• Title/Summary/Keyword: Ignition Test

Search Result 468, Processing Time 0.024 seconds

Emergency Blockage Application of Engine Part for Integrated Propulsion Performance Test (추진시스템 종합성능시험에서의 엔진부 비상정지 설정)

  • 하성업;이정호;권오성;김병훈;강선일;한상엽
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.171-176
    • /
    • 2003
  • A Test Facility was established to carry out the integrated propulsion performance tests(IPPT). To perform IPPT's with maximum safety, an emergency blockage system was investigated. An emergency blockage system using combustion chamber pressure and acceleration signals was set up to monitor ignition delay and fail, flame out, propellant feeding status, unstable combustion and excessive structural vibration. With such system, the maximum safety could be secured by rapid judgement and follow-up measures, which made IPPT's be safely completed.

  • PDF

Design of Capacitor Load Bank for Capacitive Current Switching Tests (진상소전류시험용 Capacitor Load Bank 설계)

  • Roh, Chang-Il;La, Dae-Ryeol;Kim, Sun-Koo;Jung, Heung-Soo;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.106-108
    • /
    • 2002
  • Capacitive current switching test for circuit breaker and load breaker switch requires special attention because, after current interruption, the capacitive load contains an electrical charge and can cause dielectric restrike and re-ignition of the switching devices. therefore dielectric strength of capacitor load bank shall be able to withstand 4Vt (Vt : test voltage) and charging voltage discharged within 1 min. In this paper presents both characteristic of capacitive current switching tests and design of capacitor load bank.

  • PDF

A Study on the Combustion Characteristic and Soot Distribution of a Common Rail Type D.I.Diesel Visualized Engine with Pilot Injection (커먼레일식 직분식 가시화 디젤엔진의 파일럿 분사 연소 및 Soot 분포 특성에 관한 연구)

  • Han, Yong-Taek;Lee, Jae-Yong;Lee, Ki-Hyung
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.31-37
    • /
    • 2003
  • The objective of this work is to investigate the effect of swirl, injection pressure and pilot injection on D.I.Diesel combustion by using a transparent engine system. The test engine is equipped with common rail injection system to obtain high pressure and to control injection timing and duration. In this study, the combustion analysis and steady flow test were conducted to estimate the heat release rate from in-cylinder pressure and pilot injection was investigated by using LII technique. As the results, high injection pressure was found to shorten ignition delay as well as enhance peak pressure and heat release rate was greatly affected by injection timing and pilot injection. In addition, the results showed that the period of soot formation corresponded to the diffusion flame.

  • PDF

MEMS Application of Quenching Effect to a Novel Micro Solid Rocket

  • Ebisuzaki, Hideyo;Nagayama, Kunihito;Ikuta, Tatsuya;Takahashi, Koji
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.601-604
    • /
    • 2004
  • Precise position and attitude control of pico-satellite requires huge number of impulses of the order of 10$^{-6}$ Ns. MEMS solid rocket array is a promising propulsion system but the higher degree of miniaturization causes unreliable operation mainly due to quenching. In order to breakthrough this situation, a novel design of solid micro-rocket is proposed, which generates tiny impulses repetitively from a single rocket not from array. This unique micro-rocket is based on the utilization of quenching, which causes propellant reaction to sustain only in a small area. A test chip of a micro solid propellant tank and micro heater array is fabricated and ignition test is conducted. Obtained results show the feasibility of this concept and future direction of this quenching-based propulsion is discussed.

  • PDF

The Flame Image Observation for Monitoring Management of Pulverized Coals Firings and its Feasibility Test to Boilers for Thermal Power Plant (미분탄 연소의 감시 관리를 위한 화염영상 감시 및 발전용 보일러 적용시험)

  • Baek, Woon-Bo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.92-98
    • /
    • 2008
  • The flame image observation and analysis has been investigated for combustion monitoring and management of the pulverized coal firing for thermal power plant, especially for lower nitrogen oxide generation and safer operation. We aimed at obtaining the relationship between burner flame image information and emissions of nitrogen oxide and unburned carbon in furnace utilizing the flame image processing methods, by which we quantitatively determine the conditions of combustion on the individual homers. Its feasibility test was undertaken with Samchonpo thermal power plant #4 unit which has 24 burners, through which the system was observed to be effective for evaluating the combustion conditions and continuous monitoring to prevent future loss of ignition.

The Effects of Fuel Injection Skips on the Reduction of Harmful Exhaust Gases during an SI Engine Starting (가솔린 기관의 시동시 연료분사스킵이 유해배출가스 저감에 미치는 영향)

  • Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.5-11
    • /
    • 2006
  • During the SI engine starting up, starting conditions directly contribute to the harmful emissions in spark ignition engines. The effects of catalyst temperatures and fuel injection skip methods on HC emissions were investigated. The test was conducted on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine. To understand the formation of HC emissions, HC concentration was measured in an exhaust port using a Fast Response Flame Ionization Detector(FRFID). The result showed that HC emissions, which were generated during initial stage of the starting, could be reduced by coolant temperature and fuel injection skips. And through the vehicle test of ECE15+EUDC, it is convinced that the optimized fuel injection skip method according to coolant temperatures have favourable effects on the reduction of harmful exhaust emissions including HC during the SI engine start.

  • PDF

A Study on thinner's Physicochemical property and its effect on genital organ of rat (시너(thinner)의 물리화학적 특성과 랫트의 생식기에 미치는 영향 연구)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Kim, Tae-Gyun;Lee, Jung-Suk;Kang, Min-Gu;Lee, Chae-Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.224-238
    • /
    • 2008
  • The aim of this study is to confirm the physicochemical property and hazard of thinner (012), which is a diluent of enamel paint used for floor coating for waterproofing and oil painting for the outer wall. The literatures of physicochemical property and hazard of thinner were surveyed and its physicochemical property were evaluated. And then, the inhalation toxicity of thinner affecting the central nervous system and reproductive organs in rats were examined by subchronic (6 h./day. 5 days/ week for 13 weeks) inhalation test. 1) According to the 13-week subchronic inhalation test, there were no significant changes in clinical test and body weight. However, a significant evidence of toxicity was observed in the hematological test and organ weight such as heart, kidney, liver and brain (p<0.01) in the 200 ppm and 1,000 ppm exposure groups in a dose response manner. In the histopathology analysis, there were no significant evidence of toxicity. Therefore, thinner was not classified as an organ targeted toxic agent. In case of Harmfulness, it could be classified as a chronic toxic agent 3($500 ppm/4hr, rat). 2) The reproductive toxicity such as extension of the period of estrous cycle, reduction of serum estradiol concentration and increase of frequency of the abnormal sperm was observed in the 1,000 ppm exposed animals. 3) The result of the physicochemical property of the test material showed that the specific gravity was 0.793, boiling point $155.8^{\circ}C$, steam pressure 2.1 kPa, ignition point $34.5^{\circ}C$, and spontaneous ignition point $280^{\circ}C$. The endothermic and exothermic values were 371.4 J/g and 159.1 J/g. respectively. The explosion limit was 214 mg/l. These data showed that thinner could be classified as an explosion agent level 1.2 and ignitive liquid agent 3 ($23-60^{\circ}C$) according to the notification No. 2008-1 of the Labor Ministry, "Classifying Standard of Chemical Materials."

Certification Test Result of After-burner Test Facility for Gas-generator of 75 tonf Class Liquid Rocket Engine (75톤급 액체로켓엔진용 가스발생기 후연소 시험설비 인증시험 결과)

  • Kim, Chae-Hyoung;Lee, Kwang-Jin;Han, Yeoungmin;Chung, Yonggahp
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.91-97
    • /
    • 2015
  • After-burner test facility for gas generators of 75 tonf class liquid rocket engines was designed, which was verified by the facility certification test of the Combustion Chamber Test Facility(CCTF). The purpose of the certification test of the after-burner test facility is to verify the combustion stability of gas torches equipped in the gas generator and the after-burner test facility by using methane and oxygen gases. In the case of the autonomous test, the supply system provided steadily methane and oxygen gases to the after-burner system without pressure drop. The combustion pressure of the gas torch approached the design requirement. In the case of the coupled test, the gas generator ignition and the fuel-rich exhaust gas combustion were successfully carried out, leading to the verification of the test facility.

A Study on the Shelf-life Prediction of the Single Base Propellants Using Accelerated Aging Test (가속노화시험을 이용한 단기추진제의 저장수명예측에 관한 연구)

  • Lee, Jong-Chan;Yoon, Keun-Sig;Kim, Yong-Hwa;Cho, Ki-Hong
    • Journal of Korean Society for Quality Management
    • /
    • v.35 no.2
    • /
    • pp.45-52
    • /
    • 2007
  • The danger of self-ignition of single base propellants will increase with time. Therefore, a good prediction of the safe storage time is very important. In order to determine the remaining shelf-life of the propellants, the content of stabilizer is determined. The propellants stored under normal storage conditions about 10 to 18 years were investigated and accelerated aging test was carried out by storing propellant sample at higher temperature. Finally, we analyzed the results by various methods in order to show the best way to predict the realistic shelf-life. The safe storage life of the propellants will be 24 years, at least 15 years. In case of applying Arrhenius's law, using the reaction rate constant at 28$^{\circ}C$ to 30$^{\circ}C$ to predict the shelf-life by accelerated aging test is reasonable for a good prediction.

ANALYSIS OF STEADY FIRE-DRIVEN FLUID FLOW FOR RAILWAY TUNNEL BY DIFFERENT VELOCITY CONDITIONS AT THE END OF TUNNEL (종단부 유속조건 변화에 따른 철도터널 내 정상상태 화재유동해석)

  • Lee, D.C.;Lee, D.H.;Jung, W.S.;Park, S.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.208-213
    • /
    • 2010
  • In this study CFD(Computational Fluid Dynamics) analysis of the steady fire-driven fuid flow for the performance test of ventilation at railway tunnel between Heuksok and Nodeul Station from Seoul Metro 9 is performed. There were fans with exhaust and intake modes and each was installed at the middle and both ends of the tunnel. For this test, the pool fire source of methyl alcohol with 1.5MW and smoke generators were installed between the middle of tunnel and Heuksok Station. In this test, the smoke behavior from natural convection was observed for 10 minutes from the ignition of pool fire and then fans with intake-modes at both sides of Heuksok effect of fan-on with intake mode located in the opposite side of the tunnel nearby Heuksok Station on fire-driven fluid flow is studied on when the boundary conditions of fan-on at the tunnel between Heuksok and Nodeul Station are the same as test. FLUENT, a commercial CFD code, is used for this analysis.

  • PDF