• Title/Summary/Keyword: Ignition Characteristic

Search Result 164, Processing Time 0.025 seconds

A Study on the Evaporation and Ignition of Single Fuel Droplet on the Hot Surface (고온벽면에서의 액적연료의 증발 및 착화에 관한 연구)

  • 송규근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.132-137
    • /
    • 2002
  • Recently, impinging spray is used for atomization of diesel engine, but it bring on adhesion of fuel. Therefore, we studied about droplet behavior on high temperature plate changing the size of droplet, surface temperatures, and surface roughness of plate. In this study, We studied to confirm experimentally about mechanism of evaporation and ignition process of single fuel droplet. We observed evaporation time, evaporation appearance and ignition delay time by the photopraphs of 8mm video camera. Experimental results are summarized as follows: 1. The boiling point of fuel affect a evaporation and ignition process. 2. The surface roughness affect a evaporation time. 3. The ignition delay time relate to evaporation characteristic.

On the Characteristics of Extinction and Re-ignition in a Crossed Twin Jet Counterflow (Crossed Twin Jet Counterflow에서의 소염과 재점화 특성)

  • Lee, B.K.;Yang, S.Y.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.25-31
    • /
    • 2002
  • For the better understanding of the stability of turbulent combustion, more researches on extinction and re-ignition are needed. Flame interactions in non-premixed flame have also not been greatly researched. We made a hybrid twin jet flame, the combinations of diffusion flame and partially-premixed diffusion flame, in a twin jet counterflow configuration. The extinction limits of a crossed twin jet counterflow have been extended in comparison with those of a one-dimensional counterflow because of flame interactions through heat transfer and joint ownership of various radicals. Besides, we have obtain ignition $Damk\"{o}hler$ number by experimental method without external ignition source using the extinction characteristic in a crossed twin jet counterflow flame. From results, we can identify the hysteresis between extinction and ignition $Damk\"{o}hler$ number in S-curve.

  • PDF

A Study on the Ignition Characteristics at Constant Volume Combustion Chamber of LPG (LPG 정적연소실내 점화특성에 관한 연구)

  • 박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.75-82
    • /
    • 2004
  • The allowable exhaust standard has been intensified as a part of the countermeasure to decrease air pollution in the world. As the cars with an alternative fuel starts to get into the spotlight, the cars with low emission has been introduced and exhaust gas regulation forced in this country. These days, LPG vehicles, which infrastructure of fuel was already built up, and CNG vehicles are recognized for alternative fuel cars in this country. In this study, the constant volume combustion chamber was manufactured and used for experiments to obtain the ignition characteristics of LPG fuel and the optimal ignition energy. The experiment measured the combustion characteristics, in regard to the change of combustion variable, and the change of ignition energy. During the combustion of fuel, the maximum temperature inside the combustion chamber is higher when the initial pressure is higher. The burning velocity also seems to have the same characteristic as the temperature. However, the heat flux did not change much with the theoretical correct mixture but the various initial temperature of the combustion chamber. The heat flux got faster and ignition energy bigger as the dwell time of the ignition system expanded. When the dwell time get longer, the ignition energy also increased then fixed. The ignition energy increased as the initial pressure inside the combustion chamber higher. The heat flux got faster as the dwell time expanded.

An investigation on ignition ability of the repetitive sparks (반복점화방식의 점화능력에 관한 연구)

  • 조경국;정인석
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-65
    • /
    • 1988
  • The ignition characteristics of repetitive electric sparks into a quiescent acetylene-air premixture and LPG-argon-air premixture was investigated by using a home-made Repetitive-Spark-Generator(RSG) to elucidate the effect of fuel burning velocity to ignition ability of RSG. Results show that the optimum spark delay time interval is strongly related with fuel burning velocity, or implicitly with characteristic reaction time scale of each fuel.

  • PDF

Ignition and Extinction Characteristics of a Low Thrust Combustion Chamber using Green Propellant according to Sequence of the Combustion Test (친환경 추진제를 사용하는 저추력 액체로켓엔진의 연소시험 시퀀스에 따른 점화 및 소염 특성)

  • Kim, Young-Mun;Jeon, Jun-Su;Choi, Yu-Ri;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.130-133
    • /
    • 2009
  • The sequence of the propellant supply is very important for the reliable and safe operation of a LRE combustion test. So combustion performance tests were performed to find an optimum test sequence by changing supply time of propellants and purge gas in the moment of ignition and extinction. The liquid rocket engine consisted of a catalytic ignitor and six swirl-coaxial injectors which used hydrogen peroxide and kerosene. Conclusively, an optimum sequence was found for stable combustion in the moment of ignition and extinction.

  • PDF

Design of Hydrogen Peroxide/Kerosene Ignitor and Ignition Characteristic according to Operation Condition (친환경 추진제를 사용하는 액체로켓엔진 점화기의 설계 및 운용 조건이 점화 특성에 미치는 영향)

  • Hwang, Oh-Sik;Kim, Tae-Woan;Jeon, Jun-Su;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.74-77
    • /
    • 2009
  • Ignition performance tests were performed to develop a catalytic ignitor which used hydrogen peroxide and kerosene. Ignition characteristics were investigated by exit area of the catalytic bed, shape of kerosene injector and lead time of purge gas. The results showed that exit area of catalytic bed must be enough for non chocking condition and kerosene must be sprayed with swirl in the middle of catalytic bed. Also in case without preheating of catalytic bed, hydrogen peroxide must be leaded by 3sec, and purge gas must be supplied simultaneously or lately with kerosene.

  • PDF

An Experimental Study on the Ignition Characteristic of Ignition Plug (점화플러그의 점화특성에 관한 실험적 연구)

  • Sim, Sang-Cherl;Cho, Tae-Young;Jung, Byoung-Koog;Song, Kyu-Keun;Jung, Jea-Youn;Kim, Hyung-Gon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2088-2093
    • /
    • 2004
  • Harmful elements from the exhaust gases are caused by incomplete combustion of mixture inside the engine cylinder and this abnormal combustion like misfire or partial burning is the direct cause of the air pollution and engine performance degradation. In this study, I obtain the shapes of spark, voltage and current generated when changing the experimental parameters such as grounded electrode shapes, electrode gap and the material of center electrodes. After that, I produce ignition energy by using the voltage and current and classify ignition energy into capacitive discharge energy and inductive discharge energy.

  • PDF

Asymptotic analysis of ignition of a semi-infinite body for a large activation energy (활성화 에너지가 매우 큰 경우에 점근법을 이용한 반무한체의 점화에 관한 연구)

  • 백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.703-707
    • /
    • 1989
  • The ignition of solid particle under strong convective heating has been investigated by applying an asymptotic analysis to a semi-infinite body for varying values of gas recovery temperature and convective heat transfer coefficient. It was found that if the scale of the reaction zone is much smaller than the characteristic length of the body size, then infinite body theory can be used to estimate the ignition delay time. Furthermore, the convective heat transfer coefficient was found to have more influence on predicting the ignition delay times of particle exposed to an incident shock wave rather than the gas recovery temperature.

Study on Properties of Interior Ballistics According to Ignition-Gas Injections (점화제 주입에 따른 강내탄도 성능해석)

  • Jang, Jin-Sung;Sung, Hyung-Gun;Lee, Sang-Bok;Roh, Tae-Seong;Choi, Dong-Whan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • Using the numerical code for the interior ballistics, the performance of the interior ballistics with the characteristic of the ignition-gas injections has been investigated. The ignition gas has been assumed to be injected into the chamber with 3 cases. As the results of analysis, when the ignition-gas has been injected into all chamber area, the pressure distributions of the chamber of the interior ballistics have been uniform and the differential pressure has been stable. The ignition-gas has been injected into the partial area of the chamber, however, the pressure distributions and the differential pressure have been unstable. The case using the longer ignition injector, therefore, seems to be more suitable to improve the stability of the interior ballistics.

Analysis on Ignition Delay Time According to the Ratio of Bio-aviation Fuel in Jet A-1 Mixture (바이오항공유의 함량 변화에 따른 점화지연특성 분석)

  • Kang, Saetbyeol;Jeong, Byunghun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.13-20
    • /
    • 2019
  • In this study, the ignition delay time of blended aviation fuels was measured and analyzed to confirm the characteristic of ignition delay according to the blending ratio of bio-aviation fuel to petroleum-based aviation fuel. The ignition delay time of bio-aviation fuel(Bio-6308) was shorter than that of petroleum-based aviation fuel(Jet A-1) at all measured temperatures; further, the ignition delay time of the blended aviation fuels shortened as the ratio of Bio-6308 increased. It was confirmed that the aromatic compounds constituting the Jet A-1 affect these results; this was done by comparing the obtained ignition delay time with that of n-heptane/Toluene.