• Title/Summary/Keyword: Ignition Loss

Search Result 336, Processing Time 0.03 seconds

An Analysis of the Relationship of Soil Factors to the Height Growth of Pinus densiflora within the Young Natural Stands in Central Korea (중부한국의 자연생 소나무의 연 신장성장율에 영향을 미치는 토양요인들에 대한 다요인 분석)

  • 오계칠
    • Journal of Plant Biology
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 1972
  • To study on the annual height growth of Pinus densiflora within natural pine stands in central Korea, twenty two pure closed Pinus densiflora stands were selected subjectively in the west-central region of Korea. In each stand twenty trees were chosen randomly. For each tree, abotu ten to fifteen measurements of internodal lengths were made from leader top to trunk base. A total of one hundred thirty four soil samples was collected. Each soil sample was bulked with three subsamples. The ranges of the growth measurements per stand, per tree and per observation were 14.9-35.4cm, 9.0cm-54.4cm and 2.4cm-69.0cm respectively. The total mean value was 23.5cm. The Student-Newman-Keul's tests for the multiple comparison among the mean values of the height growth per stand were very highly significant. The resutls of the analysis of variance of the height growth data for the selected fifteen stands among the twenty two stands indicate that sampling efficiency might be increased to 744% if measurement of the growth were made on fifteen trees per stand from twenty stands instead of twenty trees per stand from fifteen stands. The annual height growths of Pinus densiflora and Pinus koraiensis for the period from 1960 to 1968 were 21.74$\pm$5.29cm (10) and 20.56$\pm$5.59cm (10) respectively. The total means of easily-soluble phosphorus, total nitrogen, loss on ignition and pH for the soil samples were 2.8 ppm, 0.09%, 5.4% and 4.7 respectively. The ranges of those amounts were 18.7-1.7ppm, 0.17-0.05%, 11.6%-3.1%, 3.9-5.1 respectively. The relationship of the annual height growth of P. densiflora to soil was studied in terms of standard partial multiple regression. Among soil properties such as non-capillary pore space, capillary pore space, maximum field capacity, loss on ignition, soil reaction, total nitrogen and easily-soluble phosphoros investigated, the easily soluble phosphorus in one analysis and loss on ignition and soil reaction in the other analysis seem to have significant positive influence on the annual height growth.

  • PDF

A Study on the Comparison of the Combustion Characteristics among an IDI, a HSDI Diesel Engine and a SI Engine using One-zone Heat Release Analysis (단일영역 열발생량 계산법을 사용한 IDI, HSDI 디젤엔진과 SI엔진의 연소특성 비교에 관한 연구)

  • Lee Sukyoung;Jeong Kuseob;Jeon Chunghwan;Chang Yongjune
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.21-30
    • /
    • 2005
  • Heat release analysis is a very importent method in understanding the combustion phenomena inside an engine cylinder. In this study, one-zone heat release analysis was used with the mesured cylinder pressures of an IDI(indirect injection), a HSDI(high speed direct injection) and a SI(spark ignition) engine. It has benefits of simple equation, fast speed, reliability. The object of the study is to compare the combustion characteristics among an IDI, a HSDI and SI engine. Result of analysis, the maximum heat release rate of a HSDI is higher than an IDI because of long ignition delay period. The heat release curve of a IDI is more linear than an HSDI, so the combustion characteristics of a IDI is similiar to that of an SI engine. There is a suggestion here that the combustion efficiency of a HSDI is highest of that of all engines because of the smallest heat transfer loss of all engines.

The Distribution Characteristics of Grain Size and Organic Matters of Surface Sediments from the Nakdong-Goryeong Mid-watershed (낙동·고령 중권역의 표층 퇴적물 입도 조성 및 유기물질 분포 특성 변화)

  • Kim, Shin;Ahn, Jungmin;Kim, Hyounggeun;Kwon, Heongak;Kim, Gyeonghoon;Shin, Dongseok;Yang, Deukseok
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.411-423
    • /
    • 2018
  • To investigate the distribution characteristics of grain size and organic matter of surface sediments from the Nakdong-Goryeong Mid-watershed, surface sediments were collected and analyzed. The samples were collected from six sited at four different times between May 2013 and May 2014. The were analyzed for grain size, water content, ignition loss, chemical oxygen demand, total organic carbon and total nitrogen. The surface sediments were mainly composed of medium sand (mean 44.7%) and coarse sand (mean 32.8%) and became coarser in May 2014. Fine sediments at the site NG-2 were poorly sorted and positively skewed, and occur in a tributary environment that is relatively low-energy compared with the other sites. The water content at the studied sites (15.3 ~ 34.9%) averaged 20.25%, and ignition loss (0.4 ~ 5.8%) and total nitrogen (274 ~ 2493 mg/kg) averaged 1.33% and, 696 mg/kg, respectively. These values indicated that the sediments were not seriously contaminated when compared with the sediment pollution evaluation standard of the National Institute of Environmental Research. The chemical oxygen demand (mean 0.17%) was at the non-polluted level compared with United States Environmental Protection Agency sediment quality standards. The total organic carbon (mean 0.18%) at all sites except site NG-2 (lowest effect level) was the no effect level of the Ontario sediment quality guidelines. The COD/IL (0.02 ~ 0.20) and C/N (0.73 ~ 6.76) were less than 1 and 10, respectively. Organic matter in the study area produced naturally from aquatic organisms. Results of principal component analysis showed that fine sediments (very fine sand and silt) were significantly affected by organic matters (ignition loss, chemical oxygen demand, total organic carbon and total nitrogen). In addition, the highest organic matters content in the study area occurred at the site with the finest sediments (NG-2).

Estimation of Contamination Level of Sediments at the Below of Busan Gwang-an Bridge (부산 광안대교 하부 퇴적토 오염도 평가)

  • Kim, Seog-Ku;Ahn, Jae-Whan;Kang, Sung-Won;Yun, Sang-Leen;Lee, Jungwoo;Lee, Jea-Keun;Lim, Jun-Heok;Kim, Dong-Soo;Lee, Tae-Yoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.809-814
    • /
    • 2013
  • In this study, physical properties and heavy metal contents of sediments obtained from the bottom of Gwangan bridge were measured to determine pollution level of the sediments. From the results of the oxide contents of the sediments, $SiO_2$ was decreased as the sampling points became more distant from the stream of river. On the contrary, CaO showed opposition aspect to $SiO_2$. Ignition loss of sediments ranged from 7.2 and 14.3% and 0.9 and 5.5% for TOC. For EPA guidelines of ignition loss, all sampling points were classified as heavily polluted areas. When TOC was considered, all areas were classified as lowest effect level except for GW7 where classified as no effect level. All areas were free of heavy metal contamination evaluated by USEPA and Canadian guidelines. However, all areas were classified as heavily contaminated areas due to the high value of ignition loss when USEPA was used.

Change in Geochemical Characteristics of Surface Sediments in the Nakdong River Main Stream (낙동강 본류에 분포하는 표층 퇴적물의 지화학적 특성 변화)

  • Kim, Shin;Lee, Kwonchul;Kim, Jueon;Jung, Kangyoung;Ahn, Jungmin;Kim, Hyounggeun;Lee, Injung;Shin, Dongseok;Yang, Deukseok
    • Journal of Environmental Science International
    • /
    • v.26 no.3
    • /
    • pp.311-324
    • /
    • 2017
  • To certificate change in the geochemical characteristics of surface sediments in the main stream of the Nakdong River, surface sediments from 12 sampling sites during the first and second half year (total 24 sampling sites) were collected and analyzed for grain size, ignition loss, total organic carbon and heavy metal content. Surface sediments mainly composed of sand (coarse and medium sand) and fining changed from the first half to the second half of the year. Ignition loss, total organic carbon and heavy metals content increased in the second half of the year. Some heavy metals (Zn, Ni and Cu) were found to be at the lowest effect levels according to Ontario sediment quality guidelines. Additionally, most heavy metals were found to be at the non polluted level and level I according to USEPA sediment quality standards and National Institute of Environmental Research sediment pollution evaluation standard, respectively. The enrichment factor (< 1) and index of geoaccmulation (< 0) were non polluted in the study area. The correlation analysis results showed that ignition loss, total organic carbon and heavy metal content were highly correlated with grain size. Regarding changes in geochemical characteristics of surface sediments in the study area, grain size fine and organic matter and heavy metal content increased in the second half year. Nonetheless these results indicated pollution levels that did not adversely affect the benthos.

Sludge Minimization by Using Dewater and Thermal Treatment in the Water Treatment Plant (탈수(脫水) 및 건조기법(乾燥技法)을 이용한 정수장(淨水場) 슬러지 감량화(減量化))

  • Jun, Hang-Bae;Kim, Yong-Han;Kim, Ryang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.2 no.1
    • /
    • pp.87-98
    • /
    • 1994
  • Sludge minimization in an water treatment plant can be achieved by optimizing a main water treatment process as well as by enhancing a thickening and a dewatering facilities. In this study, dewatering and drying techniques for reducing the quantity of the water sludge generated from the conventional water treatment plant in the local states were investigated by reducing its water content. Not only the types and dosages of polymers but also the mixing intensity of the mixtures of a concentrated sludge and polymers on the different pH were evaluated for the optimum dewatering conditions of the water sludge. Weight reduction of the water sludge was also tested at a given temperature range. The dewatering efficiency of the water sludge was not affected by the types of polymer but by mixing intensity(GT value) in this study. pH effect on dewaterbility of the water sludge took a major role at the neutral pH range. The optimal polymer dose was 1.5 mg-polymer/g-TSS(about 40mg/L as polymer). Dewaterability was enhanced at a lower mixing intensity(GTbelow 10,000 sec-1). Free water in the void of sludge cake was dried around $100^{\circ}C$, chemical bound water was evaporated around $320^{\circ}C$, and organic material was burned out at the range of 300 to $600^{\circ}C$. Ignition losses of the water sludge were varied 15 to 40 % as the raw water quality. The ignition loss due to the chemical bound water was 10-20% and the loss due to the organic material was 4-20% of the total ignition loss.

  • PDF

A Study on the Ignition Behaviors of Textiles according to Permeation Amount of Oils and Aeration (유지류의 침윤량과 공기주입에 따른 면화류의 발화거동에 관한 연구)

  • 오치훈;이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.8-12
    • /
    • 2000
  • We had investigated thermal and ignition behaviors of textiles. Decomposition of textiles with temperature was investigated using a DSC and the weight loss according to temperature using a TGA in order to find the thermal hazard of textiles, and the ignition behaviors of textiles according to species and permeation amount of oil. In addition, ignition behaviors of those permeated into oils indicating different iodine value and of those with arid without air in reaction vessel of measuring equipment were studied with constant temperature method among ignition temperature measuring methods. As results, the range of decomposition temperature of synthetic fiber was slightly broad compared with that of natural fiber, pure cotton. Besides, the initiation temperature of heat generation of both samples riced in the case of no air injection in the reaction vessel. On the other hand, in the case of air injection that was lowered according to the increase in permeative amount of oils and fats and decreased quickly as sample was permeated into drying oil.

  • PDF

Radiation Effects on the Ignition and Flame Extinction of High-temperature Fuel (고온연료의 점화 및 화염 소화특성에 미치는 복사효과)

  • Kim, Yu Jeong;Oh, Chang Bo;Choi, Byung Il;Han, Yong Shik
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.50-56
    • /
    • 2013
  • The radiation effects on the auto-ignition and extinction characteristics of a non-premixed fuel-air counterflow field were numerically investigated. A detailed reaction mechanism of GRI-v3.0 was used for the calculation of chemical reactions and the optically-thin radiation model was adopted in the simulations. The flame-controlling continuation method was also used in the simulation to predict the auto-ignition point and extinction limits precisely. As a result, it was found that the maximum H radical concentration, $(Y_H)_{max}$, rather than the maximum temperature was suitable to understand the ignition and extinction behaviors. S-, C- and O-curves, which were well known from the previous theory, were identified by investigating the $(Y_H)_{max}$. The radiative heat loss fraction ($f_r$) and spatially-integrated heat release rate (IHRR) were introduced to grasp each extinction mechanism. It was also found that the $f_r$ was the highest at the radiative extinction limit. At the flame stretch extinction limit, the flame was extinguished due to the conductive heat loss which attributed to the high strain rate although the heat release rate was the highest. The radiation affected on the radiative extinction limit and auto-ignition point considerably, however the effect on the flame stretch extinction limit was negligible. A stable flame regime defined by the region between each extinction limit became wide with increasing the fuel temperature.

A Study on the Combustion Characteristics of Phenol Foam (페놀 폼의 연소특성에 관한 연구)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.122-127
    • /
    • 2010
  • The combustion characteristics of phenol foam were analysed using variable external irradiation level (20, 25, 35, 50, and $70kW/m^2$) and in the mixture gas of oxygen/nitrogen. The oxygen index were carried out from the oxygen index tester (KS M ISO 4589-2) and ignition time, critical heat flux, and mass loss rate were carried out from the mass loss calorimeter (ISO 5660-1). As the results of this study, the critical heat flux and average mass loss rate were $28.99kW/m^2$ and $0.56{\sim}1.77g/m^2s$ respectively at the variable external irradiation level. And the limited oxygen index were 45.1% in mixture gas of oxygen/nitrogen. In conclusion, we knew that phenol foam had the best performance than other foam materials in fire safety from all data of this study.