• 제목/요약/키워드: Ignition Test

검색결과 468건 처리시간 0.087초

순간온도 계측 프로브를 사용한 피스턴 표면 온도측정 (A measurement of piston surface temperature by using instantaneous temperature measuring probe)

  • 이성열;이영조
    • 오토저널
    • /
    • 제12권6호
    • /
    • pp.60-66
    • /
    • 1990
  • In order to measure the piston surface temperature and heat flux, autors have developed the measuring system with an instantaneous temperature probe. Such the instantaneous temperature probes were embodied into the top of piston for measurement and L-link system, designed to fit the test engine, extracts the thermocouple wires from the piston outside of engine employing a mechanical linkage. Then the instantaneous surface temperature was measured to calculate the heat flux flowing into the top surface of piston in a spark ignition engine. As a result, the following phenomena have been obtained through the study. 1) It is found that the time response and durability of temperature probe with a thin film thickness 10um and mechanical linkage with thermocouple wire extraction is sufficient at this experiment. 2) For the quantitative effect of variation in engine speed, the temperature swing and heat flux on the top of piston increase with increasing the engine speed. 3) It is proved that the temperature swing and heat flux decrease with distance from spark plug.

  • PDF

자동차 엔진의 혼합연료가 엔진 성능과 배기가스에 미치는 영향에 관한 연구 (A Study on the Engine Performance and Emission of Gasoline-Methanol Blend in Vehicle Engine)

  • 조행묵
    • 한국분무공학회지
    • /
    • 제4권3호
    • /
    • pp.24-31
    • /
    • 1999
  • The engine performance and combustion characteristics of methanol blended fuel of spark ignition engine were discussed on the basics of experimental investigation. The effects of methanol blending fuel on combustion in cylinder were investigated under various conditions of engine cycle and blending fuel on combustion in cylinder were investigated tinder various conditions of engine cycle and blending ratios. The results showed thai the engine performance was influenced by the methanol blending ratio and the variations of operating conditions test engine. The increase of fuel temperature brought on the improvement of combustion characteristics such as cylinder pressure. the rate of pressure rise and heat release in an engine. The burning rate of fuel-air mixture, the exhaust emissions and the other characteristics of performance were discussed also.

  • PDF

Numerical predictions of the time-dependent temperature field for the 7th Cardington compartment fire test

  • Lopes, Antonio M.G.;Vaz, Gilberto C.;Santiago, Aldina
    • Steel and Composite Structures
    • /
    • 제5권6호
    • /
    • pp.421-441
    • /
    • 2005
  • The present work reports on a numerical simulation of a compartment fire. The fire was modeled using a simplified approach, where combustion is simulated as a volumetric heat release. Computations were performed with the commercial code CFX 5.6. Radiation was modeled with a differential approximation (P1 model), while turbulence effects upon the mean gas flow were dealt with a SST turbulence model. Simulations were carried out using a transient approach, starting at the onset of ignition. Results are provided for the temperature field time evolution, thus allowing a direct comparison with the analytical and experimental data. The high spatial resolution available for the results proved to be of great utility for a more detailed analysis of the thermal impact on the steel structure.

건전지의 방전에 의한 폭발성 가스의 점화에 관한 실험적 연구 (Experimental Study on Ignition of Flammable Gas by Spark of Dry Battery)

  • 이춘하;송현직;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1543-1546
    • /
    • 1994
  • Ignitabilility of explosive gas mixture by spark of dry cell in case of short circuit by accident was studied for the purpose of evaluation of intrinsically safe characteristics of dry cell that manufactured in Korea. IEC type spark test apparatus, $21{\pm}2$ Vol% of hydrogen - air mixture, and dry cell that produced in Korea was used for the experiment. The result of this research could be used for design, manufacturing, and using the intrinsically safe electrical apparatus.

  • PDF

낮은 엔진 부하의 운전조건에서 흡기포트 내 물 분사에 따른 가솔린 직접분사 엔진의 연소 특성 (Combustion Characteristics of Gasoline Direct Injection Engine with Water Injection into Intake Port under Low Engine-Load Operating Condition)

  • 전해강;이경환;최명식;박수한
    • 한국분무공학회지
    • /
    • 제23권2호
    • /
    • pp.96-101
    • /
    • 2018
  • The purpose of this study is to investigate the effect of water injection on combustion characteristics of gasoline direct injection (GDI) engine with turbo-charger under low-load operating condition. The test engine used in this study has four-cylinder and 10.2 of compression ratio. In order to study the effect of water injection ratio on combustion characteristics, the water was injected into the intake port from 10% to 50%, based on fuel injection quantity. From the experiment, it revealed that the water injection induced the improvement of fuel economy because of the advance of spark-timing by the reduction of in-cylinder temperature. In addition, the water injection caused the prolong of extension of the ignition delay and slight increase of burn duration.

HVDC시스템에서 AC 필터 차단기의 TRV해석 (TRV Analysis for AC Filter Circuit Breaker in HVDC System)

  • 김찬기;김진영;신진철
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.369-374
    • /
    • 2015
  • The circuit breaker in an electric power system is not operated when the voltage in the circuit breaker is higher than the rated transient recovery voltage (TRV). The TRV of a circuit breaker is characterized by re-ignition of the arc between two poles and determined by the value of connecting impedance. In this study, we simulated the peak value of TRV in the AC filter of the circuit breaker. The suitability of TRV is assessed by capacitive current switching test conditions defined by the international guide IEC62271-100.

시멘트 분쇄공정별 물성에 관한 기초적 연구 (A Fundamental Study on the Properties of Cement Collected at Different Process Line)

  • 김종백;차완호;권오봉;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.111-114
    • /
    • 2006
  • This paper is to investigate the chemical composition and physical properties of cements collected at different crushing process line of ordinary portland cement to verify the possibility for producing special purpose cement based on the particle distribution technique. According to test results, six different cement samples with different blaine were gathered. loss on ignition and chemical composition of cements gathered were satisfied with KS L 5201. Cement collected at line 5 had the lowest blaine value while cement at line 4 had the highest blaine value. The coarser the cement particle is, the larger the fluidity of cement is. The compressive strength of cement was highly affected by the blaine value of cement. It is confirmed that the use of cement produced by the process of particle distribution control may be applied for special purpose cement without modification of chemical composition.

  • PDF

Realization of a Metalized Gel Fuel Ramjet

  • Natan, Benveniste
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.135-140
    • /
    • 2010
  • The high specific impulse of the ramjet engine, combined with the ability of a gel to carry metal particles, make the Gel Fuel Ramjet a most adequate solution for a mid-high range sustainer. The goal of the present study is to verify experimentally the feasibility of such a concept. A test facility and a lab-scale motor have been designed and built to investigate atomization, ignition and firing processes of a gel hydrocarbon fuel, with and without metal additives, as well as to check the ramjet operation as a whole. The present paper presents the experimental system in detail as well as qualitative results of a few firing tests.

  • PDF

A MULTI-STORY FIRE IN HIGH-RISE APARTMENT BUILDING DEVELOPED THROUGH BALCONIES - INVESTIGATION AND EXPERIMENTS -

  • Hasemi, Yuji;Hayashi, Yoshihiko;Hokugo, Akihiko;Yoshida, Masashi
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.361-368
    • /
    • 1997
  • Summary of experiments for the investigation of a fire which caused an upward fire spread for over 12 floors through balconies in a high-rise apartment complex is reported. The experiments include indoor tests to obtain fire properties of vertical PMMA fences and outdoor ones with a full scale model of the balcony. The test results suggest significance of the increase of total flame height by the merging of flames and a cooperative effect of the burning of the PMMA fence and combustibles on the balconies for the generation of a tall flame enough to cause ignition on the upper floors.

  • PDF

팬형분무의 주변조건에 따른 입자분포 변화 (The Droplet Size Distribution of Fan Spray at Different Surrounding Conditions)

  • 문석수;최재준;배충식
    • 대한기계학회논문집B
    • /
    • 제31권7호
    • /
    • pp.611-619
    • /
    • 2007
  • In this study, the droplet size distribution of a slit injector at different surrounding conditions, such as air flow and fuel temperature, were investigated. Phase Doppler anemometry (PDA) was utilized to investigate the initial droplet size distribution and the effect of fuel temperature and air flow on droplet size distribution. The entrained air motion was also evaluated by the temporal velocity profile of droplets. When the air flow velocity increased, the small droplets were more entrained to the upper and central parts of the spray and this tendency was confirmed by plotting the temporal velocity profile of droplets. This entrainment of small droplets at high airflow velocities caused relatively small mean droplet size at upper and central parts of the spray and the large mean droplet size at downstream and edge of the spray, compared to that of low airflow velocities. The total mean droplet size, obtained by averaging the size of all droplets measured at all test locations, decreased when the high airflow velocities were applied. The increased fuel temperature, with an airflow velocity of 10m/s, caused reduced droplet size at all test locations. However, the decreased value of mean droplet size at high fuel temperatures was relatively higher at upper parts of the spray, compared to downstream, as a result of enhanced entrainment of small droplets to upper parts of the spray.