• Title/Summary/Keyword: Ignition Test

Search Result 468, Processing Time 0.025 seconds

Study on the effect of Jet Fuel alteration on Turbine Engine Performances through Turbine Engine Test (터빈엔진시험을 통한 제트연료 변경에 따른 엔진성능 변화 연구)

  • Kim, You-Il;Min, Seong-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.410-415
    • /
    • 2010
  • The engine ground and altitude tests were carried out to investigate the effect of jet fuel alteration on the performance of a small turbojet engine. JP-S was supplied 8% higher than JP-8 by fuel metering system at the same command. The employment of JP-S showed the similar starting characteristic to that of JP-8, however, difference in the ignition time and acceleration rate of engine speed due to the difference of fuel flow rate by fuel metering system was observed. In spite of jet fuel alteration, the test results yield the similar Steady-State engine performance in Net thrust, Air flow, Exhaust Gas Temperature, etc. On the other hand, the Fuel consumption of JP-S increased by 5 % compared with that of JP-8. In point of Specific Fuel Consumption (SFC), SFC of JP-S was approximately 1.1~2.6 %, 5 % higher than that of JP-8 in ground and altitude tests respectively at the same thrust.

  • PDF

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

Experimental Study on the Effects of Combustion Products on the Human Body and Suggestion of Law Revision (흡음재의 연소 생성물이 인체에 미치는 영향에 대한 실험적 연구 및 법률 개정 제언)

  • Kang, Jung Ki;Choi, Don Mook
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.28-34
    • /
    • 2019
  • Regardless of the ignition source, the main factors affecting the spread of flames to the human body are combustibles. The sound absorption material, which is the finishing material used in music institutes and karaoke rooms, consists of polyurethane that generates a large amount of toxic gas with a high amount of combustion gases during a fire. Still, the current law does not require the use of impregnated finishing materials for tutoring services with less than 100 users. In this study, the rate of flame diffusion was measured using the MultiRaelite composite gas measuring instrument (target substance VOC, HCHO, SO2, CO2, CO, HCN, and NO2) for the collection of sound-absorbing materials installed in the actual music academy. The results showed that the toxic gas found in this experiment exceeded the allowable concentration of TWA (Time Weighted Average) and STEL (Short Term Exposure Limit). In addition, a comparative combustion test of the general sound absorber and non-combustion sound absorbing materials on the market showed wide differences in ignition and diffusion. Therefore, based on the results of the experiment, private institutes with less than 100 users should be mandated to use non-combustion sound absorbing materials.

Experimental Study on the Measurement of Fire Behavior and Heat Release Rate in Building Compartment Space - Focus on Full Scale Fire Test of the Bed Mattress - (건축물 구획공간에 따른 화재성상 및 열방출율 측정에 관한 실험적 연구 - 실물규모 침대 매트리스 화재시험 중심으로 -)

  • Seo, Bo-Youl;Jang, Woo-Bin;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.28-33
    • /
    • 2018
  • To measure the full scale fire test and heat release rate of bed mattresses according to the building compartment space, a fire test was performed using the Standard test method to determine the heat release rate of mattresses and mattress sets (KS F ISO 12949: 2011). Both test locations showed similar fire growth until approximately 3 minutes after burner ignition. After 3 minutes, the heat release rate in the test room was higher than the open calorimeter. For bed mattresses (SS), the maximum heat release rate in the open calorimeter was 735 kW and the maximum heat release rate in the test room was 992 kW. For bed mattresses (Q), the heat release rate in the test room increased more rapidly than the open calorimeter. The maximum heat release rate in the open calorimeter was 1,087 kW (346 s) and the maximum heat release rate in the test room was 2,127 kW (287 s). The difference between the maximum heat release rate and the measurement time according to the test location was confirmed.

Accuracy and applicable range of a reconstruction technique for hybrid rockets

  • Nagata, Harunori;Nakayama, Hisahiro;Watanabe, Mikio;Wakita, Masashi;Totani, Tsuyoshi
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.3
    • /
    • pp.273-289
    • /
    • 2014
  • Accuracy of a reconstruction technique assuming a constant characteristic exhaust velocity ($c^*$) efficiency for reducing hybrid rocket firing test data was examined experimentally. To avoid the difficulty arising from a number of complex chemical equilibrium calculations, a simple approximate expression of theoretical $c^*$ as a function of the oxidizer to fuel ratio (${\xi}$) and the chamber pressure was developed. A series of static firing tests with the same test conditions except burning duration revealed that the error in the calculated fuel consumption decreases with increasing firing duration, showing that the error mainly comes from the ignition and shutdown transients. The present reconstruction technique obtains ${\xi}$ by solving an equation between theoretical and experimental $c^*$ values. A difficulty arises when multiple solutions of ${\xi}$ exists. In the PMMA-LOX combination, a ${\xi}$ range of 0.6 to 1.0 corresponds to this case. The definition of $c^*$ efficiency necessary to be used in this reconstruction technique is different from a $c^*$ efficiency obtained by a general method. Because the $c^*$ efficiency obtained by average chamber pressure and ${\xi}$ includes the $c^*$ loss due to the ${\xi}$ shift, it can be below unity even when the combustion gas keeps complete mixing and chemical equilibrium during the entire period of a firing. Therefore, the $c^*$ efficiency obtained in the present reconstruction technique is superior to the $c^*$ efficiency obtained by the general method to evaluate the degree of completion of the mixing and chemical reaction in the combustion chamber.

Study on Cooling Characteristics of Mixed Gases with Hot Gas of Liquid Rocket Engine and Injected Liquid Nitrogen (액체로켓엔진의 연소가스와 액체질소 혼합에 의한 연소 가스 냉각 특성에 관한 연구)

  • Jeon, Jun-Su;Yu, I-Sang;Kim, Joong-Il;Kim, Jai-Ho;Ko, Young-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.1001-1009
    • /
    • 2012
  • In this study, the cooling characteristics of combustion gas were investigated by injecting liquid nitrogen ($LN_2$) into a liquid rocket combustion chamber, which uses liquid oxygen (Lox) and kerosene as propellants. $LN_2$ injectors and an extended chamber for mixing were installed at the end of the ordinary LRE combustion chamber, and a nozzle was installed after the chamber for mixing. First, an ignition test of the liquid rocket engine was conducted to verify the stable combustion process. Next, a hot firing test was performed step-by-step for safety. Finally, the test was performed for 20 s. The results showed that the combustion gas of the LRE could be successfully cooled by using $LN_2$.

A Study on Combustion Characteristics of Flame Retardant Treated Pinus Densiflora (방염처리 육송의 연소특성 연구)

  • Choi, Jung-Min;Ro, Ho-Seung;Jin, Young-Hwa
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.57-62
    • /
    • 2011
  • The combustion characteristic was evaluated for Pinus densiflora, used as a building material in Hanok, which were treated with two different flame retardant method. The specimen was brushed with flame retardant liquid two or three times and then let the specimen dehydrated during 24 h for spreaded treating. And the other specimen was soaked in the liquid for 72 h. The test methods were inflammability test using meker burner and heat release rate test using cone calorimeter. As a result for the tests, flame retardant treated specimens met the requirements of the inflammability and the spreaded treated method was more efficient than immersed method. The spreaded treated specimen had lower combustive properties than immersed specimen in TTI (time to ignition), PHRR (peak heat release rate), MLR (mass loss rate) and THR (total heat release).

5 N Scale Preliminary Thruster Test with an ADN-based Monopropellant (5 N 급 ADN 기반 단일추진제 추력기 예비 연소 시험)

  • Monette, Maxime;Baek, Seungkwan;Kim, Juwon;Jung, Yeon Soo;Kim, Wooram;Jo, Youngmin;Lee, Jaewan;Kwon, Sejin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.2
    • /
    • pp.29-37
    • /
    • 2018
  • This paper reports the preliminary firing test performed with an ADN-based monopropellant using a 5 N scale thruster. ADN-based propellant and catalyst was fabricated and catalytic combustion of propellant was characterized by DSC-TG analysis. Although an explosion in the catalyst bed was occurred, high temperature in the catalyst bed obtained and demonstrated catalytic combustion of the propellant. Preliminary test results motivates the research for catalysts with better thermal stability.

Experimental Study on Ignition and Explosion Hazard by Measuring the Amount of Non-volatile (NVR) and Explosion Limit of Biodiesel Mixture (바이오디젤 혼합물의 가열잔분측정과 폭발한계 측정을 통한 발화 및 폭발위험성에 대한 실험적인 연구)

  • Kim, Ju Suk;Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.182-193
    • /
    • 2022
  • Purpose: By measuring and evaluating the risk of biodiesel through non-volatile residue (NVR) and flash point and explosion limit measurement at a specific temperature according to ASTM test standards, the risk of chemical fire causative substances is identified and a universal evaluation method By derivation and securing the risk-related data of the material, it can be used for the identification and analysis of the cause of the fire, and it can be applied to the risk assessment of other chemical substances Method: In order to measure the risk of biodiesel, it was measured using the non-volatile residue(NVR) measurement method, which measures how much flammable liquid is generated at a specific temperature. Heating was tested by applying KS M 5000: 2009 Test Method 4111. In addition, the flash point was measured using the method specified in ASTM E659-782005, and the energy supply method was measured using the constant temperature method. In addition, the explosion limit measurement was conducted in accordance with ASTM E 681-04 「Standard test method for concentration limits of flammability of chemicals(Vapors and gases)」 test standard. Result: As a result of checking the amount of combustible liquid by the non-volatile residue (NVR)measurement method, the non-volatile residue(NVR) of general diesel when left at 105±2℃ for 3 hours was about 30% (70% of volatile matter) and about 4% of biodiesel. In addition, similar results were obtained for the non-volatile residue(NVR)heating temperature of 150±2℃, 3 hours and 200±2℃ for 1 hour, and white smoke was generated at 200℃ or higher. In addition, similar values were obtained as a result of experimentally checking the explosion (combustion) limits of general diesel, general diesel containing 20% biodiesel, and 100% biodiesel. Therefore, it was confirmed that the flammability risk did not significantly affect the explosion risk. Conclusion: The results of this study suggested the risk judgment criteria for mixtures through experimental research on flammable mixtures for the purpose of securing the effectiveness, reliability, and reproducibility of the details of the criteria for determining dangerous substances in the existing Dangerous Materials Safety Management Act. It will be possible to provide reference data for the judgment criteria for flammable liquids that are regulated in the field. In addition, if the know-how for each test method is accumulated through this study, it is expected that it will be used as basic data in the research on risk assessment of dangerous substances and as a basis for research on the determination of dangerous substances.

Evaluation of Domestic CCPs(Coal Combustion Products) Quality by API Test Method (API시험법에 의한 국내 석탄회의 품질 평가)

  • Yoo, Sung-Won;Yu, Kyung-Geun;Cho, Young-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • Recently, recycling of industrial by-products and CO2 reduction have been important issues in the world. In this reason, applications and reuse of Fly ash as a binder for concrete, which is generated in thermoelectric power plant, have been one of the effective recycle methods. In order for Fly ash to be applied to concrete, Korean Standard(KS) has selected and managed quality such as $SiO_2$, fineness, specific gravity, ignition loss and activity index. However, there is a limits for activity index, whose test period required is at least 28 days or 91 days. Activity index is the critical indication standard to determine mechanical strength of concrete that contained Fly ash. To complement the disadvantage of test method, this research provided "API test method", which quickly measure Pozzolanic reaction of Fly ash can be considered as a alternative of activity index. Then, the adaptable API test method need to be investigated through comparative analysis with the test result of API, activity index and K-value. The test method can make evaluation of Fly ash quality faster and more accurate. As a result, most Fly ash produced in Korea has not been satisfied in the KS quality standard except water content and specific gravity, and especially fluidized bed boiler ash has its characteristics. Also, API, activity index and K-value have superior interrelationship. The interrelationship between API and activity index and K-value gets increased as the material age gets higher, so API test can be considered as very useful test method for Pozzolanic reaction evaluation of Fly ash.