• 제목/요약/키워드: Imaging agents

검색결과 178건 처리시간 0.04초

Context-Awareness for Ubiquitous Computing System

  • Kang, Dong-Hoon;Ahn, Sang-Chul;Ko, Hee-Dong;Cho, We-Duke;Park, Young-Tack
    • 한국지능정보시스템학회:학술대회논문집
    • /
    • 한국지능정보시스템학회 2004년도 추계학술대회
    • /
    • pp.158-161
    • /
    • 2004
  • In this paper, we propose a level of contexts such as low level and high level contexts, and its criteria of categorization are the existence of interaction and composite process done by the inference mechanism. When there is no matching high level service for the associated high level context, this context is described as meaningless. If the services cannot be provided with the entities by the system, this situational information is of little consequence. To provide services with the entities, we propose "community computing" architectural concept which provide the high level service to a group of agents in a community, and can be managed by the service scenario

  • PDF

Synthesis of Novel 18F-Labeled-Nitroimidazole-Based Imaging Agents for Hypoxia: Recent Advances

  • Anh Thu Nguyen;Hee-Kwon Kim
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.83-93
    • /
    • 2023
  • Hypoxia indicates the condition of low oxygen levels in tissues. In oncology, hypoxia can induce cancer progression and metastasis, as well as cause resistance to cancer therapies. The detection of hypoxia by using molecular imaging, particularly, positron emission tomography (PET) has been extensively studied due to many advantages. Nitroimidazoles, the moieties that can be trapped in hypoxic tissues due to selective reduction, have been used to design and synthesize of hypoxia-targeting radiopharmaceuticals. This review provides a summary of synthetic routes towards 18F-labeled-nitroimidazole radiotracers for PET imaging of hypoxia.

진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기: 이론적 고찰 (Magnitudes of the Harmonic Components Emitted from Utrasonic Contrast Agents in Response to a Diagnostic Utrasound: Theoretical Consideration)

  • 강관석;유지철;팽동국;임성민;최민주
    • 한국음향학회지
    • /
    • 제24권2호
    • /
    • pp.78-86
    • /
    • 2005
  • 진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기를 이론적으로 고찰하였다. 본 연구에서는 2 MHz 진단용 초음파 펄스에 의한 초음파 조영제의 비선형 동적 반응을 Gilmore Model을 이용하여 수치 해석하였다. 초음파 조영제의 탄성 효과는 무시하였다. 초음파 조영제 반경의 크기 (1-9 $\mu$m)와 초음파의 MI 값 (0.125-8)을 변화시키면서 발생된 서브, 울트라. 2차 하모닉 성분의 파워를 기본 주파수 성분과 비교하였다. 시뮬레이션 결과, 초음파 조영제가 공진 반경 (2 $\mu$m) 보다 클 경우, 초음파 조영제에서 방출하는 서브 하모닉의 파워가 기본 주파수 것 보다 압도적으로 크게 나타났다. 특히 하모닉 영상에서 사용하는 2차 하모닉의 파워는 서브 및 울트라 하모닉 성분 보다 낮은 값을 가지는 것으로 예측되었다. 본 연구 결과는 초음파 조영제를 이용하여 하모닉 영상을 구현할 경우, 서브 및 울트라 하모닉 성분이 2차 하모닉 성분 보다 우수한 영상 변수가 될 수 있음을 시사한다.

[18F]FET PET is a useful tool for treatment evaluation and prognosis prediction of anti-angiogenic drug in an orthotopic glioblastoma mouse model

  • Kim, Ok-Sun;Park, Jang Woo;Lee, Eun Sang;Yoo, Ran Ji;Kim, Won-Il;Lee, Kyo Chul;Shim, Jae Hoon;Chung, Hye Kyung
    • Laboraroty Animal Research
    • /
    • 제34권4호
    • /
    • pp.248-256
    • /
    • 2018
  • O-2-$^{18}F$-fluoroethyl-l-tyrosine ($[^{18}F]FET$) has been widely used for glioblastomas (GBM) in clinical practice, although evaluation of its applicability in non-clinical research is still lacking. The objective of this study was to examine the value of $[^{18}F]FET$ for treatment evaluation and prognosis prediction of anti-angiogenic drug in an orthotopic mouse model of GBM. Human U87MG cells were implanted into nude mice and then bevacizumab, a representative anti-angiogenic drug, was administered. We monitored the effect of anti-angiogenic agents using multiple imaging modalities, including bioluminescence imaging (BLI), magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET/CT). Among these imaging methods analyzed, only $[^{18}F]FET$ uptake showed a statistically significant decrease in the treatment group compared to the control group (P=0.02 and P=0.03 at 5 and 20 mg/kg, respectively). This indicates that $[^{18}F]FET$ PET is a sensitive method to monitor the response of GBM bearing mice to anti-angiogenic drug. Moreover, $[^{18}F]FET$ uptake was confirmed to be a significant parameter for predicting the prognosis of anti-angiogenic drug (P=0.041 and P=0.007, on Days 7 and 12, respectively, on Pearson's correlation; P=0.048 and P=0.030, on Days 7 and 12, respectively, on Cox regression analysis). However, results of BLI or MRI were not significantly associated with survival time. In conclusion, this study suggests that $[^{18}F]FET$ PET imaging is a pertinent imaging modality for sensitive monitoring and accurate prediction of treatment response to anti-angiogenic agents in an orthotopic model of GBM.

Tumor Imaging by Monoclonal Antibodies Labeled with Radioactive Metal Ions

  • Endo, K.;Sakahara, H.;Nakashima, T.;Koizumi, M.;Kunimatsu, M.;Ohta, H.;Furukawa, T.;Ohmomo, Y.;Arano, Y.;Yokoyama, A.;Okada, K.;Yoshida, O.;Hosoi, S.
    • 대한핵의학회지
    • /
    • 제18권2호
    • /
    • pp.77-85
    • /
    • 1984
  • Monoclonal antibodies have become widely investigated in the Nuclear Oncology, especially in the radioimmunosassay of tumor markers and in vivo radioimmunoimaging of cancer. However, there are numerous factors as to whether radioimmunoimaging will ultimately successful. For imaging of tumors, metallic radionuclides such as In-111, Ga-67, Tc-99m have favorable nuclear properties than widely used I-131. These radioistopes have characteristics of the useful radiation for imaging, convenient short half-lives and the simple and rapid radiolabeling of monoclonal antibodies by using bifunctional chelaing agents. The obtained chelate-tagged antibodies are quite stable both in vitro and in vivo, without interfering antibody activities and animal experiments provided a good basis for its clinical applicability for the radioimmunoimaging of cancer. Much attention has also been given to the possibility, only beginning to be exploited, of the specific treatment of malignant neoplasms with these agents. Although specific antibody has not been developed that is uniquely specific for cancer alone and there are still many questions to be answered and problems to be overcome before radioimmunoimaging can be successfully used in ptients with cancer, these methods can be applied to the coupling of monoclonal antibodies with anti-neoplastic drugs or radionuclides suitable for internal radiation therapy of cancer.

  • PDF

High-Resolution 3-D Refractive Index Tomography and 2-D Synthetic Aperture Imaging of Live Phytoplankton

  • Lee, SangYun;Kim, Kyoohyun;Mubarok, Adam;Panduwirawan, Adisetyo;Lee, KyeoReh;Lee, Shinhwa;Park, HyunJoo;Park, YongKeun
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.691-697
    • /
    • 2014
  • Optical measurements of the morphological and biochemical imaging of phytoplankton are presented. Employing quantitative phase imaging techniques, 3-D refractive index maps and high-resolution 2-D quantitative phase images of individual live phytoplankton are simultaneously obtained without exogenous labeling agents. In addition, biochemical information of individual phytoplankton including volume, mass, and density of individual phytoplankton are also quantitatively obtained from the measured refractive index distributions. We expect the present method to become a powerful tool for the study of phytoplankton.

Contribution of Microbleeds on Microvascular Magnetic Resonance Imaging Signal

  • Chang Hyun Yoo;Junghwan Goh;Geon-Ho Jahng
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.88-100
    • /
    • 2022
  • Purpose: Cerebral microbleeds are more susceptible than surrounding tissues and have been associated with a variety of neurological and neurodegenerative disorders that are indicative of an underlying vascular pathology. We investigated relaxivity changes and microvascular indices in the presence of microbleeds in an imaging voxel by evaluating those before and after contrast agent injection. Methods: Monte Carlo simulations were run with a variety of conditions, including different magnetic field strengths (B0), different echo times, and different contrast agents. ΔR2* and ΔR2 and microvascular indices were calculated with varying microvascular vessel sizes and microbleed loads. Results: As B0 and the concentration of microbleeds increased, 𝜟R2* and 𝜟R2 increased. 𝜟R2* increased, but 𝜟R2 decreased slightly as the vessel radius increased. When the vessel radius was increased, the vessel size index (VSI) and mean vessel diameter (mVD) increased, and all other microvascular indices except mean vessel density (Q) increased when the concentration of microbleeds was increased. Conclusions: Because patients with neurodegenerative diseases often have microbleeds in their brains and VSI and mVD increase with increasing microbleeds, microbleeds can be altered microvascular signals in a voxel in the brain of a neurodegenerative disease at 3T magnetic resonance imaging.

The Effect of Contrast Agent on the Change of Hepatic Uptake of 99mTc-Mebrofenin in Patients with Liver Transplantation

  • Seung-Hun Yeom;Sang-Hyeong Kil;Yeong-Hyeon Lim;Gwang-Yeol Park;Gyeong-Nam Cho;Seong-Muk Cho;Ji-Ho Seong
    • 핵의학기술
    • /
    • 제28권1호
    • /
    • pp.23-29
    • /
    • 2024
  • Purpose: 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) is an important and clinically useful diagnostic imaging study for detecting complications after liver transplantation. CT contrast agents due to their high atomic numbers, lead to a decrease in gamma ray count rates. This study investigated the impact of CT contrast agents on the uptake of 99mTc-mebrofenin in the liver. Materials and Methods: The quantitative HBS was performed on sixty-two liver transplantation patients (male:female=36:26), with a mean age of 59.4±6.4 years. Statistical comparison of hepatic uptake reduction ratio (HURR%) before and after the injection of CT contrast agents was performed using a paired t-test. Results: Hepatic uptake of the reduction ratio was 94.47±3.65% for the pre-CT contrast agents and 92.17±4.00% for the post-CT contrast agents. HURR% after CT contrast agent injection showed a statistically significant difference compared to before the injection (t=11.09, P<0.001). Conclusion: It will be necessary to pay attention when examining the HBS of patients with liver transplantation after the injection of CT contrast medium. It is advisable to schedule the examination on a different day to prevent residual contrast medium in the body from interfering with the quantitative evaluation of the nuclear medicine examination.

Intraindividual Comparison of Hepatocellular Carcinoma Washout between MRIs with Hepatobiliary and Extracellular Contrast Agents

  • Yeun-Yoon Kim;Young Kon Kim;Ji Hye Min;Dong Ik Cha;Jong Man Kim;Gyu-Seong Choi;Soohyun Ahn
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.725-734
    • /
    • 2021
  • Objective: To intraindividually compare hepatocellular carcinoma (HCC) washout between MRIs using hepatobiliary agent (HBA) and extracellular agent (ECA). Materials and Methods: This study included 114 prospectively enrolled patients with chronic liver disease (mean age, 55 ± 9 years; 94 men) who underwent both HBA-MRI and ECA-MRI before surgical resection for HCC between November 2016 and May 2019. For 114 HCCs, the lesion-to-liver visual signal intensity ratio (SIR) using a 5-point scale (-2 to +2) was evaluated in each phase. Washout was defined as negative visual SIR with temporal reduction of visual SIR from the arterial phase. Illusional washout (IW) was defined as a visual SIR of 0 with an enhancing capsule. The frequency of washout and MRI sensitivity for HCC using LR-5 or its modifications were compared between HBA-MRI and ECA-MRI. Subgroup analysis was performed according to lesion size (< 20 mm or ≥ 20 mm). Results: The frequency of portal venous phase (PP) washout with HBA-MRI was comparable to that of delayed phase (DP) washout with ECA-MRI (77.2% [88/114] vs. 68.4% [78/114]; p = 0.134). The frequencies were also comparable when IW was allowed (79.8% [91/114] for HBA-MRI vs. 81.6% [93/114] for ECA-MRI; p = 0.845). The sensitivities for HCC of LR-5 (using PP or DP washout) were comparable between HBA-MRI and ECA-MRI (78.1% [89/114] vs. 73.7% [84/114]; p = 0.458). In HCCs < 20 mm, the sensitivity of LR-5 was higher on HBA-MRI than on ECA-MRI (70.8% [34/48] vs. 50.0% [24/48]; p = 0.034). The sensitivity was similar to each other if IW was added to LR-5 (72.9% [35/48] for HBA-MRI vs. 70.8% [34/48] for ECA-MRI; p > 0.999). Conclusion: Extracellular phase washout for HCC diagnosis was comparable between MRIs with both contrast agents, except for tumors < 20 mm. Adding IW could improve the sensitivity for HCC on ECA-MRI in tumors < 20 mm.

PET-Based Molecular Nuclear Neuro-Imaging

  • Kim, Jong-Ho
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.161-170
    • /
    • 2004
  • 분자영상은 살아있는 개체의 몸 속에서 일어나는 생물학적 반응이나 특정한 표적분자를 비관혈적이며 반복적으로 영상화하는 기술이다. 이를 위해서는 두 가지 기본 요소가 요구되는 바 하나는 관심 생물현상에 의해 농도나 분광특성이 변하는 분자영상용 추적자이며 다른 하나는 이런 추적자를 모니터링하는 장비이다. 분자 핵의학 영상기술은 이제 신경과학분야에서도 활발히 적용되고 있으며 신경관련 기초연구나 뇌질환 관련 신약개발에 이미 중요한 역할을 하고 있다. 최근에는 살아있는 개체에서 약제 투여가 뇌에 미치는 약물학적, 생리적 영향을 조사하는 데에도 이용되고 있다. 다가오는 미래에는 각종 뇌질환에서 특이적 표적을 공략하는 새로운 분자치료가 개발되어 뇌질환 치료에 혁명적인 변화를 가져올 것으로 예상되고 있다. 그 예로, 파킨슨씨 병과 같은 퇴행성 신경질환에 줄기세포를 이용한 자가수선, 신경보호, 약물분비 치료, 성장인자와의 병행치료 등이 개발되고, 유전자 치료도 이용될 것으로 보인다. 신경 분자 핵의학 영상은 이와 같은 새로운 뇌질환 치료기술의 개발에 있어서 뇌 안에서 일어나는 분자수준의 변화를 실시간으로 모니터링함으로써 관련연구에 크게 기여할 것으로 기대된다.