• Title/Summary/Keyword: Images quality

Search Result 3,235, Processing Time 0.029 seconds

Quantization Noise Reduction in Block-Coded Video Using the Characteristics of Block Boundary Area (블록 경계 영역 특성을 이용한 블록 부호화 영상에서의 양자화 잡음 제거)

  • Kwon Kee-Koo;Yang Man-Seok;Ma Jin-Suk;Im Sung-Ho;Lim Dong-Sun
    • The KIPS Transactions:PartB
    • /
    • v.12B no.3 s.99
    • /
    • pp.223-232
    • /
    • 2005
  • In this paper, we propose a novel post-filtering algorithm with low computational complexity that improves the visual quality of decoded images using block boundary classification and simple adaptive filter (SAF). At first, each block boundary is classified into smooth or complex sub-region. And for smooth-smooth sub-regions, the existence of blocking artifacts is determined using blocky strength. And simple adaptive filtering is processed in each block boundary area. The proposed method processes adaptively, that is, a nonlinear 1-D 8-tap filter is applied to smooth-smooth sub-regions with blocking artifacts, and for smooth-complex or complex-smooth sub-regions, a nonlinear 1-D variant filter is applied to block boundary pixels so as to reduce the blocking and ringing artifacts. And for complex-complex sub-regions, a nonlinear 1-D 2-tap filter is only applied to adjust two block boundary pixels so as to preserve the image details. Experimental results show that the proposed algorithm produced better results than those of conventional algorithms both subjective and objective viewpoints.

Optimizing the Drying Conditions of Surimi Snacks Using a Response Surface Methodology (반응표면분석법을 이용한 생선연육 스낵의 건조조건 최적화)

  • Kim, Seonghui;Chae, Jiyeon;Choi, Gibeom;Kim, Jongmin;Lee, Jiho;Kim, Seon-Bong;Kim, Young-Mog;Kim, Jin-Soo;Lee, Jung-Suck;Cho, Suengmok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.6
    • /
    • pp.571-579
    • /
    • 2019
  • Surimi has been widely investigated for developing fish snacks; however, few studies have examined the optimal drying conditions of surimi for fish snacks. This study used a response surface methodology to optimize the drying conditions for the overall acceptance of fish snacks. The drying temperature (X1, 51-65℃) and drying time (X2, 1.5-2.5 h) were chosen as independent variables. The dependent variables were overall acceptance (Y1, points), hardness (Y2, N), moisture content of the dried intermediate product (Y3, %), and volatile basic nitrogen of the fried final product (Y4, mg/100 g). The estimated optimal conditions for overall acceptance (Y1) were X1=64℃ and X2=2 h. The predicted values of the dependent variables at the optimal conditions were overall acceptance (Y1)=8.60 points, hardness (Y2)=10.07 N, and moisture content of the dried intermediate product (Y3)=10.00% and were similar to the experimental values. Scanning electron microscopy images revealed that the drying conditions affected the microstructure of the fish snacks. Our results could be used to increase the productivity of fish snacks made by small- and mid-sized seafood companies.

Turbo FLASH NRI Using Optimized Flip Angle Pattern: Application to Inversion-Recovery T1-Weighted Imaging (최적화된 Flip Angle Pattern을 사용한 Turbo FLASH MRI: Inversion-Recovery T1-Weighted Imaging에의 응용)

  • Oh, C.H.;Choi, H.J.;Yang, Y.J.;Lee, D.R.;Ryu, Y.C.;Hyun, J.H.;Kim, S.R.;Yi, Y.;Jung, K.J.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.55-56
    • /
    • 1998
  • The 3-D Fast Gradient Echo (Turbo FLASH, Turbo Fast Low Angle Shot) sequence is optimized to achieve a good T1 contrast using variable excitation flip angles. In Turbo FLASH sequence, depending on the contrast preparation scheme, various types of image contrast can be established. While proton density contrast is obtained when using a short repetition time with a short echo time and small flip angles, T1 or T2 weighting can be obtained with proper contrast preparation sequences applied before the above proton density Turbo FLASH sequence. To maximize the contrast to noise ratio while retaining a sharp impulse response (smooth frequency domain response), the excitation flip-angle pattern is optimized through simulation and experiments. The TI (the delay after the preparation sequence which is a 180 degree inversion RF pulse in the IR T1 weighted imaging case), TD (the delay time between the Turbo FLASH sequence and the next preparation), and TR are also optimized fur the best image quality. The proposed 3-D Turbo FLASH provides $1mm\times1mm\times1.5mm$ high resolution images within a reasonable 5-8 minutes of imaging time. The proposed imaging sequence has been implemented in a Medison's Magnum 1.0T system and verified through simulations as well as human volunteer imaging. The experimental results show the utility of the proposed method.

  • PDF

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

The Evaluation of Non-Ionizing Radiation (Near-Infrared Radiation) based Medical Imaging Application : Diabetes Foot (비전리 방사선 (근적외선) 기반 의료영상 활용 가능성 평가: 당뇨발)

  • Jung, Young-Jin;Shin, Cheol-Won;Ahn, Sung-Min;Hong, Jun-Yong;Ahn, Yun-Jin;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.399-406
    • /
    • 2016
  • Near-infrared radiation (NIR) is non-ionizing, non-invasive, and deep tissue penetration in biological material, thereby increasing research interests as a medical imaging technique in the world. However, the use of current near-infrared medical image is extremely limited in Korea (ROK) since it is not well known among radiologic technologists and radiological researchers. Therefore to strengthen the knowledge for NIR medical imaging is necessary so as to prepare a qualified radiological professionals to serve medical images in high-quality on the clinical sites. In this study, an overview of the features and principles of NIR imaging was demonstrated. The latest research topics and worldwide research trends were introduced for radiologic technologist to reinforce their technical skills. In particular, wound care and diabetic foot which have high feasibility for clinical translation were introduced in order to contribute to accelerating NIR research for developing the field of radiological science.

Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom (복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.407-414
    • /
    • 2016
  • This study is to minimize the patient dose and maintain the image quality according to change of source to image receptor distance and applying additional filter. In this study, we used the DR system, the tissue-equivalent abdomen phantom and the aluminium filter. The exposure conditions were set to 80 kVp using AEC mode. The collimation size was $16{\times}16inch$. The exposure dose were measured 10 times when the SID was changed with 100, 110, 120 and 130 cm, respectively. The pirana 657 for dosimeter was located on center of radiation irradiation. The acquired images were analyzed by using the image J. In the results, the tube current was increased with increasing the SID but ESD was decreased with increasing the SID. The decrease of ESD attribute to use of filter that remove the photon of lower energy. In the histogram results using image J, there were differences between the ESD and the exposure conditions according to change of SID. However, there were not differences in histogram. Therefore, the exposure dose could reduced when set the longer SID. For pediatric exam, the exposure dose could reduced when used the aluminium filter.

Characterization of CdS-quantum dot particles using sedimentation field-flow fractionation (SdFFF) (침강 장-흐름 분획법을 이용한 CdS 양자점 입자의 특성 분석)

  • Choi, Jaeyeong;Kim, Do-Gyun;Jung, Euo Chang;Kwen, HaiDoo;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • CdS-QD particles are a nano-sized semiconducting crystal that emits light. Their optical properties show great potential in many areas of applications such as disease-diagnostic reagents, optical technologies, media industries and solar cells. The wavelength of emitting light depends on the particle size and thus the quality control of CdS-QD particle requires accurate determination of the size distribution. In this study, CdS-QD particles were synthesized by a simple ${\gamma}$-ray irradiation method. As a particle stabilizer polyvinyl pyrrolidone (PVP) were added. In order to determine the size and size distribution of the CdS-QD particles, sedimentation field-flow fractionation (SdFFF) was employed. Effects of carious parameters including the the flow rate, external field strength, and field programming conditions were investigated to optimize SdFFF for analysis of CdS-QD particles. The Transmission electron microscopy (TEM) analysis show the primary single particle size was ~4 nm, TEM images indicate that the primarty particles were aggregated to form secondary particles having the mean size of about 159 nm. As the concentration of the stabilizer increases, the particle size tends to decrease. Mean size determined by SdFFF, TEM, and dynamic light scattering (DLS) were 126, 159, and 152 nm, respectively. Results showed SdFFF may become a useful tool for determination of the size and its distribution of various types of inorganic particles.

A Survey of Chinese Men's Purchase Attitude and Size Fitness of Ready-Made Suits - Centered on the Area of Ningbo in Zhejiang Province - (중국 남성(中國 男性)의 기성복 정장(旣成服 正裝)에 대한 구매태도(購買態度) 및 사이즈 적합성(適合性)에 관(關)한 실태 조사(實態 調査) - 절강성 영파 지역(浙江省 寧波 地域)을 중심(中心)으로 -)

  • Shim, Boo-Ja;Suh, Chu-Yeon;Kwon, Young-Ja;Kwon, Soon-Jeong
    • Journal of Fashion Business
    • /
    • v.10 no.2
    • /
    • pp.83-98
    • /
    • 2006
  • With the subjects of male consumers in their 20s to 40s living in the Ningbo area in Zhejiang Province, this study aims to investigate into the reality of their purchase attitude and size fitness of ready-made suits. The results are as follows; Looking into their demographic characteristics, 70.6% of the subjects were twenties, 60.6% were single, and educational career stood in the order of college, middle school, and high school graduation. They were largely absorbed in free trade, followed by teaching, commerce and service industry. 59.6% of them were Zhejiang Province belongs. One to two thousand yuan was the greatest portion of their monthly income. As for their purchase attitude of ready-made suits, they thought higher of material, quality, activity, and solidity than of design. They preferred to buy clothes at a department store. There was significant difference between purchase frequency and purchase price according to monthly income and jobs. Concerning brand recognition, the Chinese subjects favored "Youngor." Though Korea's brands were very lowly recognized, Korean products received really high recognition. Compared with China's brands, they found foreign brands excellent in design, followed by material/matter, wear, and sewing. As to their physical satisfaction and the size fitness of clothes, most subjects felt happy with their sizes. Trousers and jackets were among the unfitting suit items, while the girth of waist was the least satisfactory size. Therefore, in order to raise the market occupation rate of Korean suit goods in China, more aggressive marketing strategies are required to utilize the current Korean-style entertainment and maximize concerning brand images. In particular, outstanding products in consideration of prices should be made through the proper patternmaking to reflect the body types of the Chinese.

Optimization of Calcium Acetate Preparation from Littleneck Clam (Ruditapes philippinarum) Shell Powder and Its Properties (바지락(Ruditapes philippinarum) 패각분말로부터 초산칼슘 제조 및 특성)

  • Park, Sung Hwan;Jang, Soo Jeong;Lee, Hyun Ji;Lee, Gyoon-Woo;Lee, Jun Kyu;Kim, Yong Jung;Kim, Jin-Soo;Heu, Min Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.321-327
    • /
    • 2015
  • The optimal condition for preparation of powdered calcium acetate (LCCA) which has high solubility, from calcined powder (LCCP) of the littleneck clam shell by response surface methodology (RSM) was examined. Increased molar ratio of LCCP led to reduced solubility, yield, color values, and overall quality. The critical values of multiple response optimization of independent variables were 2.57 M of acetic acid and 1.57 M of LCCP. The actual values (pH 7.0, 96.1% for solubility, and 220.9% for yield) under the optimized condition were similar to the predicted values. LCCA showed strong buffering capacity between pH 4.89 and 4.92 on addition of ~2 mL of 1 N HCl. The calcium content and solubility of LCCA were 21.9-23.0 g/100 g and 96.1-100.1%, respectively. The FT-IR and XRD patterns of LCCA were identified as calcium acetate monohydrate, and FESEM images revealed an irregular and rod-like microstructure.