• Title/Summary/Keyword: Illumination variance

Search Result 32, Processing Time 0.018 seconds

Estimation of Illuminant Chromaticity by Equivalent Distance Reference Illumination Map and Color Correlation (균등거리 기준 조명 맵과 색 상관성을 이용한 조명 색도 추정)

  • Kim Jeong Yeop
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.267-274
    • /
    • 2023
  • In this paper, a method for estimating the illuminant chromaticity of a scene for an input image is proposed. The illuminant chromaticity is estimated using the illuminant reference region. The conventional method uses a certain number of reference lighting information. By comparing the chromaticity distribution of pixels from the input image with the chromaticity set prepared in advance for the reference illuminant, the reference illuminant with the largest overlapping area is regarded as the scene illuminant for the corresponding input image. In the process of calculating the overlapping area, the weights for each reference light were applied in the form of a Gaussian distribution, but a clear standard for the variance value could not be presented. The proposed method extracts an independent reference chromaticity region from a given reference illuminant, calculates the characteristic values in the r-g chromaticity plane of the RGB color coordinate system for all pixels of the input image, and then calculates the independent chromaticity region and features from the input image. The similarity is evaluated and the illuminant with the highest similarity was estimated as the illuminant chromaticity component of the image. The performance of the proposed method was evaluated using the database image and showed an average of about 60% improvement compared to the conventional basic method and showed an improvement performance of around 53% compared to the conventional Gaussian weight of 0.1.

Decomposition Characteristics of Fungicides(Benomyl) using a Design of Experiment(DOE) in an E-beam Process and Acute Toxicity Assessment (전자빔 공정에서 실험계획법을 이용한 살균제 Benomyl의 제거특성 및 독성평가)

  • Yu, Seung-Ho;Cho, Il-Hyoung;Chang, Soon-Woong;Lee, Si-Jin;Chun, Suk-Young;Kim, Han-Lae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.955-960
    • /
    • 2008
  • We investigated and estimated at the characteristics of decomposition and mineralization of benomyl using a design of experiment(DOE) based on the general factorial design in an E-beam process, and also the main factors(variables) with benomyl concentration(X$_1$) and E-beam irradiation(X$_2$) which consisted of 5 levels in each factor was set up to estimate the prediction model and the optimization conditions. At frist, the benomyl in all treatment combinations except 17 and 18 trials was almost degraded and the difference in the decomposition of benomyl in the 3 blocks was not significant(p > 0.05, one-way ANOVA). However, the % of benomyl mineralization was 46%(block 1), 36.7%(block 2) and 22%(block 3) and showed the significant difference of the % that between each block(p < 0.05). The linear regression equations of benomyl mineralization in each block were also estimated as followed; block 1(Y$_1$ = 0.024X$_1$ + 34.1(R$^2$ = 0.929)), block 2(Y$_2$ = 0.026X$_2$ + 23.1(R$^2$ = 0.976)) and block 3(Y$_3$ = 0.034X$_3$ + 6.2(R$^2$ = 0.98)). The normality of benomyl mineralization obtained from Anderson-Darling test in all treatment conditions was satisfied(p > 0.05). The results of prediction model and optimization point using the canonical analysis in order to obtain the optimal operation conditions were Y = 39.96 - 9.36X$_1$ + 0.03X$_2$ - 10.67X$_1{^2}$ - 0.001X$_2{^2}$ + 0.011X$_1$X$_2$(R$^2$ = 96.3%, Adjusted R$^2$ = 94.8%) and 57.3% at 0.55 mg/L and 950 Gy, respectively. A Microtox test using V. fischeri showed that the toxicity, expressed as the inhibition(%), was reduced almost completely after an E-beam irradiation, whereas the inhibition(%) for 0.5 mg/L, 1 mg/L and 1.5 mg/L was 10.25%, 20.14% and 26.2% in the initial reactions in the absence of an E-beam illumination.