• Title/Summary/Keyword: Image uniformity

Search Result 261, Processing Time 0.024 seconds

The Effects of Reducing a Dose on the Genital Gland at a CT Scan on the Whole Abdomen According to the Shielding Material (Whole Abdomen CT촬영 시 차폐 재료에 따른 생식선 선량 감쇠 효과)

  • Gang, Eun Bo;Park, Cheol Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.419-425
    • /
    • 2016
  • The purpose of this study is to produce a shielding material to reduce a dose on the genital gland, one of the superficial organs, at a CT scan on the whole abdomen and hardly affect picture quality and examine its utility. This research made 22 mm silicone and 7.3 mm aluminum having the similar material quality and effect of previous bismuth. By using the non-shield, bismuth, 22 mm silicone, and 7.3 mm aluminum shielding materials, this author conducted a comparative experiment measuring the decay rate of the genital gland's exposure to radiation, change of the CT number and noise in the image, and the CT number, noise, and uniformity in the AAPM phantom. According to the results, exposure to radiation is reduced in bismuth as 29.96%, silicone 22 mm as 13.10%, and 7.3 mm aluminum as 18.27%. In bismuth, however, the image's CT number varies a lot, and uniformity is measured to be inappropriate in the AAPM phantom scan; therefore, it indicates great change in terms of picture quality in superficial organs like the genital gland. Concerning superficial organs like the genital gland, if 22 mm silicone and 7.3 mm aluminum are used as shielding materials, it will be helpful in reducing variation in picture quality and also decreasing radiation exposure to radiation.

A Study on the Characteristic and Droplet Uniformity of Spray Injection to Exhaust Gas Flow from Urea Solution Injector (Urea 수용액의 배기가스 유동장내 분무 특성과 분무 균일도에 관한 연구)

  • Oh, Jung-Mo;Cha, Won-Sim;Kim, Ki-Bum;Lee, Jin-Ha;Lee, Ki-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • Diesel engines can produce higher fuel efficiency and lower $CO_2$ emission, they are subject to ever more stringent emission regulation. However, there are two major emission concerns fo diesel engines like such as particulate matter (PM) and nitrogen oxides (NOx). Moreover, it is not easy to satisfy the regulations on the emission of NOx and PM, which are getting more strengthened. One of the solutions is to apply the new combustion concept using multistage injection such as HCCI and PCCI. The other solution is to apply after-treatment systems. For example, lean NOx trap catalyst, Urea-SCR and others have various advantages and disadvantages Especially, Urea-SCR system have advantages such as a high conversion efficiency and a wide operation conditions. Hence the key factor to implementation of Urea-SCR technology, good mixing of urea(Ammonia) and gas, reducing Ammonia slip. Urea mixer components are required to facilitate evaporation and mixing because the liquid state of urea poses significant barriers for evaporation, and the distance to mixer is the most critical that affect mixer performance. In this study, to find out the distance from injector to mixer and simulation factor, a laser diagnostics and high speed camera are used to analyze urea injector spray characteristics and to present a distribution of urea solution in transparent manifold In addition, Droplet Uniformity Index is calculated from the acquired images by using image processing method to clarify the distribution of spray.

Images of Costumes in Science Fiction Movies (공상 과학 영화에 나타난 복식이미지)

  • 김민자
    • Journal of the Korean Society of Costume
    • /
    • v.50
    • /
    • pp.51-68
    • /
    • 2000
  • This study is intended to examine the common features of costume images in science-fiction (SF) movies that deal with current socio-cultural situations by examining their themes and tones about the future it can be generally concluded that costume images of SF movies are divided into two patterns : one inheriting traditional styles constructed on linear progress and the other based on dismantiling the tradition. this analysis is made through the research of actual cinematic contexts on the common features of multiple styles shaping the two patterns of costume images. The results can be summarized as the following: The former is related with the future built up on the basis of belief in reasonal progress rooted in the Enlightenment reasonable plan for ideal social order and strong faith in uniformity. So It shows functional uniformity disregarding wasteful competitiveness in consumption and luxuriousness and clothing that has the aesthetic value of purity without emphasizing human body or sensuality are presented. On the other hand SF movies which show the uncertain costume image as the meaning of dismantling of tradition take up a rather critical view of assumption that society can move toward utopian future as it searches future images in the notion of hetero-topia by emphasizing pluralism consequently as for clothing diversity and uncertainty in post-modern style are presented destroying modernistic dichotomy and the assumption of Utopian clothing made in the notion of modern progressivism.

  • PDF

A Study on the Handle and Texture of Artificial Suede (인조 스웨이드의 handle 및 질감에 관한 연구)

  • 신경인;김종준
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.1
    • /
    • pp.128-137
    • /
    • 2000
  • A range of suede-like samples were collected including woven fabric type, nonwoven fabric type, and natural suede(sheep). The surface textures of these suede-like fabrics are rather diverse and different from the plain filament type fabrics since there are a lot of fine surface free fiber ends. Physical and mechanical measurements were carried using the KES equipments. Based on the Kawabata-Niwa translational equation, primary hand values and THV were calculated. Uniaxial tensile tests were performed. Using glossmeter, the reflectance pattern was analyzed at different incidence and receiving angles. In order to capture the surface images of the specimens, a CCD camera and frame grabber connected to a PC were employed. The reflectance uniformity of the images was measured with line-profile analysis and standard deviation values of the profile of the images were calculated. After the multiscale wavelet transfermation, correlation among the transformed image was analyzed at each scale. The reflectance uniformity of the natural suede was better than that of nonwoven type suede, while that of woven type suede was the last among the selected three samples(natural suede, nonwoven type, woven type). The correlation analysis among images has shown the possibility of using the wavelet transformation of the images as one of the measures to detect similarities among the textured specimens.

  • PDF

Design of a lighting system for PCB visual pattern inspection (인쇄회로기판의 패턴 검사용 조명장치 설계)

  • Na, Hyun-Chan;Rho, Byung-Ok;Ryu, Yung-Kee;Cho, Hyung-Suck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1997
  • Austomated visual inspection(AVI) capability has become an important key component in the automated manufacturing system. In such a visual inspection system an intensity(or color) image of a scene is quickly affected by optical property of objects, condition and roughness of surface, lens and filters, image sensor property and lighting system. In particular, the lighting system disign is the most important factor, since it affects overall performance of the visual system. For fast and cheap automated visual inspection system it is important to obtain the good image quality which results from careful attention to the design of the lighting system. In this paper, the lighting subsystem of AVI system is analysed for the inspection of printed circuit board(PCB) patterns. The spectral reflectance of materials, which are composed of PCB, is measured for choosing the light source. The reflection property is theoretically obtained by a reflection model and also obtained by experiments which measure intensity with varying the viewing direction of image sensor and the lighting direction of illuminator. The illumination uniformity of a ring-type illuminator. The lighting system is designed based upon the experimental results and theoretial analysis.

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

Characteristics of the Electro-Optical Camera(EOC)

  • Lee, Seung-Hoon;Shim, Hyung-Sik;Paik, Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.313-318
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of Korea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including Digital Terrain Elevation Map(DTEM). This instrument which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510 ~ 730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable rain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the EOC data users. The modulation transfer function of EOC was measured as greater than 16% at Nyquist frequency over the entire field of view which exceeds its requirement of larger than 10%, The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

  • PDF

Image Sensor Module for Detecting Space Illuminance in Indoor Environment (실내 환경의 공간조도 검출을 위한 이미지센서모듈)

  • Moon, Seong-Jae;Lim, Yeong-Seog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.771-778
    • /
    • 2019
  • The traditional illuminance intensity detection method using a single sensor has a problem that uniformity of illuminance detection is deteriorated depending on the measurement position due to the narrow FOV characteristic. In order to overcome this problem, a method of detecting an average illuminance value through a plurality of illuminance sensors is used, but the complexity and detection error are increased. In this paper, we propose a illuminance intensity detection method based on a single image sensor with wide FOV. The proposed method can solve the problems such as system complexity and error increase of existing illuminance sensor. The test results show that the difference of average value is 12% using a illuminance sensor, 10.7% using five illuminance sensors, and 6.2% using an image sensor compared with the reference value using the color difference illuminometer. It is confirmed that the proposed method can easily and accurately detect the space illuminance with improved uniformity.

Water body extraction in SAR image using water body texture index

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.4
    • /
    • pp.337-346
    • /
    • 2015
  • Water body extraction based on backscatter information is an essential process to analyze floodaffected areas from Synthetic Aperture Radar (SAR) image. Water body in SAR image tends to have low backscatter values due to homogeneous surface of water, while non-water body has higher backscatter values than water body. Non-water body, however, may also have low backscatter values in high resolution SAR image such as Kompsat-5 image, depending on surface characteristic of the ground. The objective of this paper is to present a method to increase backscatter contrast between water body and non-water body and also to remove efficiently misclassified pixels beyond true water body area. We create an entropy image using a Gray Level Co-occurrence Matrix (GLCM) and classify the entropy image into water body and non-water body pixels by thresholding of the entropy image. In order to reduce the effect of threshold value, we also propose Water Body Texture Index (WBTI), which measures simultaneously the occurrence of repeated water body pixel pair and the uniformity of water body in the binary entropy image. The proposed method produced high overall accuracy of 99.00% and Kappa coefficient of 90.38% in water body extraction using Kompsat-5 image. The accuracy analysis indicates that the proposed WBTI method is less affected by the choice of threshold value and successfully maintains high overall accuracy and Kappa coefficient in wide threshold range.

When Evaluated Using CT Imaging Phantoms AAPM Phantom Studies on the Quantitative Analysis Method (AAPM Phantom을 이용한 CT 팬텀 영상 평가 시 정량적 분석 방법에 관한 연구)

  • Kim, Young-Su;Ye, Soo-Young;Kim, Dong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.592-600
    • /
    • 2016
  • AAPM CT performance for special medical equipment quality control checks using a standard phantom for evaluation, using the evaluator's subjective assessment as to minimize errors due computerized assessment program to evaluate their usefulness. Phantom for evaluation AAPM CT Performance Phantom: was used, the default shooting conditions are the same as quality control checks. And, we use IMAGE J to evaluate the program. Quantitative evaluation with CT attenuation coefficient and the noise measurement, the uniformity measurement, the slice thickness measurement, contrast resolution of the measurement, a phantom image of the spatial resolution determined by the evaluation program is evaluated as self-extracting the result after processing the image, CT uniformity measurement for the evaluation that was smaller and the standard deviation of a video image processing more uniform slice thickness measurements it is difficult to evaluate due to the difference of the ratio of the measured value of the phantom image. Contrast resolution was measured cylindrical diameter 6th evaluate the shape of a circle obtained a mean value and a standard deviation of diameters, the spatial resolution of the group of source, including acceptance criteria automatically extracted result as a result of both the number of the extracted circularIt appeared. Evaluate the source image and video processing, and video to qualitative evaluation by gross were processed video image is shown excellent results. If the evaluators in order to minimize the errors of subjective judgment based on the results of the above should be done with a quantitative evaluation and qualitative evaluation utilizes a computerized assessment program is considered that further evaluation be made more efficient.