• Title/Summary/Keyword: Illumination energy

Search Result 357, Processing Time 0.021 seconds

A Study on Savings Analysis of Light Dimming Control System Using the Daylight based on Photovoltaic Power Generation (태양광발전 기반의 주광을 활용한 조명제어 시스템의 에너지 절감량 분석 연구)

  • Ham, Won-Tae;Jang, Cheol-Yong;Jeong, Hak-Guen
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.11-21
    • /
    • 2012
  • In the normal office building, the energy consumption to maintain the reasonable intensity of illumination for the work by using the artificial illumination occupies 30% or greater of the whole building electric energy consumption. If the dependability of the artificial illumination is dropt by positively using the natural lighting from the outside, the large amount of electrical energy can be saved, in addition the more nice visual environment for work can be created. Daylight is lighting source that most closely match visual response of the human, because sunlight and skylight achieve the harmony. For this reason, the daylight of small amount than amount of the artificial lighting source also can give the same effect in work activities of human. In addition, if there is daylight at the window of the building, the energy can be saved by controlling the artificial lighting. In this paper, in the building using the photovoltaic power generation analyze the correlation between the amount of energy generated by photovoltaic and indoor illumination and this was proved through the simulation with Relux 2010. In addition, the amount of daylight inflow in the room and distribution was drawn by the equation and the ratio for the sectional dimming control of each lighting equipment was predicted and the energy saving amount according to this was calculated. As a result, the indoor illumination was satisfied with recommended illumination value of the office and consumption power could be reduced approximately with 20~70%.

A Study to Suggest a Method to Evaluate Light Environment Energy Performance based on Actual Residence Environments (실거주환경 기반 빛환경 에너지 성능평가 방법 제안 연구)

  • Gim, Sang-Hoon;Lee, Heang-Woo;Kim, Yong-Seong
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.33-39
    • /
    • 2013
  • As lighting energy consumption in buildings occupies high ratio, technical researches to solve it have been constantly carried out. However, basic studies on light environment performance evaluation is actually deficient and only at a level of a simple illumination monitoring. Thus, this study has suggest a light environment energy performance evaluation based on actual residence environments to allow setting lighting interoperation and user required illumination. Conclusions from the study are as follows: 1) As the performance evaluation suggested by this study has not only derived lighting energy usage as well as monitored simple indoor illumination distribution, it is quantitative and allows derivation of visual results. 2) The performance evaluation suggested by this study allows inputs of user required illumination through the performance evaluation server, which is able to support for performance evaluations for various works and users. 3) This study has verified validity of the performance evaluation method by analyzing results of lighting energy reduction by executing performance evaluation on changes of light shelf that is a natural lighting system through the suggested performance evaluation method. This study is significant from a viewpoint that it has suggested a quantitative performance evaluation method on the basis of actual residence environments. Those researches concerned on the energy performance evaluation should be constantly progressed from an aspect that they are another solution of the energy problems.

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

A Development of a LED Stand Using Illuminance Sensor for Efficient Energy Saving (효율적인 에너지 절감을 위한 센서 LED 스탠드 개발)

  • Chun, Sung-Yong;Shin, Ji-Yea;Park, Shin-Won;Yi, Hwa-Cho;Lee, Chan-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, we present a new lighting control method considering ambient light in addition to the required lighting illumination for efficient energy saving of a LED stand. We estimate accurate environmental illuminance using a cheap illuminance sensor by modeling measured- and actual-illuminance using quadratic polynomial approximation. The relation between PWM(Pulse Width Modulation) duty ratio and illuminance intensity is modeled by a linear model. Illumination of the LED stand is controlled by estimating the difference of required illumination and the estimated ambient illumination. The developed LED stand has reduced electric energy consumption compared with a conventional manually controlled LED stand with the same lighting source. In addition, human subject evaluation shows that the LED stand, which is applied the proposed method, is more satisfactory than conventional ones since the proposed automatic controlled illumination produce more accurately required lighting and it is convenient.

A Study on the development of climatic data for the daylighting design (자연채광 설계용 기상자료의 개발에 관한 연구)

  • Yang, In-Ho;Kim, Kwang-Woo;Kim, Mun-Han
    • Solar Energy
    • /
    • v.11 no.1
    • /
    • pp.3-15
    • /
    • 1991
  • In this study global radiation and global illumination are directly measured and diffuse radiation and diffuse illumination measured utilizing semi-circular shadow ring. By analyzing measured radiation data, clear and overcast sky are classified according to the sky classification method used in Mantes, France. Measured illumination data are analyzed and 1) Clear sky illumination on a horizontal surface as a function of solar altitude. 2) Overcast sky illumination on a horizontal surface as a function of solar altitude, 3) Monthly variation of illumination. 4) Cumulative percentage of illumination, 5) Daylight intensity as a function of hours in a typical day, 6) Average number hours per day of illumination above 10 and 20klx are presented as a climatic data for daylighting design for Seoul, Korea.

  • PDF

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

Energy Consumptions and Daylight Illumination levels of a Multi-beded Patient Room according to the Window Shapes and Shading (창의 형태 및 차양 계획에 따른 다인 병실의 에너지소비량과 주광조도의 평가 및 분석)

  • Choi, Changdae;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.3
    • /
    • pp.29-39
    • /
    • 2012
  • Window and shading designs have a great influence on energy consumption and daylighting in buildings. As far as energy is concerned, small window area is advantageous. But it is not good to the patient healing in hospital. So it is important to find out the optimum window shape which is favorable for both energy consumption and patient healing. In this study, annual energy consumption and daylight illumination levels were analyzed according to the window shapes and shading devices for a multi-beded patient room in hospitals. The simulations were conducted for 19 different cases by COMFEN 4.0 computer simulation program. The results of this paper are as follows. First, window to wall area ratio and shading devices have great influences on annual energy consumption. But it is a problem in that they decrease significantly daylight level in bed room. Second, considering the same energy consumption, reducing the width of window rather than the hight of window is desirable for the secure of daylight level. Third, increase of the number of horizontal shade is not desirable in south face of the building for the energy consumption and daylight level. Fourth, sun shade is not necessary in north face of the building for the energy consumption and daylight level.

Output Power Characteristics of CPV Solar Cell due to Non-uniform Illumination (고집광 태양전지의 비균등 조사에 의한 출력특성)

  • Shin, Goo-Hwan;Ryu, Kwang-Sun;Cha, Won-Ho;Myung, Noh-Hoon;Kim, Young-Sik;Kang, Gi-Hwaw
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.269-274
    • /
    • 2011
  • A solar cell is primary parts to produce electrical energy from the Sun. And, we can utilize those solar cells as a power generation system in home, factory, and so on. In order to make proper power, the solar cells are configured in series and parallel lay down. In condition of uniform illumination, the solar array will produce an enough power by photovoltaic effects from the solar cells. In case of non-uniform illumination on the solar cells, the power will be dramatically decreased compared to design. Fortunately, there were so many research outputs regarding the illumination effects on solar array. In this work, we tried to find out the non-uniform effects on unit CPV solar cell, because there were no research outputs for unit CPV solar cell considering illumination. The CPV solar cell was used in CPV system to make a power by the Sun. We chosen the triple junction solar cell of GaAsInP2Ge for simulation, which has a 30 % of conversion efficiency. By simulation, we obtained the output performance of CPV solar cells in condition of various illumination by using Hamming Window function. Its performance was degraded by 10 % to 50 % depending illumination conditions.

  • PDF

A Study on the Suggestion of a Lighting Control System Applying General Illumination and Technology of User and Location Awareness (전반조명 기반 사용자 및 위치인식기술 적용 조명제어 시스템 제안 연구)

  • Park, Juil;Lee, Haengwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.527-536
    • /
    • 2015
  • Studies for the reduction of lighting energy have been done using technologies such as user and location awareness. However, the focus of current research on location-based lighting control has been on energy reduction, which can lead to other issues including an imbalance in indoor illumination. This study proposes a lighting control system applying general illumination and technology for user and location awareness. The proposed lighting control system reduced lighting energy by 72.1%, 66.5% and 62.3% for 1, 2 and 3 users, respectively, compared to the On/Off lighting control system. This lighting control system causes an increase in lighting energy of 35.8% and 10.9% for 1 and 2 users compared to the lighting control system with user and location awareness, while a reduction of 9.4% was seen for 3 users. This means that the proposed system provides more effective energy reduction for a room with multiple occupants as it is based on the general lighting control scheme. The lighting control system applying general illumination and technology of user and location awareness improved the uniformity factor by 32.0%, 39.4% and 33.4% for 1, 2 and 3 users, respectively.