• 제목/요약/키워드: Ignition & Growth Model

검색결과 19건 처리시간 0.03초

고온, 고압의 분위기 변화가 n-butanol 및 n-heptane 연료의 연소 특성에 미치는 영향 (Effect of High Temperature and Pressure Conditions on the Combustion Characteristics of n-butanol and n-heptane Fuel)

  • 임영찬;서현규
    • 한국분무공학회지
    • /
    • 제21권1호
    • /
    • pp.29-36
    • /
    • 2016
  • The effect of high ambient temperature and pressure conditions on the combustion performance of n-butanol, n-heptane and its mixing fuel (BH 20) were studied in this work. To reveal this, the closed homogeneous reactor model applied and 1000-1200 K of the initial temperature, 20-30 atm of initial pressure and 1.0 of equivalence ratio were set to numerical analysis. It was found that the results of combustion temperature was increased and the ignition delay was decreased when the ambient conditions were elevated since the combustion reactivity increased at the high ambient conditions. On the contrary, under the low combustion temperature condition, the combustion pressure was more influenced by the ambient temperature in the same ambient conditions. In addition, the total mass and the mass density of tested fuels were influenced by the ambient pressure and temperature. Also, soot generation of mixing fuel was decreased than n-heptane fuel due to the oxygen content of n-butanol fuel.

불티의 성상을 고려한 도시화재 시뮬레이션 개선에 관한 연구 (A Study on the Improvement of Urban Fire Simulation on Firebrand Scattering)

  • 구인혁;서동구;김봉찬;권영진
    • 한국화재소방학회논문지
    • /
    • 제29권5호
    • /
    • pp.67-72
    • /
    • 2015
  • 우리나라는 급속한 경재성장 및 도시화로 인해 도시지역의 건축물이 밀집되어 있다. 이러한 지역에서 화재가 발생할 경우, 강풍에 의한 불티의 비산으로 화재가 확대될 위험성이 존재한다. 하지한 현재 불티의 성상에 대한 모델 구축 및 연구가 부족한 실정이다. 본 연구에서는 일본 건축연구소(BRI)의 풍동 시설을 이용한 불티의 성상 실험을 통하여 비산모델을 구축하고 기존의 도시화재 시뮬레이션을 개선하였다.

철갑소이탄에 의한 전투시스템 내 적재포탄의 순간화재에 관한 전산해석

  • 이승철;전우철;이해평;이헌주
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2013년도 추계학술대회 초록집
    • /
    • pp.208-209
    • /
    • 2013
  • 본 연구에서는 철갑소이탄이 장갑을 관통한 후 전투시스템 내의 적재포탄(고폭탄 또는 추진제)에 피탄되었을 때 순간화재 발생확률에 대해 전산해석을 수행하였다. 장갑은 RHA 재질로 설정하였고, 장갑 두께를 5~30 mm까지 5 mm씩 증가시키며 전산해석을 실시하였다. 고폭탄은 COMPB, TNT, PBX가 사용되었으며 추진제는 ANB가 사용되었다. 본 해석은 Autodyn 프로그램을 사용하였으며, 순간화재 발생 여부를 해석하기 위해 Lee-Tarver ignition and growth model을 사용하였다. 해석 결과, 철갑소이탄이 고폭탄 TNT와 PBX에 피탄되었을 때, 순간화재 발생확률이 모두 100%를 나타내었으며, 고폭탄 COMPB의 경우, 0.8~0.08%로 나타났다. 추진제 ANB의 순간화재 발생확률은 3.8~3.6%로 나타났다.

  • PDF

건물 내장재의 화재위험성 평가 방법 (A Fire Hazard Assessment of Interior Finish Materials)

  • 김운형
    • 한국화재소방학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-28
    • /
    • 1998
  • 건물 화재시 예상되는 내장재의 실째 화재성농올 기준으로 한 위험성 명가방법올 제시하였다. 이률 위해 ISO Room Corner Test. (9705)를 기준으로 Qui ntie re의 화재확산 모델을 이용하여 내장재의 열 적 특성과 플래쉬 오버 도달시간과의 상관성을 유도하고 스쩨덴의 실제 시험결과와 비교 분석하였다. 이 결과, 내장재의 상대척인 화재위험성은 화재확산 변수 b륨 기준으로 명가될 수 있었다.

  • PDF

화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구 (A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests)

  • 최금란
    • 한국안전학회지
    • /
    • 제20권4호
    • /
    • pp.171-179
    • /
    • 2005
  • 건물의 마감재료가 화재에 노출될 때 그 마감재료의 역할을 이해하는 것은 필수적이다. 실물화재실험을 통해서 재료의 성능을 평가하는 것이 가능하다. 그러나 실물화재 실험 시 소요되는 시간과 높은 비용으로 인해 실물 화재 실험이 수행되는 경우는 드물고 대신 컴퓨터 화재 시뮬레이션이 개발되어 왔다. 컴퓨터 화재 시뮬레이션에서는 초기입력 데이터로서 점화 버너의 화염으로부터의 Heat Flux Map이 요구된다. 현재까지의 연구에서는 열전대 혹은 열유속 센서와 같은 실험장치의 제한으로 인해 $10kW/m^2$간격의 Heat Flux Map이 나와있을 뿐이고 공간적으로 더 상세한 Heat Flux Map은 없는 실정이다. 화재 시뮬레이션의 성능을 증가시키기 위해서는 점화 버너로부터의 정확하고 상세한 Heat Flux Map이 필요불가결하다. 본 연구의 목적은 적외선 카메라로부터 얻어진 표면온도를 이용하여 벽에서 점화 버너 화염에 대한 Heat Flux Happing Procedure를 개발하는 것이다. 높은 수준의 공간적 해상도는 적외선 카메라로부터 제공된다. 개발된 Heat Flux Mapping Procedure를 증명하기 위해서 ISO 9705 점화버너를 이용해서 실험이 행해졌다. 실험 결과를 통해 개발된 Heat Flux Mapping방법의 열유속 해상도와 공간적 해상도가 얻어졌다. 또한 그 실험 결과가 현재 쓰여지고 있는 Heat Flux Map과 비교되었다.

운동에너지 탄과 적재포탄에 따른 전투시스템 내부에서의 순간화재발생에 대한 전산해석 (A Numerical Study on the Flash Fire in the Combat System by the Kinetic Energy Ammunition and the Loaded Shells)

  • 이승철;전우철;이해평;이헌주
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.828-832
    • /
    • 2013
  • In this paper, numerical analysis was performed about whether the flash fire of loaded shells breaks out in the virtual combat vehicle according to sorts of the kinetic energy ammunition as the preceding research for vulnerability analysis inside the combat system by an external threaty ammunition. In this simulation, Autodyn program was used and the Lee-Tarver ignition and growth model was used to determine the flash fire outbreak. In this study, the kinetic energy ammunition was set of type A and type B in two kinds and the loaded shells was set of COMPB, TNT, PBX9404 and ANB. As a result, TNT and PBX9404 have much higher flash fire probability than COMPB in high explosive, ANB has very low flash fire probability.

The onset of extreme fire behaviour in a mine drift

  • Hansen, Rickard
    • Geosystem Engineering
    • /
    • 제21권5호
    • /
    • pp.282-290
    • /
    • 2018
  • The onset of extreme fire behaviour in a mine drift with longitudinal ventilation was analysed. A fire in a mine drift with continuous fuel load, involving several separate fires may lead to flames tilted horizontally and filling up the entire cross section. This will lead to earlier ignition, higher fire growth rate, higher fire spread rate and a severe fire behaviour. The focus has been on what changes take place at the onset and signs of the impending phenomenon. It was found that the fire gas temperature at the ceiling level provided a poor indicator. At the downstream far-field region of the fire, the sudden temperature increase at the lowest levels of the cross section and the sudden increase in flow velocities would provide signs of extreme fire behaviour. The corresponding full-scale heat release rates of the experiments at the onset of extreme fire behaviour were found to be very high for mining applications but not necessarily for tunnel fires. The heat release rate threshold for a mine drift with smaller cross-sectional dimensions would decrease considerably, increasing the likelihood of occurrence. The distance between the fuel items will play an important role during the initiation of horizontal flames.

총탄 충격이 가해진 반응 시스템의 파괴 거동에 관한 수치적 연구 (Numerical Simulations of Dynamic Response of Cased Reactive System Subject to Bullet Impact)

  • 김보훈;김민성;도영대;김창기;유지창;여재익
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.525-538
    • /
    • 2014
  • 무기체계 개발에서 예상치 못한 고속의 총탄 충격을 받았을 때 반응 시스템의 폭발 반응을 예측하는 것은 안정성 확보를 위하여 매우 중요하다. 본 연구에서는 LX-17(92.5% TATB, 7.5% Kel-F)과 AP 기반의 고체 추진제(88% AP, 12% HTPB)가 충전된 반응 시스템에 한계 속도로 충돌하는 총탄 충격을 가했을 경우 발생하는 폭굉 현상 및 파괴 거동을 I&G 모델이 적용된 2차원 하이드로 수치해석을 통해 규명하고자 하였다. 해석 결과, LX-17의 경우 충격-폭굉 천이 현상(SDT)이 주요한 메커니즘으로 작용한 반면 고체 추진제는 상대적으로 안정한 모습을 보였다. 즉, 시스템의 파괴는 내부 압력의 급격한 증가와 격렬한 화학반응을 동반하는 고에너지 물질의 폭굉 현상이 그 원인이며, 폭발등급이 낮은 경우에는 고속 충돌에도 발화되지 않아 커버가 완전 파쇄에 이르지 않는 것으로 관찰되었다.

성능기반 화재안전설계를 위한 침실 공간에서의 실화재 실험 (The Real Fire Test in Bedroom for the Performance Based Fire Design)

  • 김형준;권인규;권오상;김흥열;채승언
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.32-37
    • /
    • 2013
  • 건축물에서의 성능기반 화재안전설계를 위해서는 구획 공간 내에서의 화재성장 및 화재크기와 같은 화재특성을 우선적으로 판단하여야 하지만, 건축물에서의 구획공간의 형태, 환기조건 등과 같은 상이한 조건과 실규모 화재실험의 어려움으로 인하여 관련 기초 자료가 부족한 현실이다. 따라서 본 연구에서는 건축물에서의 구획공간에 대한 실규모의 화재 실험을 통해 공학적 화재 특성 데이터인 열방출률 등을 제시하고자 하였다. 실규모의 화재실험은 침실공간으로 설정하였으며, 화재실험은 2.4 (L) ${\times}$ 3.6 (W) ${\times}$ 2.4 (H) m의 구획 모델에서 실시하였다. 초기착화는 쓰레기통에서 발생하였으며, 화재실험은 총 30분에 동안 진행되었다. 화재실험결과, 실험 시작 7분 50초 이후부터 화염이 외부로 출화되었으며, 최대 열방출률은 실험 시작 9분 34초에 3810.6 kW로 측정되었다.