• Title/Summary/Keyword: Image rotation

Search Result 842, Processing Time 0.024 seconds

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

The Affects of Assessing Local Festivals on Visitor Satisfaction and Behavioral Intentionteristics of Local Festivals on Visitors' Intention to Revisit -Study Case on the Seoul Friendship Fair hosted by Seoul Metropolitan Government- (지역축제 평가속성이 방문객 만족도 및 행동의도에 미치는 영향 -서울특별시 지구촌 나눔 한마당 축제를 중심으로-)

  • Lee, Won-Hyoung;Jeon, In-Oh
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.310-321
    • /
    • 2016
  • This study aims to analyze the impact of elements for evaluating the festival, such as festival content, accessibility and convenience and festival image, on visitor satisfaction and behavioral intention, based on the actual case of Seoul Friendship Fair (SFF) which has been hosted by the City of Seoul every May since 1996. The SFF is participated by 64 embassies operating in Seoul and Seoul's 14 sister & friendship cities. Some 100,000 out of the total 350,000 visitors to the SFF are from overseas. The main elements of this study include survey responses about festival content and population statistics frequency analysis conducted over 277 festival visitors. As for factors, as a result of varimax rotation over main elements, technical statistics, credibility analysis and correlation analysis were done over each element group of five. Hypothesis was validated through regression analysis that the elements for evaluating local festivals have an impact on visitor satisfaction and behavioral intention. The suggestions and results of this study, both theoretical and practical, were presented to help the SFF differentiate itself and thereby become one of Seoul's most representative festivals.

A Real-time Hand Pose Recognition Method with Hidden Finger Prediction (은닉된 손가락 예측이 가능한 실시간 손 포즈 인식 방법)

  • Na, Min-Young;Choi, Jae-In;Kim, Tae-Young
    • Journal of Korea Game Society
    • /
    • v.12 no.5
    • /
    • pp.79-88
    • /
    • 2012
  • In this paper, we present a real-time hand pose recognition method to provide an intuitive user interface through hand poses or movements without a keyboard and a mouse. For this, the areas of right and left hands are segmented from the depth camera image, and noise removal is performed. Then, the rotation angle and the centroid point of each hand area are calculated. Subsequently, a circle is expanded at regular intervals from a centroid point of the hand to detect joint points and end points of the finger by obtaining the midway points of the hand boundary crossing. Lastly, the matching between the hand information calculated previously and the hand model of previous frame is performed, and the hand model is recognized to update the hand model for the next frame. This method enables users to predict the hidden fingers through the hand model information of the previous frame using temporal coherence in consecutive frames. As a result of the experiment on various hand poses with the hidden fingers using both hands, the accuracy showed over 95% and the performance indicated over 32 fps. The proposed method can be used as a contactless input interface in presentation, advertisement, education, and game applications.

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(4) - Velocity Profile(2) (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(4) - 유속분포(2))

  • Park, Chanjun;Sung, Jaeyong;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.2
    • /
    • pp.242-254
    • /
    • 2016
  • This paper is the forth investigation on the evaluation methods of flow characteristics in a steady flow bench. In the previous works, it was concluded that the assumption of the solid rotation might cause serious problems and both of the eccentricity and the velocity profile distort the flow characteristics when using the ISM at 1.75B plane. Also particle image velocimetry (PIV) measurement at this position showed that the real velocity profile was far from the assumption of ISM evaluation. In this paper, the planar velocity profiles were measure from 1.75B to 6.00B position by PIV and the characteristics were examined according to the valve angles and lifts for further investigations about the effect of the position on the velocity profile. The results show that $26^{\circ}$ valve angle is always an unique exceptional case in all aspects. If the valve angle is $21^{\circ}$ and below, the planar velocity profiles according to the lift and the position are similar to each other, however, the tangential velocity curves along with the radial direction have common tendencies up to $16^{\circ}$ angle. Also the well arranged swirl behaviors are generally observed at the position above 3.00B and the velocity contour lines come closer to the concentric circle as the valve lift increases. In addition, the gradient of tangential velocity along with the radial direction from the swirl center becomes stable and constant as the position goes downstream. Concurrently the velocity gradient is larger to the eccentric direction of the center. In the meantime the tangential velocity curves along with the radial direction are irregular and various at 1.75B, however, they become regular and reach higher level as the evaluation position goes downstream. At this time the curves of 4.50B are the best fitted to the ideal one. On the other hand in an exceptional case, $26^{\circ}$, the velocity contours are very complicated over 6mm valve lift regardless the position and the gradient increases to the opposite direction of the eccentric center. Also, 6.00B is a best fitting position in the geometrical cylinder center base. With respect to the swirl center, the distribution range of centers for 1.75B is different to that for the other positions and the eccentricities of this plane are larger regardless the valve angle. After 1.75B, there is no certain tendency in the center position change according to the valve angle and lift. Additionally, the eccentricities are not sufficiently small to neglecting the effect on ISM measurement.

Regional Projection Histogram Matching and Linear Regression based Video Stabilization for a Moving Vehicle (영역별 수직 투영 히스토그램 매칭 및 선형 회귀모델 기반의 차량 운행 영상의 안정화 기술 개발)

  • Heo, Yu-Jung;Choi, Min-Kook;Lee, Hyun-Gyu;Lee, Sang-Chul
    • Journal of Broadcast Engineering
    • /
    • v.19 no.6
    • /
    • pp.798-809
    • /
    • 2014
  • Video stabilization is performed to remove unexpected shaky and irregular motion from a video. It is often used as preprocessing for robust feature tracking and matching in video. Typical video stabilization algorithms are developed to compensate motion from surveillance video or outdoor recordings that are captured by a hand-help camera. However, since the vehicle video contains rapid change of motion and local features, typical video stabilization algorithms are hard to be applied as it is. In this paper, we propose a novel approach to compensate shaky and irregular motion in vehicle video using linear regression model and vertical projection histogram matching. Towards this goal, we perform vertical projection histogram matching at each sub region of an input frame, and then we generate linear regression model to extract vertical translation and rotation parameters with estimated regional vertical movement vector. Multiple binarization with sub-region analysis for generating the linear regression model is effective to typical recording environments where occur rapid change of motion and local features. We demonstrated the effectiveness of our approach on blackbox videos and showed that employing the linear regression model achieved robust estimation of motion parameters and generated stabilized video in full automatic manner.

A Comparison of the Difference in the Golf Swing Motion According to Somatotypes (체형에 따른 골프 스윙 동작 비교)

  • Chung, Nam-Ju;Yoon, Hee-Joong;Baik, Young-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.33-49
    • /
    • 2002
  • This study was intended to provide basic materials for golf coaching by somatotype by analyzing and comparing the kinematic factors found in each somatotype at the time of golf swing. For this purpose, the somatotype was divided into endomorph, mesomorph and ectomorph in reference to the weight, height and upper arm circumference of each of nine professional golfers. Each of their swing motions was videotaped with the camcorder and their swing motion was analyzed by dividing it into 8 sections. The time required for the swing motion, the displacement of the center of the human body and the rotation angle of the upper body were calculated through the three-dimensional image analysis based on the DLT(Direct Linear Transformation). Based on the findings of this study, the following conclusion was drawn: The endomorphic golfers showed the longest required golf swing time, followed by the mesomorphic golfer and then the endomorphic golfer. The displacement of left-to-right movement was largest in the mesomorphic golfers, followed by the endomorphic golfers the up-to-down displacement was upward at the time of impact and that the endomorphic and mesomorphic golfers raised the sense of stability by maintaining an almost uniform height at the time of impact. As for the rotational angle of the upper body and the rotational angle of the thigh, the upper body and the thigh took a form of rotating earlier in the ectomorphic golfers at the time of impact, who showed a somewhat different characteristics compared to the endomorphic and mesomorphic golfers. It is necessary to investigate the movement of more fundamental forces in presenting the theory related to the kinematic characteristics of this swing by somatotype. Accordingly, it is thought that it is necessary to analyze the center of pressure(COP) using the ground counterforce in the future study.

Stereo-based Robust Human Detection on Pose Variation Using Multiple Oriented 2D Elliptical Filters (방향성 2차원 타원형 필터를 이용한 스테레오 기반 포즈에 강인한 사람 검출)

  • Cho, Sang-Ho;Kim, Tae-Wan;Kim, Dae-Jin
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.10
    • /
    • pp.600-607
    • /
    • 2008
  • This paper proposes a robust human detection method irrespective of their pose variation using the multiple oriented 2D elliptical filters (MO2DEFs). The MO2DEFs can detect the humans regardless of their poses unlike existing object oriented scale adaptive filter (OOSAF). To overcome OOSAF's limitation, we introduce the MO2DEFs whose shapes look like the oriented ellipses. We perform human detection by applying four different 2D elliptical filters with specific orientations to the 2D spatial-depth histogram and then by taking the thresholds over the filtered histograms. In addition, we determine the human pose by using convolution results which are computed by using the MO2DEFs. We verify the human candidates by either detecting the face or matching head-shoulder shapes over the estimated rotation. The experimental results showed that the accuracy of pose angle estimation was about 88%, the human detection using the MO2DEFs outperformed that of using the OOSAF by $15{\sim}20%$ especially in case of the posed human.

Practical Considerations of Arterial Spin Labeling MRI for Measuring the Multi-slice Perfusion in the Human Brain (스핀 라벨링 자기공명영상을 이용한 사람 뇌에서의 뇌 관류영상의 현실적 문제점을 향상 시키는 방법 연구)

  • Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • In this work practical considerations of a pulsed arterial spin labeling MRI are presented to reliable multi-slice perfusion measurements In the human brain. Three parameters were considered in this study. First, In order to improve slice profile and Inversion efficiency of a labeling pulse a high power Inversion pulse of adiabatic hyperbolic secant was designed. A $900^{\circ}$ rotation of the flip angle was provided to make a good slice profile and excellent Inversion efficiency. Second, to minimize contributions of a residual magnetization be4ween Interleaved scans of control and labeling we tested three different conditions which were applied 1) only saturation pulses, 2) only spotter gradients, and 3) combinations of saturation pulses and spotter gradients Applications of bo4h saturation pulses and spoiler gradients minimized the residual magnetization. Finally, to find a minimum gap between a tagged plane and an imaging plane we tested signal changes of the subtracted image between control and labeled Images with varying the gap. The optimum gap was about 20mm. In conclusion, In order to obtain high quality of perfusion Images In human brain It Is Important to use optimum parameters. Before routinely using In clinical studios, we recommend to make optimizations of sequence parameters.

  • PDF

Arthroscopic Posterior Capsular Shaft for Traumatic Recurrent Unidirectional Posterior Subluxation of the Shoulder (외상으로 인한 재발성 단방향 견관절 후방 아탈구의 관절경을 이용한 후방낭 이동술)

  • Kim, Seung-Ho;Ha, Kwon-Ick;Yoo, Jae-Chul;Lee, Yong-Seuk;Lee, Hui-Dong
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.55-66
    • /
    • 2003
  • Background: The purpose of this study was to evaluated results of arthroscopic treatment of the traumatic recurrent unidirectional posterior subluxation. Materials and Methods: We treated twenty-seven patients who had traumatic recurrent unidirectional posterior subluxation of the shoulder by arthroscopic labral repair and posterior capsular shift and prospectively evaluated for a mean of thirty-nine months (range,24 to 85 months). Patients who had posteroinferior instability, multidirectional instability, atraumatic onset, or revision cases were excluded. There were twenty-five male and two female patients with the mean age of twenty-one years (range, 14 to 33 years). All patients were involved in sports activity. All had a significant traumatic event prior to the onset of the instability. Stability, motion, three objective measurement (UCLA, ASES, and Rowe scores) and two subjective measurements (pain and function visual analogue scale) were evaluated. Results: The most common finding in magnetic resonance image-arthrogram was separation of the posteroinferior labrum without displacement in 9 patients, In arthroscopic examination, all patients had one or more lesions in the posterior inferior labrum and capsule. The most common finding was incomplete stripping of the posterior inferior labrum (18 patients). The posteroinferior capsule subjectively appeared to be stretched in twenty-two patients. At follow-up, all patients had improved shoulder function and scores(p < 0.01). All patients had stable shoulder by subjectivel and objectivel measurements, except one patient who had recurrent subluxation. All but one patient with postoperative recurrence were able to return to their prior sports activity with little or no limitation. Twenty-four patients were graded as having more than 90% of shoulder function. Their were twenty-one excellent, five good, and one fair UCLA. scores. Pain sore improved from 4.5 to 0.2 point(p : 0.0001). Mean loss internal rotation was one vertebral level. None had operative complications. Conclusion: In conclusion, treatment outcomes of the traumatic unidirectional recurrent posterior subluxation are consistently reliable with respect to the stability, pain relief, and functional restoration by the arthroscopic posterior capsular shift procedure.

Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

  • Kim, Dae Gun;Jung, James J;Cho, Kwang Hwan;Ryu, Mi Ryeong;Moon, Seong Kwon;Bae, Sun Hyun;Ahn, Jae Ouk;Jung, Jae Hong
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.250-257
    • /
    • 2016
  • The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy. Thirty six-patients previously treated with IMRT technique were selected, and divided into two groups based on applied immobilization devices (FF versus LF). We performed a retrospective clinical analysis including the mean, systematic, random variation, 3D-error, and calculated the planning target volume (PTV) margin. In addition, a rotational error (angles, $^{\circ}$) for each patient was analyzed using the automatic image registration. The 3D-errors for the FF and the LF groups were 3.70 mm and 4.26 mm, respectively; the LF group value was 15.1% higher than in the FF group. The treatment margin in the ML, SI, and AP directions were 5.23 mm (6.08 mm), 4.64 mm (6.29 mm), 5.83 mm (8.69 mm) in the FF group (and the LF group), respectively, that the FF group was lower than in the LF group. The percentage in treatment fractions for the FF group (ant the LF group) in greater than 5 mm at ML, SI, and AP direction was 1.7% (3.6%), 3.3% (10.7%), and 5.0% (16.1%), respectively. Two different immobilization devices were affected the patient setup errors due to different fixed location in low extremity. The radiotherapy for the pelvic region by Tomotherapy should be considering variation for the rotational angles including Yaw and Pitch direction that incorrect setup error during the treatment. In addition the choice of an appropriate immobilization device is important because an unalterable rotation angle affects the setup error.