• 제목/요약/키워드: Image Intensifier Camera

검색결과 14건 처리시간 0.031초

CCD 카메라를 사용한 저가형 Digital X-Ray 영상취득 시스템 (Low Cost Digital X-Ray Image Capture System Using CCD Camera)

  • 강용철
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.19-22
    • /
    • 2007
  • We developed a low cost digital X-Ray image capturing system using a CCD camera, instead of using the high cost image plate and image intensifier. In order to reduce the system volume, we directly made the dark box shorter than the previous model. Using the graphic language, we developed a program in order for post-processing the images captured by the CCD camera. This program improves the image resolving power.

PIV에 의한 가정용 온수펌프의 유동장 계측 (Measurement of Flow Field in a Domestic Hot-Water Pump by PIV)

  • 이현;임유청;김재현;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.264-271
    • /
    • 1999
  • The present experimental study is aimed to investigate the flow characteristics of the high-speed flow field within hot-water pump by PIV(Particle Image Velocimetry). As multi-point simultaneous velocity acquisition, 2-D PIV system based upon the two-frame gray-level cross correlation method is adopted using PC frame-grabber and simple video system. Gated image intensifier CCD Camera to cope with illumination problem is arranged for accurate PIV measurement of high-speed complex flow. The velocity vector distribution, velocity profile, and kinetic energy are represented quantitatively at the full-scale region for the deeper understanding of the unsteady flow characteristics in a pump.

  • PDF

X-선 영상 시스템의 정밀 캘리브레이션 기법 (An Accurate Calibration Technique for X ray Imaging System)

  • 조영빈;권대갑
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.198-207
    • /
    • 1999
  • This paper presents an accurate algorithm for geometric calibration of X-ray imaging system. Calibration is a very important process for improving an imaging system performance. There has been a lot of previous works using linear camera modeling technique, where lens distortion is neglected and/or center of distortion is assumed to be known. Geometrical distortion of image intensifier, however, is very large and its center of distortion should be calculated. This paper presents a new calibration method to estimate the intensifier position and orientation, scale factor, distortion coefficient, magnification factor, and center of distortion using the least square method. We investigate the properties of the algorithm by computer simulation. Simulation results show that the parameters can be estimated accurately using the proposed algorithm.

  • PDF

PIV 애니메이션에 의한 가정용 냉장고 냉동실의 냉기 순환 해석 (Analysis on Cold Air Circulation of a Domestic Refrigerator Freezer by PIV Animation)

  • 김진영;양창조;김정환;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.686-691
    • /
    • 2000
  • Animation technique from the PIV database is particularly emphasized to give macroscopic and Quantitative description of complex flow fields. As an example, an experimental study was carried out investigate the fundamental (low characteristics of the freezer with the domestic refrigerator. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Image intensifier CCD camera to cope with illumination problem is arranged for the accurate PIV measurement of large flow field. As a results, continuous pictures of the spatial distribution of the instantaneous and time-mean velocity distribution are displayed in real-time sense.

  • PDF

PIV와 CFD에 의한 LNG선박의 Hood room 환기특성에 관한 연구 (A Study on Ventilation Characteristics of LNG Carrier Hood room by PIV and CFD)

  • 조대환;김동찬;김만응;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.673-679
    • /
    • 2000
  • LNG Carriers are currently known as sole commercial means of shipping natural gas on the sea. They are designed to proven dangerous explosion for shipping a lot of gas over long distance. In this study. In this study, a scaled model chamber was made to investigate ventilation characteristics of the hood room in LNG carrier. Experimental study was performed in model using visualization equipments with laser apparatus and image intensifier CCD camera gated by an AOM controller Twelve different kinds of measuring area were selected as experimental condition. Instant simultaneous velocity vectors at whole field were measured by using 2-D PIV system which software adopts two-frame grey-level cross correlation algorithm. To look into stagnation area of hood room for LNG carrier, a three-dimensional numerical simulation with standard ${\kappa}-{\varepsilon}$ model was carried out by using PHOENICS for three kinds of Reynolds number, $6.5{\times}10^3$, $9.7{\times}10^3\;and\;1.29{\times}10^4$, based on the cavity inlet velocity and cavity height. The flow pattern showed the large scale counter-clockwise forced-vortex rotated at center area, small eddies at each corner and stagnation area located at left-back upper side of model.

  • PDF

PIV에 의한 수중램제트추진의 기본특성에 관한 연구 (A Study on Fundamental Characteristics of Underwater Ram-Jet Propulsion by PIV)

  • 양창조;김춘식;최민선;김진구;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.36-42
    • /
    • 2000
  • A fundamental experimental study for an alternative proposal to super-speed craft propulsion system called underwater ram-jet propulsion by high pressure air ejection as driving force was investigated. For basic study of the effects of ram-jet propulsion performance, a simple underwater ram-jet flow field was established and PIV(Particle Image Velocimetry) method was adopted to analyse the jet-induced flow appearing at ram intake, mixing chamber and nozzle. Some flow dynamics relating to the high-speed ram-jet effect were discussed for the basic understanding of the its propulsion principle.

  • PDF

DUPIC 핵연료봉 봉단 용접부 건전성 확인을 위한 미세초점 X-선 투과시험에 관한 연구 (A Study on the Micro-Focus X-Ray Inspection for Confirming the Soundness of End Closure Weld of DUPIC Fuel Elements)

  • 김웅기;김수성;이정원;양명승
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.88-94
    • /
    • 2001
  • DUPIC (Direct use of spent PWR fuel in CANDU reactors) nuclear fuel is a CANDU fuel fabricated remotely from spent PWR fuel materials in a hot cell. The soundness of the end closure welds of nuclear fuel elements is an important factor for the safety and performance of nuclear fuel. To evaluate the soundness of the end closure welds of DUPIC fuel element, a precise X-ray inspection system is developed using a micro-focus X-ray generator with an image intensifier and a real time camera system. The fuel elements made of Zircaloy-4 and stainless steel by an Nd:YAG laser welding and a TIG welding aye inspected by the developed inspection system. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection process, and the irradiation test of DUPIC fuel elements has been successfully completed at the HANARO research reactor.

  • PDF

조사시험용 핵연료봉 용접부 비파괴검사에 관한 연구 (A Study on the Non-destructive Inspection for End Closure Welding of Nuclear Fuel Elements for the Irradiation Test)

  • 김웅기;김수성;이철용;이도연;이정원
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.302-304
    • /
    • 2004
  • Nuclear fuel elements containing dry recycling nuclear fuel pellets for the irradiation test in a reactor were remotely fabricated from spent PWR fuel materials in a hot cell. End closure welding as well as seal tube welding for thermal sensor of the elements was performed by Nd:YAG laser. The soundness of the end closure welds and seal tube welds for the elements were evaluated by a precise X-ray inspection system composed of a micro-focus X-ray generator with an image intensifier and a real time camera system. Then, helium leak test was performed for the elements. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection and helium leak test. The irradiation test for the fuel elements were successfully completed at the HANARO research reactor.

  • PDF

중간극 (20cm) 정극성 리-더의 진전 특성 (Characteristics of Positive Leader in Medium Gap)

  • 오철한;최영수;서욱창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.484-485
    • /
    • 1987
  • The characteristics of leader development in rod -to- plane air gap (20cm gap length) under positive impulse potentials have been studied by means of 2-photomultiplier technique and image intensifier camera. It was shown that the streamers radiate relatively short wavelength light (${\sim}340nm$) while the leaders radiate a plenty of long wave length light ($400{\sim}800nm$). It was also known that the streamers propagate very fast with a velocity of $6{\times}l0^7cm/sec$ but the leaders have average velocity of $5{\times}10^6cm/sec$ and they proceed gradually fast by step-wise development.

  • PDF

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF