• Title/Summary/Keyword: Icp

Search Result 2,332, Processing Time 0.026 seconds

LA-ICP-MS U-Pb Zircon Age of the Granite Gneiss from Jeungsan-Pyeongwon Area of North Korea (북한 증산-평원지역 화강편마암의 LA-ICP-MS U-Pb 저콘 연대)

  • Song, Yong-Sun;Park, Kye-Hun;Lee, Ho-Sun;Lin, Cao;Yuji, Orihashi
    • The Journal of the Petrological Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.171-179
    • /
    • 2009
  • LA-ICP-MS U-Pb zircon age was determined from the granite gneiss from Jeungsan-Pyeongwon area located to the west of Pyeongan Basin, North Korea, yielding concordant age of $1,873{\pm}19(2{\sigma})$Ma interpreted as Paleoproterozoic granitic magmatism. Considering relatively precise data reported recently using SHRIMP and LA-ICP-MS, ages around 1,870 Ma have been most frequently reported from Precambrian basement rocks of Korean peninsula, including Yeongnam, Gyeonggi, and Nangnim massifs altogether. Geologic events of this period are interpreted as not only granitic magmatism but also hightemperature regional metamorphism depending on their localities. The magmatic and regional metamorphic events of similar periods have also been reported from neighboring cratons of both North China and South China. Therefore, we need more data and efforts to decipher correlation between Precambrian basements between Korea and China.

Dry Etching of GaAs in a Planar Inductively Coupled BCl3 Plasma (BCl3 평판형 유도결합 플라즈마를 이용한 GaAs 건식식각)

  • Lim, Wan-tea;Baek, In-kyoo;Jung, Pil-gu;Lee, Je-won;Cho, Guan-Sik;Lee, Joo-In;Cho, Kuk-San;Pearton, S.J.
    • Korean Journal of Materials Research
    • /
    • v.13 no.4
    • /
    • pp.266-270
    • /
    • 2003
  • We studied BCl$_3$ dry etching of GaAs in a planar inductively coupled plasma system. The investigated process parameters were planar ICP source power, chamber pressure, RIE chuck power and gas flow rate. The ICP source power was varied from 0 to 500 W. Chamber pressure, RIE chuck power and gas flow rate were controlled from 5 to 15 mTorr, 0 to 150 W and 10 to 40 sccm, respectively. We found that a process condition at 20 sccm $BCl_3$ 300 W ICP, 100 W RIE and 7.5 mTorr chamber pressure gave an excellent etch result. The etched GaAs feature depicted extremely smooth surface (RMS roughness < 1 nm), vertical sidewall, relatively fast etch rate (> $3000\AA$/min) and good selectivity to a photoresist (> 3 : 1). XPS study indicated a very clean surface of the material after dry etching of GaAs. We also noticed that our planar ICP source was successfully ignited both with and without RIE chuck power, which was generally not the case with a typical cylindrical ICP source, where assistance of RIE chuck power was required for turning on a plasma and maintaining it. It demonstrated that the planar ICP source could be a very versatile tool for advanced dry etching of damage-sensitive compound semiconductors.

SEM-EDS and ICP-AES Analysis of Common Food Additives (보통의 식품첨가제의 SEM-EDS와 ICP-AES 분석)

  • Hussain, Raja Azadar;Yasmin, Farida;Nawaz, Hamid;Badshah, Amin
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.551-555
    • /
    • 2010
  • Cinnamomum Iners (Darchini, 쟈 바 계피), Elettaria Cardamomum (Elachi, 백두구, 소두구, 카다몬, 카도몬), Punica Granatum (Anar Dana, 석류), Curcuma Longa (Haldi, 터메릭, 투메릭, 심황, 울금, 울금은, 컬쿠마), Piper Nigrum (Kali Mirch, 페퍼, 페퍼블랙, 후추, 블랙 페퍼), Syzygium aromaticum (Loung, 클로브, 정향, 정향나무,), Capsicum Annum (Laal Mirch, Red Pepper), Mentha Arvensis (Pahari Podina), Curcuma Zedoaria (Kachur, 가쥬츠, 봉출, 아출, 커큐머 제도) Zingiber officinale (Adrak, 건강, 생강, 진저) and Garam Masala (Hot Spice, a mixture) have been analyzed in the present work for their metallic components with the help of SEM-EDS and ICP-AES. Minor concentrations have been determined with ICP-AES and major concentrations with the help of SEM-EDS.

Automatic Registration Method for Multiple 3D Range Data Sets (다중 3차원 거리정보 데이타의 자동 정합 방법)

  • 김상훈;조청운;홍현기
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1239-1246
    • /
    • 2003
  • Registration is the process aligning the range data sets from different views in a common coordinate system. In order to achieve a complete 3D model, we need to refine the data sets after coarse registration. One of the most popular refinery techniques is the iterative closest point (ICP) algorithm, which starts with pre-estimated overlapping regions. This paper presents an improved ICP algorithm that can automatically register multiple 3D data sets from unknown viewpoints. The sensor projection that represents the mapping of the 3D data into its associated range image is used to determine the overlapping region of two range data sets. By combining ICP algorithm with the sensor projection constraint, we can make an automatic registration of multiple 3D sets without pre-procedures that are prone to errors and any mechanical positioning device or manual assistance. The experimental results showed better performance of the proposed method on a couple of 3D data sets than previous methods.

Comparison of analytical methods for quantifying total chromium in soil using Atomic Absorption Spectrometer (AAS) and Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) (토양 시료 중 Atomic Absorption Spectrometry (AAS) 및 Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)를 이용한 총 크롬 분석방법 비교)

  • Lee, Hong-gil;Kim, Ji-in;Byun, Yoonjoo;Kim, Hyunkoo;Yoon, Jeong Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.6
    • /
    • pp.22-28
    • /
    • 2017
  • The accuracy of analytical results in response to the use of different additives ($NH_4Cl$, KCl, $LaCl_3$) and oxidant gases was evaluated and compared by using Atomic Absorption Spectrometry (AAS). Identification of spectroscopic interferences and possible improvements in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) analysis were also discussed. The average accuracies of total chromium using Certified Reference Materials (CRMs) were found to be 72.1~94.2% in air/acetylene flame condition by AAS, and they were improved to 100.5~110.5% when the oxidants was changed to nitrous oxide rather than adding the additives. The field samples showed similar trends to CRMs, but chromium concentrations were highly variable depending on analytical conditions. The average accuracies using CRMs were estimated to be 89.3~166.1% by ICP-AES, and improved to below 121.7% after eliminating iron interference. Field samples with low chromium and high iron concentration were measured to be > 30% lower in total chromium concentrations by ICP-AES than AAS in nitrous oxide/acetylene flame. Total chromium concentrations in soil could be analyzed with better accuracy under nitrous oxide/acetylene flame by AAS because it was more effective to increase the temperature of the flame than to eliminate the chemical interference for maximizing atomization of chromium. When using ICP-AES, interference substances, total chromium levels, and analytical conditions should be also considered.

Effect of HTE001, an Herbal Formulation, on Electric Stimulation-induced Penile Erection in Rats (전기 자극으로 유발한 음경 발기력 측정 흰쥐 모델에 대한 HTE001의 발기력 상승효과)

  • Lim, Dong-Wook;Lee, Dong-Hun;Song, Mi-Kyoung;Kim, Mi-Yeon;Bu, Young-Min;Kim, Ho-Cheol
    • The Korea Journal of Herbology
    • /
    • v.24 no.3
    • /
    • pp.139-146
    • /
    • 2009
  • Objectives : This study was conducted to investigate the effect of HTE001, a multi-herbal mixture consisting of 10 herbs, Cornus Frutus, Schizandrae Fructus, Rubi Fructus, Cnidi Fructus, Acanthopanacis senticosi Radix, Cinnamomi Cortex, Eucommiae Cortex, Allii Bulbus, Rehmanniae Radix and Ginseng Radix, on electrostimulation-induced penile erection in rats. Methods : Intracavernous pressure (ICP) and mean arterial blood pressure (MAP) were simultaneously monitored through electric stimulation of the cavernous nerve after the oral administration of HTE001 (30, 100, 300 mg/kg) in normal rats. Statistical analysis was performed on maximal intracavernous pressure (ICP), maximal intracavernous pressure/mean arterial blood pressure (ICP/MAP) ratio, and the area under the curve (AUC) of ICP/MAP ratio. Results : Oral administration of HTE001 300 mg/kg caused the ICP to increase in a frequency-dependent manner. And HTE001 300 mg/kg treatment group showed the highest value in the ICP/MAP ratio and the AUC value of the ICP/MAP ratio compared to the control group at 2 Hz, 6 Hz and 10 Hz, respectively without an effect on the mean arterial blood pressure under the same stimulation of the cavernous nerve. Conclusions : These results show that HTE001 improve penile erection and prolong the decay period in normal rats without affecting mean arterial blood pressure, and suggest that HTE001 could be a good therapeutic candidate to treat erectile dysfunction.

Comparison of Human Blood Cadmium Concentrations using Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교)

  • Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kang, Min-Kyung;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.491-501
    • /
    • 2018
  • Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: $0.000{\mu}g/L$, MDL: $0.06{\mu}g/L$) was lower than that of GF-AAS (IDL: $0.085{\mu}g/L$, MDL: $0.327{\mu}g/L$). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ${\pm}30%$ of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

Compare the Intracranial Pressure Trend after the Decompressive Craniectomy between Massive Intracerebral Hemorrhagic and Major Ischemic Stroke Patients

  • Huh, Joon;Yang, Seo-Yeon;Huh, Han-Yong;Ahn, Jae-Kun;Cho, Kwang-Wook;Kim, Young-Woo;Kim, Sung-Lim;Kim, Jong-Tae;Yoo, Do-Sung;Park, Hae-Kwan;Ji, Cheol
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.42-50
    • /
    • 2018
  • Objective : Massive intracerebral hemorrhage (ICH) and major infarction (MI) are devastating cerebral vascular diseases. Decompression craniectomy (DC) is a common treatment approach for these diseases and acceptable clinical results have been reported. Author experienced the postoperative intracranaial pressure (ICP) trend is somewhat different between the ICH and MI patients. In this study, we compare the ICP trend following DC and evaluate the clinical significance. Methods : One hundred forty-three patients who underwent DC following massive ICH (81 cases) or MI (62 cases) were analyzed retrospectively. The mean age was $56.3{\pm}14.3$ (median=57, male : female=89 : 54). DC was applied using consistent criteria in both diseases patients; Glasgow coma scale (GCS) score less than 8 and a midline shift more than 6 mm on brain computed tomography. In all patients, ventricular puncture was done before the DC and ICP trends were monitored during and after the surgery. Outcome comparisons included the ictus to operation time (OP-time), postoperative ICP trend, favorable outcomes and mortality. Results : Initial GCS (p=0.364) and initial ventricular ICP (p=0.783) were similar among the ICH and MI patients. The postoperative ICP of ICH patients were drop rapidly and maintained within physiological range if greater than 80% of the hematoma was removed. While in MI patients, the postoperative ICP were not drop rapidly and maintained above the physiologic range (MI=18.8 vs. ICH=13.6 mmHg, p=0.000). The OP-times were faster in ICH patients (ICH=7.3 vs. MI=40.9 hours, p=0.000) and the mortality rate was higher in MI patients (MI=37.1% vs. ICH=17.3%, p=0.007). Conclusion : The results of this study suggest that if greater than 80% of the hematoma was removed in ICH patients, the postoperative ICP rarely over the physiologic range. But in MI patients, the postoperative ICP was above the physiologic range for several days after the DC. Authors propose that DC is no need for the massive ICH patient if a significant portion of their hematoma is removed. But DC might be essential to improve the MI patients' outcome and timely treatment decision.

Effects of the Selective Management for Increased Intracranial Pressure with Obstruction of Internal Carotid Artery in Rabbits (선택적 뇌압하강치료가 내경동맥 폐쇄에 따른 뇌압변동에 미치는 효과)

  • Kim, Bum-Dae;Lee, Kyoung-Yeob;Kim, Seong-Ho;Han, Dong-Ro;Bae, Jang-Ho;Kim, Oh-Lyong;Choi, Byung-Yearn;Cho, Soo-Ho;Shin, Hyun-Jin
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.167-180
    • /
    • 1994
  • In order to inquire the most effective management of increased intracranial pressure(ICP), mannitol, steroid and hyperventilation were used in rabbits after ligation or non-ligation of the carotid artery. Mannitol was more effective than steroid and hyperventilation in the degree of the reduction of ICP. The intracranial pressure was decreased 43~45% for 25~30 minutes after injection of mannitol. Steroid was less effective than mannitol in the degree of the reduction of ICP. But the time of reduction of ICP was longer, that is, the degree of reduction was 24~60 minutes after injection of steroid. Hyperventilation is effective in the initial time only, for 10 minutes after hyperventilation. The degree of ICP reduction was 13.5~16.7% for 10 minutes after hyperventilation. The combined group, that is three kinds of mangenent were used, is the most effective treatment to reduce ICP of ICP. The degree of the reduction of ICP was 42.1~49.3% for 20 minutes, 47.7~52.5% for 30minnutes. There was no significant difference between ligation and non-ligation group.

  • PDF

Characteristic Effects of Dangnyo-hwan for Diabetes Control Studied Using LC-MS/MS and ICP (LC-MS/MS 및 ICP를 이용한 당뇨환의 화학적 특성 분석)

  • In, Jeong-do;Im, Dai-sig;Moon, Seung-ho;Ki, Won-ill
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.217-227
    • /
    • 2015
  • Objectives: The primary aim of this study was to identify bioactive compounds in Dangnyo-hwan, a Korean herbal medicine, through instrumental analysis using LC-MS/MS and ICP, and investigate its potential use in diabetes treatment. Methods: The extract of Dangnyo-hwan has 12 medicinal herbs; these were compared with 18 marker substances selected from literature survey. Results: LC-MS/MS analysis could detect 9 of the 18 bioactive compounds: citruline, catalpol, berberine, ginsenoside Rb1, ginsenoside Rg1, oleanolic acid, β-sitosterol, mangiferin, and schizandrin. While harmful heavy metals such as As, Pb, Cd, Hg, Ni, and Cu were not present in high concentrations, Zn concentration was 4.2 mg in 100 g Dangnyo-hwan. Conclusions: Instrumental analysis such as LC-MS/MS and ICP was successfully used to identify bioactive compounds in Dangnyo-hwan. Detection of 9 bioactive substances and Zn from the herb medicine is a valuable finding, and suggests that Dangnyo-hwan is a candidate medicine for diabetes. Further investigations like in vitro assay, percent GPR 119 activity, and percent human DGAT-1 inhibition are underway.