• Title/Summary/Keyword: Image guidance

Search Result 236, Processing Time 0.024 seconds

Conceptions Toward Career Development and Occupational View between Giftedness in Computer Science and Normal Students in Elementary School (초등정보과학영재와 일반학생의 진로발달 및 직업관 인식에 대한 조사 연구)

  • Lee, Jaeho;Choi, Seung Hee
    • Journal of Gifted/Talented Education
    • /
    • v.24 no.4
    • /
    • pp.613-628
    • /
    • 2014
  • The purpose of this study is to compare the differences of the career development and the occupational view between giftedness in computer science and normal students in elementary school, so the results of this study provide assistance to the teacher for the direction and guidance on the career education of the giftedness in computer science in elementary school. This survey is based on 82 giftedness in computer science and 167 normal elementary school students. The questionnaires used in the study contain questions asking regarding the career development and the occupational view. The results of this study were as follows : First, according to the consciousness analysis result about career, the giftedness in computer science choose to be scientific technicians, the normal students choose to be artists. The both groups get career information from their parents, but they usually don't get career counseling from teachers. The education of giftedness in computer science does not contribute to changing their dreams, while normal students have no interest in computer science. Second, according to the career development analysis result, in comparison with non-gifted students, the gifted in information science had more success in all domains of career development. Third, according to the occupational view analysis result, the information science gifted students had higher meaningful rate than the normal students. Intrinsic domain' had higher meaningful rate among the subordinate domains, there is no difference in 'extrinsic domain' and 'incidental domain' between the information science gifted students and the normal students. Fourth, according to the correlation analysis result of the career development and the occupational view, there is a positive correlation in all domains of them. The high they are in the career development, the more they have the certain occupational view. Likewise, if they have the certain occupational view, they will be more successful in career development. Based on the findings of this research, the directing and guidance on the career education of giftedness in computer science in elementary school is same as the followings. We should educate parents regarding information about career for students who are under the influence of parents greatly and indicate them to apply to their children appropriately. In addition, for making them to have the positive image of the computer science, teacher should provide more information about the area of information and form various curriculums to induce more interests about computer science. We need to strengthen the career education for guiding the gifted to assist them to establish their own goal and realize them how to study and choose their career in the future. In school education field, it must develop and manage the definite and empirical program, not the career development program which is focused on only entrance into advanced school, to boost self-realization ability and the suitable career education program based on the correct understanding on giftedness in computer science. For this, through steady trying and research, teachers should be eater to develop the career education for students. Also, we have to implement the internal stability career education program, so it will help students to be aware of their job and career; therefore, students will be able to plan and prepare for their career in this rapid changing world.

Comparison of the Results of Ultrasound-guided Caudal Epidural Block - Herniated Intervertebral Disc vs Spinal Stenosis - (초음파를 이용한 미추 경막외 차단술의 결과 비교 - 추간판 탈출증과 척추관 협착증 -)

  • Kim, Young-Tae;Cho, Kyu-Jung;Ahn, Chi-Hoon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.105-112
    • /
    • 2014
  • Purpose: Ultrasound-guided epidural caudal block for low back pain and radiating pain is often performed in the treatment of outpatients. However, this procedure has a failure rate of up to 25% even when it performed by an experienced physician. The authors investigate the effectiveness of Ultrasound-guided epidural caudal block in patients related to disc herniation or spinal stenosis. Materials and Methods: Ultrasound-guided caudal epidural block was performed in 55 outpatients with LBP and radiating pain. Patient was placed in the prone position and sonographic image of sacral hiatus was obtained using linear probe. A 22-gauge needle was advanced into the sacrococcygeal membrane under ultrasound guidance and then medication was injected into the caudal epidural space. There were 31 cases of disc herniation, and 24 cases of spinal stenosis. Patients were evaluated by Visual Analog Scale (VAS) pain score at pre-treatment, post-treatment, 2 weeks and 4 weeks by telephone interviews. Results: 53 of the 55 cases (96.4%) of needle insertion into the sacral canal under ultrasound guidance were successful. Gender was not significantly different between disc herniation group and spinal stenosis group. But there was a significant age difference between disc herniation group ($42.3{\pm}10.8$), and spinal stenosis group ($62.8{\pm}15.1$) [p<0.001]. The VAS score at pre-treatment, post-treatment, 2 weeks, 4 weeks in disc group were 6.84, 3.1, 1.8 & 1.77. The VAS score at pre-treatment, post-treatment, 2 weeks, 4 weeks in spinal stenosis group were 6.88, 3.58, 4.33 & 4.88. The VAS score in both groups was significantly improved after the procedure (p<0.001). Over time, the two groups were statistically significant differences in VAS score after adjusting for age (p<0.001). Conclusion: Ultrasound-guided caudal epidural block seems to provide a high success rate and a significantly better response in disc group than spinal stenosis group.

  • PDF

High-intensity focused ultrasound beam path visualization using ultrasound imaging (초음파 영상을 이용한 고강도 집중 초음파 빔 시각화)

  • Song, Jae Hee;Chang, Jin Ho;Yoo, Yang Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-23
    • /
    • 2020
  • In High-Intensity Focused Ultrasound (HIFU) treatment, effective localization of HIFU focus is important for developing a safe treatment plan. While Magnetic Resonance Imaging guided HIFU (MRIgHIFU) can visualize the ultrasound path during the treatment for localizing HIFU focus, it is challenging in ultrasound imaging guided HIFU (USIgHIFU). In the present study, a real-time ultrasound beam visualization technique capable of localizing HIFU focus is presented for USIgHIFU. In the proposed method, a short pulse, with the same center frequency of an imaging ultrasound transducer below the regulated acoustic intensity (i.e., Ispta < 720 mW/㎠), was transmitted through a HIFU transducer whereupon backscattered signals were received by the imaging transducer. To visualize the HIFU beam path, the backscattered signals underwent dynamic receive focusing and subsequent echo processing. From in vitro experiments with bovine serum albumin gel phantoms, the HIFU beam path was clearly depicted with low acoustic intensity (i.e., Ispta of 94.8 mW/㎠) and the HIFU focus was successfully localized before any damages were produced. This result indicates that the proposed ultrasound beam path visualization method can be used for localizing the HIFU focus in real time while minimizing unwanted tissue damage in USIgHIFU treatment.

Ultrasound-guided Core Needle Biopsy in Diagnosis of Soft Tissue Masses (연부조직 종물의 진단에서 초음파 유도하 중심부 침생검)

  • Kim, Jeung-Il;Youn, Myung-Soo;Cheon, Sang-Jin;Choi, Gyung-Un;Lee, Tae-Hong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.113-119
    • /
    • 2004
  • Purpose: To determine the utility of sonographically guided percutaneous core needle biopsy to diagnose musculoskeletal soft tissue masses. Methods: A prospective study was performed in 55 patients referred for image-guided needle biopsy of primary or recurrent soft tissue masses and bone lesion or suspected solitary metastasis with extraosseous masses. Tissue samples were obtained with a 14-gauge or 18-gauge cutting needle coupled to an automated biopsy device under local anesthesia and sonographic guidance. Statistical analysis was based on 49 biopsies confirmed by successful clinical treatment (11 cases) or surgical resection (38 cases). Results: An accurate diagnosis was obtained in 47 (97%) of 49 biopsies; sensitivity was 95%, and specificity was 100%. The method did not yield sufficient tissue to establish a diagnosis in 6 cases. Considering all 55 biopsies, high-quality specimens were obtained in 87%. There were no serious complications. Conclusions: Sonographically guided core needle biopsy is accurate and safe, in soft tissue masses and bone tumors with extraosseous masses in the appendicular skeleton. In such patients, the sonographically guided procedure is the most prompt and effective method for obtaining tissue samples.

  • PDF

A study on uncertainty by passage of time of stereotactic body radiation therapy for spine metastasis cancer (척추 전이암 환자의 정위적방사선치료 시 시간 경과에 따른 불확실성에 관한 연구)

  • Cho, Yong Wan;Kim, Joo Ho;Ahn, Seung Kwon;Lee, Sang Kyoo;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.79-86
    • /
    • 2015
  • Purpose : The purpose of this study was to determine the proper treatment time of stereotactic body radiation therapy for spine metastasis cancer by using the image guidance system of CyberKnife(Accuray Incorporated, USA) which is able to correct movements of patients during the treatment. Materials and Methods : Fifty seven spine metastasis cancer patients who have stereotactic body radiation therapy of CyberKnife participate, 8 of them with cervical spine cancer, 26 of them with thoracic spine cancer, and 23 of them with lumbar spine cancer. X-ray images acquired during the treatment were classified by treatment site. From the starting point of treatment, motion tendency of patients is analyzed in each section which is divided into every 5 minutes. Results : In case of cervical spine, there is sudden increase of variation in 15 minutes after the treatment starts in rotational direction. In case of thoracic spine, there is no significantly variable section. However, variation increases gradually with the passage of time so that it is assumed that noticeable value comes up in approximately 40 minutes. In case of lumbar spine, sharp increase of variation is seen in 20 minutes in translational and rotational direction. Conclusion : Without having corrections during the treatment, proper treatment time is considered as less than 15 minutes for cervical spine, 40 minutes for thoracic spine, and 20 minutes for lumbar spine. If treatment time is longer than these duration, additional patient alignments are required or PTV margin should be enlarged.

  • PDF

Whole pelvic intensity-modulated radiotherapy for high-risk prostate cancer: a preliminary report

  • Joo, Ji Hyeon;Kim, Yeon Joo;Kim, Young Seok;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Su Ssan;Park, Jin-Hong;Jeong, Yuri;Ahn, Hanjong;Kim, Choung-Soo;Lee, Jae-Lyun;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.199-205
    • /
    • 2013
  • Purpose: To assess the clinical efficacy and toxicity of whole pelvic intensity-modulated radiotherapy (WP-IMRT) for high-risk prostate cancer. Materials and Methods: Patients with high-risk prostate cancer treated between 2008 and 2013 were reviewed. The study included patients who had undergone WP-IMRT with image guidance using electronic portal imaging devices and/or cone-beam computed tomography. The endorectal balloon was used in 93% of patients. Patients received either 46 Gy to the whole pelvis plus a boost of up to 76 Gy to the prostate in 2 Gy daily fractions, or 44 Gy to the whole pelvis plus a boost of up to 72.6 Gy to the prostate in 2.2 Gy fractions. Results: The study cohort included 70 patients, of whom 55 (78%) had a Gleason score of 8 to 10 and 50 (71%) had a prostate-specific antigen level > 20 ng/mL. The androgen deprivation therapy was combined in 62 patients. The biochemical failure-free survival rate was 86.7% at 2 years. Acute any grade gastrointestinal (GI) and genitourinary (GU) toxicity rates were 47% and 73%, respectively. The actuarial rate of late grade 2 or worse toxicity at 2 years was 12.9% for GI, and 5.7% for GU with no late grade 4 toxicity. Conclusion: WP-IMRT was well tolerated with no severe acute or late toxicities, resulting in at least similar biochemical control to that of the historic control group with a small field. The long-term efficacy and toxicity will be assessed in the future, and a prospective randomized trial is needed to verify these findings.

An Economic Feasibility Study of AR CDM project in North Korea (북한 지역을 대상으로 한 조림 CDM 사업의 경제적 타당성 연구)

  • Han, Ki Joo;Youn, Yeo-Chang
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.3
    • /
    • pp.235-244
    • /
    • 2007
  • Potentials of AR CDM project in North Korea are assessed and feasible land area for AR CDM project is estimated. According to our estimation, There could be 515,000 hectares of forest lands deforested before 1990 in North Korea and 8,854 hectares at the regional level of Gae-sung City, which are eligible for AR CDM project, based on researches of satellite image analyses conducted from 1980's to 1990's. A baseline scenario assumed 44.73 tones of carbon stored in soil per hectare with no vegetation above ground remained during the project period following the default value of IPCC's Good Practice Guidance for LULUCF considering soil structure, climate and land use of the project area. The scenario also assumes that black rocust (Robinia pseudoacacia) is planted and the CDM project is implemented for 20 years. The costs for producing greenhouse gases CER (certified emission reduction) credits include costs of tree planting and forest management, and costs of project negotiation and transactions for issuing the credits. It is estimated that 376 tones of carbon dioxide per hectare can be accumulated and 503 temporary CER credits per hectare and 265 long-term CER credits per hectare could be produced during the project period. It is estimated to cost US$ 4.04 and US$ 7.67 to provide one unit of temporary credit and long-term credit, respectively. These values can be regarded as the cost of conferring emission commitment of a country or a private entity. However, it is not clear which option is better economically because the replacement periods are different in these two cases.

Probe Vehicle Data Collecting Intervals for Completeness of Link-based Space Mean Speed Estimation (링크 공간평균속도 신뢰성 확보를 위한 프로브 차량 데이터 적정 수집주기 산정 연구)

  • Oh, Chang-hwan;Won, Minsu;Song, Tai-jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.5
    • /
    • pp.70-81
    • /
    • 2020
  • Point-by-point data, which is abundantly collected by vehicles with embedded GPS (Global Positioning System), generate useful information. These data facilitate decisions by transportation jurisdictions, and private vendors can monitor and investigate micro-scale driver behavior, traffic flow, and roadway movements. The information is applied to develop app-based route guidance and business models. Of these, speed data play a vital role in developing key parameters and applying agent-based information and services. Nevertheless, link speed values require different levels of physical storage and fidelity, depending on both collecting and reporting intervals. Given these circumstances, this study aimed to establish an appropriate collection interval to efficiently utilize Space Mean Speed information by vehicles with embedded GPS. We conducted a comparison of Probe-vehicle data and Image-based vehicle data to understand PE(Percentage Error). According to the study results, the PE of the Probe-vehicle data showed a 95% confidence level within an 8-second interval, which was chosen as the appropriate collection interval for Probe-vehicle data. It is our hope that the developed guidelines facilitate C-ITS, and autonomous driving service providers will use more reliable Space Mean Speed data to develop better related C-ITS and autonomous driving services.

Clinical Practice Experience of Men in Nursing as a Student (남자 간호대학생의 임상실습의 경험)

  • Kim, Mi-Hwa;Song, Mi-Sook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.223-229
    • /
    • 2020
  • The study was to understand the meaning and nature of clinical practice by examining the clinical experience of male nursing college students who have experienced clinical practice and to obtain basic data on how male nurses influence the career setting in clinical practice. to be. Participants in this study were male students who are currently in the Department of Nursing at H University, and three snowmen were selected as 3rd grade students and 3rd grade male students who had clinical practice, and analyzed meaningful statements according to Colaizzi data analysis To understand the meaning of students' clinical experience. The findings were divided into three categories, with six themes and 14 meaningful statements. The male nursing students experienced discrimination on the grounds of 'negative nursing image experienced in ward practice', 'the burden of self to be handled', and 'the charm of nursing found in the special part training experience'. Conflict and confusion over the profession were causing. However, among them, the professionalism of the nurses was confirmed and the pleasure of learning was found, and the results of this study can provide a holistic view of the clinical practice experience of male nursing students. In addition, it can be used as a basic data useful for counseling and guidance on academic adaptation and clinical practice adaptation of male nursing college students, and is expected to be useful for counseling career decision after graduation of male nursing students.

Job Competency in Ultrasonography of Korean Radiological Technologists (한국 방사선사의 초음파진단검사 직무역량에 관한 고찰)

  • Lim, Chang Seon;Kim, Chuk Bok;Namkung, Jang Sun;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.857-864
    • /
    • 2019
  • Many countries, including Canada, operate a sonographer license system separately from a radiological technologist license. However, in Korea, radiological technologists perform ultrasound imaging under the guidance of doctors. Therefore, in order to have the opportunity to provide a systematic education by analyzing the job competency of the radiological technologist's ultrasound imaging, based on the Canadian National Competency Profile (NCP) lists, this study measured the job content validity of the job competences and detailed competencies required for performing ultrasonography in Korea. From the results of comparing and analyzing the importance of the core competencies included in the Korean radiological technologist's job competencies and the degree of job performance, the average overall importance was 4.087, the average of overall performance was 3.640, showing that the importance was higher than the performance and that there was a statistically significant difference. In conclusion, 'A Communication', 'B Professional responsibilities', 'D Operation of equipment' and 'G Workplace health and safety' showed high job content validity. However, it is said that as 'C Patient assessment and care', 'E Critical thinking and problem solving', and 'H Image' showed low job content validity, it is necessary to seek ways to strengthen and complement these competencies.