• 제목/요약/키워드: Illuminance difference

검색결과 57건 처리시간 0.023초

천공구분에 따른 서울지역 일사의 발광효율 측정 및 예측모델과의 비교 연구 (Comparison of Measurement and Calculation Model of Solar Luminous Efficacy for All Sky Conditions in Seoul)

  • 윤갑천;윤경;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제31권6호
    • /
    • pp.86-94
    • /
    • 2011
  • For accurate dayligh tsimulation, accurate exterior illuminance is necessary. But, Korea Meteorological Agency provides only the solar irradiance data. Thus, there is a need for the research on luminous efficacy. In this study, global horizontal irradiance, diffuse horizontal irradiance, global horizontal illuminance, and diffuse horizontal illuminance were measured to calculate the luminous efficacy in SEOUL. And, we evaluated the applicability of the Perez's model by comparing the measured data and calculated data. As a result, measured global luminous efficacy is 126(110~129)lm/W and diffuse luminous efficacy is 127(115~133)lm/W in Seoul. Perez's model was relatively accurate with 5% difference in the diffuse luminous efficacy. But, it can be predicted about 15% lower in the global luminous efficacy.

조명원리를 기반으로 한 성당조도의 적정수준 적용분석 연구 (A Study on the application of appropriate level of illuminance to the Cathedral based on lighting principles)

  • 반상철
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.685-696
    • /
    • 2017
  • 성당의 공간이미지를 조성함에 있어, 시각을 통해 심성을 변화시키는 가장 중요한 요인은 빛이라고 할 수 있다. 그리고 공간의 깊이는 빛에 의한 음영에 의해 만들어진다. 미사와 같은 종교적 행사가 행해지는 장소에 있어서 음영에 의한 깊이의 변화와 위계설정은 집중도와 신비로움 또는 성스러움의 분위기를 확보하는 데에 중요한 계획조건이 된다고 할 수 있다. 따라서 빛이 가진 종교적 의미와 인간 감성에 미치는 영향은 매우 크다고 할 수 있으며, 이에 본 연구에서는 성당의 예배공간 조명계획에 대한 요소 중 '조도'를 그 중요요소로 보았다. 조도는 시각적 환경조성에서 미묘한 공간구성상의 차이를 통해 대상과 공간의 형태, 명료함을 부여함으로써 표현된다. 조명을 통해 공간분위기를 적정한 수준에서 관리하게 되고, 공간의 존재를 확인함에 조도의 역할은 필수적이라고 할 수 있을 것이다. 이에 따라, 관련 기준을 종합 분석하여 조도의 기준과 범위를 설정하고, 현대적인 디자인 적용이 시작되었다고 할 수 있는 80년대 이후 서울 강남지역에 건립된 성당들을 대상으로 조도와 관련된 요소들을 분석하고 각 성당의 전례공간과 회중석의 조도를 측정하여 이를 비교분석함으로써 적정수준의 적용여부를 검토확인하고 이를 추후 계획지침으로 활용하도록 제안하고자 하였다.

조도와 글자 크기에 따른 가시거리 측정과 예상 (Measurement and Forecast of the Visibility Range according to Illuminance and the Character Sizes)

  • 김태현
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.425-429
    • /
    • 2014
  • 가시거리는 무엇인지 정확히 보이는 거리로 정의되며 이는 조도, 글자 크기와 시력 등에 따라 달라진다. 본 논문에서는 4가지 글자 크기와 3가지 조도에 대해서 약 120명의 학생들을 대상으로 교실에서 가시거리를 측정하였다. 측정하지 않은 조도에 대한 가시거리를 예상하기 위해서 최소 제곱 근사 이론을 적용하여 조도가 독립변수이고 가시거리가 종속변수인 함수를 만들었다. 조도가 많이 변해도 가시거리는 조금 밖에 변하지 않으므로 상용로그함수를 이용하여 글자 크기 4가지 각각에 대해서 함수를 만들었다. 만들어진 함수의 값과 측정값과의 오차가 매우 적으므로 함수가 잘 만들어졌음을 보였다.

학습공간에서의 독서 행위 시 조명환경에 따른 이미지평가 연구 (A Study on Image Evaluation consequent on Lighting Environment in time of reading in Learning Space)

  • 이진숙;박지영;서은지
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.1-9
    • /
    • 2015
  • The aim of this study is to deduce color temperature and illuminance by conducting the preference & affective evaluation consequent on illuminance change of ambient light in case of the lighting method of ambient light mixed with task light in time of reading which is visual work action among the action in learning space. As a result of the prior survey on preferred lighting method in time of the act of reading targeting 20 experts before doing evaluation, the method of lighting mixed with ambient light and task light was found to be the highest. Such a result is analyzed to be attributable to the fact that the less the difference in illuminance of nearby space and work surface because of the mixed method of lighting, the less the glare, which makes a reader feels easy and concentrate on reading. On the basis of descriptive statistics of evaluation results and impact analysis by category, this study recommends the application of combinations of ambient light illuminance ranging from 40lx to 100lx with color temperature of 5500~6000K in case of the method of lighting mixed with general light and task light.

도심 내 야간의 조도와 봄철 수목 개화 및 잎 생장 간 상관관계 - 서울 잠실역에서 올림픽공원 구간을 대상으로 - (Correlation between the Illuminance and the Flowering and Leaf Growth of Trees at Night - In Case of Downtown from Jamsil Station to Olympic Park, Seoul -)

  • 한봉호;김종엽;곽정인;최태영
    • 한국환경생태학회지
    • /
    • 제29권3호
    • /
    • pp.441-453
    • /
    • 2015
  • 본 연구에서는 서울 도심 내 야간 인공 조명의 조도에 따라 수목 개화율과 잎 생장률이 차이가 있는 지를 규명하기 위한 사례 연구로 수행되었다. 조도는 총 26개소에서 78개 지점에서 측정하였고, 조도와 토지이용현황을 고려하여 3개 그룹으로 구분하였으며, 그룹 A(조사구 1~7)의 조도 범위는 4.90~112.50 lx, 그룹 B(조사구 8~18)의 조도 범위는 0.45~42.40 lx, 그룹 C(조사구 19~26)의 조도 범위는 0.28~22.10 lx이었다. 조도 차이 일원배치 분산분석 결과 그룹 A, B, C로 분류되었다. 수목 개화율은 왕벚나무와 철쭉류 각 30개체, 수목 잎 생장률은 느티나무, 은행나무, 단풍나무 각 30개체를 선정하여 조사하였다. 수종별 일원배치 분산분석 결과 연구대상 수목 중에서 개화율은 철쭉류, 잎 생장률은 단풍나무가 세 개의 그룹으로 분리되어 상대적으로 조도 차이에 따른 수목 영향 지표종으로서 유용한 것으로 판단되었다. 그룹별 평균 조도와 수목의 개화율 및 잎 생장률 간 상관관계 분석결과 유의성이 인정되어 조도가 높을수록 수목의 개화 및 잎 생장이 빨라지는 경향이 있는 것으로 판단되었다. 향후에는 야간 조명의 빛공해 수준별로 수목에 어느 정도 영향을 미치고 있는 지에 대한 보다 구체적인 연구가 이루어져야 할 것이다.

동.서양인의 주거공간 행태에 따른 LED조명환경 (A Study on LED Lighting Environment of Asians and Westerners by Behaviors in Residential Space)

  • 양정순
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.16-27
    • /
    • 2013
  • This study describes the difference of lighting directing techniques of between asian and westerner in the residential space, and presents the LED lighting environment according to the residents' behaviors. This study was conducted with Koreans, European and North Americans, and the space range was limited to the living room where the various activities occur. The data of the desired LED lighting environment is drawn through lighting technique, illumination color temperature and illuminance variation of LED in living room, and the detailed study results are as follows ; First, the lighting in living space should be made with considering the various behaviors because the expected level according to consideration or not of behavior makes much difference. Second, the comfortably feeling LED lighting environments that are lighting technique, illumination color temperature and illuminance variation, are different between Koreans and North Americans, but Koreans and European feel comfortable under the similar LED lighting environments. Third, the data for the comfortable LED lighting environments is established according to the various residents' behaviors, which are watching TV, reading, studying, relaxing, chatting, entertaining guests. And then, the established LED lighting environments are analyzed with characteristic of behavior and classified according to lighting technique, illumination color temperature and illuminance variation for understanding their characteristic Few studies have been conducted to find out difference of the comfortably feeling LED lighting environment between asians and westerners. Therefore, in this study, it has a great significance to present the difference of the LED lighting environments that asians and westerners feel comfortable in living space, and to draw the characteristic of the expected lighting environment according to residents' behaviors.

무대방송 조명 등기구에서의 조도 실측과 시뮬레이션 조도 측정 비교 연구 (A Study on the Comparison of Illuminance Simulations and Measured Values of Compare a Stage and Broadcasting Lighting Fixture)

  • 이장원;임지원;한석우
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.145-152
    • /
    • 2011
  • 무대방송 프레즈널 조명기와 플라노 컨벡스 조명기의 측정값과 시뮬레이션 측정값의 조도를 측정하기 위하여 대전보건대학 스튜디오 안에서 전동바턴 시스템의 조명 등기구를 설치하였다. 프레즈널 조명기와 플라노 컨벡스 조명기의 조도 시뮬레이션 값과 측정값을 비교하여 조도 오차가 얼마나 생기는지에 대하여 비교하였다. 비교한 결과 시뮬레이션 프레즈널 조명기와 플라노 컨벡스 조명기의 측정값은 39.7~250.6Lux 차이가 있다. 그리고 프레즈널 조명기와 플라노 컨벡스 조명기의 실측값의 조도값의 차이는 92.84~157.35Lux 차이가 있다.

도로조명 설계에 있어서 휘도-조도 환산계수 적용에 관한 검토 (A study on the luminance-to-illuminance conversion factor in the roadway lighting design)

  • 주윤석;이동호;여인선;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.151-155
    • /
    • 1998
  • In this paper it is examined the validity of luminance-to-illuminance conversion factor in the roadway lighting design. Luminance and illuminance distribution patterns were measured to yield the calculated conversion factor on the newly-constructed highway, and this value was compared to the conversion factor commonly used. We found that some discrepancy might exist between them due to difference in the values between the luminance yield factor and the coefficient of utilization. Therefore this fact must be fully understood in the roadway lighting design process.

  • PDF

미술관의 조명환경 변화에 따른 시각적 반응 및 피로감각 변화분석 (Influence of Luminous Environments on Visual Responses and Fatigue Sensation in Art Galleries)

  • 박윤혜;김수영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.61-72
    • /
    • 2011
  • The influences of luminous environment on visual responses and fatigue sensation in art galleries were examined in this study. Field measurements and survey were performed in three galleries under various illuminance and luminous conditions. Result implies that vertical illuminance on art paintings needed to be somewhere between 200 lx and 300 lx to avoid visual discomfort. The vertical illuminance difference between consecutive paintings should not exceed 100 lx to keep visually comfortable environment. Visual comfort sensations were related to glare, visual stimulus, reflection from paintings, illuminance variation, and the sensation that subjects can clearly see the paintings. The sensation of fatigue was significantly influenced by the changes of luminous element that caused visual stimulus and discomfort. The sensation of eye fatigue among physical fatigue was primarily influenced by the glare, visual stimulus and comfort. The psychological fatigue was also influenced by eye fatigue, visual comfort, brightness and satisfaction with color of light.

Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정 (Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe)

  • 김지민;한아영;이하영;이소라;권대철
    • 한국자기학회지
    • /
    • 제26권5호
    • /
    • pp.168-172
    • /
    • 2016
  • MRI 검사실의 최적환경을 목적으로 검사실 및 모니터의 휘도와 조도를 측정하였다. 대학병원(n = 6)의 MRI(n = 10)에서 휘도와 조도를 Unfors Xi Light Probe(Unfors Instruments AB, Billdal, Sweden)를 이용하여 측정하였다. 휘도는 black level과 white level을 조도는 모니터의 측면의 중앙에서 3회 반복하여 평균과 표준편차를 구하여 t-test를 이용하여 유의성 검정의 통계적 처리를 하였다. 모니터 휘도는 black level에서 평균 $1.78cd/m^2$, 표준편차 $0.85cd/m^2$이었고, white level에서는 평균 $43.58cd/m^2$, 표준편차 $13.19cd/m^2$로 측정되었다. MRI 검사실 조도는 최저값 30.5 lux, 최대값 601.3 lux, 평균 177.86 lux로 측정되었고, 휘도와 조도는 통계학적으로 유의한 차이가 있다(p < .05). MRI 모니터 및 검사실 휘도와 조도의 권고 기준을 참고하여 최적인 환경을 조성하도록 한다.