• Title/Summary/Keyword: Imaging optical system

Search Result 587, Processing Time 0.026 seconds

Tiny Pores Observed by New Solar Telescope and Hinode

  • Cho, Kyung-Suk;Bong, Su-Chan;Chae, Jong-Chul;Kim, Yeon-Han;Park, Young-Deuk;Ahn, K.;Katsukawa, Y.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.37.2-37.2
    • /
    • 2011
  • Our previous study on tiny pores (R < 2") observed by HINODE/Solar Optical Telescope (SOT) revealed that the plasma in the pores at the photosphere is always moving down and the pores are surrounded by the strong downward motions (highly red-shifted) of neighboring granulations. From this study, we speculated that the flow motions above the pore should be related with the motions at the photosphere, since the pore is strong magnetic field region. Meanwhile, SNU and KASI installed Fast Imaging Solar Spectrograph (FISS) in the Cude room of the 1.6 m New Solar Telescope (NST) at Big Bear Solar Observatory. FISS is a unique system that can do imaging of H-alpha and Ca II 8542 band simultaneously, which is quite suitable for studying of dynamics of chromosphere. To get some clue on the relationship between the photospheric and low-chromospheric motions at the pore region, we took a coordinate observation with NST/FISS and Hinode/SOT for new emerging active region (AR11117) on October 26, 2010. In the observed region, we could find two tiny pores and two small magnetic islands (SMIs), which have similar magnetic flux with the pores but does not look dark. Magnetic flux density and Doppler velocities at the photosphere are estimated by applying the center-of-gravity (COG) method to the HINODE/spectropolarimeter (SP) data. The line-of-sight motions above the photosphere are determined by adopting the bisector method to the wing spectra of Ha and CaII 8542 lines. As results, we found the followings. (1) There are upflow motion on the pores and downflow motion on the SMIs. (2) Towards the CaII 8542 line center, upflow motion decrease and turn to downward motion in pores, while the speed of down flow motion increases in the SMIs. (3) There is oscillating motion above pores and the SMIs, and this motion keep its pattern along the height. (4) As height increase, there is a general tendency of the speed shift to downward on pores and the SMIs. This is more clearly seen on the other regions of stronger magnetic field. In this talk, we will present preliminary understanding of the coupling of pore dynamics between the photosphere and the low-chromosphere.

  • PDF

Assessment of Seawater Color by Digital Photographic Imaging (수색표준액과 해면의 디지털 화상 분석에 의한 수색판정)

  • Choi, Sok-Jin;Arakawa, Hisayuki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.2
    • /
    • pp.171-178
    • /
    • 2009
  • The purpose of this study was the development of a digital water color measurement system using a CCD optical device. Photographs of the standard medium of Forel and Ule water color scales in the laboratory, and one of sea surface above a Secchi disc (Z=SD/2) immersed in seawater were taken. The colors of these pictures were estimated with the value of CIE $L^*a^*b^*$. Water color assessment was conducted with a digital photo-image. In the case of the Forel scale (No. 1-11), the $b^*$ value was so high that the water color number was large. In the Ule scale (No.11-21), the $a^*$ value became high, which is why the number on the water color scale was large. The color of these pictures showed that the $a^*$ value in the Forel scale and the $b^*$ value in the Ule scale increase with the increase of the F value. The $a^*$ value of seawater color was always lower than the one on the Forel and Ule water color scales. This indicates that the color of the scales differs from actual seawater color. It was concluded that water color number can more effectively be assessed by estimating the ${\Delta}Eab^*$ color difference between the water scales and actual seawater color.

Display System on a Tabletop for Two Viewers (2방향 관찰면 테이블형 디스플레이 시스템)

  • Yoon, Ki-Hyuk;Kim, Sung-Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.255-263
    • /
    • 2012
  • In this paper, we designed a tabletop display which enables two viewers each to see a different image simultaneously within his/her defined viewing zone. In order to construct the designed viewing zones, we found the basic design conditions for a parallax barrier with a commercial LCD panel. As the viewing zones for two viewers are formed with only two view-point design, the interval between the center positions of each viewing zone and the width of each viewing zone are small compared to designed values. We analyzed the primary cases, introduced two modified design methods to enlarge the interval and the width of the viewing zones, and simulated their characteristics. As designed with six unit view-point and each viewing zone of each viewer is formed with a merged view-point, we found that adequate interval and width of viewing zones can be made, and we verified it in comparison with the tabletop display module that we fabricated.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

A Wide Dynamic Range CMOS Image Sensor Based on a Pseudo 3-Transistor Active Pixel Sensor Using Feedback Structure

  • Bae, Myunghan;Jo, Sung-Hyun;Lee, Minho;Kim, Ju-Yeong;Choi, Jinhyeon;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.413-419
    • /
    • 2012
  • A dynamic range extension technique is proposed based on a 3-transistor active pixel sensor (APS) with gate/body-tied p-channel metal oxide semiconductor field effect transistor (PMOSFET)-type photodetector using a feedback structure. The new APS consists of a pseudo 3-transistor APS and an additional gate/body-tied PMOSFET-type photodetector, and to extend the dynamic range, an NMOSFET switch is proposed. An additional detector and an NMOSFET switch are integrated into the APS to provide negative feedback. The proposed APS and pseudo 3-transistor APS were designed and fabricated using a $0.35-{\mu}m$ 2-poly 4-metal standard complementary metal oxide semiconductor (CMOS) process. Afterwards, their optical responses were measured and characterized. Although the proposed pixel size increased in comparison with the pseudo 3-transistor APS, the proposed pixel had a significantly extended dynamic range of 98 dB compared to a pseudo 3-transistor APS, which had a dynamic range of 28 dB. We present a proposed pixel that can be switched between two operating modes depending on the transfer gate voltage. The proposed pixel can be switched between two operating modes depending on the transfer gate voltage: normal mode and WDR mode. We also present an imaging system using the proposed APS.

Alignment of Microbeads Using Spinning Helical Minichannel Cartridge (회전하는 나선형 미니채널 카트리지를 이용한 미세입자 정렬)

  • Kim, Subin;Prasad, Bibin;Kim, Jung Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.3
    • /
    • pp.38-45
    • /
    • 2016
  • Separation of particles based on different sizes, detection of pathogenic bacteria and isolation of leukocytes from whole blood are typical applications of spiral or helical microchannels. The present study focuses on developing a CD4+ T-cell counting device for monitoring HIV/AIDS patients with the aid of a helical minichannel used for a sample cartridge. For the experiment, $10{\mu}m$ sized microbeads were used for visualization with a fluorescence imaging system. Alignment of microbeads was investigated in a stationary and spinning sample cartridge filled with glycerol-water mixtures of different densities. The helical minichannel was spun using a DC motor controlled by an Arduino board with a Bluetooth shield. It was found that when the sample cartridge was made stationary, no bead alignment was achieved for a medium with density (0% and 20% glycerol) lower than that of the beads, but when it was spun at 2000-3000 rpm for 1-4 min, an alignment was obtained at the top of the channel facilitating optical detection and enumeration of those microbeads. Since an alignment of microbeads was achieved for a medium with density as that of blood plasma, the same approach can be applied for aligning and counting CD4+ T-lymphocytes in whole blood samples collected from patients.

IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM (Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도)

  • Kim, Bong-Chul;Lee, Chae-Eun;Park, Won-Se;Kang, Jeong-Wan;Yi, Choong-Kook;Lee, Sang-Hwy
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

Aerial Scene Labeling Based on Convolutional Neural Networks (Convolutional Neural Networks기반 항공영상 영역분할 및 분류)

  • Na, Jong-Pil;Hwang, Seung-Jun;Park, Seung-Je;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.6
    • /
    • pp.484-491
    • /
    • 2015
  • Aerial scene is greatly increased by the introduction and supply of the image due to the growth of digital optical imaging technology and development of the UAV. It has been used as the extraction of ground properties, classification, change detection, image fusion and mapping based on the aerial image. In particular, in the image analysis and utilization of deep learning algorithm it has shown a new paradigm to overcome the limitation of the field of pattern recognition. This paper presents the possibility to apply a more wide range and various fields through the segmentation and classification of aerial scene based on the Deep learning(ConvNet). We build 4-classes image database consists of Road, Building, Yard, Forest total 3000. Each of the classes has a certain pattern, the results with feature vector map come out differently. Our system consists of feature extraction, classification and training. Feature extraction is built up of two layers based on ConvNet. And then, it is classified by using the Multilayer perceptron and Logistic regression, the algorithm as a classification process.

The Performance of Flight Model of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Moon, Bongkon;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Ko, Kyeongyeon;Kim, Mingyu;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.58.1-58.1
    • /
    • 2017
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) is the near-infrared spectro-photometric instrument optimized to the first Next Generation of small satellite (NEXTSat-1). The off-axis optics was developed to cover a wide field of view with 2 deg. ${\times}$ 2 deg. as well as a wide wavelength range from 0.95 to $2.5{\mu}m$. Considering the simple alignment scheme, afocal system was adapted in the optical components. The mechanical structures were tested under the space environment. We have obtained the accurate calibration data using our test facilities under the operational condition. After the final integration of flight model into the satellite, the communication with the satellite and the functional test were passed. The NISS will be launched in early 2018. During around 2-year operation, the spectro-photometric survey covering more than 100 square degree will be performed. To achieve the major scientific objectives for the study of the cosmic star formation in local and distant universe, the main observational targets will be nearby galaxies, galaxy clusters, star-forming regions and low background regions. Here, we report the final performance of the flight model of the NISS.

  • PDF

Radial Variations in the Lengths of Wood Fibers and Vessel Elements in the Stem of Chestnut (Castanea crenata) Grown in Korea (국내산 밤나무 수간 내 목섬유 및 도관요소 길이의 방사방향 변이성)

  • Lee, Seon-Hwa;Kwon, Sung-Min;Lee, Sung-Jae;Febrianto, Fauzi;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.490-497
    • /
    • 2010
  • Radial variations in the lengths of wood fibers and vessel elements in the stem of chestnut (Castanea crenata) grown in Korea were investigated to get some fundamental information for efficient use of wood. Seven chestnut cultivars (Tanzawa, Ibuki, Arima, Ginyose, Tsukuba, Riheiguri, and Mansung) were examined in this study. The lengths of wood fibers and vessel elements were measured and analyzed by an optical microscope and an imaging analysis system. In all chestnut cultivars, the wood fiber length of latewood was longer than that of earlywood, and increased with the increase of growth ring number. Similarly, vessel element length of latewood was longer than that of earlywood, and showed increasing tendency with the increase of growth ring number. Consequently, it was considered that the lengths of wood fibers and vessel elements could be used for separating juvenile wood from adult wood in the chestnut stem.