• Title/Summary/Keyword: Imaging studies

Search Result 1,610, Processing Time 0.023 seconds

Prediction of High Grade Vesicoureteral Reflux in Infants Less than 3 Months with Urinary Tract Infection (3개월 미만 요로감염 영아에서 중증 방광 요관 역류의 예측인자)

  • Yi, Dae-Yong;Kim, Na-Yeon;Cho, Hee-Yeon;Kim, Ji-Eun;Sim, So-Yeon;Son, Dong-Woo;Jeon, In-Sang;Cha, Han
    • Childhood Kidney Diseases
    • /
    • v.12 no.2
    • /
    • pp.178-185
    • /
    • 2008
  • Purpose : Our aim was to investigate the predictive factors for detecting grade III-V vesicoureteral reflux(VUR) in young infants less than 3 months with urinary tract infections (UTI). Methods : Data of infants who underwent ultrasonography and VCUG between January 2004 and September 2007 were reviewed. Age, gender, incidence of bacteremia, C-reactive protein(CRP) and imaging studies were compared between group I(grade III-V VUR) and group II (normal or grade I and II VUR) retrospectively. Sensitivity, specificity, positive and negative predictive values, odds ratio, and likelihood ratio of ultrasonography for high grade VUR were evaluated. Results : Among 54 enrolled infants(41 males, 13 females), 14 infants were group I and 40 infants were group II. In the group I, CRP level was significantly higher(6.11$\pm$5.18 vs. 3.27$\pm$3.45, P=0.025), and there were more ultrasonographic abnormal findings(71.4%, vs. 22.5%, P=0.002) compared with group II. However, ultrasonography was the only significant factor after adjusting with logistic regression(P=0.002). Incidence of bacteremia and abnormal DMSA findings were not significantly different in two groups. Sensitivity, specificity, and odds ratio of ultrasonography was 71.4%, 77.5%, 6.9 respectively. Negative predictive value was 88.6% and negative likelihood ratio was 0.37. Ultrasonography had significant negative likelihood ratio for grade III-V VUR, but missed 4 infants with grade III VUR. Conclusion : We could not find any alternative predictive factors to reduce VCUG in detecting high grade VUR. Therefore, VCUG must be considered in young infants less than 3 months with UTI.

Effectiveness of Radionuclide Cisternography to Detect the Leakage Site of CSF in Spontaneous Intracranial Hypotension; Preliminary Report (자발성 두개강내 저뇌압증 환자의 뇌척수액 누출부위 진단에 방사성동위원소 뇌조조영술의 유효성: 예비결과 보고)

  • Kim, Seong-Min;Kim, Jae-Moon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.148-154
    • /
    • 2006
  • Purpose: Although radionuclide cisternography (RNC) is an useful study to detect cerebrospinal fluid (CSF) leakage in the patient with spontaneous intracranial hypotension (SIH), it sometimes fails to demonstrate the site of CSF leakage. The aim of the study is to improve the detection of leakage site of CSF and to reduce time for the study in RNC using modified protocol (m-RNC). Materials & methods : The study consists of 8 studies of 7 patients ($38{\pm}8$ years, M:F=2:5) with SIH, who underwent m-RNC following administration of 185-222 MBq of $^{99m}Tc$-DTPA into the lumbar subarachnoid space. Sequential images were obtained the whole spine with the head including urinary bladder at 10 minute, 30 minute, 1 hour, 2 hour, 4 hour and 6 hour. Radioactivity of extradural space and urinary bladder was evaluated. Results: Leakage site of CSF was identified in all 8 cases by m-RNC. Leakage site was cervicothoracic junction (CTJ, n=3), CTJ with C1-2 (n=2), CTJ with thoracic spine, thoracolumbar spine and lumbar spine (each n=1). All cases presented leakage sites within 1 hour and multiple sites, where CTJ was included in 6 cases. Only one case presented additional site in 6 hour image. Early radioactivity within the urinary bladder was noted in 6 cases, but that was fellowing after identification of the leakage site. Conclusion: Radionuclide cisternography is sensitive to detect the leakage site of CSF and is expected to improve the detection of CSF leakage site and reduce time for the study using modified protocol.

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

Diagnostic Accuracy of Rest T1-201/Stress Tc-99m-MIBI Myocardial SPECT in the Diagnosis of Coronary Artery Disease (휴식 T1-201/부하 Tc-99m MIBI 심근 SPECT의 관상동맥질환 진단 정확성)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Sohn, Dae-Won;Oh, Byung-Hee;Lee, Myung-Mook;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.112-117
    • /
    • 1996
  • Objective: Standard stress/rest Tc-99m MIBI and T1-201 myocardial perfusion study have some limitations such as stress/rest image overlap for Tc-99m-MIBI, low energy for T1-201 and long period of study time for two separate studies. Separate acquisition rest T1-201/stress Tc-99m MIBI dual isotope study is a potentially efficient myocardial perfusion imaging protocol that combines the high resolution of Tc-99m for stress perfusion assessment and T1-201 for viability assessment. This study assessed the usefulness and diagnostic accuracy for this new approach. Methods: We tried to evaluate sensitivity and specificity of dual isotope separate acquisition protocol in 67 patients. Immediately after resting T1-201 SPECT data was acquired, dipyridamole stress Tc-99m MIBI myocardial perfusion study was performed. Visual analysis was carried out qualitatively with 0 to 3 scoring system for 17 segments of left ventricle in the reconstructed horizontal long axis and short axis slices. Results: Total study was completed within 3 hours. In angiographic correlation, dual isotope SPECT demonstrated high sensitivity(85%) and in a small group of patients, high specificity was also observed (100%). Conclusion: Combined thallium-201/stress Tc-99m MIBI SPECT displayed similiar diagnostic accuracy to protocol using stress/rest Tc-99m MIBI SPECT. This protocol was completed in shorter period than the previous protocols and therefore enhance laboratory throughput and patients convenience.

  • PDF

Efficacy Assessment of Endovascular Stenting in Patients with Unilateral Middle Cerebral Artery Stenosis Using Statistical Probabilistic Anatomical Mapping Analysis of Basal/Acetazolamide Brain Perfusion SPECT (기저/아세타졸아미드 국소뇌혈류 SPECT의 확률 뇌지도 분석을 이용한 일측 중대뇌동맥 협착환자에서 시행한 스텐트 삽입술의 효용성 평가)

  • Kim, Hae-Won;Won, Kyoung-Sook;Zeon, Seok-Kil;Lee, Chang-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.280-286
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the hemodynamic changes after endovascular stenting in patients with unilateral middle cerebral artery (MCA) stenosis using statistical probabilistic anatomical mapping (SPAM) analysis of basal/acetazolamide (ACZ) Tc-99m ECD brain perfusion SPECT. Materials and Methods: Eight patients (3 men and 5 women, 64.8$\pm$10.5 years) who underwent endovascular stenting for unilateral MCA stenosis were enrolled. Basal/ACZ Tc-99m ECD brain perfusion SPECT studies were performed by one-day protocol before and after stenting. Using SPAM analysis, we compared basal cerebral perfusion (BCP) counts and cerebrovascular reserve (CVR) index of the MCA territory before stenting with those after stenting. Results: After stenting, no patient had any complication nor additional stroke. In SPAM analysis, 7 out of the 8 patients had improved BCP counts of the MCA territory and 7 out of the 8 patients had improved CVR index of the MCA territory after stenting. Before stenting, the mean BCP counts and CVR index in the affected MCA territory were 47.1$\pm$2.2 ml/min/100 g and -2.1$\pm$2.9%, respectively. After stenting, the mean BCP counts and CVR index in the affected MCA territory were improved significantly (48.3$\pm$2.9 ml/min/100 g, p =0.025 and 0.1$\pm$1.3%, p =0.036). Conclusion: This study revealed that SPAM analysis of basal/ACZ brain perfusion SPEG would be helpful to evaluate hemodynamic efficacy of endovascular stenting in unilateral MCA stenosis.

True Orthoimage Generation from LiDAR Intensity Using Deep Learning (딥러닝에 의한 라이다 반사강도로부터 엄밀정사영상 생성)

  • Shin, Young Ha;Hyung, Sung Woong;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.4
    • /
    • pp.363-373
    • /
    • 2020
  • During last decades numerous studies generating orthoimage have been carried out. Traditional methods require exterior orientation parameters of aerial images and precise 3D object modeling data and DTM (Digital Terrain Model) to detect and recover occlusion areas. Furthermore, it is challenging task to automate the complicated process. In this paper, we proposed a new concept of true orthoimage generation using DL (Deep Learning). DL is rapidly used in wide range of fields. In particular, GAN (Generative Adversarial Network) is one of the DL models for various tasks in imaging processing and computer vision. The generator tries to produce results similar to the real images, while discriminator judges fake and real images until the results are satisfied. Such mutually adversarial mechanism improves quality of the results. Experiments were performed using GAN-based Pix2Pix model by utilizing IR (Infrared) orthoimages, intensity from LiDAR data provided by the German Society for Photogrammetry, Remote Sensing and Geoinformation (DGPF) through the ISPRS (International Society for Photogrammetry and Remote Sensing). Two approaches were implemented: (1) One-step training with intensity data and high resolution orthoimages, (2) Recursive training with intensity data and color-coded low resolution intensity images for progressive enhancement of the results. Two methods provided similar quality based on FID (Fréchet Inception Distance) measures. However, if quality of the input data is close to the target image, better results could be obtained by increasing epoch. This paper is an early experimental study for feasibility of DL-based true orthoimage generation and further improvement would be necessary.

Current Situation on Signing Advance Medical Directives and Actual Life-sustaining Treatment Given at a University Hospital (일개 대학병원의 연명치료 선택 및 사전의료의향서 작성 현황)

  • Yoon, Ho-Min;Choi, Youn-Seon;Hyun, Jong-Jin
    • Journal of Hospice and Palliative Care
    • /
    • v.14 no.2
    • /
    • pp.91-100
    • /
    • 2011
  • Purpose: This study was performed to investigate patients' preferences on receiving life-sustaining treatments (LST) and to analyze the relationship between patients' characteristics and LST selection. We also examined any discrepancy between LST patients' choices regarding medical intervention and actual medical intervention given/not given within 48 hours before death. Methods: This cross-sectional study was performed from March 1, 2008 to August 31, 2008 in the Palliative Care Unit of Korea University Hospital. Electric medical records (EMR) of 102 hospice cancer patients were reviewed, and 74 patients with Glasgow coma scale (GCS) ${\geq}$10 at the time of signing the advance medical directives (AMD) were selected for the first analysis. Then, patients alive at the end of this study, transferred to other hospitals or dead within 48 hours were excluded, and the remaining 42 patients were selected for the second analysis. Results: Preferred LST included antibiotics, total parenteral nutrition, tube feeding, transfusion, and laboratory and imaging studies. The relationship between patients' characteristics and LST could not be analyzed due to skewed preferences. LST chosen at the time of signing the AMD and actual medical intervention given/not given in the last 48 hours showed discrepancy in most cases. Conclusion: When making AMD in hospice cancer patients, it is important to consider the time and possibility of changing the choices. Above all, patients must fully understand the AMD. Thus, LST should always be provided with careful consideration of all possibilities, because legal and social aspects of AMD have not been established yet.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

Application of Borehole Radar to Tunnel Detection (시추공 레이다 탐사에 의한 지하 터널 탐지 적용성 연구)

  • Cho, Seong-Jun;Kim, Jung-Ho;Kim, Chang-Ryol;Son, Jeong-Sul;Sung, Nak-Hun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.279-290
    • /
    • 2006
  • The borehole radar methods used to tunnel detection are mainly classified into borehole radar reflection, directional antenna, crosshole scanning, and radar tomography methods. In this study, we have investigated the feasibility and limitation of each method to tunnel detection through case studies. In the borehole radar reflection data, there were much more clear diffraction signals of the upper wings than lower wings of the hyperbolas reflected from the tunnel, and their upper and lower wings were spreaded out to more than 10m higher and lower traces from the peaks of the hyperbolas. As the ratio of borehole diameter to antenna length increases, the ringing gets stronger on the data due to the increase in the impedance mismatching between antennas and water in the boreholes. It is also found that the reflection signals from the tunnel could be enhanced using the optimal offset distance between transmitter and receiver antennas. Nevertheless, the borehole radar reflection data could not provide directional information of the reflectors in the subsurface. Direction finding antenna system had a advantage to take a three dimensional location of a tunnel with only one borehole survey even though the cost is still very high and it required very high expertise. The data from crosshole scanning could be a good indicator for tunnel detection and it could give more reliable result when the borehole radar reflection survey is carried out together. The images of the subsurface also can be reconstructed using travel time tomography which could provide the physical property of the medium and would be effective for imaging the underground structure such as tunnels. Based on the results described above, we suggest a cost-effective field procedure for detection of a tunnel using borehole radar techniques; borehole radar reflection survey using dipole antenna can firstly be applied to pick up anomalous regions within the borehole, and crosshole scanning or reflection survey using directional antenna can then be applied only to the anomalous regions to detect the tunnel.

Simultaneous Elevation of Serum Parathyroid Hormone(PTH) and Parathyroid Hormone-related Protein(PTHrP) in a Case of Lung Cancer with Hypercalcemia (고칼슘혈증을 보인 폐암환자에서 부갑상선호르몬(PTH)과 부갑상선호르몬관련단백질(PTHrP)이 동시에 증가된 1예)

  • Kim, Yu-Il;Kim, Kyu-Sik;Yu, Young-Kwon;Park, Chang-Min;Rim, Myung-Soo;Ko, Kyung-Haeng;Hwang, Jun-Hwa;Park, Hyeong-Kwan;Lim, Sung-Chul;Kim, Young-Chul;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.4
    • /
    • pp.525-532
    • /
    • 1999
  • The parathyroid hormone related protein (PTHrP) is the most common causative peptide of humoral hypercalcemia of malignancy. In contrast, the serum level of parathyroid hormone (PTH) is low to undetectable in the majority of patients with malignancy associated hypercalcemia. Few cases exist in which the production and secretion of PTH by malignant nonparathyroid tumors have been authenticated. To our knowledge, there is very rare case in which a nonparathyroid tumor expressed simultaneously both the PTH and PTHrP. We report a case of squamous cell carcinoma of the lung with hypercalcemia which presented with simultaneous elevation of serum PTH and PTHrP. Severe hypercalcemia (serum calcium, 7.5 mEq/L) was found in a 65-year-old man who had a squamous cell carcinoma of the lung without any bony metastasis and detectable parathyroid abnormalities on isotope scintigraphy. The serum level of intact parathyroid hormone (PTH) con centration was markedly elevated as measured in two site radioimmunoreactive PTH assays (intact PTH 150 pg/mL ; normal 9~55). The serum level of a PTHrP was also increased as measured in C-terminal region specific radioimmunoassay (PTHrP 99.1 pmol/L; normal 13.8~55.3). There are no evidences of coincidental primary hyperparathyroidism in parathyroid MIBI scan and other imaging studies including neck ultrasonography and computed tomography. These results suggest that simultaneous elevation of serum PTH and PTHrP in this patient can be caused by production of both PTHrP and PTH in other nonparathyroid lesions such as squamous cell carcinoma.

  • PDF