• 제목/요약/키워드: Imaging phantoms

검색결과 114건 처리시간 0.028초

Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

  • Abdala-Junior, Reinaldo;No-Cortes, Juliana;Arita, Emiko Saito;Ackerman, Jerome L.;da Silva, Renan Lucio Berbel;Kim, Jun Ho;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.413-419
    • /
    • 2021
  • Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

Characterization of Rhizophora SPP. particleboards with SOY protein isolate modified with NaOH/IA-PAE adhesive for use as phantom material at photon energies of 16.59-25.26 keV

  • Samson, Damilola Oluwafemi;Shukri, Ahmad;Mat Jafri, Mohd Zubir;Hashim, Rokiah;Sulaiman, Othman;Aziz, Mohd Zahri Abdul;Yusof, Mohd Fahmi Mohd
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.216-233
    • /
    • 2021
  • In this work, Rhizophora spp. particleboard phantoms were made using SPI-based adhesives, modified with sodium hydroxide and itaconic acid polyamidoamine-epichlorohydrin (0, 5, 10, and 15 wt%). An X-ray computed tomography (CT) imaging system was used to ascertain the CT numbers and density distribution profiles of the particleboards. The SPI-based/NaOH/IA-PAE/Rhizophora spp. particleboard phantoms with 15 wt% IA-PAE addition level had the highest solid content, flexural strength, flexural modulus, and internal bonding strength of 36.06 ± 1.08%, 18.61 ± 0.38 Nmm-2, 7605.76 ± 0.89 Nmm-2, and 0.463 ± 0.053 Nmm-2, respectively. The moisture content, mass density, water absorption, and dimensional stability were 6.93 ± 0.27%, 0.962 ± 0.037 gcm-3, 22.36 ± 2.47%, and 10.90 ± 0.86%, respectively. The results revealed that the mass attenuation coefficients and effective atomic number values within the 16.59-25.26 keV photon energy region, were close to the calculated XCOM values in water, with a p-value of 0.077. Moreover, the CT images showed that the dissimilarities in the discrepancy of the profile density decreased as the IA-PAE concentrations increased. Therefore, these results support the appropriateness of the SPI-based/NaOH/IA-PAE/Rhizophora spp. particleboard with 15 wt% IA-PAE adhesive as a suitable tissue-equivalent phantom material for medical health applications.

뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가 (Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD)

  • 신병근;안성민
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.809-817
    • /
    • 2023
  • 뇌출혈 진단 방법 중 CT는 비침습적으로 피사체의 3차원 영상을 제공할 수 있다. 그래서 응급실에서 급성인 환자 상대로 많이 사용되고 중요한 역할을 담당하고 있다. 뇌혈관 CT는 다른 혈관 CT에 비해 비교적 촬영 빈도가 높으며 뇌혈관 CT 검사 시 적절한 SNR, 합리적인 유효선량으로 검사를 해야한다. 뇌혈관 CT 검사 시 이중에너지와 단일에너지를 이용하였을 때 실질적으로 어느 것이 유효선량이 적으며, SNR이 차이가 없는지 환자영상과 Phantom영상을 같이 비교하였다. SNR과 CNR의 P값이 0.05이상일 때 통계적으로 차이가 없다고 보았고, 유효선량은 0.05미만일 경우 통계적으로 차이가 있다고 보았다. 실험에서는 병원영상의 환자선량을 비교하였을 때 이중에너지의 유효선량이 53.53% 적게, Phantom의 OLSD 이중에너지 유효선량이 57.94% 적게, Phantom의 Dose Report의 이중에너지 유효선량이 56.04% 적었다. 그래서 뇌혈관조영 CT는 이중에너지를 권장한다.

위상필터를 사용한 초음파 영사에서의 반점 제거 (Suppression of Speckle in ultrasonic image by Phase Filtering)

  • 김대훈; ;오명환
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1990년도 추계학술대회
    • /
    • pp.5-10
    • /
    • 1990
  • The object detection capabilities of ultrasonic imaging systems are limited by the ability of the detection process to distinguish the resolved object signals from backscattered speckle noise. It has been shown that the phase component of the Fourier transform of the speckle noise is random. Based on this property. we propose a new algorithm for distinguishing between speckle and specular targets. The proposed algorithm is implemented by taking the Fourier transform of the received signal, low-pass filtering the phase, and taking the inverse Fourier transform of the filtered phase to enhance specular reflectors and reduce speckle in the image. Simulations and experiments using phantoms confirm the algorithm yielding significant reduction of speckle noise.

  • PDF

초전도 MRI 마그네트 국산화 개발 (The Domestic Development of a Superconducting MRI Magnet)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

THIN-FILM-COATED DETECTORS FOR NEUTRON DETECTION

  • McGregor Douglas S.;Gersch Holly K.;Sanders Jeffrey D.;Klann Raymond T.;Lindsay John T.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.167-175
    • /
    • 2001
  • Semiconductor diode detectors coated with neutron reactive material are presently under investigation for various uses, such as remote sensing of thermal neutrons, fast neutron counting, and thermal neutron radiography. Theory indicates that single-coated devices can yield thermal neutron efficiencies from 4% to 11 %, which is supported by experimental evidence. Radiation endurance measurements indicate that the devices function well up to a limiting thermal neutron fluence of $10^{13}/cm^2$, beyond which noticeable degradation occurs. Thermal neutron contrast images of step wedges and simple phantoms, taken with dual in-line pixel devices, show promise for thermal neutron imaging detectors.

  • PDF

256-Channel Trans-Admittance Scanner with Lesion Estimation Algorithm for Breast Cancer Detection

  • Oh, Tong-In;Kim, Kyu-Sik;Lee, Jae-Sang;Woo, Eung-Je;Park, Chun-Jae
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권4호
    • /
    • pp.207-214
    • /
    • 2005
  • Breast cancer detection using electrical impedance techniques is based on numerous experimental findings that cancerous tissues have higher electrical conductivity values than normal tissues. Lately, by taking advantage of the structure of current flows underneath a planar probe of array electrodes, a mathematical formula to find lesions from a measured trans­admittance map has been derived. In order to experimentally validate its mathematical analysis and the suggested lesion estimation algorithm, we developed a 256-channel trans-admittance scanner (TAS) for probing anomalies underneath a planar array of electrodes. In this paper, we describe the design and implementation of the TAS. Its performance together with the lesion estimation algorithm was evaluated using saline phantoms. Further studies are proposed to validate the system on human subjects.

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제44권5호
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

다중 추적자 영상을 위한 컴프턴 카메라 (Multi-tracer Imaging of a Compton Camera)

  • 김수미
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.18-27
    • /
    • 2015
  • 컴프턴 산란 현상을 이용하여 전자적 집속 방법으로 영상화하는 컴프턴카메라는 고민감도 및 고에너지 해상도의 장점을 이용하여 핵의학 응용분야에 대한 잠재력이 큰 영상 시스템이다. 본 논문에서는 컴프턴카메라를 이용한 다중 추적자 영상의 효용성 평가와 정확한 3차원 단면영상 촬영을 위한 Orlov 조건을 만족하는 회전하는 컴프턴카메라의 구조를 조사하였다. 140/511 keV의 방사선원의 소프트웨어 모형을 구성하고 이에 대한 몬테카를로 전산모사 시뮬레이션을 수행하여 리스트모드 배열된 부분집합 기댓값 최대화 방법으로 재구성된 다중 추적자 영상으로 컴프턴카메라의 효용성을 검증하였다. 산란부와 흡수부를 평행하게 위치시킨 고정된 컴프턴카메라와 촬영대상 주위 $360^{\circ}$를 회전하는 컴프턴카메라를 구성하여 검출된 투사선의 구좌표계 각도에 대한 히스토그램을 비교 평가하였다. 140/511 keV의 동시 계측된 몬테카를로 전산모사 데이터의 다중 추적자 영상이 2차원 및 3차원 재구성 시 잘 구분되는 것을 확인하였으며, 회전된 컴프턴카메라의 경우, 회전각도에 반비례하여 3차원 영상재구성에 필요한 유효 투사선이 증가하였다. 26분의 계산 시간 및 5백만개의 적절한 유효 투사선의 개수를 고려할 때 컴프턴카메라의 회전각은 $30^{\circ}$가 현실적으로 적절할 것이며 증가한 검출 시간은 다중 컴프턴카메라를 구성하여 해결할 수 있다. 본 논문에서 고찰한 고민감도 및 고에너지 해상도를 가진 컴프턴 카메라는 다중추적자 영상화를 위해 적합한 시스템이며 생화학 및 생리학적 상태 변화에 대한 임상 정보를 제공하며 각종 질병 진단 및 치료 방법 개발 등에 기여할 수 있는 잠재력이 있는 영상 시스템이다.

초음파 탄성 영상 평가를 위한 플라스틱 기반의 팬텀 개발 (Ultrasonic Phantom Based on Plastic Material for Elastography)

  • 안동기;정목근
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.368-373
    • /
    • 2009
  • 초음파 의료용 탄성 영상 시스템의 성능을 평가하기 위한 인체 조직 모사 팬텀을 제작하였다. 인체에서 종양이나 암 조직은 주위의 정상조직보다 단단한 특성을 가진다. 이러한 조직의 단단함을 영상화하는 기법이 탄성 영상 기법이다. 인체의 병변 조직의 기계적인 특성을 모사하기 위하여 플라스틱 경화제와 연화제를 이용하여 탄성도가 다른 균일 탄성 팬텀을 제작하였다. 제작된 균일 탄성 팬텀은 시료의 비율에 따라 $11.1{\sim}79.6$ kPa 범위의 탄성계수 값을 얻었다. 이를 바탕으로 외부 매질과 내부 매질의 탄성계수 차이가 5배와 7배 정도인 초음파 병변 모사 팬텀을 제작하여 탄성 영상을 획득하였다. 본 논문에서는 제작된 플라스틱 기반의 탄성 팬텀이 인체의 탄성 특성을 모사하는 탄성 팬텀으로서 유용함을 확인하였다.