• Title/Summary/Keyword: Imaging Processing Technique

Search Result 188, Processing Time 0.029 seconds

Investigation of Perfusion-weighted Signal Changes on a Pulsed Arterial Spin Labeling Magnetic Resonance Imaging Technique: Dependence on the Labeling Gap, Delay Time, Labeling Thickness, and Slice Scan Order (동맥스핀표지 뇌 관류 자기공명영상에서 라벨링 간격 및 지연시간, 표지 두께, 절편 획득 순서의 변화에 따른 관류 신호변화 연구)

  • Byun, Jae-Hoo;Park, Myung-Hwan;Kang, Ji-Yeon;Lee, Jin-Wan;Lee, Kang-Won;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.108-118
    • /
    • 2013
  • Currently, an arterial spin labeling (ASL) magnetic resonance imaging (MRI) technique does not routinely used in clinical studies to measure perfusion in brain because optimization of imaging protocol is required to obtain optimal perfusion signals. Therefore, the objective of this study was to investigate changes of perfusion-weighed signal intensities with varying several parameters on a pulsed arterial spin labeling MRI technique obtained from a 3T MRI system. We especially evaluated alternations of ASL-MRI signal intensities on special brain areas, including in brain tissues and lobes. The signal targeting with alternating radiofrequency (STAR) pulsed ASL method was scanned on five normal subjects (mean age: 36 years, range: 29~41 years) on a 3T MRI system. Four parameters were evaluated with varying: 1) the labeling gap, 2) the labeling delay time, 3) the labeling thickness, and 4) the slice scan order. Signal intensities were obtained from the perfusion-weighted imaging on the gray and white matters and brain lobes of the frontal, parietal, temporal, and occipital areas. The results of this study were summarized: 1) Perfusion-weighted signal intensities were decreased with increasing the labeling gap in the bilateral gray matter areas and were least affected on the parietal lobe, but most affected on the occipital lobe. 2) Perfusion-weighted signal intensities were decreased with increasing the labeling delay time until 400 ms, but increased up to 1,000 ms in the bilateral gray matter areas. 3) Perfusion-weighted signal intensities were increased with increasing the labeling thickness until 120 mm in both the gray and white matter. 4) Perfusion-weighted signal intensities were higher descending scans than asending scans in both the gray and white matter. We investigated changes of perfusion-weighted signal intensities with varying several parameters in the STAR ASL method. It should require having protocol optimization processing before applying in patients. It has limitations to apply the ASL method in the white matter on a 3T MRI system.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Quality Assessment of Beef Using Computer Vision Technology

  • Rahman, Md. Faizur;Iqbal, Abdullah;Hashem, Md. Abul;Adedeji, Akinbode A.
    • Food Science of Animal Resources
    • /
    • v.40 no.6
    • /
    • pp.896-907
    • /
    • 2020
  • Imaging technique or computer vision (CV) technology has received huge attention as a rapid and non-destructive technique throughout the world for measuring quality attributes of agricultural products including meat and meat products. This study was conducted to test the ability of CV technology to predict the quality attributes of beef. Images were captured from longissimus dorsi muscle in beef at 24 h post-mortem. Traits evaluated were color value (L*, a*, b*), pH, drip loss, cooking loss, dry matter, moisture, crude protein, fat, ash, thiobarbituric acid reactive substance (TBARS), peroxide value (POV), free fatty acid (FFA), total coliform count (TCC), total viable count (TVC) and total yeast-mould count (TYMC). Images were analyzed using the Matlab software (R2015a). Different reference values were determined by physicochemical, proximate, biochemical and microbiological test. All determination were done in triplicate and the mean value was reported. Data analysis was carried out using the programme Statgraphics Centurion XVI. Calibration and validation model were fitted using the software Unscrambler X version 9.7. A higher correlation found in a* (r=0.65) and moisture (r=0.56) with 'a*' value obtained from image analysis and the highest calibration and prediction accuracy was found in lightness (r2c=0.73, r2p=0.69) in beef. Results of this work show that CV technology may be a useful tool for predicting meat quality traits in the laboratory and meat processing industries.

Development of Non-Destructive Sorting Technique for Viability of Watermelon Seed by Using Hyperspectral Image Processing (초분광 영상기술을 이용한 수박종자 발아여부 비파괴 선별기술 개발)

  • Bae, Hyungjin;Seo, Young-Wook;Kim, Dae-Yong;Lohumi, Santosh;Park, Eunsoo;Cho, Byoung-Kwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.35-44
    • /
    • 2016
  • Seed viability is one of the most important parameters that is directly related with seed germination performance and seedling emergence. In this study, a hyperspectral imaging (HSI) system having a range of 1000-2500 nm was used to classify viable watermelon seeds from nonviable seeds. In order to obtain nonviable watermelon seeds, a total of 96 seeds were artificially aged by immersing the seeds in hot water ($25^{\circ}C$) for 15 days. Further, hyperspectral images for 192 seeds (96 normal and 96 aged) were acquired using the developed HSI system. A germination test was performed for all the 192 seeds in order to confirm their viability. Spectral data from the hyperspectral images of the seeds were extracted by selecting pixels from the region of interest. Each seed spectrum was averaged and preprocessed to develop a classification model of partial least square discriminant analysis (PLS-DA). The developed PLS-DA model showed a classification accuracy of 94.7% for the calibration set, and 84.2% for the validation set. The results demonstrate that the proposed technique can classify viable and nonviable watermelon seeds with a reasonable accuracy, and can be further converted into an online sorting system for rapid and nondestructive classification of watermelon seeds with regard to viability.

Measurement of the Skin Blood Flow using Cross-Correlation (Cross-Correlation법에 의한 피부 혈류속도 측정)

  • Lee, Jeong-Taek;Im, Chun-Seong;Ryu, Jeom-Su;Lee, Jong-Su;Gong, Seong-Bae;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.379-384
    • /
    • 1998
  • To measure precisely the blood velocity in the skin microcirculation, we have used time domain correlation (called Cross-Correlation) based on the processing of the backscattered RF signal obtained with a wideband echographic imaging transducer, although it is difficulties of adaptation of the pulsed wave system, because of the data processing in real time and the hardware problem. This dedicated technology based on a 20MHz echographic imaging system has been developed. We present how the experimental data, i.e. the backscattered RF signal, have to be analyzed. After RF lines realignment, stationary echo canceling procedure and correlation level control, a velocity profile has been obtained. In-vitro result show that velocity measurements as low as 0.1mm/sec attainable with a 80${\mu}m$ in axial resolution. We have also validated with in-vivo experimentation on the external ear of a rabbit using B-mode sector scanning image and M-mode image of a custom made 20MHz skin image system. The flow of the "auriculares caudales" vein, a microvessel of 600 m diameter, has been detected and studied. This technique will allow a more precise exploration of circulatory troubles in cutaneous pathologies.

  • PDF

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method (비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가)

  • Kwak, Nam-Su;Lee, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6432-6439
    • /
    • 2014
  • The NAUT (Non-contact Air coupled Ultrasonic Testing) technique is one of the ultrasonic testing methods that enables non-contact ultrasonic testing by compensating for the energy loss caused by the difference in acoustic impedance of air with an ultrasonic pulser receiver, PRE-AMP and high-sensitivity transducer. As the NAUT is performed in a state of steady ultrasonic transmission and reception, testing can be performed on materials of high or low temperatures or specimens with a rough surface or narrow part, which could not have been tested using the conventional contact-type testing technique. For this study, the internal defects of spot weld, which are often applied to auto parts, and CFRP parts, were tested to determine if it is practical to make the NAUT technique commercial. As the spot welded part had a high ultrasonic transmissivity, the result was shown as red. On the other hand, the part with an internal defect had a layer of air and low transmissivity, which was shown as blue. In addition, depending on the PRF (Pulse Repetition Frequency), an important factor that determines the measurement speed, the color sharpness showed differences. With the images obtained from CFRP specimens or an imaging device, it was possible to identify the shape, size and position of the internal defect within a short period of time. In this paper, it was confirmed in the above-described experiment that both internal defect detection and image processing of the defect could be possible using the NAUT technique. Moreover, it was possible to apply NAUT to the detection of internal defects in the spot welded parts or in CFRP parts, and commercialize its practical application to various fields.

Study of perception of the visual depth caused by the color correction (입체영상 제작에서 색 보정 결과가 입체감 인지에 미치는 영향 연구)

  • Han, Myung-Hee;Kim, Chee-Yong
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.177-184
    • /
    • 2010
  • These days, as digital producing technique has been developed, 3D imaging technique is used in high-tech computer and T.V. Also study for 3D producing technique is actively in progress. Moreover, as James Cameron's movie, 'Avatar' released in 2009 was a box office hit, the issue about 3D image came to the fore again. At this point, I decided to study the effect of the visual depth caused by the color correction during the post-production stage. The purpose of this study is to offer information about processing effective images through data about the effect of the visual depth that applies the color correction during the post-production stage. Basically, I supposed that color and contract would have effects on depth of 3D image. As a result, I could find out the changes of visual depth, space perception and sense of depth throughout the experiment. Applying this result,, I produced the 15 minutes of 3D advertisement movie and I found out that the color correction during the post-production stage was very effective for 3D depth. The left image and the right image by beam splitter based rig and parallel rig were used for this study. Also I adjusted the strong contrast by the color correction during the post-production stage after correcting convergence and visual depth during editing. As a result, I could produce images which had strong sense of space and sense of depth.

Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array (선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가)

  • Lee, D.H.;Hong, C.P.;Han, B.S.;Kim, H.J.;Suh, J.J.;Kim, S.H.;Lee, C.H.;Lee, M.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.