• Title/Summary/Keyword: Image magnification

Search Result 190, Processing Time 0.024 seconds

Image Magnification Using Median Filter and Spatial Variation (메디안 필터와 공간 변화량을 이용한 영상 확대)

  • Kwak, Nae-Joung
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.9
    • /
    • pp.72-80
    • /
    • 2007
  • Image magnification is the estimation of a few pixel in images with high quality from a pixel of an image with low resolution and there have been studied many techniques to make images with high quality. In this paper, we propose an image interpolation method using median filter and spatial information. The proposed method makes an interpolating pixel using an average value of a median filtered value and an average value of two pixels correlated with an interpolating pixel tightly. Also we make the magnified image with improved quality to add the directional information of surrounding pixels and the characteristic of ones using average value and max value of spatial variation. We evaluate the performance using PSNR in the quality of enlarged image comparing the proposed method with existing methods. The results show the proposed method improves PSNR than the existing methods and make images preserving the characteristic of original imges.

A STUDY ON THE HORIZONTAL IMAGE MAGNIFICATION OF ORTHOPANTOMOGRAPHY (Orthopantomograph에 있어서 상의 수평확대에 관한 연구)

  • Kim Han Pyoung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.4 no.1
    • /
    • pp.39-44
    • /
    • 1974
  • The purpose of this study is to obtain the horizontal magnification rate of orthopantomography. The subjects were consisted of 30 Korean adults who had Angle's classification I occlusion by using measuring wire set On the incisal edges of anterior teeth and the occlusal surfaces of premolars and molars along the dental arch. The results are as follows; 1. The average rate of total magnification was 115%. 2. The average rates of local magnification were the anterior teeth region was 90%, the canine region was 96%, the premolar region was 104%, the 1st molar region was 117% and the 2nd molar region was 124%.

  • PDF

Application of Curve Interpolation Algorithm in CAD/CAM to Remove the Blurring of Magnified Image

  • Lee Yong-Joong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.115-124
    • /
    • 2005
  • This paper analyzes the problems that occurred in the magnification process for a fine input image and investigates a method to improve the problems. This paper applies a curve interpolation algorithm in CAD/CAM for the same test images with the existing image algorithm in order to improve the problems. As a result. the nearest neighbor interpolation. which is the most frequently applied algorithm for the existing image interpolation algorithm. shows that the identification of a magnified image is not possible. Therefore. this study examines an interpolation of gray-level data by applying a low-pass spatial filter and verifies that a bilinear interpolation presents a lack of property that accentuates the boundary of the image where the image is largely changed. The periodic B-spline interpolation algorithm used for curve interpolation in CAD/CAM can remove the blurring but shows a problem of obscuration, and the Ferguson's curve interpolation algorithm shows a more sharpened image than that of the periodic B-spline algorithm. For the future study, hereafter. this study will develop an interpolation algorithm that has an excel lent improvement for the boundary of the image and continuous and flexible property by using the NURBS. Ferguson's complex surface. and Bezier surface used in CAD/CAM engineering based on. the results of this study.

  • PDF

Autofocusing Mechanism of a Triple-Magnification Infrared System (3중 배율 적외선 영상 장비의 자동 초점 조절 방안)

  • Jung, Hyojung;Jeong, Suseong;Yang, Yunseok;Lee, Yongchun;Han, Jeongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.314-320
    • /
    • 2020
  • The optics used in an infrared imaging system has a strong refractive-index change according to temperature, so an autofocus control function is essential for a military infrared imaging system with a wide operating-temperature range. In this study, we design a triple-magnification infrared imaging system, and to compensate for the change in refractive index according to temperature we measure the change in the lens focus according to temperature. The autofocus control function was implemented by using the measured movement amount, and we could obtain an image with satisfactory resolution performance over a wide range of operating temperatures.

The Effect of the Position Change of the Magnification Marker and the Stitching Range on the Image in the Examination of the Femur Radiography Using Stitching Technique (스티칭 기법을 이용한 대퇴골 방사선검사 시 확대 표식자 위치 및 스티칭 범위 변화가 영상에 미치는 영향)

  • Hong, Seong-Woo;Joo, Young-Cheol;Kim, Sheung-Hyuk;Go, Ye-Weon;Kim, Jong-Suk
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.331-336
    • /
    • 2020
  • In this study, we would like to examine the effect of the location of the magnification marker and the change in the stitching range on the magnification marker and the expansion of the anatomical structure in the examination of femoral stitching radiation using the stitching technique, and to find out the usability of the femoral stitching radiation examination in the preoperative examination for THRA. The measured values measured by 5 researchers were summed and presented through descriptive statistics. When the position of the magnification marker was changed, the average value of the measured value was in the range of 113.54 to 113.90 mm. The anatomical structures of the femur were measured in the range of 57.24 to 57.78 mm, 27.20 to 27.56 mm, and 70.11 to 70.81 mm, respectively. This showed a similar deviation from the expansion rate of previous related papers using markers. Therefore, it is considered that femoral stitching X-ray examination using magnification markers can be used for preoperative examination for THRA.

AN EXPERIMENTAL EXAMINATION OF MULTIMODAL IMAGING SYSTEM FOR IMPLANT SITE ASSESSMENT (인공치아 이식부위 분석을 위한 다기능 영상체계의 실험적 검사)

  • Park Chang-Seo;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 1998
  • The Scanora/sup (R)/ X-ray unit uses the principles of narrow beam radiography and spiral tomography. Starting with a panoramic overview as a scout image. multiple tomographic projections could be selected. This study evaluated the accuracy of spiral tomography in comparison to routine panoramic radiography for dental implant treatment planning. An experimental study was performed on a cadaver mandible to assess the accuracy of panoramic radiography and spiral tomography film images for measurement of metallic spheres. After radiographic images of the metallic spheres on the surgical stent were measured and corrected for a fixed magnification of radiographic images. following results were obtained. 1. In the optimal position of the mandible. the minimal horizontal and vertical distortion was evident in the panoramic radiography images. The mean horizontal and vertical magnification error in anterior sites was 5.25% and 0.75%. respectively. The mean horizontal and vertical magnification error in posterior sites was 0.50% and 1.50%. respectively. 2. In the displaced forward or in an eccentric position of the mandible. the magnification error of the panoramic radiography images increased significantly over the optimal position. Overall, the mean horizontal magnification error of the anterior site in the different positions changed dramatically within a range of -17.25% to 39.00%, compared to the posterior range of -5.25% to 8.50%. However, the mean vertical magnification error stayed with the range of 0.5% to 3.75% for all the mandibular positions. 3. The magnification effects in the tomographic scans were nearly identical for the anterior and posterior with a range of 2.00% to 5.75% in the horizontal and 4.50% to 5.50% in the vertical dimension, respectively. 4. A statistically significant difference between the anterior and posterior measurements was found in the horizontal measurements of the panoramic radiography images of the displaced forward and backward position of the mandible(P<0.05). Also a significant difference between the optimal panoramic and tomographic projections was found only in the vertical measurement(P<0.05).

  • PDF

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detector

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2567-2571
    • /
    • 2023
  • Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To evaluate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

A Study on Image Magnification Scheme using the Surface Characteristics in Image (영상의 곡면 특성을 이용한 영상 확대 기법에 관한 연구)

  • Jung, Soo-Mok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.473-474
    • /
    • 2014
  • 본 논문에서는 자연 영상에 존재하는 영상의 곡면 특성을 효과적으로 이용하여 영상을 확대하는 기법을 제안하였다. 제안된 기법이 기존의 기법에 비하여 성능이 향상되었음을 실험을 통하여 확인하였다.

  • PDF

APLICATION OF FRACTAL DIMENSION ESTIMATION ALGORITMS TO EVALUATING HUMAN SKIN STATE

  • Araghy, Ali Parchamy;Sato, Mie;Kasuga, Masao
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.655-658
    • /
    • 2009
  • Fractal dimension has been used for texture analysis as it is highly correlated with human perception of surface roughness and applied to quantifying the structures of wide range of objects in biology and medicine. On the other hand, the evaluation of the human skin state is based solely on the subjective assessment of clinicians; this assessment may vary from moment to moment and from rater to rater. Therefore we attempt to analysis of skin texture image using fractal dimension and discuss its application to evaluating human skin state. It can be helpful for extracting human features and also can be useful for detection of many human skin diseases. This paper presents a method to calculate fractal dimension of skin with use of camera lens magnification. We take multiple pictures frequently from skin with different camera lens magnification as a magnification factor of fractal set, and counting the number of objects (cells) in each picture as a number of self similar pieces of fractal set.

  • PDF