• Title/Summary/Keyword: Image Plate

Search Result 680, Processing Time 0.024 seconds

Experimental Study on Turbulent Structure of Flow over a Micro Riblet Plate (미세 Riblet 평판에서의 난류구조 변화에 관한 실험적 연구)

  • Choi, Yong-Seok;Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.375-376
    • /
    • 2006
  • Turbulent structure of a boundary-layer over a flat plate coated with micro riblet film(MRF) has been investigated experimentally. The turbulent structure was visualized using a dynamic particle image velocimetry (Dynamic PIV) system. We identified the vortex structures from 2-D velocity field data by applying the complex eigenvalue definition. The velocity field images acquired by using the complex eigenvalue definition showed the whole 2-D vortex structures clearly. In addition, the spatial distributions of small-scale vortices as well as large-scale vortices were obtained with high accuracy. The difference of vortex structures between the MRF coated flat plate and the smooth flat plate was analysed in detail. With varying upstream flow speed, the characteristics of vortex structure over the MRF coated flate plate was compared with those over the smooth flat plate.

  • PDF

Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate (어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가)

  • Kim Sang Hoo;Kim Hyung Jun;Han Eun Ok;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.551-556
    • /
    • 2004
  • The purpose of this study was to suggest a systematic and scientific method for measurement of children's growth development, in which the accuracy of existing diagnosis method has not been concretely examined yet. The most popular method for diagnosis of children's growth is to analyze the opening degree of growth plate in each joint by X-ray image. However, X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analyzing the image of growth plate with the BUA(Broadband Ultrasound Attenuation) of calcaneus, to verify the possibility of alternative ultrasonic method harmless to human body. We obtained the images of growth plate in proximal tibiae, phalanges, and calcanei of 269 children (7∼16 years old) with X-ray. And the image of growth plate in calcanei was also obtained front those children with ultrasound. The results showed that the time of the opening degree of growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of growth plate measured by X-ray and ultrasound showed the high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly.

A Sub-Wavelength Focusing Lens Composed of a Dual-Plate Metamaterial Providing a Negative Refractive Index

  • Kim, Dong-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.26-31
    • /
    • 2012
  • We have proposed a metamaterial lens that enables sub-wavelength focusing, which is shorter than an operating wavelength. Our lens is a two dimensional array of a unit cell consisting of a metallic dual-plate printed on a dielectric substrate. The unique dual-plate structure provides negativeness both in permittivity and permeability, with no help from conventional additional structures, which are normally printed on the opposite of metallic patterns. Therefore, we can focus a source (or an image) in a tiny distance shorter than the free space wavelength (${\lambda}$) at the frequencies of interest. Furthermore, since the proposed geometry does not need separate supplementary structures to acquire negative permittivity or permeability, our lens is much simpler than conventional metamaterial lenses, which is a strong point in practical applications. We have validated sub-wavelength focusing ability in a 6 GHz frequency band through an experiment of near field scanning, which provided the width of about 0.19 ${\lambda}$ at a half maximum of a peak value of an measured image. The width of the focused image through the lens is more than 4 times shorter than that without the lens, which confirms the validity of our design approach.

Defect Analysis of Phospher (Ba, Sr) FBr : Eu by X-Ray Irradiation (X선 조사에 의해 (Ba, Sr) FBr : Eu 형광 물질에 생성되는 결함 특성)

  • Shin, Jung-Ki;Lee, Chong-Yong;Bae, Seok-Hwan;Kim, Jae-Hong;Kwon, Jun-Hyun
    • Korean Journal of Materials Research
    • /
    • v.18 no.8
    • /
    • pp.427-431
    • /
    • 2008
  • The mechanical property of a phosphore layer was investigated by measuring the resolution (LP/mm) and by positron annihilation spectroscopy and SEM. Image plate samples containing the phosphore layer were irradiated by X-rays in a hospital numerous times over a course of several years. The LP/mm values of a (Ba,Sr)FBr : Eu image plate irradiated by X-rays varied between 2.2 and 2.0 over a period of four years. Coincidence Doppler Broadening (CDB) positron annihilation spectroscopy was used to analyze defect structures. The S parameters of the samples from hospital use varied from 0.6219 to 0.6232. There was a positive relationship between the time of exposure to the X-rays and the S parameters. Most of the defects were found to have been generated by X-rays.

A Development on the Non-Photomask Plate Making Technology for Screen Printing (II) (포토마스크가 필요 없는 스크린 제판 기술 개발(II))

  • Park, Kyoung-Jin;Kang, Hyo-Jin;Kim, Sung-Bin;Nam, Su-Yong;Ahn, Byung-Hyun
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.26 no.2
    • /
    • pp.45-54
    • /
    • 2008
  • We have manufactured a photoresist which has excellent dispersity and good applying property due to 330 cps of viscosity for environment-friendly and economical maskless screen plate making. And the photoresist applied on the screen stretched was exposed with mask by UV-LED light source so we could manufacture the photoresist which proper for the UV light source. And it was developed by air spray with $1.7\;kgf/cm^2$ of injection pressure. Because of the excellence of power and resolution of the UV-LED light sourse, the pencil hardness and solvent resistance of curing photoresist film were excellent as those of conventional photoresist film. Moreover the $100{\mu}m$-width stripe image which has sharp edges was formed. So we confirmed a possibility of dry development process by air spray method.

  • PDF

Equivalent Scattering Area Model of Optical Dot Gain (광학적 망점확대의 상당산란면적 모델에 관한 연구)

  • 강상훈
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.43-55
    • /
    • 1994
  • To investigate relations between Grain-shape of plate and Dot-Gain in the lithography, Printing plates were made by Mechanical Grain, Brush Grain and Electrolytic Grain method.Fine multi-grain by electrolytic method of them resulted in less Dot-grain on the paper, more damping water on the none image part of printing plate.

  • PDF

Enhancement of Image Quality Using Detector Filter (검출기 필터를 이용한 화질의 향상)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Kim, Min-Hye;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.451-456
    • /
    • 2016
  • Radiation dose to patient is unavoidable when diagnosis is carried out using X-ray. Radiation diagnosis using dual energy X-ray was examined to verify the possibility of medical applications by SNR and image scoring. The dual energy X-ray was realized by combining together two image plates and filter of 0.5 mm thick Cu or Al. Under one X-ray exposure, contrast enhanced image was obtained using two images of image plates. The enhanced image showed higher SNR and image score compared to the first image which was the image recorded with the first image plate. The dual energy X-ray technique would be a very useful method for obtaining higher SNR image and for realizing very low dose, and could be applied to medical applications.

Study on Performance Evaluation of Automatic license plate recognition program using Emgu CV (Emgu CV를 이용한 자동차 번호판 자동 인식 프로그램의 성능 평가에 관한 연구)

  • Kim, Nam-Woo;Hur, Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.6
    • /
    • pp.1209-1214
    • /
    • 2016
  • LPR(License plate recognition) is a kind of the most popular surveillance technology based on accompanied by a video and video within the optical character recognition. LPR need a many process. One is a localization of car license plates, license plate of size, space, contrast, normalized to adjust the brightness, another is character division for recognize the character optical character recognition to win the individual characters, character recognition, the other is phrase analysis of the shape, size, position by year, the procedure for the analysis by comparing the database of license plate having a difference by region. In this paper, describing the results of performance of license plate recognition S/W, which was implemented using EmguCV, find the location, using the tesseract OCR, which are well known to an optical character recognition engine of open source, the characters of the license plate image capturing angle of the plate, image size, brightness.

Number Region Extraction of License Plates Using Colors and Arrangement of Numbers (색상과 배치 정보를 이용한 번호판 숫자 영역 추출)

  • Oh, Bok-Jin;Choi, Doo-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.9
    • /
    • pp.1117-1124
    • /
    • 2011
  • This paper proposes a plate number extraction method which uses the information of both the colors and the arrangement of numbers in a vehicle image with complex background. In a number plate, color of the numbers is usually black or white, and numbers are arranged in a row. At first, a raw image is partitioned into the plate number candidate regions and non-interest region. The number candidate regions are thresholded in mean binarization. After eliminating the illegal candidate regions using the aspect ratio of the plate number, the plate number region is finally extracted by using the arrangement information among the numbers. To evaluate the proposed mothed, 292 images are taken in various places and at different times. The experimental results show that the rate of the proposed number regions extraction is about 89.8%, 95.5% for the plate of green and white backgrounds, respectively.

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography (초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.4 s.287
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.