• 제목/요약/키워드: Image quality measurement

검색결과 427건 처리시간 0.031초

계란의 신선도 결정과 영상분석을 이용한 내부품질 측정 (Determination of Egg Freshness and Internal Quality Measurement Using Image Analysis)

  • 김현태;고한종;김기연;가등굉랑;희다유자;서진귀구
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.166-172
    • /
    • 2007
  • Egg quality indices are related with freshness, size of air chamber, loss of weight, and viscosity of the yolk and the protein. However, since the described quality parameters require measured in a destructive way, it is not suitable to inspect the egg quality with complete enumeration. Therefore, this study was performed to investigate the potential of image analysis method for evaluation of internal egg quality. Samples of 90 fresh eggs were collected immediately after laying and stored up to 24 days. Five eggs were randomly drawn from each storage condition (packing vs unpacking) at a regular interval and loss of weight, specific gravity and size of air chamber were measured. The image analysis for nondestructive measurement of size of air chamber was also studied. Results showed that the egg weight and gravity gradually decreased with increasing of storage days, while the size of air chamber linear increased caused by evaporation of water through the shell. A relationship a between conventional method and the image analysis method for measuring the size of air chamber was developed with the correlation coefficient of 0.928. The new finding implied that image analysis might provide a useful nondestructive tool to assess internal egg quality.

Evaluation of SAR Image Quality

  • Lee Young-ran;Kim Kwang Young;Kwak Sunghee;Shin Dongseok;Jeong Soo;Kim Kyung-Ok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.397-400
    • /
    • 2004
  • Synthetic Aperture Radar(SAR) is an active micro­wave instrument that performs high-resolution observation under almost all weather conditions. Although there are many advantages of SAR instrument, many complicated steps are involved in order to generate SAR image products. Many research and algorithms have been proposed to process radar signal and to increase the quality of SAR products. However, it is hard to find research which compare the quality of SAR products generated with different algorithms and processing methods. In our previous research, a SAR processing s/w was developed for a ground station. In addition, quality assessment procedures and their test parameters inside a SAR processor was proposed. The purpose of this paper is to evaluate the quality of SAR images generated from the developed SAR processing s/w. However, If there are no direct measurements such as radar reflector or scattering field measurement values it is difficult to compare SAR images generated with different methods. An alternative procedures and parameters for SAR image quality evaluation are presented and the problems involved in the comparison methods are discussed. Experiments based on real data have been conducted to evaluate and analyze quality of SAR images.

  • PDF

레이저광 반사 화상을 이용한 표면 거칠기 측정법의 개발과 적용 (Development of a Surface Roughness Measurement Method Using Reflected Laser Beam Image and Its Application)

  • ;김화영;안중환;최이존
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.51-57
    • /
    • 2001
  • A light beam reflected from a machined surface generally containes information concerning about its surface roughness. This study examines and proposes a surface roughness measurement technique for on-machine measurement of machined surfaces. The technique is based on the measurement of a reflected laser beam pattern and the statistical analysis of its light intensity distribution. The surface roughness was found to be closely related to the standard deviation of the light intensity on the primary axis of the reflected pattern. An image acquisition device is made up of a laser diode, a half mirror, a screen, and a CCD camera. The exact image with the primary and secondary axes of a reflected laser beam pattern is calculated through such image processing algorithm as thresholding, edge detection, image rotation, segmentation, etc. A median filter and a surrounding light correction algorithm are improve the image quality and reduce the measuring error. Using the developed measuring device the effect of screen materials and workpiece and workpiece materials was investigated. Experimental results regarding to relatively high-quality surfaces machined by grinding, polishing, lapping processes have shown the measurement error is within 10% in the range of $0.1{mu}m~0.8{\mu}m R_q.$Therefore, the proposed method is thought to be effectively used when quick measurements is needed with workpieces fixed on the machine.

  • PDF

Study on Image Retention in an AC Plasma Display Panel

  • Kim, Sang-Ho;Choi, Kyung-Cheol;Shin, Bhum-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.259-262
    • /
    • 2005
  • Image retention is a kind of fatal shortcoming of the AC PDPs for realizing high-quality picture. In this work, the measurement method of image retention was proposed using temporal measurement of luminance, CIEXYZ tristimulus values, IR emission of reset pulse, and temperaturel. On the base of temporal measurement of luminance, CIEXYZ tristimulus value, and IR emission of reset pulse, the retention time of Ne+5%Xe gas-mixture discharge was about 2 hours after white window image. However, it was about 20 minute on the base of temporal measurement of temperature.

  • PDF

고속영상처리에 의한 레일형상측정시스템 개발 (Development of Rail Profile Measurement System using High Speed Laser Image Processing)

  • 문철이;김만철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1320-1325
    • /
    • 2006
  • Railway track supports and guides train and it directly affects ride quality and safety. To maintain track quality, regular maintenance activity is essential but it degrades track usage since maintenance activity occupies the track during the work. To achieve maximum track efficiency, track inspection should be performed at commercial running speed. In this paper, we designed and developed high speed rail profile measurement system using laser light sectioning method with line laser generator, digital camera and DSP based image processing system. The measurement system can supports rail profile measurement at the speed of 300 Km/h that can be applied to KTX.

  • PDF

디지털 상관기 성능 측정의 최적화 기법 (Optimization Methodology of Quality Measurement of Digital Correlator)

  • 염재환;정구영;노덕규;오세진;김광동;이창훈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.371-372
    • /
    • 2006
  • In this paper, we propose a method that measures quality of digital correlator. Quality of digital correlator in field of image composition of radio astronomy have as important position for acquisition of radio wave image with high precision. Digital correlator should have wide bandwidth and high precision to study on deep space. Digital correlator, therefore, should be designed to have high speed processing and high precision. But, real time measurement of quality of digital correlator using acquisition data is difficult to compare accuracy of result because digital correlator should process a large quantity of data with high speed. Measurement method of quality, also, has intricate implementation of experiment equipment. this paper present methods that compose experiment equipment without external installation easily and verify quality of digital correlator perfectly.

  • PDF

시각센서를 이용한 축대칭 물체 측정 시스템 개발 (Development of a Measurement System for Axial-symmetric Objects Using Vision Sensor)

  • Lee, S.R.;Kim, C.S.
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.34-41
    • /
    • 1997
  • The dimension measurement problem of products has been a major concern in the quality control in the industrial fields. A non-contacting measurement system using the vision sensor is proposed in this paper. The system consists of a CCD camera for the image capture, a frame grabber for the acquired image processing, a laser unit for the illumination, scanning unit for the measurement, and a personal computer for the geometry computation. The slit beam which is generated by passing the laser beam through a cylin- drical lens is fired to the axial-symmetric object on the rotating plate. The image of objects reflected by the laser slit beam, acquired by the CCD camera, becomes much brighter than the other parts of objects. After the histogram of brightness for the captured image is calculated, low intensity pixels are filtered out by threshold method. The performance of proposed measurement system is obtained for several different axial symmetric objects. The proposed system is verified as a good tool for measuring axial-symmetric parts in a limited condition with a minor investment cost.

  • PDF

객관적 화질 평가와 주관적 화질 평가의 상관관계 연구 (Correlation Research between Objective and Subjective Image Quality Assessment)

  • 박형주;하동환
    • 한국콘텐츠학회논문지
    • /
    • 제11권8호
    • /
    • pp.68-76
    • /
    • 2011
  • 최근 소비자의 화질에 대한 높은 관심으로 관련 시장 경쟁력이 가열되었으며, 이에 따라 제조사는 고객만족을 위한 제품을 개발하는 방향으로 진보하고 있다. 그러나 제품의 객관적 성능 향상이 실제 소비자가 인지하는 화질의 선호도에 항상 긍정적인 영향을 미친다고 단정하기 어렵다. 또한 선행연구를 통해 객관적 성능 평가 방법과 주관적 화질 평가 결과 간의 상관관계를 찾기 어려웠다. 그러므로 객관적 화질 재현 성능이 이미지 선호도에 미치는 영향을 파악하여 감상자가 선호하는 화질에 대해 분석할 필요가 있다. 따라서 본 논문에서는 객관적 화질 평가 요소들을 측정하고 이러한 수치들이 이미지 선호도와 어떠한 관계를 갖고 있는지 분석하고자 하였다. 이와 같은 연구를 위해 ISO에서 규정하고 있는 화질 평가 방법을 사용하여 이미지의 선호도를 측정하였으며 이러한 결과가 객관적 화질 평가 요소들과 어떠한 상관관계를 갖고 있는지 통계적으로 분석하였다. 이와 같은 결과는 화질을 향상시키는 요소를 분석할 수 있으며 단순한 고화질 추구를 위한 성능 개발뿐만 아니라 감상자가 선호하는 화질을 파악하여 개발에 도움이 될 수 있는 실질적인 연구로 기대된다.

Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine

  • Cho, Young-kwon;Lee, Youngjin;Lee, Kichang
    • 한국임상수의학회지
    • /
    • 제39권3호
    • /
    • pp.114-120
    • /
    • 2022
  • The purpose of this study is to examine the status of quality control using multipurpose phantom of ultrasound equipment used in hospital of veterinary college in South Korea by using ATS-539 multipurpose phantom so as to examine quantitative and objective new image evaluation method. Specialists discussed and analyzed multipurpose phantom images acquired by using convex transducer of 10 ultrasound imaging devices, currently used in 9 veterinary colleges, at 4.0-6.0 MHz. Total 8 items that can be measured with ATS-539 multipurpose phantom including dead zone, vertical and horizontal measurement, axial/lateral resolution, sensitivity, focal zone, functional resolution and gray scale/dynamic range were evaluated. For qualitative evaluation, valid decisions were made based on dead zone, axial/lateral resolution, and gray scale/dynamic range which are resolution index, and coefficient of variation (COV) and blind referenceless image spatial quality evaluator (BRISQUE) were found to increase objectivity. As a result of experiment, all the targeted ultrasonic devices were found appropriate from qualitative evaluation items of dead zone, axial/lateral resolution, and gray scale/dynamic range. In other evaluation items, they were found to be appropriate from focal zone and vertical measurement of quantitative evaluation while inappropriate from horizontal measurement, sensitivity, and functional resolution. COV value was 0.12 ± 0.04, and BRISQUE value was 47.77 ± 2.77, both analysis results show that the noise level of all ultrasonic devices was located within tolerance range. Upon image examination using ATS-539 multipurpose phantom, they were 100% appropriate with inspection standards of dead zone, axial/lateral resolution, and gray scale/dynamic range, and besides, focal zone and functional resolution can be used as evaluation items. In the field of veterinary medicine, 8 standard items using ATS-539 multipurpose phantom and image evaluation items using COV and BRISQUE can be used as standards for quality control of ultrasonography machine.

An Image Quality Evaluation Model for Optical Strip Signal-to-Noise Ratio in the Target Area of High Temperature Forgings

  • Ma, Hongtao;Zhao, Yuyang;Feng, Yiran;Lee, Eung-Joo;Tao, Xueheng
    • Journal of Multimedia Information System
    • /
    • 제8권2호
    • /
    • pp.93-100
    • /
    • 2021
  • Under the time-varying temperature, the high-temperature radiation of forgings and the change of reflection characteristics of oxide skin on the surface of forgings lead to the difficulty of obtaining images to truly reflect the geometric characteristics of forgings. It is urgent to study the clear and reliable acquisition method of hot forging feature image under time-varying temperature to meet the requirements of visual measurement of hot geometric parameters of forgings. Based on this, this chapter first puts forward the quality evaluation method of forging feature image, which provides guarantee for the accurate evaluation of feature image quality. Furthermore, the factors that affect the image quality, such as the radiation characteristics of forgings and the photographic characteristics of cameras, are analyzed, and the imaging spectrum which can effectively suppress the radiation intensity of forgings is determined. Finally, aiming at the problem that the quality of image acquisition is difficult to guarantee due to the drastic change of radiation intensity of forgings under time-varying temperature, an image acquisition method based on minimum signal-to-noise ratio (SNR) based laser light intensity adaptation is proposed, which significantly improves the definition of feature light strips in forging images at high temperature, and finally realizes the clear acquisition of feature images of large-scale hot forging under time-varying temperature.