• Title/Summary/Keyword: Identify contamination

Search Result 231, Processing Time 0.031 seconds

Rapid Measurement of VOC Using an Analysis of Soil-Gas (Soil-Gas의 분석을 이용한 휘발성 유기화합물 오염도 신속측정)

  • 김희경;조성용;황경엽
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.3-9
    • /
    • 1998
  • This paper presents soil-gas surveying technique to delineate an area contaminated with volatile organic compounds, which are common solvents and constituents of gasoline. The sampling method of soil-gas surveying is 1) grab sampling, which actively takes sample using a pump, or 2) passive sampling, which takes sample through diffusion in a trap filled with absorbent. The grab sampling shows the level of contamination at a certain location at a certain time, while the passive sampling shows the change in the contamination at a certain location. The analysis of soil gas can be performed with 1) a small portable detectors such as PID (photoionization detector) or FID (flame-ionization detector) to measure the total hydrocarbon in the soil gas, 2) a gas detector tube, which is filled with indicator reagents and changes its color with concentrations of the gas of interest, or 3) a portable GC (gas chromatograph), which can analyze different compounds simultaneously. The soil-gas surveying technique is a much less expensive method to investigate area contaminated volatile organic compounds and thus can be used as a screening tool to identify an area, which needs to be further investigated.

  • PDF

Identification of Jet fuel (JP-8) in Petroleum Hydrocarbon Contaminated Soil through the Qualitative Analysis of Antioxidants (유류 오염 토양 중 산화방지제 정성 분석을 통한 항공유(JP-8) 유종 판별)

  • Kim, Yonghun;Lee, Goontaek;Jang, Hanjeon;Jo, Yunju;Kim, Moongun;Choi, Jaeho;Kang, Jiyoung
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.4
    • /
    • pp.37-48
    • /
    • 2022
  • Accurate analysis of petroleum hydrocarbons in soil is an important prerequisite for proper source tracking of contamination. Identification of petroleum compounds is commonly carried out by peak pattern matching in gas chromatography. However, this method has several technical limitations, especially when the soils underwent biological, physical and chemical transformation. For instance, it is very difficult to distinguish jet fuel (JP-8) from kerosene because JP-8 is derivatized from secondary reaction between chemical agents (e.g. anti-oxidants, antifreezer and so on) and kerosene. In this study, an alternative method to separately analyze JP-8 and kerosene in the petroleum hydrocarbon contaminated soil was proposed. Qualitative analyses were performed for representative phenolic antioxidants [2,6-di-tert-butyl phenol (2,6-DTBP), 2,4-di-tert- butylphenol(2,4-DTBP), 2,6-di-tert-butyl-4-methyl phenol (2,6-DTBMP)] using a two dimensional gas chromatograph mass spectrometer (2D GC×GC-TOF-MS). This qualitative analysis of antioxidants in soil would be a useful complementary tool for the peak pattern matching method to identify JP-8 contamination in soil.

A Study on Airborne Microbes Contamination that Influences on Nosocomial Infection (병원내 감염에 영향을 미치는 공기오염 상태에 대한 조사 연구)

  • 최영희;박정호;윤혜상;문영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.12 no.1
    • /
    • pp.39-52
    • /
    • 1982
  • Nosocomial infection is important in the management of the nursing care and has been found to be related with the airborne microbes contamination. The purpose of this study is to identify the differences of the airborne microbes between hospitals, nursing units, days and times and to identify the difference in the types of microorganisms between hospitals, nursing units, days and times. This study was conducted from May 25, to July 10, 1981, according to R. Koch's methods for quantative samplings of airborne microbes and the results of this study were reviewed in a statistical method. The following conclusions were obtained: 1. There was a significant difference in the types of airborne microbes between 8 hospitals (F=5.0491, p<0.01) 2. There was a significant difference in the types of airborne microbes between surgical, medical, nursery, 1.C.U., operating theatre and outpatient nursing unit. (F=2.1764, p<0.05) 3. There was not a significant difference in the types of airborne microbes between Monday, Thursday and Saturday (F= 1.6365, p>0.05) 4. There was a significant difference in the types of airborne microbes between AM 7 : 00, AM 11:00 and PM 3 : 00. (F=7.2951, p<0.01) 5. 4061 colonies were divided into more 48 types and the classification was as follows. gram positive cocci (2024 colonies) 49.3% gram positive bacillus (1211 colonies) 29.8% gram negative bacillus (577 colonies) 14.2% fungus(200colonies) 4.9% gram negative cocci (41 colonies) 1.0% other's(8 colonies) 0.3% 6. There was a significant difference of airborne microbes between 8 hospitals. (F=7.7943, P<0.01) 7. There was not a significant difference of airborne microbes between 6 nursing units. (F= 1.8461, P>0.05) outpatient nursing unit : 12.6 colonies surgical nursing unit. 10.4 colonies Medical nursing unit : 9.8 colonies nursery nursing unit : 9.4 colonies operating theatre nursing unit:8.2 colonies Intensive care nursing unit : 7.8 colonies 8. There was not a significant difference of airborne microbes between Monday, Thursday and Saturday. (F=1.4371, p>0.05). Saturday : 11.0 colonies Monday : 9.1 colonies Thursday : 9.1 colonies 9. There was a significant difference of airborne microbes between A. M. 7 ; 00, A. M. 11 : 00 and P .M. 3:00 (F=7.6658, p<0.05) P. M. 3 : 00 : 12.2 colonies A. M. 11 : 00 : 10.0 colonies A. M. 7 : 00 : 7.1 colonies.

  • PDF

Hydrogeochemical characteristics of urban groundwater in Seoul

  • Lee, Ju-Hee;Yun, Seong-Taek;Kwon, Jang-Soon;Kim, Dong-Seung;Park, Seong-Sook
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.472-472
    • /
    • 2004
  • Numerous studies on urban groundwater have been carried out in many other countries. Urban groundwater shows a unique hydrologic system because of complex urban characteristics such as road pavement, sewers and public water supply systems. These urban facilities may change the characteristics of groundwater recharge but contaminate its quality as well. There have been several researches on urban groundwater in Seoul. Seoul has been industrialized very rapidly so that the city has large population. The recent population in Seoul amounts to more than ten millions, corresponding to a very high density of about 17, 000 people/km$^2$. Therefore, many factors affect the groundwater quality and quantity in Seoul. Nowadays, groundwater in Seoul is being extracted for construction, industrial use, and drinking and so on. There are 15, 714 wells in Seoul and its annual usage is 41, 425, 977m$^3$(in 2001). Therefore, systematic studies are needed to properly manage and use the groundwater in Seoul. The purposes of this study in progress are to identify geochemical characteristics of groundwater in Seoul and to determine the extent of groundwater contamination and its relationship with urban characteristics. For this study, groundwater was sampled from more than 400 preexisting wells that were randomly selected throughout the Seoul area. For all samples, major cations together with Si, Al, Fe, Pb, Hg For 200 samples among them, TCE, PCE, BTEX were also analyzed by GC. Our study shows that groundwater types of Seoul are distributed broadly from Ca-HCO$_3$ type to Ca-Cl+NO$_3$ type. The latter type indicates anthropogenic contamination. Among cations, Ca is generally high in most samples. In some samples, Na and K are dominant. The dominant anions change widely from HCO$_3$ to Cl+NO$_3$. The anion composition is considered to effectively indicate the contribution of distinct anthropogenic sources. In addition, major ions are positively proportional to total dissolved solid (TDS) except K and NO$_3$. Thus, we consider that TDS may be used as an effective indicator of the extent of pollution. However, the increase of TDS may result from increased water-rock interaction. To determine the extent of groundwater contamination, it is needed to figure out the baseline water quality in Seoul. Furthermore, detailed geochemical studies are required to find out pollution sources and their corresponding hydrochemical parameters.

  • PDF

Systematic Analysis of Microbial Contamination in Leaf and Stem Products in Korea (Systematic analysis 방법을 이용한 국내 엽경채류 농산물의 미생물학적 오염도 분석)

  • Sung, Seung-Mi;Min, Ji-Hyeon;Kim, Hyun Jung;Yoon, Ki-Sun;Lee, Jong-Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.306-313
    • /
    • 2017
  • This study systemically analyzed the data on the microbial levels in fresh vegetables in Korea to identify the points to control. We scanned the studies published between 2001 and 2015 in peer-reviewed research papers on the microbial levels in fresh vegetables produced in Korea. Plant products were categorized by using the US IFSAC (Interagency Food Safety Analytics Collaboration) category. The most consumed, the non-heat treated, the epidemiological foodborne diseases sources of fresh vegetable in foodservice (KCDC data) were identified by literature review. Articles were screened using National Digital Science Library (NDSL) search engine regarding to microbial hazards in plant products. Based on the total plate count number and coliforms on the 89 data cases from 26 published articles, the total plate count number was high in the order of sprouts, leaf and stem, bulbs and roots, vine-grown, solanaceous, melons, and pome. Escherichia coli was frequently detected in leaf and stem and sprouts products. Focused on the microbial data of leek, lettuce and cabbage, the levels of total plate count, coliforms and Bacillus cereus showed the levels of 4.15~7.69 log CFU/g, 1~6.99 log CFU/g, and 0.51~3.9 log CFU/g, respectively, by 33 published papers. The levels of environmental factors affecting the microbial safety of lettuce and leek before harvest were investigated. Manure, soil, hands, scale, gloves were the major potential microbial contamination points to control. In addition, GAP (good agricultural practice), microbial testing, and improvement of irrigation methods are required to provide the safer fresh produce.

Variations of Complex Permittivity due to Water Content and Heavy Metal Contamination (함수비와 중금속 오염도에 따른 유전상수의 변화)

  • Oh Myoun-Hak;Kim Yong-Sung;Yoo Dong-Ju;Park Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.231-241
    • /
    • 2005
  • Laboratory experiments were performed to examine the effects of water content and to see if permittivity had sufficient sensitivity to identify subsurface contamination. Both real and imaginary permittivities of unsaturated sand were strongly governed by the volumetric water content. Especially, a linear relationship between real permittivity and volumetric water content was derived at high frequencies (MHz ranges). Heavy metals in pore fluid result in significant increases in the effective imaginary permittivity, due to ionic conduction, but decreases in the real permittivity arises due to the decreased orientational polarization of water molecules caused by hydration of ions. Clear increase in the effective imaginary permittivity with heavy metal concentration was found to be valuable in the application of electrical methods for detecting heavy metals in the subsurface. However, because the permittivity is primarily dependent on the volumetric water content of soil, pre-evaluation on the volumetric water content is required.

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.

Opportunities for Joint Cooperation in R&D for FEALAC Countries: On Nanotechnology and Biotechnology

  • Trujillo, Ivan Montenegro;Jimenez, Edgar E Gonzalez;Ospina, Monica Botero
    • STI Policy Review
    • /
    • v.7 no.2
    • /
    • pp.106-131
    • /
    • 2016
  • The general purpose of this paper is to identify opportunities for and to measure existing collaboration on research and development between institutions from the countries of Asia and Latin America in FEALAC's framework, in the fields of biotechnology and nanotechnology and their convergence. The methodological approach includes scientific and technological surveillance and research seeking to identify both the R&D and innovation capacities of the countries as well as the degree of international cooperation between countries of the two regions; case studies and a study of the governance framework of international collaboration in R&D about issues considered global challenges. The study has three main findings. First, nanotechnology, biotechnology and their convergence contribute to solving the problem of contamination by heavy metals affecting most of the countries that are part of FEALAC and to address problems arising from the accelerated rate of energy consumption, which also contributes to environmental damage. In this scenario, important business opportunities arise from the adaptation and development of bio-refinery technologies. Second, the scientific relationship between FEALAC countries, mainly between Asian and Latin American countries, is weak as can be seen in research for articles and patents. But there is plenty of room and potential for improvement. Third, current and upcoming joint R&D programs and projects should be linked both to existing governance structures and to new ones that serve as experiments of STI public policy regarding innovative management of intellectual property and capacity building. Practical implications are included in lessons learned and a set of recommendations involving a couple of proposals. One proposal calls for research and innovation in promising fields for international cooperation. Another proposal creates mechanisms in the governance framework for sharing knowledge, capacity building, and funding.

Identification of Bacterial Strains Adhered to Dog Hair and Antibacterial Effects of Scutellaria baicalensis Gorgi (애완견의 털에 부착되어 있는 세균의 분리 및 황금의 살균효과)

  • Cho In-Kyung;Han Hyo-Shim
    • Korean Journal of Plant Resources
    • /
    • v.18 no.1
    • /
    • pp.198-206
    • /
    • 2005
  • This study was carried out to identify bacterial strains adhered to domestic pet dog hair and to identify antibacterial extracts from natural compounds. A total of 76 strains were isolated from dog hair. The most common species isolated was Staphylococcus spp. (41 isolates), followed by Micrococcus spp. (21 isolates), Enterococcus spp. (8 isolates), Bacillus sup. (3 isolates), Exiguobacterium sup. (2 isolates), Shigella spp. (1 isolate) and Zoogloea spp. (1 isolate). These results suggested that dog hair could be a source of bacterial contamination to human. The susceptibility of isolates to antibiotics and antibacterial activities of the natural compounds were examined by disk diffusion method. Water and ethanol extract from Scutellaria baicalensis revealed high antibacterial activities against Staphylococcus, Micrococcus, Enterococcus and Shigella. Our results suggest that the extract of Scutellaria baicalensis can be used a antibacterial agent against the antibiotic-resistant microorganisms.

An Algorithm for Searching On-Off Valves to Isolate a Subsystem in a Water Distribution System (상수관망의 부분적 차폐를 위해 필요한 제수밸브 결정 알고리즘)

  • Jun, hwan-don;Park, moo-jong;Lee, jong-seok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.771-775
    • /
    • 2008
  • Concerns related to protecting, identifying, and isolating of subsystems of a water distribution network have led to the realization of the increased importance of valves in the system. The most important purpose of valves in water distribution systems is to isolate subsystems due to breakage, maintenance activities, or contamination. A subsystem called segment is isolated by the closure of adjacent valves and an efficient algorithm should identify the adjacent valves to minimize the pipe failure impact. In this paper, an algorithm to identify adjacent valves to be closed to isolate a subsystem from the remainder of a network in case of a pipe failure is presented. An application to the water distribution system in Ottawa, Canada demonstrates the developed algorithm efficiently locates the adjacent valves for the isolation of a broken pipe.

  • PDF