• Title/Summary/Keyword: Image compare method

Search Result 629, Processing Time 0.043 seconds

Operation Technique of Spatial Data Change Recognition Data per File (파일 단위 공간데이터 변경 인식 데이터 운영 기법)

  • LEE, Bong-Jun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.184-193
    • /
    • 2021
  • The system for managing spatial data updates the existing information by extracting only the information that is different from the existing information for the newly obtained spatial information file to update the stored information. In order to extract only objects that have changed from existing information, it is necessary to compare whether there is any difference from existing information for all objects included in the newly obtained spatial information file. This study was conducted to improve this total inspection method in a situation where the amount of spatial information that is frequently updated increases and data update is required at the national level. In this study, before inspecting individual objects in a new acquisition space information file, a method of determining whether individual space objects have been changed only by the information in the file was considered. Spatial data files have structured data characteristics different from general image or text document files, so it is possible to determine whether to change the file unit in a simpler way compared to the existing method of creating and managing file hash. By reducing the number of target files that require full inspection, it is expected to improve the use of resources in the system by saving the overall data quality inspection time and saving data extraction time.

Comparison of Subchondral Fracture on Radiographs with MR Images in Evaluation of Osteonecrosis in LCP Patients (LCP 환아에서 골괴사의 평가방법으로 연골하 골절선과 자기공명영상의 비교)

  • Kim, Jin-Won;Park, Mee-Jung;Choi, Ho-Chul;Cho, Jae-Min;Ryoo, Jae-Wook;Jeong, Seong-Hoon;Kim, Dong-Hee;Lee, Gyung-Kyu;Na, Jae-Boem
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.177-182
    • /
    • 2009
  • Purpose : To compare the subchondral fracture on plain radiography and MR image as a method for assessing osteonecrosis in Legg-Calve-Perthes(LCP) pateients. Materials and methods: We retrospetively reviewed 15 hip joint MR images and plain radiography which visualized subchondral fracture. With basis of the Salter-Thompson classification, extent of necrosis was graded group A to B, as follows; Group A = < 50%, B = > 50%. On PACS workstation, necrotic area of each MR image was measured to calculate the volume of necrotic portion: volume = necrotic area $\times$ slice thickness. Necrotic areas on MR images were graded group A to B and results were compared with that measured in Salter-Thompson classification. On follow up, bone resorption was measured and the extent was compared with subchondral fracture representing necrotic area and that on MR volume method respectively. Results : In 9 joints of 15 hip joints (60%), the degree of necrosis in Salter-Thompson classification on plain radiographs was different from that on MR volume method. Based on plain radiographs by Salter-Thompson classification, the degree of necrosis was overestimated in 6(67%) joints, and underestimated in 3(33%) joints compared with MR volume method. On follow up study, bone resorption was not correlated with necrotic extent of subchondral fracture and MR volume method. Conclusion : The extent of femoral head necrosis measured by subchondral fracture was different from that measured by MR and was not correlated with bone resorption on follow up. Therefore, usefulness of subchondral fracture as a prognostic factor may be limited.

  • PDF

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph (디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교)

  • Kim Mi-Ja;Huh Kyung-Hoe;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Lee Jin-Koo;Ahn Byoung-Keun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 2. 3-D VISUALIZATION AND MEASURMENT PROGRAM FOR MAXILLOFACIAL STRUCTURE- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -2. 악안면 구조에 대한 3차원적 시각화 및 측정프로그램 개발-)

  • Lee, Sang-Han;Mori, Yoshihide;Minami, Katsuhiro;Lee, Geun-Ho;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.321-329
    • /
    • 2001
  • To establish systematic diagnosis and treatment planning of dentofacial deformity patient including facial asymmetry or hemifacial microsomia patient, comprehensive analysis of three dimensional structure of the craniofacial skeleton is needed. Even though three dimensional CT has been developed, landmark identification of the CT is still questionable. In recent, a method for correcting cephalic malpositioning that enables accurate superimposition of the landmarks in different stages without using any additional equipment was developed. It became possible to compare the three-dimensional positional change of the maxillomandible without invasive procedure. Based on the principle of the method, a new program was developed for the purpose of diagnosis and treatment planning of dentofacial deformity patient via three dimensional visualization and structural analysis. This program enables us to perform following menu. First, visualization of three dimensional structure of the craniofacial skeleton with wire frame model which was made from the landmarks observed on both lateral and frontal cephalogram. Second, establishment of midsagittal plane of the face three dimensionally, with the concept of "the plane of the best-fit". Third, examination of the degree of deviation and direction of deformity of structure to the reference plane for the purpose of establishing surgical planning. Fourth, simulation of expected postoperative result by various image operation such as mirroring, overlapping.

  • PDF

Effects of Areal Interpolation Methods on Environmental Equity Analysis (면내삽법이 환경적 형평성 분석에 미치는 영향)

  • Jun, Byong-Woon
    • Journal of the Korean association of regional geographers
    • /
    • v.14 no.6
    • /
    • pp.736-751
    • /
    • 2008
  • Although a growing number of studies have commonly used a simple areal weighting interpolation method to quantify demographic characteristics of impacted areas in environmental equity analysis, the results obtained are inevitably imprecise because of the method's unrealistic assumption that population is evenly distributed within a census enumeration unit. Two alternative areal interpolation methods such as intelligent areal weighting and regression methods can account for the distributional biases in the estimation of impacted populations by making use of additional information about the geographic distribution of population. This research explores five areal interpolation methods for estimating the population characteristics of impacted areas in environmental equity analysis and evaluates the sensitivity of the outcomes of environmental equity analysis to areal interpolation methods. This study used GIS techniques to allow areal interpolation to be informed by the distribution of land cover types, as inferred from a satellite image. in both the source and target units. Independent samples t-test statistics were measured to verify the environmental equity hypothesis while coefficients of variation were calculated to compare the relative variability and consistency in the socioeconomic characteristics of populations at risk over different areal interpolation methods. Results show that the outcomes of environmental equity analysis in the study area are not sensitive to the areal interpolation methods used in estimating affected populations, but the population estimates within the impacted areas are largely variable as different areal interpolation methods are used. This implies that the use of different areal interpolation methods may to some degree alter the statistical results of environmental equity analysis.

  • PDF

A Prostate Segmentation of TRUS Image using Average Shape Model and SIFT Features (평균 형상 모델과 SIFT 특징을 이용한 TRUS 영상의 전립선 분할)

  • Kim, Sang Bok;Seo, Yeong Geon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • Prostate cancer is one of the most frequent cancers in men and is a major cause of mortality in the most of countries. In many diagnostic and treatment procedures for prostate disease, transrectal ultrasound(TRUS) images are being used because the cost is low. But, accurate detection of prostate boundaries is a challenging and difficult task due to weak prostate boundaries, speckle noises and the short range of gray levels. This paper proposes a method for automatic prostate segmentation in TRUS images using its average shape model and invariant features. This approach consists of 4 steps. First, it detects the probe position and the two straight lines connected to the probe using edge distribution. Next, it acquires 3 prostate patches which are in the middle of average model. The patches will be used to compare the features of prostate and nonprostate. Next, it compares and classifies which blocks are similar to 3 representative patches. Last, the boundaries from prior classification and the rough boundaries from first step are used to determine the segmentation. A number of experiments are conducted to validate this method and results showed that this new approach extracted the prostate boundary with less than 7.78% relative to boundary provided manually by experts.

Factors Influencing Sexual Satisfaction in Women who have had a Hysterectomy : A comparative group study (자궁적출술을 받은 부인과 자궁적출술을 받지 않은 부인의 성생활 만족 요인 분석)

  • 장순복
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.3
    • /
    • pp.357-367
    • /
    • 1990
  • This descriptive study was done to identify factors influencing sexual satisfaction in women who had had a hysterectomy and to compare these with women who had not had a hysterectomy. The purpose was to contribute theoretical understanding on which to base nursing care planning. One group of subjects were 156 women who had had a hysterectomy, between one and 18 months post surgery, living with their spouse, having no complications, and menstruating before surgery. The other group of subjects were 282 healthy women who were living with their husbands and menstruating. The study tool consisted of 108 items including item concerning personal characteristics, characteristics related to the hysterectomy, husband's support, body image, emotions, attitude toward the sexual relationship, knowledge of sexuality, sexual behavior, and sexual satisfaction. Sexual satisfaction was measured by a tool based on Derogatis Sexual Function Inventory. The range of the internal level of the study tool was from. 5208 to .9462. Data collection was done during the period from June 20 to Aug.20, 1989. The same questionnaire was used of data collection for both groups, but a mail survey method was used for the women who had had a hysterectomy, and an interview method was used for the women who had not had a hysterectomy. Data analysis was done using frequency, ratio, mean and S.D. for the characterstics of the subjects and level of sexual satisfaction. t - test or ANOVA was used for the differences between the groups with regard to the general and hysterectomy related characteristics. The relationship between the score for sex life related factors and the level of sexual satisfaction was analyzed using the Pearson Correlation, and the influencing factors on sexual satisfaction were analyzed by stepwise multiple regression. The results of this study were as follows ; 1. Mean age and income level were the only general characteristics for the two groups that were significantly different. The mean age, and income level of the group who had had a hysterectomy were 45years, and 1,150,000 won respectively, and for those who had not had a hysterectomy, 41 years and 999,000 won. 2. There was no statistical difference of the sexual satisfaction score between the two groups. 3. There was differences in the factors influencing sexual satisfaction between the two groups. Factors influencing sexual satisfaction for the group who had had a hysterectomy were husband's support (R=.5793, P=.000) and the women's Knowledge of sexuality(R=.6670, P=.000) (total variance : 33.56). On the other hand, emotional status(R=.4294, P=.000), sexual behavior(R=.4294, P=.000), husband's support(R=.5274, P=.000) and attitude towards sexual relations (R=.5412, P=.000) (total variance : 54.12) were the factors influencing sexual satisfaction in the group who had not had a hysterectomy. Since husband's support and sexuality knowledge were identified as factors influencing sexual satisfaction of women who have had a hysterectomy, it can be concluded that, before a woman who has had a hysterectomy is discharged from hospital, nurses should include strategies in the nursing care plan that will promote husband's support and the women's knowledge of sexuality.

  • PDF

New method of assessing the relationship between buccal bone thickness and gingival thickness

  • Kim, Yun-Jeong;Park, Ji-Man;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Rhyu, In-Chul;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.372-381
    • /
    • 2016
  • Purpose: The aim of this study was to determine the relationship between buccal bone thickness and gingival thickness by means of a noninvasive and relatively accurate digital registration method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomographic images and intraoral scanned files were obtained. Measurements of buccal bone thickness and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. The Friedman test was used to compare buccal bone and gingival thickness for each depth between the 3 tooth types. Spearman's correlation coefficient was calculated to assess the correlation between buccal bone thickness and gingival thickness. Results: Of the central incisors, 77% of all sites had a buccal thickness of 0.5-1.0 mm, and 23% had a thickness of 1.0-1.5 mm. Of the lateral incisors, 71% of sites demonstrated a buccal bone thickness <1.0 mm, as did 63% of the canine sites. For gingival thickness, the proportion of sites <1.0 mm was 88%, 82%, and 91% for the central incisors, lateral incisors, and canines, respectively. Significant differences were observed in gingival thickness at the alveolar crest level (G0) between the central incisors and canines (P=0.032) and between the central incisors and lateral incisors (P=0.013). At 1 mm inferior to the alveolar crest, a difference was found between the central incisors and canines (P=0.025). The lateral incisors and canines showed a significant difference for buccal bone thickness 5 mm under the alveolar crest (P=0.025). Conclusions: The gingiva and buccal bone of the anterior maxillary teeth were found to be relatively thin (<1 mm) overall. A tendency was found for gingival thickness to increase and bone thickness to decrease toward the root apex. Differences were found between teeth at some positions, although the correlation between buccal bone thickness and soft tissue thickness was generally not significant.