• 제목/요약/키워드: Image technique

검색결과 5,868건 처리시간 0.03초

휴대용 열 영상 관측 장비를 위한 전자적 영상 안정화 (Electronic Image Stabilization for Portable Thermal Image Camera)

  • 김종호
    • 한국군사과학기술학회지
    • /
    • 제19권3호
    • /
    • pp.288-293
    • /
    • 2016
  • Electronic Image Stabilization(EIS) is widely used as a technique for correcting a shake of an image. The case requiring the EIS function has been increased in high magnification thermal image observation on portable military equipment. Projection Algorithm(PA) for EIS is easy to implement but its performance is sensitive to the projection area. Especially, projection profiles of thermal image have very modest change and are difficult to extract image shifts between frames. In this paper, we proposed algorithm to extract a feature image for the thermal image and compared Block Matching Algorithm(BMA) with PA using our proposed feature image. When using our proposed feature image, BMA was simply implemented using FPGA's internal small memory. And we were able to obtain 30 % PSNR improved results compared to PA.

뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식 (Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.961-968
    • /
    • 2019
  • 본 연구는 CT를 이용한 뇌혈관 추출 검사에서 이중에너지 기법을 활용하여 각 에너지 준위별 뇌혈관 조영술의 유용성을 평가하였다. 방법은 CT 뇌혈관 조영술을 시행한 환자 15명의 DE 영상과 SE 영상을 대상으로 하였다. 영상의 분석은 MCA, 뇌실직 조직, Background에 ROI를 설정하여 평균값, 표준편차 및 SNR, CNR 값을 구하고, SE영상과 비슷하게 구현되는 에너지 영역을 알아보았다. Likert 5점 척도 육안평가를 병행한 결과 DE 40 keV와 SE 120 kVp에서 가장 선명한 MCA 영상을 확인 하였다(p>0.05). SE영상의 SNR 값은 DE영상의 40 keV에너지 준위값과 비슷하게 측정되었고, 40 keV와 50 keV의 저에너지 준위의 영상이 SNR이 높게 측정되어 고에너지 준위의 영상에 비해 대조도가 높아 뇌혈관질환을 유용하게 관찰할 수 있을 것으로 사료된다.

Parzen 윈도우 추정에 기반한 다중 초점 이미지 융합 기법 (Multi-focus Image Fusion Technique Based on Parzen-windows Estimates)

  • ;박대철
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.75-88
    • /
    • 2008
  • 본 논문은 입력 이미지 블록의 클래스 조건부 확률 밀도 함수의 커널 추정에 기반한 공간 영역에서의 다중초점 이미지 융합 기법을 제안한다. 이미지 융합 문제를 시험 패턴으로부터 추정된 유사 밀도 함수에 의해 사후 클래스 확률, P($w_{i}{\mid}B_{ikl}$),을 계산하는 분류 임무로 접근하였다. C개의 입력 이미지 $I_{i}$에 대하여 제안한 방법은 i 클래스 $w_{i}$를 정의하고 베이즈 결정 원리에 기초하여 판별 함수를 최대화하는 PxQ 블록 $B_{ikl}$의 집합에 의해 표현되는 결정 지도로 부터 융합 이미지 Z(k,l)를 형성한다. 출력 화질의 척도로서 RMSE 와 상호 정보량인 MI를 사용하여 제안한 기법의 성능이 평가되었다. 커널 함수의 폭 ${\sigma}$ 도 변화시키고, 다른 종류의 커널과 블록 크기를 변화시켜 가며 성능평가를 수행하였다. 제안한 가법은 C=2 와 C=3에 대하여 시험하였고 시험 결과는 좋은 성능을 보였다.

  • PDF

Usefulness of Temporal Subtraction for The Detection of Interval Changes of Interstitial Lung Diseases on Chest Radiographs

  • Higashida, Yoshiharu;Ideguchi, Tadamitsu;Muranaka, Toru;Akazawa, Fumio;Miyajima, Ryuichi;Tabata, Nobuyuki;Ikeda, Hirotaka;Ohki, Masafumi;Toyofuku, Fukai;Doi, Kunio
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.454-456
    • /
    • 2002
  • The evaluation of interval changes between temporally sequential chest radiographs is necessary for the detection of new abnormalities or interval changes, such as pulmonary nodules and interstitial disease. For interstitial lung disease, the interval changes are very important for diagnosis and treatment. Especially, interstitial lung disease may show rapid changes in the radiographs, show changes in the entire lung field in minute detail, or show changes in multiple parts depending on the type. It is therefore difficult to have an accurate grasp of the condition of the disease only with conventional radiographs. The temporal subtraction technique which was developed at the University of Chicago, provides a subtraction image of the current warped image and the previous image. A temporal subtraction image, shows only differences and changes between the two images, can be very useful for a diagnosis of interstitial lung disease. However, the evaluation of the temporal subtraction technique for interstitial lung disease using receiver operating characteristic(ROC) studies has not been reported yet. Therefore, we have evaluated the clinical usefulness of a temporal subtraction technique for detection of interval changes of interstitial lung disease by ROC analysis.

  • PDF

시간 경과 신경계 영상 시퀀스에서의 축삭돌기 추출 기법 (An Automated Technique for Detecting Axon Structure in Time-Lapse Neural Image Sequence)

  • 김낙현
    • 한국지능시스템학회논문지
    • /
    • 제24권3호
    • /
    • pp.251-258
    • /
    • 2014
  • 신경계 영상 해석의 목적은 움직이는 미토콘드리아들을 추적하여 그 속도와 이동 방향 등을 추출하는 것인데, 미토콘드리아의 움직임은 축삭돌기 상에서만 이루어지는 특징이 있다. 축삭돌기 추출 작업은 일반적으로 수작업을 동반한 처리 과정을 통해 이루어지고 있는데, 본 논문에서는 자동화된 축삭돌기 추출 기법을 제안한다. 우선 전체 비디오 프레임 영상에서 각 픽셀의 최대값을 취해 통합영상을 구한다. 통합 영상에서 축삭돌기는 능선 구조를 보이는데, 능선을 검출하기 위해 본 연구에서는 능선 강화 필터링과 피크 검출 과정을 적용하였다. 또한 검출된 능선점에서 나타난 오류를 제거하기 위해 대해 각 능선점 주위에서 신뢰도 함수를 사용한 필터링을 적용한다. 실제 영상을 이용한 실험을 통해 제안된 방식은 높은 검출률과 정확도를 나타내는 것을 확인하였다.

홍삼 내공검출을 위한 X-선 영상처리기술(I) - 내공검출에 적합한 전처리기법 - (X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection ( I ) - Preprocessing technique for inner hole detection -)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Journal of Biosystems Engineering
    • /
    • 제27권4호
    • /
    • pp.341-348
    • /
    • 2002
  • Quality evaluation of red ginsengs is determined by outer shape and inner qualities. Especially, the inner qualities are main grading criteria. Currently, red ginsengs are classified into 3-grades; heaven, earth and good. The best heaven grade must not include inner holes and sponge tissues. This study was conducted to develop a red ginseng sorting system using x-ray image processing technique. Because of lens characteristic, gray values of the central region in the x-ray image are higher and gradually decreased towards the edge regions. This difference of gray values gives trouble in segmentation and detection of inner holes in red ginseng image, so preprocessing technique is necessary. The preprocessing was done by subtracting source image from an empty background image. But, simple subtraction was not quite appropriate because of too small contrast between inner holes and sound part. Scaled subtraction images were obtained by multiplying all gray values by some numbers. However this method could not help to set threshold value because the gray values of root part are generally lower than body part when red ginseng is exposed to the x-ray. To determine threshold value for detecting inner holes, an algorithm was developed by increasing overall gray values of less clear images.

다양한 미속촬영 영상의 배경처리 기법 (Background Treatment Technique of Various Time-Lapse Images)

  • 김종성;김종찬;서영상;송승헌;김응곤
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2008년도 춘계 종합학술대회 논문집
    • /
    • pp.639-643
    • /
    • 2008
  • 시간의 흐름에 따른 계절의 변화, 꽃의 개화 등은 장시간에 걸쳐 이루어지므로 시간을 압축하여 빠르게 볼 수 있도록 미속촬영을 한다. 이러한 미속촬영을 이용하여 장소, 화각, 시간 등 다양한 조건을 동일한 상태에서 정확한 시간 간격을 통해 촬영하는 기법을 인터벌 촬영이라 한다. 미속촬영 기법은 교육, 과학, 다큐, 미디어 매체 등 다양한 분야에서 널리 사용한다. 본 논문에서는 미속촬영 영상을 취득함에 있어 기존과 다르게 꽃과 같은 주 피사체를 제외한 불필요한 배경을 삭제와 조정을 통해 영상처리가 가능하도록 하여 실사촬영 영상을 2D 및 3D상에서 필요한 라이브러리 또는 영상데이터로 폭 넓게 응용이 가능하도록 하여 누구나 쉽고 간편하게 영상제작에 창조성을 부여 할 수 있도록 하는 미속촬영 영상의 배경처리 기법을 제안한다.

  • PDF

Dual DCP 및 적응적 밝기 보정을 통한 단일 영상 기반 안개 제거 알고리즘 (Single Image Haze Removal Algorithm using Dual DCP and Adaptive Brightness Correction)

  • 김종호
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.31-37
    • /
    • 2018
  • 본 논문에서는 효과적이고 저 복잡도를 갖는 단일 영상 기반의 안개 제거를 위하여 dual dark channel prior (DCP)와 적응적인 밝기 보정 기법을 이용하는 알고리즘을 제안한다. 작은 크기의 패치에 의한 dark channel은 영상의 에지 정보를 잘 보존하지만 국부적인 잡음 및 밝기 변화에 민감한 반면, 큰 크기의 패치에 의한 dark channel은 정확한 안개 값을 추정하는데 유리하지만 블록 현상과 이로 인한 후광 효과는 안개 제거 성능을 떨어뜨린다. 이러한 문제를 해결하기 위하여 기존의 방법에서는 계산량 및 메모리 요구량이 큰 matting 기법을 활용한 반면, 제안하는 방법은 크기가 다른 패치로부터 구한 dark channel을 합성하여 dual DCP를 구성하고, 이를 이용하여 안개를 제거함으로써 적은 계산량 및 메모리 요구량을 달성한다. 또한 안개 성분을 제거한 영상에 적응적 밝기 보정 기법을 적용하여 영상에 포함된 객체가 선명하게 보존될 수 있도록 한다. 안개 성분이 포함된 다양한 영상에 대해 수행한 실험 결과 제안하는 안개 제거 기법이 기존의 방법에 비해 안개 제거 성능이 우수하면서 계산량과 메모리 요구량이 감소함을 알 수 있다.

가중 팔각형 메디안 필터를 이용한 영상 복원 (Image Restoration using Weighted Octagonal Median Filter)

  • 이은영;나철훈;이은경
    • 한국정보통신학회논문지
    • /
    • 제25권2호
    • /
    • pp.202-207
    • /
    • 2021
  • 영상 처리에서 중요한 연구 분야 중 하나는 잡음 제거이다. 영상의 잡음 제거는 비정상 시퀀스 및 다양한 유형의 잡음에 의한 손상과 같은 여러 이유로 인해 해결하기 어려운 문제이기 때문이다. 인간의 시각적 인식은 에지 정보에 크게 의존한다. 따라서 잡음 제거 시 반드시 에지 정보를 보존해야 한다. 노이즈를 제거하기 위해 일반적으로 정방형 메디안필터를 사용한다. 이 방법은 수학적 단순성을 가지고 있지만 에지 영역을 흐리게 한다는 단점이 있다. 본 논문에서는 영상 내에 존재하는 잡음을 효과적으로 제거하기 위해서 에지 검출 알고리즘을 갖는 가중 팔각형 메디안 필터를 사용한 새로운 메디안 필터 윈도우를 제안하였다. 이 방법은 에지를 검출하기 위해 움직이는 가중 팔각형 창을 사용하였다. 그리고 결과를 일반 메디안 필터, 격자형 메디안 필터 그리고 본 논문에서 제안한 가중 팔각형 메디안 필터의 결과와 비교하였다. 실험 결과, 에지 검출 알고리즘을 갖는 가중 팔각형 메디안 필터를 이용한 영상 복원이 일반 메디안 필터나 격자형 메디안 필터를 사용한 결과보다 좋은 성능을 가짐을 확인하였다.

Novel Secure Hybrid Image Steganography Technique Based on Pattern Matching

  • Hamza, Ali;Shehzad, Danish;Sarfraz, Muhammad Shahzad;Habib, Usman;Shafi, Numan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권3호
    • /
    • pp.1051-1077
    • /
    • 2021
  • The secure communication of information is a major concern over the internet. The information must be protected before transmitting over a communication channel to avoid security violations. In this paper, a new hybrid method called compressed encrypted data embedding (CEDE) is proposed. In CEDE, the secret information is first compressed with Lempel Ziv Welch (LZW) compression algorithm. Then, the compressed secret information is encrypted using the Advanced Encryption Standard (AES) symmetric block cipher. In the last step, the encrypted information is embedded into an image of size 512 × 512 pixels by using image steganography. In the steganographic technique, the compressed and encrypted secret data bits are divided into pairs of two bits and pixels of the cover image are also arranged in four pairs. The four pairs of secret data are compared with the respective four pairs of each cover pixel which leads to sixteen possibilities of matching in between secret data pairs and pairs of cover pixels. The least significant bits (LSBs) of current and imminent pixels are modified according to the matching case number. The proposed technique provides double-folded security and the results show that stego image carries a high capacity of secret data with adequate peak signal to noise ratio (PSNR) and lower mean square error (MSE) when compared with existing methods in the literature.