• Title/Summary/Keyword: Imaging quality

Search Result 1,337, Processing Time 0.032 seconds

EVALUATION OF THE RADIOMETRIC AND SPECTRAL CHARACTERISTICS OF THE CAISS

  • Lee, Kwang-Jae;Yong, Sang-Soon;Kim, Yong-Seung
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.243-246
    • /
    • 2008
  • The Compact Airborne Imaging Spectrometer System (CAISS) was jointly designed and developed as the hyperspectral imaging system by Korea Aerospace Research Institute (KARI) and ELOP inc., Israel. The primary mission of the CAISS is to acquire and provide full contiguous spectral information with high quality spectral and high spatial resolution for advanced applications in the field of remote sensing. The CAISS consists of six physical units; the camera system, the gyro-stabilized mount, the jig, the GPS/INS, the power inverter and distributor, and the operating system. These subsystems shall be tested and verified in the laboratory before the flight. Especially the camera system of the CAISS shall be calibrated and validated with the calibration equipments such as the integrated sphere and spectral lamps. To improve data quality and availability, it is the most important to understand the mechanism of hyperspectral imaging system and the radiometric and spectral characteristics. This paper presents the major characteristics of camera system on the CAISS and summarizes the results of radiometric and spectral experiment during preliminary system verification.

  • PDF

The Evaluation of Image Quality using Time of Flight in Intracranial Magnetic Resonance Imaging : Comparison with 1.5 T and 3.0 T (뇌혈관 자기공명영상에서 Time-of-flight(TOF) 기법을 이용한 영상의 질 평가: 1.5 T 와 3.0 T 자기공명영상 비교)

  • Goo, Eunhoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 2015
  • Intracrnial 3D TOF MR angiography was performed in 30 normal volunteers with both 1.5 and 3.0 T MRI system with high resolutions. Used Voxel sizes were $0.39{\times}0.39{\times}0.2$(1.5 T) and $0.19{\times}0.19{\times}0.35$(3.0 T), respectively. High image quality and depiction of small vessel branches were equality demonstrated with 1.5 T and 3.0 T HR TOF MRA(p<0.05). Intracranial high resolution TOF MRA with 1.5 T and 3.0 T provides high diagnostic information with having merits and demerits in depiction of vascular branches.

  • PDF

Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI

  • Chen Cui;Gang Yin;Minjie Lu;Xiuyu Chen;Sainan Cheng;Lu Li;Weipeng Yan;Yanyan Song;Sanjay Prasad;Yan Zhang;Shihua Zhao
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.114-125
    • /
    • 2019
  • Objective: Segmented cardiac cine magnetic resonance imaging (MRI) is the gold standard for cardiac ventricular volumetric assessment. In patients with difficulty in breath-holding or arrhythmia, this technique may generate images with inadequate quality for diagnosis. Real-time cardiac cine MRI has been developed to address this limitation. We aimed to assess the performance of retrospective electrocardiography-gated real-time cine MRI at 3T for left ventricular (LV) volume and mass measurement. Materials and Methods: Fifty-one patients were consecutively enrolled. A series of short-axis cine images covering the entire left ventricle using both segmented and real-time balanced steady-state free precession cardiac cine MRI were obtained. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and LV mass were measured. The agreement and correlation of the parameters were assessed. Additionally, image quality was evaluated using European CMR Registry (Euro-CMR) score and structure visibility rating. Results: In patients without difficulty in breath-holding or arrhythmia, no significant difference was found in Euro-CMR score between the two techniques (0.3 ± 0.7 vs. 0.3 ± 0.5, p > 0.05). Good agreements and correlations were found between the techniques for measuring EDV, ESV, EF, SV, and LV mass. In patients with difficulty in breath-holding or arrhythmia, segmented cine MRI had a significant higher Euro-CMR score (2.3 ± 1.2 vs. 0.4 ± 0.5, p < 0.001). Conclusion: Real-time cine MRI at 3T allowed the assessment of LV volume with high accuracy and showed a significantly better image quality compared to that of segmented cine MRI in patients with difficulty in breath-holding and arrhythmia.

Image Quality of Amorphous Selenium DR system using MTF measurement (MTF 측정을 통한 비정질 셀레늄 기반의 디지털 방사선 검출기의 영상 질 평가에 관한 연구)

  • Seok, Dae-Woo;Park, Ji-Koon;Choi, Jang-Yong;Nam, Sang-Hee;Kang, Shin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.384-387
    • /
    • 2003
  • In this paper, the evaluation of image quality was performed for digital radiography which is developing in using amorphous selenium as a photoconductor material for the purpose of offering basic research data and measurement technique about Medical Imaging Quality. So Modulation Transfer Function as a main factor of imaging quality evaluation was investigated by slit method. For measurement of MTF, Nuclear associates. 07-624 Slit camera image was obtained to study the variation of MTF corresponding to changing spatial frequency. And Presampling MTF was estimated by slit camera image with $10\;{\mu}m$ width at Digital Radiography. In this study, the obtained data demonstrates that the clinical value of a direct conversion type digital radiation detector using the amorphous selenium, which is being developed by domestic technology.

  • PDF

Breast Magnetic Resonance Image (MRI) Guideline: Breast Imaging Study Group of Korean Society of Magnetic Resonance in Medicine Recommendations

  • Choi, Seon Hyeong;Kang, Bong Joo;Jung, Seung Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.205-208
    • /
    • 2018
  • The purpose of this study is to establish an appropriate protocol for breast magnetic resonance imaging (MRI) in the discipline of image quality standards. The intention of the protocol is to increase effectiveness of medical image information exchange involved in construction, activation, and exchange of clinical information for healthcare.

Visual quality enhancement of three-dimensional photon-counting integral imaging using background noise removal algorithm (배경 잡음 제거 알고리즘을 적용한 3차원 광자 계수 집적 영상의 화질 향상)

  • Cho, Ki-Ok;Kim, Young jun;Kim, Cheolsu;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1376-1382
    • /
    • 2016
  • In this paper, we present a visual quality enhancement technique for conventional three-dimensional (3D) photon counting integral imaging using background noise removal algorithm. Photon counting imaging can detect a few photons from desired objects and visualize them under severely photon-starved conditions such as low light level environment. However, when a lot of photons are generated from background, it is difficult to detect photons from desired objects. Thus, the visual quality of the reconstructed image may be degraded. Therefore, in this paper, we propose a new photon counting imaging method that removes unnecessary background noise and detects photons from only desired objects. In addition, integral imaging can be used to obtain 3D information and visualize the 3D image by statistical estimations such as maximum likelihood estimation. To prove and evaluate our proposed method, we implement the optical experiment and calculate mean square error.

A Study on the Status and Improvement Direction of Radiographic Imaging Examination Assessment in Korea Medical Institutions (한국 의료기관의 방사선 영상검사 평가 현황 및 과제)

  • Young-Kwon Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.565-572
    • /
    • 2023
  • This study was conducted to analyze the status radiological imaging examinations assessment in Korea medical institutions conducted in the public sector and suggest a direction for improvement. Among the assessment of medical institutions, the main assessment related to radiographic imaging examinations are the certification evaluation of medical institutions and the adequacy assessment of radiographic imaging examinations. The certification evaluation of medical institutions evaluates the image inspection operation process, provision of accurate results, and compliance with safety management procedures. In the assessment of adequacy of radiographic imaging examinations, structural indicators related to manpower and equipment, patient evaluation implementation rate, and exposure reduction programs were included. However, for safer and higher-quality radiological imaging examinations, it is necessary to increase the participation rate of medical institutions in certification evaluations. In addition, it is necessary to improve the manpower indicator, and incentive payments can be considered to induce quality improvement of medical institutions in the future. Integrated management of radiation exposure at the national level should also be carried out simultaneously.

Quality Reporting of Radiomics Analysis in Mild Cognitive Impairment and Alzheimer's Disease: A Roadmap for Moving Forward

  • So Yeon Won;Yae Won Park;Mina Park;Sung Soo Ahn;Jinna Kim;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1345-1354
    • /
    • 2020
  • Objective: To evaluate radiomics analysis in studies on mild cognitive impairment (MCI) and Alzheimer's disease (AD) using a radiomics quality score (RQS) system to establish a roadmap for further improvement in clinical use. Materials and Methods: PubMed MEDLINE and EMBASE were searched using the terms 'cognitive impairment' or 'Alzheimer' or 'dementia' and 'radiomic' or 'texture' or 'radiogenomic' for articles published until March 2020. From 258 articles, 26 relevant original research articles were selected. Two neuroradiologists assessed the quality of the methodology according to the RQS. Adherence rates for the following six key domains were evaluated: image protocol and reproducibility, feature reduction and validation, biologic/clinical utility, performance index, high level of evidence, and open science. Results: The hippocampus was the most frequently analyzed (46.2%) anatomical structure. Of the 26 studies, 16 (61.5%) used an open source database (14 from Alzheimer's Disease Neuroimaging Initiative and 2 from Open Access Series of Imaging Studies). The mean RQS was 3.6 out of 36 (9.9%), and the basic adherence rate was 27.6%. Only one study (3.8%) performed external validation. The adherence rate was relatively high for reporting the imaging protocol (96.2%), multiple segmentation (76.9%), discrimination statistics (69.2%), and open science and data (65.4%) but low for conducting test-retest analysis (7.7%) and biologic correlation (3.8%). None of the studies stated potential clinical utility, conducted a phantom study, performed cut-off analysis or calibration statistics, was a prospective study, or conducted cost-effectiveness analysis, resulting in a low level of evidence. Conclusion: The quality of radiomics reporting in MCI and AD studies is suboptimal. Validation is necessary using external dataset, and improvements need to be made to feature reproducibility, feature selection, clinical utility, model performance index, and pursuits of a higher level of evidence.

Imaging Technologies for Nondestructive Measurement of Internal Properties of Agricultural Products: A Review

  • Ahmed, Mohammed Raju;Yasmin, Jannat;Lee, Wang-Hee;Mo, Changyeun;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.42 no.3
    • /
    • pp.199-216
    • /
    • 2017
  • Purpose: This study reviewed the major nondestructive measurement techniques used to assess internal properties of agricultural materials that significantly influence the quality, safety, and value of the products in markets. Methods: Imaging technologies are powerful nondestructive analytical tools that possess specific advantages in revealing the internal properties of products. Results: This review was exploring the application of various imaging techniques, specifically, hyperspectral imaging (HSI), magnetic resonance imaging (MRI), soft X-ray, X-ray computed tomography (XRI-CT), thermal imaging (TI), and ultrasound imaging (UI), to investigate the internal properties of agricultural commodities. Conclusions: The basic instruments used in these techniques are discussed in the initial part of the review. In the context of an investigation of the internal properties of agricultural products, including crops, fruits, vegetables, poultry, meat, fish, and seeds, various extant studies are examined to understand the potential of these imaging technologies. Future trends for these imaging techniques are also presented.

Clinical comparison of intraoral CMOS and PSP detectors in terms of time efficiency, patient comfort, and subjective image quality

  • Kamburoglu, Kivanc;Samunahmetoglu, Ercin;Eratam, Nejlan;Sonmez, Gul;Karahan, Sevilay
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.93-101
    • /
    • 2022
  • Purpose: This study compared the effectiveness of complementary metal-oxide semiconductors (CMOS) and photostimulable phosphor (PSP) plates as intraoral imaging systems in terms of time efficacy, patient comfort, and subjective image quality assessment in real clinical settings. Materials and Methods: Fifty-eight patients (25 women and 33 men) were included. Patients were referred for a full-mouth radiological examination including 1 bitewing radiograph (left and right) and 8 periapical radiographs for each side (left maxilla/mandible and right maxilla/mandible). For each patient, 1 side of the dental arch was radiographed using a CMOS detector, whereas the other side was radiographed using a PSP detector, ensuring an equal number of left and right arches imaged by each detector. Clinical application time, comfort/pain, and subjective image quality were assessed for each detector. Continuous variables were summarized as mean±standard deviation. Differences between detectors were evaluated using repeated-measures analysis of variance. P<0.05 was accepted as significant. Results: The mean total time required for all imaging procedures with the CMOS detector was significantly lower than the mean total time required for imaging procedures with PSP (P<0.05). The overall mean patient comfort scores for the CMOS and PSP detectors were 4.57 and 4.48, respectively, without a statistically significant difference (P>0.05). The performance of both observers in subjectively assessing structures was significantly higher when using CMOS images than when using PSP images for all regions (P<0.05). Conclusion: The CMOS detector was found to be superior to the PSP detector in terms of clinical time efficacy and subjective image quality.