• Title/Summary/Keyword: Image Intensity

Search Result 1,681, Processing Time 0.023 seconds

Two Cases of Avascular Necrosis of the Femur Head after Whole Pelvic Radiation Therapy for the Treatment of Cervical Cancer (자궁경부암의 전골반방사선치료 후 발생한 대퇴골두 무혈성괴사 2예)

  • Yu, Jeong-Il;Huh, Seung-Jae;Park, Won;Oh, Dong-Ryul;Lee, Jung-Ae
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.126-130
    • /
    • 2008
  • Avascular necrosis(AVN) is a disease characterized by the temporary or permanent loss of the blood supply to the bones, resulting from many possible causes, including radiation therapy. The femoral head is known to be the most common site of AVN. The authors encountered two cases of AVN of the femoral head among 557 patients with cervical cancer treated with whole pelvic radiation therapy at the Samsung Medical Center. AVN of the femoral head was presented with a sclerotic density change in a plain roentgenography and a decreased signal intensity lesion on the T1 and T2 weighted phases of a magnetic resonance image(MRI). Although it is a very rare complication after whole pelvic radiation therapy, AVN of the femoral head should be considered when characteristic imaging findings appear on follow-up examinations.

A Study on the Color of Neo-Impressionism on the Fabric Pattern of Modern Fashion - From 1987 To 1991- (현대의상 직물 문양에 조명된 신인상주의 색채 표현에 관한 연구 -1987년부터 1991년까지-)

  • Lee Hyo Jin;Jung Heung Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.3 s.43
    • /
    • pp.209-221
    • /
    • 1992
  • A standpoint art's style, present-day Western dress was establishing a systematic, theoritical value in sphere of fine art's meaning & it's expression on the modern fashion. For this reason, I selected Impressionism (a broad senes: be included Impressionism, Neo-Impressionism, Post-Impressionism) that was designated 'the revolution of color'. In the previous paper, 1 already discussed about the modern fashion under the influence of the color of Impressionism, from this study, Neo-Impressionism's techniques & it's influence on the modern fashion was investigated. The Impressionists had purposely used uneven brushwork & a vivid palette to transmit the intensity & immediacy of nature, whereas the Neo-Impressionists utilized methodically applied dots, a technique commonly described as Pointillism, to achieve their rationalist goal of eliminating the fugitive & the casual in order to seize a more fundamental reality. Of all them, Seurat had already become interested in the posible analogies between science, music & psychology on the on hand & art on the other, and scientist's books & articles offered a wealth of theoretical support. 1'articulary, it was corroborated that effects of sadness, calm, or happiness could be achieved through manipulation of color & design. The conclusions are as follow: 1. Through the modern fashion, a space between pattern & pattern was reflected unstable balances & harmonies, that, Neo-Impressionist emphasized the distinction between outdoor & subject, between elaborately clothed & nude figures, corresponded to modern fashion's pattern. 2. The modern fashion was presented a small border or band within the pattern itself which colors complemented those of the adjacent pictorial surface and mediated between the painted image & its enclosure.

  • PDF

A CMOS active pixel sensor with embedded electronic shutter and A/D converter (전자식 셔터와 A/D 변환기가 내장된 CMOS 능동 픽셀 센서)

  • Yoon, Hyung-June;Park, Jae-Hyoun;Seo, Sang-Ho;Lee, Sung-Ho;Do, Mi-Young;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.272-277
    • /
    • 2005
  • A CMOS active pixel sensor has been designed and fabricated using standard 2-poly and 4-metal $0.35{\mu}m$ CMOS processing technology. The CMOS active pixel sensor has been made up of a unit pixel having a highly sensitive PMOSFET photo-detector and electronic shutters that can control the light exposure time to the PMOSFET photo-detector, correlated-double sampling (CDS) circuits, and an 8-bit two-step flash analog to digital converter (ADC) for digital output. This sensor can obtain a stable photo signal in a wide range of light intensity. It can be realized with a special function of an electronic shutter which controls the light exposure-time in the pixel. Moreover, this sensor had obtained the digital output using an embedded ADC for the system integration. The designed and fabricated image sensor has been implemented as a $128{\times}128$ pixel array. The area of the unit pixel is $7.60{\mu}m{\times}7.85{\mu}m$ and its fill factor is about 35 %.

A study on Hemo-Dynamic information Within 30 seconds in DCE 3D Breast MRI : Experienced Reports (DCE 3D Breast MRI 검사 시 30 sec 이내에 혈류 역학적 정보에 대한 연구 : Experienced Reports)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • The purpose of this study evaluated the hemo-dynamic information within 30 seconds clinically in 3D breast MRI. From January to March 2014, A total of 40 people were examined at 1.5 Tesla(Philips, Medical System, Achieva, The Netherlands) MRI equipments using 16 channel SENSE breast coil. The imaging parameters on vibrant are fellow as: $TR/TE/FA^{\circ}$/Matrix size/Slice thickness/Slab($5ms/2ms/10^{\circ}/180{\times}139{\times}2mm/80$). This study used a Gadovist and injected it with injection speed of 4 ml /sec by auto injector with 15 ml saline flushing. Firstly, for the delay time study, it divided three different delay time from immediately, 20 seconds, and 30 seconds. In quantitative analysis, the ROI signal intensities of tumor and surrounding tissues were measured retrospectively. In qualitative analysis, the image quality was scored from 1 to 5 point by one experienced radiological technologists as a visual test. The significance level of each delay time was evaluated with a one-way ANOVA(p<0.05). In the visual test, score levels on 30 seconds delay time was a little bit higher than others(p<0.05). The signal intensity of the tumor were $1445{\pm}360$, $1410{\pm}320$, $1510{\pm}415$ on immediately, 20 seconds, and 30 seconds and score levels were $4.18{\pm}0.85$, $3.54{\pm}0.94$, $4.45{\pm}0.74$(p<0.05). The data on immediate images showed better results than that others(p<0.05). Conclusively, Although it has been high scored in 30sec delay time for visual test in order to avoid failure in 20second, 30seconds delay time after contrast media administration, we recommend that the DCE 3D breast MRI commence immediately.

  • PDF

Quantitative Analysis of Metallographic Characteristics with Austenitizing Temperature in STD 11 Steel (STD 11 강의 오스테나이트화 온도에 따른 제 특성의 정량 분석)

  • Kim, J.E.;Ju, Y.H.;Jang, W.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.30 no.5
    • /
    • pp.215-221
    • /
    • 2017
  • The effect of austenitizing temperature on the degree of carbides re-solutionizing, mean graine size, hardness and the volume fraction of retaind austenite ($V_{\gamma}$) etc., has been studied by means of metallography, X-ray diffractometry and hardness measurement in STD 11 tool steel. As austenitizing temperature increases, the amount of alloying elements which is re-dissolved into matrix increases, resulting in increase of $V_{\gamma}$, due to the chemical stabilization of austenite. The Vickers hardness value decreases with increasing austenitizing temperature, which is attributed to grain size as well the volume fractions of $V_{\gamma}$ and carbides. Theoretical diffraction intensity of (200) ${\alpha}^{\prime}$, (211) ${\alpha}^{\prime}$ (200) ${\gamma}$ and (220) ${\gamma}$ peaks obtained by $CuK_{\alpha}$ chracteristics X-ray (${\lambda}=0.15429nm$) was calculated, and quantitative analysis of $V_{\gamma}$ could be carried out by X-ray diffraction method. The resultant value is well coincided with the value obtained by image analysis method. When the quenched specimen is tempered above $200{\sim}400^{\circ}C$ for 30 min, the transition carbides i.e., MC and $M_2C$ in the size of about 20 nm begin to precipitate at $300^{\circ}C$.

A Lane Detection and Departure Warning System Robust to Illumination Change and Road Surface Symbols (도로조명변화 및 노면표시에 강인한 차선 검출 및 이탈 경고 시스템)

  • Kim, Kwang Soo;Choi, Seung Wan;Kwak, Soo Yeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.6
    • /
    • pp.9-16
    • /
    • 2017
  • An Algorithm for Lane Detection and Lane Departure Warning for a Vehicle Driving on Roads is proposed in This Paper. Using Images Obtained from On-board Cameras for Lane Detection has Some Difficulties, e.g. the Increase of Fault Detection Ratio Due to Symbols on Roads, Missing Yellow Lanes in the Tunnel due to a Similar Color Lighting, Missing Some Lanes in Rainy Days Due to Low Intensity of Illumination, and so on. The Proposed Algorithm has been developed Focusing on Solving These Problems. It also has an Additional Function to Determine How much the Vehicle is leaning to any Side between The Lanes and, If Necessary, to Give a Warning to a Driver. Experiments Using an Image Database Built by Collecting with Vehicle On-board Blackbox in Six Different Situations have been conducted for Validation of the Proposed Algorithm. The Experimental Results show a High Performance of the Proposed Algorithm with Overall 97% Detection Success Ratio.

Design and fabrication of a holographic scanner using the ray tracing method (광선 추적을 이용한 홀로그래픽 스캐너의 설계 및 제작)

  • 김종재;정만호
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.107-113
    • /
    • 1999
  • Low-aberration holographic scanners that eliminate the need for lenses and mirrors promise to greatly reduce the cost of laser printers and image scanners. In this study, a holographic optical element that can simultaneously scan and focus a laser beam is designed with analytic ray tracing method. An analytic and experimental work is conducted in which we investigated the hologram structure and hologon configuration for linear aberration-free scanning. For a prototype scanner, a He-Ne laser is used to manufacture and reconstruct the hologram, and the measured bow is about $\pm$133$\mu\textrm{m}$ and spot size(half-intensity beamwidth) in under 100$\mu\textrm{m}$ for a 300 mm scan length without using a correcting lens or mirror. The diffraction efficiency is about 55$\pm$5%, which is acceptably flat. The experimentally measured results agrees with the computed values. From this fact, we can conclude that the computed results using ray tracing method are practical and useful values, and have a potential for use in high resolution laser printers.

  • PDF

Properties of Defective Regions Observed by Photoluminescence Imaging for GaN-Based Light-Emitting Diode Epi-Wafers

  • Kim, Jongseok;Kim, HyungTae;Kim, Seungtaek;Jeong, Hoon;Cho, In-Sung;Noh, Min Soo;Jung, Hyundon;Jin, Kyung Chan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.687-694
    • /
    • 2015
  • A photoluminescence (PL) imaging method using a vision camera was employed to inspect InGaN/GaN quantum-well light-emitting diode (LED) epi-wafers. The PL image revealed dark spot defective regions (DSDRs) as well as a spatial map of integrated PL intensity of the epi-wafer. The Shockley-Read-Hall (SRH) nonradiative recombination coefficient increased with the size of the DSDRs. The high nonradiative recombination rates of the DSDRs resulted in degradation of the optical properties of the LED chips fabricated at the defective regions. Abnormal current-voltage characteristics with large forward leakages were also observed for LED chips with DSDRs, which could be due to parallel resistances bypassing the junction and/or tunneling through defects in the active region. It was found that the SRH nonradiative recombination process was dominant in the voltage range where the forward leakage by tunneling was observed. The results indicated that the DSDRs observed by PL imaging of LED epi-wafers were high density SRH nonradiative recombination centers which could affect the optical and electrical properties of the LED chips, and PL imaging can be an inspection method for evaluation of the epi-wafers and estimation of properties of the LED chips before fabrication.

Multimodal Nonlinear Optical Microscopy for Simultaneous 3-D Label-Free and Immunofluorescence Imaging of Biological Samples

  • Park, Joo Hyun;Lee, Eun-Soo;Lee, Jae Yong;Lee, Eun Seong;Lee, Tae Geol;Kim, Se-Hwa;Lee, Sang-Won
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.551-557
    • /
    • 2014
  • In this study, we demonstrated multimodal nonlinear optical (NLO) microscopy integrated simultaneously with two-photon excitation fluorescence (TPEF), second-harmonic generation (SHG), and coherent anti-Stokes Raman scattering (CARS) in order to obtain targeted cellular and label-free images in an immunofluorescence assay of the atherosclerotic aorta from apolipoprotein E-deficient mice. The multimodal NLO microscope used two laser systems: picosecond (ps) and femtosecond (fs) pulsed lasers. A pair of ps-pulsed lights served for CARS (817 nm and 1064 nm) and SHG (817 nm) images; light from the fs-pulsed laser with the center wavelength of 720 nm was incident into the sample to obtain autofluorescence and targeted molecular TPEF images for high efficiency of fluorescence intensity without cross-talk. For multicolor-targeted TPEF imaging, we stained smooth-muscle cells and macrophages with fluorescent dyes (Alexa Fluor 350 and Alexa Fluor 594) for an immunofluorescence assay. Each depth-sectioned image consisted of $512{\times}512$ pixels with a field of view of $250{\times}250{\mu}m^2$, a lateral resolution of $0.4{\mu}m$, and an axial resolution of $1.3{\mu}m$. We obtained composite multicolor images with conventional label-free NLO images and targeted TPEF images in atherosclerotic-plaque samples. Multicolor 3-D imaging of atherosclerotic-plaque structural and functional composition will be helpful for understanding the pathogenesis of cardiovascular disease.

Visual Preference Evaluation on Forest Working Systems' Characteristics for Forest Scenic Beauty Management (산림풍치자원관리(山林風致資源管理)를 위한 산림시업특성별(山林施業特性別) 시각선호도(視覺選好度) 평가(評價))

  • Song, Hyung Sop
    • Journal of Korean Society of Forest Science
    • /
    • v.88 no.3
    • /
    • pp.309-319
    • /
    • 1999
  • This study was conducted to get forest scenic beauty management information toward forest working systems; characteristics in Larix forest stands. 35 different alternatives were simulated to visualize on basis of actual forest working methods. The options were illustrated as photos produced by computer software. Each alternatives were evaluated by 3 groups with total 593 respondents after reliability test. Visual preference evaluation was used 1 - 10 point rating scale. The ratings were scaled using SBE analysis program of RMRATE. To compare the relationship of visual preference and image scale, Spatial images of 13 thinning alternatives were measured by Semantic differential scale. In general, the respondents preferred refreshing and ordering forest stand after forest working to natural forest stand before forest working. Visual preference decreased with the increasing intensity of bare ground area and slash area in forest stand. And also, visual preference was high related to tree density, clear length of stem, and ground vegetation. Farm line of small clear cutting area was preferred straight line to curve line. Visual preferences were significant differences in certain socioeconomic variables of the respondents. Results indicate how to conduct forest working system for forest scenic beauty management.

  • PDF