing dysphagia. We proposed the new Imaging technology based on Near Infrared radiation (NIR) for video fluoroscopic swallowing study (VFSS). To reduce the risk of the VFSS examination for swallowing rehabilitation, multi-NIR camera system comprised. Based on the multi-NIR camera imaging system, Computational simulation was conducted to identify the potential of the multi-NIR camera imaging system as a clinical tool (screening system). As a result of the simulation applied in this study, the proposed system has a potential to be a clinical solution although there is a few of limitations. we believe that it will be a good tool to support the VFSS as a screening technology in clinical fields.

FAP Inhibitors as Novel Small Molecules for Cancer Imaging using Radionuclide

  • Anvar Mirzaei;Jung-Joon Min;Dong-Yeon Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.9 no.1
    • /
    • pp.49-55
    • /
    • 2023
  • Tumors are encircled by various non-cancerous cell types in the extracellular matrix, including fibroblasts, endothelial cells, immune cells, and cytokines. Fibroblasts are the most critical cells in the tumor stroma and play an important role in tumor development, which has been highlighted in some epithelial cancers. Many studies have shown a tight connection between cancerous cells and fibroblasts in the last decade. Regulatory factors secreted into the tumor environment by special fibroblast cells, cancer-associated fibroblasts (CAFs), play an important role in tumor and vessel development, metastasis, and therapy resistance. This review addresses the development of FAP inhibitors, emphasizing the first, second, and latest generations. First-generation inhibitors exhibit low selectivity and chemical stability, encouraging researchers to develop new scaffolds based on preclinical and clinical data. Second-generation enzymes such as UAMC-1110 demonstrated enhanced FAP binding and better selectivity. Targeted treatment and diagnostic imaging have become possible by further developing radionuclide-labeled fibroblast activation protein inhibitors (FAPIs). Although all three FAPIs (01, 02, and 04) showed excellent preclinical and clinical findings. The final optimization of these FAPI scaffolds resulted in FAPI-46 with the highest tumor-to-background ratio and better binding affinity.

Transfer Learning based Parameterized 3D Mesh Deformation with 2D Stylized Cartoon Character

  • Sanghyun Byun;Bumsoo Kim;Wonseop Shin;Yonghoon Jung;Sanghyun Seo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.3121-3144
    • /
    • 2023
  • As interest in the metaverse has grown, there has been a demand for avatars that can represent individual users. Consequently, research has been conducted to reduce the time and cost required for the current 3D human modeling process. However, the recent automatic generation of 3D humans has been focused on creating avatars with a realistic human form. Furthermore, the existing methods have limitations in generating avatars with imbalanced or unrealistic body shapes, and their utilization is limited due to the absence of datasets. Therefore, this paper proposes a new framework for automatically transforming and creating stylized 3D avatars. Our research presents a definitional approach and methodology for creating non-realistic character avatars, in contrast to previous studies that focused on creating realistic humans. We define a new shape representation parameter and use a deep learning-based method to extract character body information and perform automatic template mesh transformation, thereby obtaining non-realistic or unbalanced human meshes. We present the resulting outputs visually, conducting user evaluations to demonstrate the effectiveness of our proposed method. Our approach provides an automatic mesh transformation method tailored to the growing demand for avatars of various body types and extends the existing method to the 3D cartoon stylized avatar domain.

Metachronous Contralateral Axillary Lymph Node Metastasis from Invasive Breast Carcinoma: A Case Report with Imaging Findings (침윤성 유방암의 이시성 반대쪽 액와 림프절 전이: 영상 소견을 포함한 증례 보고)

  • Jieun Kim;Hyun Kyung Jung;Woogyeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.239-245
    • /
    • 2022
  • Contralateral axillary lymph node metastasis is a rare entity in breast cancer and is currently classified as a distant metastasis; however, recent studies have proposed aggressive curative treatment since this entity may manifest as a locoregional disease. Herein, we report a rare case of contralateral axillary lymph node metastasis that presented with imaging findings 22 months after the initial breast cancer diagnosis in a 67-year-old female. The patient underwent lymph node dissection of the axilla with adjuvant chemotherapy and radiotherapy. A follow-up examination 6 months after surgery showed no evidence of tumor recurrence or metastasis.