• Title/Summary/Keyword: Image Mode

Search Result 865, Processing Time 0.027 seconds

Colour Interpolation of Tongue Image in Digital Tongue Image System Blocking Out External Light (디지털 설진 시스템의 색상 보정)

  • Kim, Ji-Hye;Nam, Dong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2012
  • Objectives The aim of this study is to propose an optimized tongue colour interpolation method to achieve accurate tongue image rendering. Methods We selected 60 colour chips in the chips of DIC color guide selector, and then divided randomly the colour chips into two groups. The colour chips of a group (Gr I) were used for finding the optimized colour correction factor of error and those of the other group (Gr II) were used for verifying the correction factor. We measured colour value of the Gr I colour chips with spectrophotometer, and took the colour chips image with a digital tongue image system (DTIS). We adjusted colour correction factor of error to equal the chip colour from each method. Through that process, we obtained the optimized colour correction factor. To verify the correction factor, we measured colour value of the Gr II colour chips with a spectrophotometer, and took the colour chips image with the DTIS in the two types of colour interpolation mode (auto white balance mode and optimized colour correction factor mode). And then we calculated the CIE-$L^*ab$ colour difference (${\Delta}E$) between colour values measured with the spectrophotometer and those from images taken with the DTIS. Results In auto white balance mode, The mean ${\Delta}E$ between colour values measured with the spectrophotometer and those from images taken with the DTIS was 13.95. On the other hand, in optimized colour correction factor mode, The mean ${\Delta}E$ was 9.55. The correction rate was over 30%. Conclusions In case of interpolating colour of images taken with the DTIS, we suggest that procedure to search the optimized colour correction factor of error should be done first.

Comparisons of Image Quality Characteristics in Homogeneously Aligned Nematic Liquid Crystal Modes (수평 배향된 네마틱 액정 모드들의 화질 특성 비교)

  • Jung, Byoung-Sun;Kim, Tae-Hyun;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.100-103
    • /
    • 2005
  • Homogeneously aligned nematic liquid crystal modes are representatively the -FFS (fringe-field switching) mode using liquid crystal (-LC) with negative dielectric anisotropy, the +FFS mode and the IPS (in-plane switching) mode using +LC with positive dielectric anisotropy. In view of image quality evaluation standard of LCD, we compared characteristics of the brightness, the contrast ratio (CR) and color shift when the modes have respectively optimized phase retardation values $(d{\Delta}n)$. Consequently, in the most sensitively viewing angle of a man's physical vision, both FFS modes have advantage over the IPS mode from the brightness & the CR point of view. We are also confirmed that the +FFS mode out of them shows the smallest color shift according to all viewing directions in grey levels.

  • PDF

Interframe Coding for 3-D Medical Images Using an Adaptive Mode Selection Technique in Wavelet Transform Domain (웨이블릿 변환 영역에서의 적응적 모드 선택 기법을 이용한 3차원 의료 영상을 위한 interframe 부호화)

  • 조현덕;나종범
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.265-274
    • /
    • 1999
  • In this paper, we propose a novel interframe coding algorithm especially appropriate for 3-D medical images. The proposed algorithm is based on a video coding algorithm using motion estimation/ compensation and transform coding. In the algorithm, warping is adopted lor motion compensation (MC). Then, by using adaptive mode selection, a motion compensated residual image and original image are mixed up in the wavelet transform domain for improvement in coding performance. The mixed image is then compressed by the zerotree coding method. We prove that the adaptive mode selection technique in the wavelet transform domain is very useful lor 3-D medical image coding. Simulation results show that the proposed scheme provides good performance regardless of inter-slice distance and is prospective for 3-D medical image compression.

  • PDF

A study on quality transformation of Digital printing photograph according to Comporession Method (압축방식에 따른 디지털 인쇄사진의 품질 변화에 관한 연구)

  • Cho, Ga-Ram;Koo, Chul-Whoi
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.21 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • Because of computer developing, the digital image making the use of many a field of application with - web-above, electronic publishing. printing, dynamic image management and photo CD production etc., however many problems of save and management. The management image use of compression moth which don't have a affect on image, reduce file size. A study used sequential DCT0based mode and progressive DCT-based mode of JPEG(Joing Photographic Experts Group) compression method and Wavelet compression method. Therefore, the analog image and digital image was changed and applied by several stages according to compression rate. It made inquiries of the optimum compression rate that be compared quality transformation between original image and compressed image. As compression image was printing simply, the quality was studied by subjective valuation method, that was studied propriety and usefulness.

  • PDF

Fast Inter Block Mode Decision Using Image Complexity in H.264/AVC (H.264/AVC에서 영상 복잡도를 이용한 고속 인터 블록 모드 결정)

  • Kim, Seong-Hee;Oh, Jeong-Su
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.11C
    • /
    • pp.925-931
    • /
    • 2008
  • In video coding standard H.264/AVC, variable block size mode algorithm improves compression efficiency but has need of a large amount of computation for various block modes and mode decision. Meanwhile, decided inter block modes depend on the complexity of a block image, and then the more complex a macroblock is, the smaller its block size is. This paper proposes fast inter block mode decision algorithm. It limits valid block modes to the block modes with a great chance for decision using the image complexity and carries out motion estimation rate-distortion optimization with only the valid block modes. In addition to that, it applies fast motion estimation PDE to the valid block modes with only the $16{\times}16$ block mode. The reference software JM 9.5 was executed to estimate the proposed algorithm's performance. The simulation results showed that the proposed algorithm could save about 24.12% of the averaged motion estimation time while keeping the image quality and the bit rate to be -0.02dB and -0.12% on the average, respectively.

3D Image Representation Using Color Correction Matrix According to the CCT of a Display (디스플레이 상관 색온도에 따른 색 보정 매트릭스를 이용한 3D 영상 재생)

  • Song, Inho;Kwon, Hyuk-Ju;Kim, Tae-Kyu;Lee, Sung-Hak
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.1
    • /
    • pp.55-61
    • /
    • 2019
  • Almost all 3D displays have a brightness reduction in the 3D mode comparing to the 2D mode. When the brightness is reduced, one of the color attributes, the colorfulness, is decreased. In this case, the viewer feels that the image quality is deteriorated. In this paper, we proposed a method to compensate for the degradation of colorfulness due to brightness reduction in 3D mode for high quality 3D image viewing using the CIECAM02 model and the color correction matrix. As a result of applying the proposed method, we can confirm that the colorfulness is improved in 3D mode.

Dual-Sensitivity Mode CMOS Image Sensor for Wide Dynamic Range Using Column Capacitors

  • Lee, Sanggwon;Bae, Myunghan;Choi, Byoung-Soo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.85-90
    • /
    • 2017
  • A wide dynamic range (WDR) CMOS image sensor (CIS) was developed with a specialized readout architecture for realizing high-sensitivity (HS) and low-sensitivity (LS) reading modes. The proposed pixel is basically a three-transistor (3T) active pixel sensor (APS) structure with an additional transistor. In the developed WDR CIS, only one mode between the HS mode for relatively weak light intensity and the LS mode for the strong light intensity is activated by an external controlling signal, and then the selected signal is read through each column-parallel readout circuit. The LS mode is implemented with the column capacitors and a feedback structure for adjusting column capacitor size. In particular, the feedback circuit makes it possible to change the column node capacitance automatically by using the incident light intensity. As a result, the proposed CIS achieved a wide dynamic range of 94 dB by synthesizing output signals from both modes. The prototype CIS is implemented with $0.18-{\mu}m$ 1-poly 6-metal (1P6M) standard CMOS technology, and the number of effective pixels is 176 (H) ${\times}$ 144 (V).

Image Noise Reduction Using Structural Mode Shaping for Scanning Electron Microscopy

  • Hamochi, Mitsuru;Wakui, Shinji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.28-33
    • /
    • 2008
  • In a scanning electron microscope (SEM), outside acoustic noise causes image noise that distorts observations of the specimen being examined. A SEM that is less sensitive to acoustic noise is highly desirable. This paper investigates the image noise problem by addressing the mode shapes of the base plate and the transmission path of the acoustic noise and vibration. By arranging the position of the rib, a new SEM base plate was developed that had twisting as the 1st and 2nd modes. In those two twisting modes, vibration nodes existed near the center of the base plate where the specimen chamber is placed. Less vibration was transmitted to the chamber and to the specimen by the twisting modes compared to bending ones, which are the 2nd and 3rd modes for a rectangular plain base plate. An SEM with the developed base plate installed exhibited a significant reduction of image noise when exposed to acoustic noises below 250 Hz.

Developement of Small 360° Oral Scanner Embedded Board for Image Processing (소형 360° 구강 스캐너 영상처리용 임베디드 보드 개발)

  • Ko, Tae-Young;Lee, Sun-Gu;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1214-1217
    • /
    • 2018
  • In this paper, we propose the development of a Small $360^{\circ}$ Oral Scanner embedded board. The proposed small $360^{\circ}$ oral scanner embedded board consists of image level and transfer method changing part FPGA part, memory part and FIFO to USB transfer part. The image level and transmission mode change unit divides the MIPI format oral image received through the small $360^{\circ}$ oral cavity image sensor and the image sensor into low power signal mode and high speed signal mode and distributes them to the port and transfers the level shift to the FPGA unit. The FPGA unit performs functions such as $360^{\circ}$ image distortion correction, image correction, image processing, and image compression. In the FIFO to USB transfer section, the RAW data transferred through the FIFO in the FPGA is transferred to the PC using USB 3.0, USB 3.1, etc. using the transceiver chip. In order to evaluate the efficiency of the proposed small $360^{\circ}$ oral scanner embedded board, it has been tested by an authorized testing institute. As a result, the frame rate per second is over 60 fps and the data transfer rate is 4.99 Gb/second

A Study of the TM-TE Mode Conversion in Dielectric Waveguide Grating Structures (유전체 도파관 격자구조에서 TM-TE 모드 변환에 관한 연구)

  • Park, Dong-Chul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.553-558
    • /
    • 1987
  • A design method of dielectric image-guide grating structures which are applicable for the millimeter-wave system is presented. A dielectric image-guide grating with notches in the sides and also another grating with notches in the top have been designed, fabricated and tested with TM-and TE-mode excitations. From the esperimental results the relatin between TM-TE mode symmetry in the grating structure has been investigated.

  • PDF