• Title/Summary/Keyword: Imaging optical system

Search Result 585, Processing Time 0.028 seconds

The improved facial expression recognition algorithm for detecting abnormal symptoms in infants and young children (영유아 이상징후 감지를 위한 표정 인식 알고리즘 개선)

  • Kim, Yun-Su;Lee, Su-In;Seok, Jong-Won
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.430-436
    • /
    • 2021
  • The non-contact body temperature measurement system is one of the key factors, which is manage febrile diseases in mass facilities using optical and thermal imaging cameras. Conventional systems can only be used for simple body temperature measurement in the face area, because it is used only a deep learning-based face detection algorithm. So, there is a limit to detecting abnormal symptoms of the infants and young children, who have difficulty expressing their opinions. This paper proposes an improved facial expression recognition algorithm for detecting abnormal symptoms in infants and young children. The proposed method uses an object detection model to detect infants and young children in an image, then It acquires the coordinates of the eyes, nose, and mouth, which are key elements of facial expression recognition. Finally, facial expression recognition is performed by applying a selective sharpening filter based on the obtained coordinates. According to the experimental results, the proposed algorithm improved by 2.52%, 1.12%, and 2.29%, respectively, for the three expressions of neutral, happy, and sad in the UTK dataset.

Development of Dental Calculus Diagnosis System using Fluorescence Detection (형광 검출을 이용한 치석 진단 시스템 개발)

  • Jang, Seon-Hui;Lee, Young-Rim;Lee, Woo-Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.715-722
    • /
    • 2022
  • If you don't regularly go to the dentist to check your teeth, it is difficult to notice cavities or various diseases of your teeth until you have pain or discomfort. Dental plaque is produced by the combination of food or foreign substances and bacteria in the mouth. Starch breaks down from the bacteria that form tartar. The acid that occurs at this time melts the enamel of the teeth and becomes a cavity. So tartar management is important. Poppyrin, the metabolism of bacteria in the mouth, reacts at 405 nm wavelengths and becomes red fluorescent, which can be seen by imaging through certain wavelength filters. By the above method, Frag and tartar are fluorescently detected and photographed with a yellow series of filters that pass wavelengths of 500 nm or more. It uses MATLAB to detect and display red fluorescence through image processing. Using the difference in voltage between normal teeth and tartar through an optical measuring circuit, it was connected to an Arduino and displayed on the LCD. This allows the user to know the presence and location of dental plaque more accurately.

Identification of Multiple Cancer Cell Lines from Microscopic Images via Deep Learning (심층 학습을 통한 암세포 광학영상 식별기법)

  • Park, Jinhyung;Choe, Se-woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.374-376
    • /
    • 2021
  • For the diagnosis of cancer-related diseases in clinical practice, pathological examination using biopsy is essential after basic diagnosis using imaging equipment. In order to proceed with such a biopsy, the assistance of an oncologist, clinical pathologist, etc. with specialized knowledge and the minimum required time are essential for confirmation. In recent years, research related to the establishment of a system capable of automatic classification of cancer cells using artificial intelligence is being actively conducted. However, previous studies show limitations in the type and accuracy of cells based on a limited algorithm. In this study, we propose a method to identify a total of 4 cancer cells through a convolutional neural network, a kind of deep learning. The optical images obtained through cell culture were learned through EfficientNet after performing pre-processing such as identification of the location of cells and image segmentation using OpenCV. The model used various hyper parameters based on EfficientNet, and trained InceptionV3 to compare and analyze the performance. As a result, cells were classified with a high accuracy of 96.8%, and this analysis method is expected to be helpful in confirming cancer.

  • PDF

A Review of Hyperspectral Imaging Analysis Techniques for Onset Crop Disease Detection, Identification and Classification

  • Awosan Elizabeth Adetutu;Yakubu Fred Bayo;Adekunle Abiodun Emmanuel;Agbo-Adediran Adewale Opeyemi
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Recently, intensive research has been conducted to develop innovative methods for diagnosing plant diseases based on hyperspectral technologies. Hyperspectral analysis is a new subject that combines optical spectroscopy and image analysis methods, which makes it possible to simultaneously evaluate both physiological and morphological parameters. Among the physiological and morphological parameters are classifying healthy and diseased plants, assessing the severity of the disease, differentiating the types of pathogens, and identifying the symptoms of biotic stresses at early stages, including during the incubation period, when the symptoms are not visible to the human eye. Plant diseases cause significant economic losses in agriculture around the world as the symptoms of diseases usually appear when the plants are infected severely. Early detection, quantification, and identification of plant diseases are crucial for the targeted application of plant protection measures in crop production. Hence, this can be done by possible applications of hyperspectral sensors and platforms on different scales for disease diagnosis. Further, the main areas of application of hyperspectral sensors in the diagnosis of plant diseases are considered, such as detection, differentiation, and identification of diseases, estimation of disease severity, and phenotyping of disease resistance of genotypes. This review provides a deeper understanding, of basic principles and implementation of hyperspectral sensors that can measure pathogen-induced changes in plant physiology. Hence, it brings together critically assessed reports and evaluations of researchers who have adopted the use of this application. This review concluded with an overview that hyperspectral sensors, as a non-invasive system of measurement can be adopted in early detection, identification, and possible solutions to farmers as it would empower prior intervention to help moderate against decrease in yield and/or total crop loss.

Laser Tracking Analysis of Space Debris using SOLT System at Mt. Gamak (감악산 SOLT 시스템을 이용한 우주잔해물 레이저추적 성능분석)

  • Lim, Hyung-Chul;Park, Jong-Uk;Kim, Dong-Jin;Seong, Kipyung;Ka, Neung-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.830-837
    • /
    • 2015
  • Space debris has been a major issue recently for the space-active nations because its growing population is expected to increase the collision risk with operational satellites. Radar and electro-optical system has been used for space debris surveillance, which may cause unnecessary anti-collision manoeuvers due to their low tracking accuracy. So an additional tracking system is required to improve the predicted orbit accuracy and then to jude the anti-collision maneouvers more efficiently. The laser tracking system has been considered as an alternative to decrease these unnecessary manoeuvers. Korea Astronomy and Space Science Institute has been developing a space object laser tracking system which is capable of laser tracking for satellites with retro-reflectors and for space debris using high power laser, and satellite imaging using adaptive optics. In this study, the tracking capability is analyzed for space debris using high power laser based on link budget, false alarm probability and signal detection probability.

Estimating Fine Particulate Matter Concentration using GLDAS Hydrometeorological Data (GLDAS 수문기상인자를 이용한 초미세먼지 농도 추정)

  • Lee, Seulchan;Jeong, Jaehwan;Park, Jongmin;Jeon, Hyunho;Choi, Minha
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.919-932
    • /
    • 2019
  • Fine particulate matter (PM2.5) is not only affected by anthropogenic emissions, but also intensifies, migrates, decreases by hydrometeorological factors. Therefore, it is essential to understand relationships between the hydrometeorological factors and PM2.5 concentration. In Korea, PM2.5 concentration is measured at the ground observatories and estimated data are given to locations where observatories are not present. In this way, the data is not suitable to represent an area, hence it is impossible to know accurate concentration at such locations. In addition, it is hard to trace migration, intensification, reduction of PM2.5. In this study, we analyzed the relationships between hydrometeorological factors, acquired from Global Land Data Assimilation System (GLDAS), and PM2.5 by means of Bayesian Model Averaging (BMA). By BMA, we also selected factors that have meaningful relationship with the variation of PM2.5 concentration. 4 PM2.5 concentration models for different seasons were developed using those selected factors, with Aerosol Optical Depth (AOD) from MODerate resolution Imaging Spectroradiometer (MODIS). Finally, we mapped the result of the model, to show spatial distribution of PM2.5. The model correlated well with the observed PM2.5 concentration (R ~0.7; IOA ~0.78; RMSE ~7.66 ㎍/㎥). When the models were compared with the observed PM2.5 concentrations at different locations, the correlation coefficients differed (R: 0.32-0.82), although there were similarities in data distribution. The developed concentration map using the models showed its capability in representing temporal, spatial variation of PM2.5 concentration. The result of this study is expected to be able to facilitate researches that aim to analyze sources and movements of PM2.5, if the study area is extended to East Asia.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

2-DG Autoradiographic Imaging of Brain Activity Patterns by Electroacupuncture Stimulation in Awake Rats (전침자극(電針刺戟)에 의한 흰쥐 중추신경계(中樞神經系)내 대사활성(代謝活性) 변화(變化)의 영상화(映像化) 연구(硏究))

  • Sohn, Young-Joo;Won, Ran;Jung, Hyuk-Sang;Kim, Yong-Suk;Park, Young-Bae;Sohn, Nak-Won
    • Journal of Acupuncture Research
    • /
    • v.18 no.3
    • /
    • pp.56-68
    • /
    • 2001
  • Objective : Functional brain mapping study on acupuncture stimulation using the [14C]2-deoxyglucose([14C]2-DG) autoradiography provides quantitative data and visualized pathway in central nervous system(CNS). We aimed to investigate the neural pathway and spatial distribution of metabolic activity elicited in CNS on electroacupuncture stimulation using [14C]2-DG autoradiography. Methods : The study were divided into three groups by stimulation times. 45-mins stimulation group according to Sokoloffs method, 5-mins stimulation group according to Duncun's method, and 15-mins stimulation group. ;A venous catheter was equipped into right jugular vein. The rats (Sprague-Dawley rats, 230-260g) were kept fastened loosely on a holding platform without anesthesia. Electroacupuncture stimulation (5 ms, 2 Hz, 1~3 mA) were applied on the left Zusanli (ST36) acupoint and [14C]2-DG ($25{\mu}Ci/rat$) injection was performed through the catheter. After sacrifice, the brain and the spinal cord were made to sections for film image. The film images were digitalized as the isotope concentration based upon comparison of optical densities with that of the standards and normalized by the optical density of corpus callosum. Results : 1. 15-mins stimulation group was most effective among 3 experiments. 2. On 15-mins stimulation group, medial geniculate nucleus, intetpeduncular nucleus intermedius, ventral periolivary nucleus, caudal periolivary nucleus, medial superior olive, lateral paragigantocellular nucleus, including hypothalamic arcuate nucleus were increased by more than 25% (at least, p<0.05) by electroacupuncture stimulation. 3. Especially, the metabolism in hypothalamic arcuate nucleus was increased by 90% (p<0.05). 4. The fact that arcuate nucleus of hypothalamus might play a role of interconnection area between ascending and descending pathway of acupuncture stimulation was demonstrated visually. Conclusions : Advanced study on electroacupuncture stimulation elicited significant increase of metabolic activity in various nuclei of hypothalamus will provide the important experimental basis in research of the relationship between electroacupuncture stimulation and internal visceral functions.

  • PDF

A Study on the Anti-Reflection Coating Effects of Polymer Eyeglasses Lens (폴리머 안경렌즈의 반사방지 코팅효과 연구)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.216-221
    • /
    • 2017
  • Reducing optical reflection in the visible light range, in order to increase the share of transmitted light and avoid the formation of ghost images in imaging, is important for polymer lens applications. In this study, polymer lenses with refractive indices of n=1.56, 1.60, and 1.67 were fabricated by the injection-molding method with a polymer lens monomer, dibutyltin dichloride as the catalyst and an alkyl phosphoric ester as the release agent. To investigate their anti-reflection (AR) effects, various AR coating structures, viz. a multi-layer AR coating structure, tri-layer AR coating structure with a discrete approximation Gaussian gradient-index profile, and tri-layer AR coating structure with a quarter-wavelength approximation, were designed and coated on the polymer lens by an E-beam evaporation system. The optical properties of the polymer lenses were characterized by UV-visible spectrometry. The material properties of the thin films, refractive index and surface roughness, were analyzed by ellipsometry and AFM, respectively. The most effective AR coating structure of the polymer lens with low refractive index, n=1.56, was the both side coating of multi-layer AR coating structure. However, both side coating of the tri-layered discrete approximation Gaussian gradient-index profile AR coating structure gave comparable results to the both side coating of the multi-layer AR coating structure for the polymer lens with a high refractive index of n=1.67.

Anti-Reflection Coating Technology Based High Refractive Index Lens with Ultra-Violet Rays Blocking Function (반사방지 코팅기술 기반 자외선 차단 기능의 고굴절률 안경렌즈)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.482-487
    • /
    • 2016
  • Ultra-violet rays are very harmful to eye health care. The blocking of ultra-violet rays and a reduction of optical reflection in the visible light range, which is to increase the share of transmitted light, and avoid the formation of ghost images in imaging, are important for the applications of polymer eyeglasses lenses. In this study, the high-refractive index polymer lenses, n=1.67, were fabricated by injection-molded method with the xylene diisocyanate monomer, 2,3-bis-1-propanethiol monomer, and benzotriazol UV absorber (SEESORB 709) mixture. To reduce the reflection of the polymer lens surfaces, multi-layer anti-reflection (AR) coatings were coated for both sides of the polymer lens using an E-beam evaporation system. The optical properties of the UV blocking polymer lens were characterized using a UV-visible spectrometer. The material properties of the thin films, which were composed AR coating layers, refractive index, and surface roughness, were analyzed by ellipsometry and atomic force microscopy. As a result, the fabricated polymer lens perfectly blocked ultra-violet rays below 395 nm with a blocking rate greater than 99%.