• 제목/요약/키워드: Image Artifact

검색결과 390건 처리시간 0.025초

양자화 재생레벨 조정을 통한 DCT 영상 코오딩에서의 블록화 현상 감소 방법 (A Quantizer Reconstruction Level Control Method for Block Artifact Reduction in DCT Image Coding)

  • 김종훈;황찬식;심영석
    • 전자공학회논문지B
    • /
    • 제28B권5호
    • /
    • pp.318-326
    • /
    • 1991
  • A Quantizer reconstruction level control method for block artifact reduction in DCT image coding is described. In our scheme, quantizer reconstruction level control is obtained by adding quantization level step size to the optimum quantization level in the direction of reducing the block artifact by minimizing the mean square error(MSE) and error difference(EDF) distribution in boundary without the other additional bits. In simulation results, although the performance in terms of signal to noise ratio is degraded by a little amount, mean square of error difference at block boundary and mean square error having relation block artifact is greatly reduced. Subjective image qualities are improved compared with other block artifact reduction method such as postprocessing by filtering and trasform coding by block overlapping. But the addition calculations of 1-dimensional DCT become to be more necessary to coding process for determining the reconstruction level.

  • PDF

Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가 (Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact)

  • 이충환;윤인하;홍동기;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.85-95
    • /
    • 2010
  • 목 적: 두경부 환자의 CT simulation시 metal artifact가 발생하여 영상의 질 저하와 선량계산의 오차를 유발 할 수 있어 metal artifact를 줄이기 위한 gantry tilt scan의 유용성을 평가하고자 한다. 대상 및 방법: Metal artifact를 줄이기 위하여 $20^{\circ}$ gantry tilt scan하여 $0^{\circ}$로 재구성한 이미지를 획득하였다. AAPM CT performance Phantom을 이용하여 CT number를 비교 분석하고, 아크릴 팬텀을 이용하여 체적의 일치여부를 확인하였다. Metal artifact에 의한 영향을 평가하기 위해 Intensity volume Histogram (IVH)을 통한 CT number의 균질성 및 Dose Volume histogram (DVH)을 통한 선량평가를 시행하였다. 결 과: CT number와 체적의 비교에서는 차이가 0.5% 이하로 나타났다. IVH를 비교 분석결과 gantry tilt scan에서 artifact에 의한 영향이 감소되어 CT number의 균질도가 향상되고, DVH 비교결과는 양쪽 이하선의 0.2~6%의 평균선량 오차를 감소시켰다. 결 론: Head & Neck 방사선치료 시 metal artifact 때문에 체표윤곽의 구별이 어렵고 선량의 오차가 발생한다. Gantry tilt scan을 이용하면 정확한 조직의 묘사가 가능하고, CT number 균질도가 향상되어 선량의 오차를 줄일 수 있었다. Gantry tilt scan 은 Head & Neck 방사선치료 시 정확한 방사선치료에 매우 유용함을 확인하였다.

  • PDF

대수적 재구성 기법을 통한 링 아티팩트 조사 (Investigation of Ring Artifact Using Algebraic Reconstruction Technique)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.65-70
    • /
    • 2018
  • CT 장치는 물체 내부의 단면 영상 획득이 가능하기 때문에 여러 분야에 광범위하게 사용되고 있다. 단면 영상을 획득하는 여러 단계의 에러 요인들로 인해 다양한 아티팩트가 유발되고 있다. 장치에 의해 발생하는 링 아티팩트를 조사하였다. $512{\times}512$ 크기의 수치 팬텀을 구현하고 대수적 재구성 기법으로 링 아티팩트의 특성을 연구하였다. 프로그램은 Visual C++로 작성하였으며 720개의 투영 및 1,280개의 검출기 픽셀을 갖는 상황에서 구현하였다. 링 아티팩트는 검출기 픽셀의 검출 효율이 서로 달라서 발생한다는 것을 확인하였다. Ring Value 값이 증가할수록 Ring Intensity의 값도 증가하였고, 영상의 원점에 가까울수록 링 아티팩트가 강하게 나타났다. 단면 영상에서 링 아티팩트가 발생하는 위치를 파악하고 역으로 검출기 픽셀의 위치를 추적해 검출효율을 보정함으로써 링 아티팩트를 제거할 수 있을 것이다.

The Removal of Trembling Artifacts for FORMOSAT-2

  • Chang Li-Hsueh;Wu Shun-Chi;Cheng Hsin-Huei;Chen Nai-Yu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.142-145
    • /
    • 2005
  • Since the successful launch of FORMOSAT -2 satellite by National Space Organization of Taiwan in May 2004, the Remote Sensing Instrument (RSI) on- board the FORMOSAT -2 has continuously acquired images at one panchromatic and four multi-spectral bands (http://www.nspo.org.tw). In general, the RSI performs well and receives high quality images which proved to be very useful for various applications. However, some RSI panchromatic products exhibit obvious trembling artifact that must be removed. Preliminary study reveals that the trembling artifact is caused by the instability of the spacecraft attitude. Though the magnitude of this artifact is actually less than half of a pixel, it affects the applicability of panchromatic products. A procedure removing this artifact is therefore needed for providing image products of consistent quality. Due to the nature of trembling artifact, it is impossible to describe the trembling amount by employing an analytic model. Relied only on image itself, an algorithm determining trembling amount and removing accordingly the trembling artifact is proposed. The algorithm consists of 3 stages. First, a cross-correlation based scheme is used to measure the relative shift between adjacent scan lines. Follows, the trembling amount is estimated from the measured value. For this purpose, the Fourier transform is utilized to characterize random shifts in frequency domain. An adaptive estimation method is then applied to deduce the approximate trembling amount. In the subsequent stage, image re-sampling operation is applied to restore the trembling-free product. Experimental results show that by applying the proposed algorithm, the unpleasant trembling artifact is no longer evident.

  • PDF

CT영상에서 이미지 분할기법을 적용한 Blooming Artifact Reduction 비교 연구 (Comparison of Blooming Artifact Reduction Using Image Segmentation Method in CT Image)

  • 김정훈;박지은;박유진;지인희;이종민;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권6호
    • /
    • pp.295-301
    • /
    • 2017
  • In this study, We subtracted the calcification blooming artifact from MDCT images of coronary atherosclerosis patients and verified their accuracy and usefulness. We performed coronary artery calcification stenosis phantom and a program to subtract calcification blooming artifact by applying 8 different image segmentation method (Otsu, Sobel, Prewitt, Canny, DoG, Region Growing, Gaussian+K-mean clustering, Otsu+DoG). As a result, In the coronary artery calcification stenosis phantom with the lumen region 5 mm the calcification blooming artifact was subtracted in the application of the mixture of Gaussian filtering and K- Clustering algorithm, and the value was close to the actual calcification region. These results may help to accurately diagnose coronary artery calcification stenosis.

PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성 (Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT)

  • 함준철;강천구;조석원;반영각;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.71-75
    • /
    • 2013
  • 현재 PET/CT 검사에서 저선량 CT를 이용한 감쇠 보정을 사용하고 있다. 하지만 환자 호흡으로 인한 횡격막 부근의 저선량 CT 영상과 Emission 영상의 불일치로 감쇠 보정영상에서 Artifact가 발생하는 경우가 있다. 본 연구는 보정방법 중 CTAC Shift를 이용하여 환자의 호흡에 의한 Artifact의 감소를 연구했다. 2012년 3월부터 9월까지 PET/CT Discovery 600 (GE Healthcare, MI, USA) 장비를 이용하여 호흡에 의한 Artifact가 발생한 환자 30명을 대상으로 했다. Artifact가 발생한 환자는 횡격막 부분을 추가검사하였고, 전신 검사 시 Artifact가 발생한 영상을 CTAC Shift를 이용하여 보정했다. Artifact 발생 영상, 추가 검사영상, CTAC Shift 보정 영상의 육안적 평가는 핵의학 전문의 1명과 5년 이상 근무한 방사선사 4명에 의해 1-5점으로 나누어 평가했다. 또한 각 영상의 표준섭취화 계수를 ANOVA를 이용하여 비교했다. Artifact 발생 영상에 비해 추가 검사 영상과 CTAC Shift 보정 영상은 육안적 평가에서 상대적으로 높은 점수를 받았다. 추가 검사 영상과 CTAC Shift 보정 영상은 표준섭취화 계수의 ANOVA 결과, 높은 상관관계를 갖고 있으며, 유의한 차이를 보이지 않았다. PET/CT 검사 시 환자의 호흡에 의한 Artifact가 발생 할 경우 추가 검사로 인한 검사 시간이 증가하여 환자의 불편 뿐 아니라 피폭도 증가한다. 하지만 추가 검사 없이 CTAC Shift를 이용하여 보정된 영상을 획득한다면 불필요한 피폭 및 추가 검사도 감소하며, 정확한 진단에 도움을 줄 것으로 사료된다.

  • PDF

영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구 (Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker)

  • 김종민;김대섭;백금문;강태영;홍동기;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권1호
    • /
    • pp.1-10
    • /
    • 2010
  • 목 적: Fiducial marker를 이용하여 움직이는 장기인 간암의 영상유도 방사선 치료 시 fiducial marker에서 발생하는 artifact의 영향에 대하여 알아보고자 한다. 대상 및 방법: 영상 유도 시스템과 CT simulator를 사용하여 고정된 fiducial marker의 artifact 크기 측정, 움직이는 fiducial marker 궤적의 길이 측정과 2차원 정합과 3차원 정합을 각각 시행하였으며, 이때 couch의 좌표 이동 값을 분석하였다. 결 과: 고정된 3.00 mm 크기의 fiducial marker artifact 크기 측정 결과 기준 CT 슬라이스 두께 1.25, 2.50, 5.00, 10.00 mm에서 CT 4.90, 8.10, 12.90, 19.70 mm, 온 보드 영상장치 5.60, 10.60, 14.70, 29.40 mm로 측정되었고, 40.00 mm로 움직이는 fiducial marker 궤적의 길이를 측정한 결과 CT 42.00, 43.10, 46.50 mm, 온 보드 영상장치 43.40, 46.0, 49.30 mm로 측정되었다. 2차원 정합과 3차원 정합 사이에 1.00, 2.00, 8.00 mm의 좌표 이동이 발생하였다. 결 론: Fiducial marker를 이용하여 영상 유도 방사선 치료를 시행 할 때 fiducial marker에서 발생하는 artifact를 고려하여 slice thickness를 2.50 mm 이하로 설정하는 것이 치료 오차를 최소화 할 수 있는 방법이라 생각한다.

  • PDF

Simple image artifact removal technique for more accurate iris diagnosis

  • Kim, Jeong-lae;Kim, Soon Bae;Jung, Hae Ri;Lee, Woo-cheol;Jeong, Hyun-Woo
    • International journal of advanced smart convergence
    • /
    • 제7권4호
    • /
    • pp.169-173
    • /
    • 2018
  • Iris diagnosis based on the color and texture information is one of a novel approach which can represent the current state of a certain organ inside body or the health condition of a person. In analysis of the iris images, there are critical image artifacts which can prevent of use interpretation of the iris textures on images. Here, we developed the iris diagnosis system based on a hand-held typed imaging probe which consists of a single camera sensor module with 8M pixels, two pairs of 400~700 nm LED, and a guide beam. Two original images with different light noise pattern were successively acquired in turns, and the light noise-free image was finally reconstructed and demonstrated by the proposed artifact removal approach.

자기공명영상 왜곡에서 마스카라와 아이섀도의 영향 (Effects of the mascara and eye shadow on theMR image distortion)

  • 이현용;신운재;박병래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권1호
    • /
    • pp.25-32
    • /
    • 2005
  • 목 적 : 마스카라와 아이섀도가 자기공명영상 획득시 artifact를 어느 정도 일으키는가를 알아보고, pulse sequence에 따른 영상 왜곡의 차이를 비교하고자 한다. 대상 및 방법 : 실제 국내 여성들이 많이 사용 중인 3개 제조사의 제품 중 마스카라(M1, M2, M3)와 아이섀도(E1, E2, E3)를 선별하여 사용하였다. 자체 제작한 내경이 4 cm, 코일의 길이가 8 cm인 Tx/Rx 겸용의 quadrature type의 안장 코일을 사용하였다. 실험 1에서는 마스카라를 실험 2에서는 아이섀도를 실험 3에서는 마스카라에 아이섀도를 덧바른 후 영상을 획득하였다. Pulse sequence는 FSE(fast spin echo), SE(spin echo), GE(gradient echo)기법을 적용하였으며, 나타난 artifacts는 axial상에서 폭, sagittal상에서 길이를 각각 측정하였다. 각 sequence별로 측정된 영상왜곡 정도를 정량적 및 정성적으로 분석하였다. 결 과 : 마스카라와 아이섀도가 자기공명영상에서 부분적으로 artifact가 발생되어 영상왜곡을 유발하였다. Pulse sequence에 따른 artifact의 유발 정도도 다소 차이가 나타났다. 마스카라에 아이섀도를 덧바른 실험 3에서는 axial상에서 GE sequence에서 16.73 mm, SE에서 6.64 mm, FSE에서 6.19 mm의 폭으로 GE 기법에서 가장 많이 유발되었으며, SE, FSE 기법 순으로 높게 나타났다. sagittal상에서 GE sequence에서 22.84 mm, SE에서 18.15 mm, SE에서 17.81 mm의 길이로 GE 기법에서 가장 많이 유발되었으며, SE, FSE 기법 순으로 낮게 나타났다. 결 론 : 마스카라와 아이섀도로 화장한 여성의 뇌 및 안구 영상검사시 artifact가 영상진단에 영향을 미치는 것으로 판단된다. 뇌 및 안구 T2 강조영상을 얻고자 하는 경우는 pulse sequence를 GE보다 FSE 기법을 사용하는 것이 적합한 것으로 사료된다.

  • PDF

적응 양자화 제한 집합으로의 투영을 이용한 블록 현상 제거 (Blocking-Artifact Reduction using Projection onto Adaptive Quantization Constraint Set)

  • 정연식;김인겸
    • 대한전자공학회논문지SP
    • /
    • 제40권1호
    • /
    • pp.79-86
    • /
    • 2003
  • 본 논문에서는 블록 변화된 영상의 블록 환상을 제거하기 위해 POCS(Projection Onto Convex Set) 이론을 바탕으로 하는 적응 양자화 체한 집합을 제안한다. POCS 이론을 바탕으로 하는 블록 현상 제기 기법은 크게 부드러움 제한 집합과 양자화 제한 집합으로의 반복적인 투영을 동해 이루어진다. 기존의 양자화 제한 집합은 원 영상의 데이터가 가질 수 있는 최대 구간을 지정해 주므로 반복이 계속될수록 over-blurring 현상이 심화된다. 제안한 양자화 제한 집합은 이산 여현 변환(DCT) 계수의 특성에 파라 적응적으로 제한 구간을 조절하므로 복호화된 영상의 선명도를 유지하면서 동시에 효과적으로 블록 현상을 제거할 수 있다. 기존의 후처리 알고리즘의 양자화 제한 집합을 제안한 적응적 양자화 제한 집합으로 대체하여 실험을 수행한 결과 적은 반복 횟수로도 수령에 도달하였고 후처리 된 영상 역시 선명도를 유지하면서 블록 현상이 효과적으로 제거되었음을 알 수 있었다.