• Title/Summary/Keyword: Icp

Search Result 2,338, Processing Time 0.049 seconds

Monitoring of hazardous heavy metals in circulated collagen products in Korea (유통 콜라겐 제품 중 유해중금속 함량 모니터링)

  • Ji-Eun, Kim;Beom-Ho, Kim;Kyung-A, Kim;Dae-Hwan, Kim;Young-Ju, Choi;Hyo-Jung, Kang;Ji-Hyeon, Min;Myung-Jin, Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.6
    • /
    • pp.394-399
    • /
    • 2022
  • This study was conducted to estimate hazardous heavy metal content, including lead (Pb), cadmium (Cd), arsenic (As) and mercury (Hg) in 120 collagen products currently marketed in Korea. Hg concentration was analyzed by a gold amalgamation method using a mercury analyzer, while concentrations of Pb, Cd, and As were analyzed by ICP-OES. The average Pb concentration was 0.097 mg/kg. For comparison, respective average concentrations were 0.108 mg/kg, 0.084 mg/kg, 0.131 mg/kg, and 0.149 mg/kg in functional health foods, other processed products, beverages, and fruit/vegetable processed products. The average concentration of Cd was 0.026 mg/kg. All products in which Cd was detected were functional health foods. The average concentration of As was 0.097 mg/kg, with respective average concentrations of 0.091 mg/kg, 0.133 mg/kg, and 0.086 mg/kg in functional health foods, other processed products, and fruit/vegetable processed products. The average Hg concentration was 0.0025 mg/kg, with respective average concentrations of 0.0012 mg/kg, 0.0028 mg/kg, 0.0013 mg/kg, and 0.0031 mg/kg in functional health foods, other processed products, fruit/vegetable processed products, and candies respectively. Heavy metal levels in beverages and candy products with set heavy metal standards were below the set standards. Even products without regulatory standards were found to be relatively safe compared with heavy metal standards set for domestic and foreign foods.

Risk Assessment of Heavy Metals Migrated from Plastic Food Utensils, Containers, and Packaging Distributed in Korea (국내 유통 식품용 플라스틱 기구 및 용기, 포장의 중금속 위해도 평가)

  • Kyung Youn, Lee;Hyung Soo, Kim;Dae Yong, Jang;Ye Ji, Koo;Seung Ha, Lee;Hye Bin, Yeo;Ji Su, Yoon;Kyung-Min, Lim;Jaeyun, Choi
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.175-182
    • /
    • 2022
  • Heavy metals can be intentionally or unintentionally introduced into plastic food utensils, containers, and packaging (PFUCP) as additives or contaminants, which can be ingested with food by humans. Here, seven-heavy metals (lead, cadmium, nickel, chromium, antimony, copper, and manganese) with toxicity concerns were selected, and risk assessment was done by establishing their migration from 137 PFUCP products made of 16 materials distributed in Korea. Migration of heavy metals was examined by applying 4% acetic acid as a food simulant (70℃, 30 minutes) to the PFUCP products. Inductively coupled plasma mass spectrometry (ICP-MS) was employed for the analysis of migrated heavy metals, and the reliability of quantitative results was confirmed by checking linearity, LOD, LOQ, recovery, precision, and expanded uncertainty. As a result of monitoring, heavy metals were detected at a level of non-detection to 8.76 ± 11.87 ㎍/L and most of the heavy metals investigated were only detected at trace amounts of less than 1 ㎍/L on average. However, antimony migrated from PET products was significantly higher than other groups. Risk assessment revealed that all the heavy metals investigated were safe with a margin of exposure above 311. Collectively, we demonstrated that heavy metals migrated from PFUCP products distributed in Korea appear to be within the safe range.

Hazardous Metal Content in Tattoo Cosmetics and Tattoo Inks (타투화장품 및 문신용 염료의 유해금속 함량 연구)

  • Mi Sun Kim;Su Un Kim;Sam Ju Jung;Young Eun Kim;Min Jung Kim;Myung Sook Lee;In Sook Hwang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.66-77
    • /
    • 2023
  • Background: Along with the increase in consumer interest in and consumption of tattoo products, the controversy over harmful heavy metals associated with the use of tattoo cosmetics is also increasing. Therefore, investigation of hazardous metals in these tattoo products is needed. Objectives: This study was performed to provide useful data for establishing reasonable standards to securely manage tattoo cosmetics, tattoo stickers, and tattoo inks distributed in the market. Methods: Thirteen kinds of hazardous metal contents (Pb, As, Cd, Sb, Ni, Co, Cu, Cr, Se, Ba, Zn, Sn, and Hg) were analyzed for 23 tattoo cosmetics, ten tattoo stickers, and 16 tattoo inks. Hg was measured through the combustion-gold amalgamation method, and other hazardous metals were measured by inductively coupled plasma-mass spectrometry (ICP-MS) after acidic decomposition using a microwave apparatus. Results: The detected ranges of Pb, As, Cd, Sb, Ni, and Hg in tattoo cosmetics were 0.07~1.18, 0.06~0.41, ND~0.07, 0.01~3.44, 0.12~2.75, and ND~0.01 ㎍/g, respectively. All of the hazardous metals detected were below the recommended maximum standards of the Ministry of Food and Drug Safety. The mean amount of Pb detected in tattoo stickers for children was 0.24 ㎍/kg and Cd was not detected, meaning both metals met the recommended criteria. There was no statistically significant difference in all measured metals between children's tattoo stickers and adults' tattoo stickers. In the results of the study on the hazardous metal content of tattoo inks, four products (25%) for Pb, one product (6%) for As, 13 products (81%) for Ni, four products (25%) for Cu, and five products (31%) for Zn exceeded the recommended standards approved by the government. The highest predicted exposure amount for hazardous metals exceeding the recommended level of tattoo inks in a single tattooing was 5.69 ㎍/kg for Ni, 8.51 ㎍/kg for Zn, 0.44 ㎍/kg for Pb, 8.07 ㎍/kg for Cu, 0.44 ㎍/kg for As, and 71.36 ㎍/kg for Ba. Conclusions: It is necessary to prepare criteria for content limitation for the management of Co, Cr, Ba and Se tattoo cosmetics, and tattoo inks require thorough quality control.

Investigation of Heavy Metal Migration from Food Contact Materials used for Food Delivery Using an Inductively Coupled Plasma-Mass Spectrometer

  • Chae-Yeon Hwang;Young-Jun Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.2
    • /
    • pp.37-45
    • /
    • 2023
  • The surge in food delivery systems during the coronavirus 2019 pandemic necessitated this study of heavy metal migration from food contact materials (FCMs). A total of 104 samples of FCMs, comprising 51 polypropylene (PP), 21 polyethylene (PE), and 32 polystyrene (PS) samples of six different types of FCMs (containers, covers, table utensils, cups, pouches, and wrappers) used for food delivery distributed in Korea, were collected and investigated for migration of three heavy metals (Pb, Cd, and As) using inductively coupled plasma-mass spectrometry (ICP-MS) to determine whether they complied with Korea's Standards and Specifications for Utensils, Containers, and Packages. Acetic acid (4%, v/v) was used as the food simulant, and tests were performed at 100℃ (in harsh conditions) for 30 min. Linearity of Pb, Cd, and As showed acceptable results with a coefficient of determination (R2) value of 0.9999. Limit of detection (LOD) and limit of quantification (LOQ) of Pb, Cd, and As were 0.001, 0.001, and 0.001 ㎍/L and 0.002, 0.003, and 0.003 ㎍/L, respectively. Accuracy and precision results complied with the criteria presented in the European Commission Joint Research Centre guidelines. The average concentration of Pb, Cd, and As migration detected in a total of 104 samples was 0.009-0.260 ㎍/L, which was very low compared with the migration specification set in the Standards and Specifications for Utensils, Containers, and Packages. The maximum level of Pb corresponded to 0.23% of the migration limit. There were no samples exceeding the limit. Thus, this study confirmed that the heavy metal contents of FCMs used for delivery food distributed in Korea were safely managed. The data from this study represent an invaluable source for science-based safety management of hazardous heavy metals migrating from FCMs used in the food delivery industry.

Contents of mercury, lead, cadmium, and arsenic in dried marine products (건포류의 수은, 납, 카드뮴 및 비소 함유량)

  • Ok, Hwang Young;Kim, Su Un;Ryu, Seung Hee;Ham, Hee Jin;Park, Gun Yong;Park, Seog Gee
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.336-344
    • /
    • 2009
  • This survey was carried out to estimate the contents of heavy metals (Hg, Pb, Cd, and As) in 10 kinds of dried marine products (n=189) which are closely related to food resources. The contents of heavy metals were estimated by inductively coupled plasma spectrometer (ICP) and mercury analyzer. The values of heavy metals in dried marine products were as follows (Mean${\pm}$SD (range), mg/kg). The average contents of heavy metals in the dried marine products were Hg $0.058{\pm}0.069$ (0.002~0.502) mg/kg, Pb $0.178{\pm}0.598$ (ND~5.130) mg/kg, Cd $0.306{\pm}0.610$ (ND~6.802) mg/kg, As $5.282{\pm}6.158$ (ND~71.760) mg/kg. The range of heavy metal contents in dried marine products are low level, except of lead contents (n=2). In the comparison of heavy metal content by anchovy size, it was shown that cadmium, mercury and arsenic were meaningfully different. The contents of heavy metals by the shape of shrimp and Alaska Pollack were shown that the result of each group was meaningless. In the comparison imported production with domestic production, in the case of common squid, cadmium and arsenic were meaningfully different. The weekly average intakes of Hg, Pb and Cd from dried marine products takes about 1.17~11.52% of PTWI (Provisional Tolerable Weekly Intakes) that FAO/WHO Joint Food Additive and Contaminants Committee has set to evaluate their safeties.

The content and risk assessment of heavy metals in commercial herbal medicines (서울지역 유통한약재의 중금속 함량 및 위해성 평가)

  • Young Shin;Sang-Hun Park;Seung-Hye Han;So-Hyun Park;Ji-Hye Kim;Hyun-Jung Jang;Ae-Kyoung Kim;Ju-Seung Park
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.267-280
    • /
    • 2023
  • This study investigated the contents of Pb, Cd, As, and Hg for 4333 samples with 2 09 types of herbal medicines distributed in Seoul area from 2019 to 2021, and evaluated risk assessment according to medicinal part used and origin. The contents of heavy metals were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) and mercury analyzer. The average contents (mg/kg) of heavy metals by medicinal parts were 0.123 to 1.290 for Pb, 0.018 to 0.131 for Cd, 0.034 to 0.290 for As, and 0.003 to 0.015 for Hg. The contents of Pb were higher in Leaves and Whole Herbs (above-ground part) than underground part (Radix & Rhizoma) (ANOVA-test, p < 0.05). The contents of Cd were high in Leaves, Radix & Rhizoma, and Stems & Woods (ANOVA-test, p <0 .05), and exceeded regulatory limits in various types. Levels of Pb, Cd concentrations exceeding regulatory limits were observed in 8, 22 samples (8, 14 types). No sample exceeded regulatory limits of As and Hg. In the comparison between countries of origin, the contents of Cd, As, and Hg were high in imported herbal medicines (t-test, p < 0.05). As a result of the risk assessment, except for Thujae Orientalis Folium and Spirodelae Herba, the MOE values of Pb were all 1 or more, and most samples were safe. The Hazard Index (HI) for Cd, As, and Hg were evaluated to be less than 100 % even if the risk (%) of each heavy metal was added, and the risk from taking herbal medicines was evaluated to be safe.

Sources Identification of Anthropogenic Pb in Ulleung Basin Sediments using Stable Pb Isotope Ratios, East/Japan Sea (동해 울릉분지 시추 퇴적물에서 안정 Pb 동위원소를 이용한 Pb의 기원 추정)

  • Choi, Man-Sik;Uoo, Jun-Sik;Kim, Dong-Seon
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.4
    • /
    • pp.315-327
    • /
    • 2007
  • This study investigated temporal and spatial variation of Pb and stable Pb isotopes accumulated in Ulleung Basin core sediments (4) using MC ICP/MS in order to identify the sources of anthropogenic Pb in the East/Japan Sea. Leached (1M HCl) Pb concentration and isotope ratios ($^{207}Pb/^{206}Pb\;and\;^{208}Pb/^{206}Pb$) were nearly constant during 300 yrs past than 1930, but increased up to twice in concentration and as much as 3.41% (1.70%) after 2000. On the other hand, residual Pb concentrations were nearly constant for past 400 yrs. The accumulation rates of anthropogenic Pb in the basin area were in the range of $3.1-3.5mg/m^2/yr$, which were similar levels to total atmospheric Pb deposition fluxes from 1990s to the present. In the slope area, more increase of anthropogenic Pb accumulation than the levels expected from mass accumulation rate could be found after the middle of 1990s. From the detailed evaluation for the temporal and spatial variation of accumulation rate and isotope ratios of anthropogenic Pb, we proposed probable sources and pathways of anthropogenic Pb. Pb emmision by coal burning from the China and Korea initiated the accumulation of anthropogenic Pb in the sediments of East/Japan Sea from 1930s. The accumulation of Pb increased by the addition of anti-nocking agents from both countries untill the beginning of 1990s, but from the middle of 1990s to the present, the phase-out of gasoline additives and the rapid increase of coal burning from the China maintained the atmospheric Pb levels in the Ulleung basin nearly similar to before. However, the local sources within this basin might take an important role in the rapid increase of anthropogenic Pb accumulation in slope areas from the middle of 1990s.

The Content of Minerals and Vitamins in Commercial Beverages and Liquid Teas (유통음료 및 액상차 중의 비타민과 미네랄 함량)

  • Shin, Young;Kim, Sung-Dan;Kim, Bog-Soon;Yun, Eun-Sun;Chang, Min-Su;Jung, Sun-Ok;Lee, Yong-Cheol;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.322-329
    • /
    • 2011
  • This study was done to analyze the contents of minerals and vitamins to compare the measured values of minerals, vitamins with labeled values of them in food labeling and to investigate the ratio of measured values to labeled values in 437 specimen with minerals and vitamins - fortified commercial beverages and liquid teas. Content of calcium and sodium in samples after microwave digestion was analyzed with an ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometer) and vitamins were determined using by HPLC (High Performance Liquid Chromatography). The measured values of calcium were ranged 80.3~142.6% of the labeled values in 21 samples composed calcium - fortified commercial beverages and liquid teas. In case of sodium, measured values were investigated 33.9~48.5% of the labeled values in 21 sports beverages. The measured values of vitamin C, vitamin $B_2$ and niacin were ranged 99.7~2003.6, 81.1~336.7, 90.7~393.2% of the labeled values in vitamins - fortified commercial beverages and liquid teas, 57, 12, 11 samples. To support achievement of the accurate nutrition label, there must be program and initiatives for better understanding and guidances on food labelling and nutrition for food manufacture.

A Study on Corrosion according to Distance between Amalgam and Dissimilar Metals (아말감과 이종(異種)금속의 거리에 따른 부식에 대한 고찰)

  • Kim, Ju-won;Jeong, Eun-gyeong
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.103-109
    • /
    • 2004
  • The present study prepared 72 test samples - 24 made of amalgam alloy, 24 of Verabond (Ni-Cr alloy) for crown and 24 of Talladium $^{TM}alloy$ for denture - according to the manufacturers' manuals and general method in consideration of the width of the mesial-distal dental crown of the lower $1^{st}$ molar and MOD cavity in clinics, put them in a 200 ml beaker containing 80 ml of artificial saliva, and measured their galvanic corrosion at distances of 0 mm, 7 mm and 40 mm after 7 days. Isolated metals in the electrolyte such as Cu, Ag, Ni, Cr, Sn, Zn and Hg were quantitatively analyzed with Inductively Coupled Plasma - Atomic Emission Spectrometer (ICP-AES, JY-50P, VG Elemental Co. France), and from the results were drawn conclusions as follows. First, Cu, Sn, Ag, Hg and Zn were highly advantageous when amalgam contacted gold alloy compared to Ni-Cr alloy for crown and Talladium alloy for denture. In addition, although gold alloy was finest in terms of oral tissue and biocompatibility, it was most disadvantageous when it was with amalgam. Second, when amalgam contacted gold alloy, heavy metals such as Ni and Cr were not isolated at all because gold alloy did not contain such elements but Sn was isolated as much as $227.1{\pm}18.0035{\mu}g/cm^2$ although it was not included in the composition either. Hg was also isolated. These elements are assumed to have been isolated from amalgam itself. Third, when amalgam alloy was apart from gold alloy 0 mm, 7 mm and 40 mm, Cu and Ag showed significance but Hg did not. This suggests that gold alloy must not be used together with amalgam, and must not be used between dissimilar prostheses regardless of distance. Fourth, when amalgam alloy contacted Ni-Cr alloy for crown, Ag was not isolated from the amalgam, but Zn, Ni, Sn, Hg and Cu were isolated in order of quantity. Significance was observed according to distance - 0 mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Ni-Cr alloy for crown, the isolation Hg was less than that when amalgam alloy contacted Ni-Cr alloy for crown. Fifth, when amalgam alloy contacted Talladium alloy for denture, significance was observed at distances of 0mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Talladium alloy for denture, the isolation Hg was less than that when amalgam alloy contacted Talladium alloy for denture. Sixth, according to the result of ICPES test on Cu, Sn, Ag, Hg, Zn, Ni and Cr of amalgam alloy, gold ally, Verabond and Talladium alloy when these alloys contacted artificial saliva, significance was observed in Cu and Hg. Seventh, when amalgam alloy contracted two non-precious metals Ni-Cr alloy for crown and Talladium alloy for denture in artificial saliva, significance was observed in the isolated by-products of Hg, Ni and Cr according to distance.

  • PDF

The Monitoring on Plasticizers and Heavy Metals in Teabags (침출용 티백 포장재의 안전성에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Kang, Kil-Jin;Jeon, Dae-Hoon;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Hee-Jung;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • Nowadays the teabag is worldwide used for various products including green tea, tea, coffee, etc. since it is convenient for use. In case of outer packaging printed, however, there is a possibility that the plasticizers which is used for improvement in adhesiveness of printing ink may shift to inner tea bag. In this study, in order to monitor residual levels of plasticizers in teabags, we have established the simultaneous analysis method of 9 phthalates and 7 adipates plasticizers using gas chromatography (GC). These compounds were also confirmed using gas chromatography-mass spectrometry (GC-MSD). The recoveries of plasticizers analyzed by GC ranged from 82.7% to 104.6% with coefficient of variation of $0.6\sim2.7%$ and the correlation coefficients of each plasticizer was $0.9991\sim0.9999$. Therefore this simultaneous analysis method was showed excellent reproducibility and linearity. And limit of detection (LOD) and limit of quantitation (LOQ) on individual plasticizer were $0.1\sim3.5\;ppm\;and\;0.3\sim11.5\;ppm$ respectively. When 143 commercial products of teabag were monitored, no plasticizers analysed were detected in filter of teabag products. The migration into $95^{\circ}C$ water as food was also examined and the 16 plasticizers are not detected. In addition we carried out analysis of heavy metals, lead (Pb), cadmium (Cd), arsenic (As) and aluminum (Al) in teabag filters using ICP/AES. $Trace\sim23{\mu}g$ Pb per teabag and $0.6\sim1718{\mu}g$ Al per teabag were detected in materials of samples and Cd and As are detected less than LOQ (0.05 ppm). The migration levels of Pb and Al from teabag filter to $95^{\circ}C$ water were upto $11.5{\mu}g\;and\;20.8{\mu}g$ per teabag, respectively and Cd and As were not detected in exudate water of all samples. Collectively, these results suggest that there is no safety concern from using teabag filter.