• 제목/요약/키워드: Image equipment

검색결과 971건 처리시간 0.028초

망막의 3차원 실시간 영상화를 위한 고속 동기제어 시스템 개발 (Development of high speed synchronous control system for real time 3D eye imaging equipment)

  • 고종선;김영일;이용재
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.689-692
    • /
    • 2002
  • To show a retina shape and thickness on the computer, a laser has been used in Scanning Laser Ophthalmoscope (SLO) equipment using the travelling difference. This method requires exact synchronize control of laser travelling in optic system to show this image. In this study, a synchronize control of the galvanometer to make 3-dimentional retina image. To obtain a clear 3-dimentional image, this exact synchronism is very Important for making perfect plane scanning.

  • PDF

Fishtail Edge를 이용한 OTF 측정장치의 자동화 (Automation of an OTF measurement system using a fishtail edge)

  • 김태희;최옥식;조현모;이윤우;이인원
    • 한국광학회지
    • /
    • 제8권1호
    • /
    • pp.7-13
    • /
    • 1997
  • 기존에 제작된 칼날주사형 OTF 측정장치의 물체부와 상분석부를 개선하여 측정을 자동화함으로써 MTF 측정 정확도를 향상시켰다. 여러 가지 크기를 갖는 핀홀과 슬릿들을 물체로 사용하였고, fishtail edge를 상분석부의 수평방향에 45.deg로 부착시킴으로써 radial과 tangential 방향의 MTF를 동시에 측정할 수 있도록 하였다. 또한 상분석부의 스텝핑 모터 구동장치와 측정 컴퓨터 프로그램을 개선하였고, SIRA 그룹의 50nm 표준렌즈를 사용하여 OTF 측정장치의 측정 정확도를 평가하였다.

  • PDF

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

데드비트 관측기를 이용한 망막의 3차원 실시간 영상화를 위한 고속 동기제어 시스템 개발 (Development of high speed synchronous control system for real time 3D eye imaging equipment using deadbeat observer)

  • 고종선;김영일;이태훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.177-180
    • /
    • 2002
  • To show a retina shape and thickness on the computer monitor, a laser has been used in Scanning Laser Ophthalmoscope(SLO) equipment using the travelling difference. This method requires exact synchronous control of laser travelling in optic system to show a clear 3-dimensional image of retina. To obtain this image, this exact synchronism is very important for making the perfect plane scanning. In this study, a synchronous control of the galvanometer using deadbeat torque observer to make 3-dimensional retina image is presented. For the more, a very simple mathematical model of the galvanometer is approved by experimental result.

  • PDF

핵의학 투고 논문 분류 및 방향성 고찰 (Classification of submitted nuclear medicine dissertation and directional consideration)

  • 조호연;우영란;서강록;홍건철
    • 핵의학기술
    • /
    • 제26권2호
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

휴대용 열 영상 관측 장비를 위한 전자적 영상 안정화 (Electronic Image Stabilization for Portable Thermal Image Camera)

  • 김종호
    • 한국군사과학기술학회지
    • /
    • 제19권3호
    • /
    • pp.288-293
    • /
    • 2016
  • Electronic Image Stabilization(EIS) is widely used as a technique for correcting a shake of an image. The case requiring the EIS function has been increased in high magnification thermal image observation on portable military equipment. Projection Algorithm(PA) for EIS is easy to implement but its performance is sensitive to the projection area. Especially, projection profiles of thermal image have very modest change and are difficult to extract image shifts between frames. In this paper, we proposed algorithm to extract a feature image for the thermal image and compared Block Matching Algorithm(BMA) with PA using our proposed feature image. When using our proposed feature image, BMA was simply implemented using FPGA's internal small memory. And we were able to obtain 30 % PSNR improved results compared to PA.

Performance Evaluation of Medical Image Transmission System using TH UWB-IR Technology

  • Lee, Yang-Sun;Kang, Heau-Jo
    • Journal of information and communication convergence engineering
    • /
    • 제4권3호
    • /
    • pp.97-100
    • /
    • 2006
  • In this paper, the transmission service for medical image is proposed via IEEE 802.15.4a on WPAN environment. Also, transmission and receiving performance of medical image using TH UWB-IR system is evaluated on indoor multi-path fading environment. On the results, the proposed scheme can solve the problem of interference from the medical equipment in same frequency band, and minimize the loss due to the indoor multi-path fading environment. Therefore, the transmission with low power usage is possible.

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

근적외선 형광 영상시스템의 PWM 제어에 관한 연구 (A Study on PWM Control of Near-Infrared Fluorescence Imaging System)

  • 이병호;반성범
    • 한국정보기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.115-121
    • /
    • 2018
  • 근적외선을 이용한 형광 영상은 방사능에 대한 걱정이 없고 수술 중 실시간으로 영상 확인이 가능한 장점이 있다. 따라서 감시림프절 생검에 형광 영상을 이용하는 실험이 활발히 진행되고 있다. 형광 영상장비는 LED, 카메라와 같은 고발열 부품이 사용되어 안정적인 발열 억제 수단으로 수랭 방식의 쿨링 시스템을 사용하고 있다. 형광 영상장비에서 수랭 쿨링 시스템은 큰 부피를 차지하여 장비의 소형화 측면에서는 단점이 된다. 장비의 소형화를 위해 공랭 쿨링 방식을 이용할 경우 발열이 문제가 된다. 본 논문에서는 장비의 소형화를 위해 PWM 제어를 이용한 공랭 방식을 적용하여 실험을 했고, 장비를 장시간 사용해도 문제가 없는 일정한 품질의 형광 영상과 발열 억제 성능을 확인했다.

Development of Low Price Digital Endoscope with Database System

  • Kim, Sang-Bong;Lee, Young-Hwan;Kim, Sung-Wook;Kim, Suk-Yoel;Jeong, Nam-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.74.2-74
    • /
    • 2001
  • The availability of endoscope has been increased not only for observing inner parts of body but also for operating. Nowdays, the market of the endoscope has been widely extended and we presume that the value of marketablity will reach to wide. Most of the endoscope equipment is very expensive and as well, it costs a lot to repair or change the specific parts of equipment when it´s out of order on account of carelessness. About 90 percent of the endoscope equipment in the world is made in Japan. Therefore, to buy or repair the equipment, we can´t help outflowing foreign currency. In domestic, the efforts for localization and manufacturing the endoscope equipment are short. This paper shows that captured image from a CCD miniature carema is managed ...

  • PDF