Parameterization for Longwave Scattering Properties of Ice Clouds with Various Habits and Size Distribution for Use in Atmospheric Models

  • Jee, Joon-Bum;Lee, Kyu-Tae
    • 대기
    • /
    • 제23권1호
    • /
    • pp.39-45
    • /
    • 2013
  • A parameterization for the scattering of longwave radiation by ice clouds has been developed based on spectral scattering property calculations with shapes and sizes of ice crystals. For this parameterization, the size distribution data by Fu (1996) and by Michell and Arnott (1994) are used. The shapes of ice crystal considered in this study are plate, solid column, hollow column, bullet-rosette, droxtal, aggregate, and spheroid. The properties of longwave scattering by ice crystals are presented as a function of the extinction coefficient, single-scattering albedo, and asymmetry factor. The heating rate and flux by the radiative parameterization model are calculated for wide range of ice crystal sizes, shapes, and optical thickness. The results are compared with the calculated results using a six-stream discrete ordinate scattering algorithm and Chou's method. The new method (with various habits and size distributions) provides a good simulation of the scattering properties and cooling rate in optically thin clouds (optical thickness < 5). Depending on the inclusion of scattering by ice clouds, the errors in the calculation of the cooling rates are significantly different.

동적 계획법을 이용한 냉방시스템 최적운전에 관한 연구 (A Study on Optimal Operation of Cooling System Using Dynamic Programing)

  • 유성연;한규현;이제묘;이일수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1061-1064
    • /
    • 2009
  • The objective of this study is to find the optimal operational planning of the hybrid cooling system, which is combined by ice storage system and the absorption chiller. The optimization technique used in this study is dynamic programming. The objective function is summed cost during a day including charge and discharge periods of ice storage system and operation time of absorption chiller. Assuming that initially ice storage tank is stored fully and the cooling load is perfectly predicted for the operational planning. This method provides the most efficient and economic combination of equipment operational planning for cooling with respect to energy consumption cost.

  • PDF

신경회로망을 이용한 냉방부하예측에 관한 연구 (The Study on Cooling Load Forecast using Neural Networks)

  • 신관우;이윤섭
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.626-633
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. And also the method of forecasting the cooling load using neural network is suggested. For the simulation, the cooling load is calculated using actual temperature and humidity, The forecast of the temperature, humidity and cooling load are simulated. As a result of the simulation, the forecasted data is approached to the actual data.

The Study on Cooling Load Forecast of an Unit Building using Neural Networks

  • Shin, Kwan-Woo;Lee, Youn-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.170-177
    • /
    • 2003
  • The electric power load during the summer peak time is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice storage system and heat pump system etc. are used to settle this problem. In this study, the method of estimating temperature and humidity to forecast the cooling load of ice storage system is suggested. The method of forecasting the cooling load using neural network is also suggested. The daily cooling load is mainly dependent on actual temperature and humidity of the day. The simulation is started with forecasting the temperature and humidity of the following day from the past data. The cooling load is then simulated by using the forecasted temperature and humidity data obtained from the simulation. It was observed that the forecasted data were closely approached to the actual data.

수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착 (Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring)

  • 강채동;손권;백종현;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

온도, 습도 및 냉방부하 예측에 관한 연구 (A Study on the Estimation of Temperature, Humidity and Cooling Load)

  • 유성연;한승호;이제묘;한규현;노관종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.80-85
    • /
    • 2006
  • The peak demand of electricity in summer season mainly comes from the day time cooling loads. Ice thermal Storage System (ITSS) uses off-peak electricity at night time to make ice for the day time cooling. In order to maximize the use of cold storage in ITSS, the estimation of day time cooling load for the building is necessary. In this study, we present a method of cooling load estimation using 5 years of normalized outdoor temperature, relative humidity, and the building construction data. We applied the hourly-based estimation to a general hospital building with relatively less sudden heat exchange and the results are compared with the measured cooling load of the building. The results show that the cooling loads estimation depends on the indoor cooling design temperature of the building.

  • PDF

예측 냉방부하를 이용한 빙축열시스템의 최적 운전계획 (Optimal Scheduling of Ice Storage System with Prediction of Cooling Loads)

  • 이경호;최병윤;주용진;이상렬;한승호
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.982-993
    • /
    • 2000
  • This paper describes an optimal control scheduling of an encapsulated ice storage system with a chiller of nominal chiller 34RT(103,200kcal/hr) and an ice storage tank of 170RT-hrs(514,080 kcal). The optimization technique used in the study is dynamic programing. The objective function is summed cost during a day including charge and discharge periods. Control strategies being used commercially are chiller priority and storage priority control. In chiller priority control, the chiller is allowed to run at full capacity during the day, subject to limitations of the building load, and the ice is only melted when and if the load exceeds the chillers full capacity. In contrast to chiller priority control, the aim in storage priority control is to melt as much as ice as possible during the day time period. The system simulation calculates the operation costs for the three control strategies in the condition of the same cooling load and the same ice storage system. The simulation period is a day, assuming that initially the tank is stored fully and the cooling load is perfectly predicted for the scheduling. Also Final state of the tank is to be charged fully.

  • PDF

예냉처리가 풋옥수수의 냉각속도 및 호흡량 변화에 미치는 영향 (Effect of Precooling on Removal of Field Heat and Respiration Rate of Vegetable Corn(Zes Mays L.))

  • 손영구;김성열
    • 한국식품저장유통학회지
    • /
    • 제3권1호
    • /
    • pp.55-60
    • /
    • 1996
  • To obtain the basic data on precooling effects for establishment the suitable postharvest handling technique or method of keeping high quality of vegetalble corn, the sweet, supersweet and waxy corn, (Danok #2, Cocktail #86 and Chalok #1), being mainly consumed as vegetables in Korea, were precooled with ice or vacuum cooling method immediately after harvest. The vacuum cooling was the most effective for the field heat removal of vegetable corn. It took only 30 min. at 4 to 5 torr of cold chamber pressure of vacuum precooler to lower the corn temperature from 30 to 2$^{\circ}C$. The ice cooling was also thought to be a useful precooling method with relatively short cooling time of 6 hrs. The vegetable corn treated with vacuum or ice cooling showed low and stable respiration rates of 25.5 to 43.5 CO2 mg/kg/hr. when stored at 0∼2$^{\circ}C$ while the samples stored at room temperature (20∼25$^{\circ}C$) without precooling were as high as 64.1 to 245 CO, mg/kg/hr.

  • PDF

냉각복 개발을 위한 효율적 냉각부위 규명에 관한 연구 (Study of Efficient Cooling Part for Cooling Clothes Development)

  • 최정화;황경숙
    • 한국의류학회지
    • /
    • 제26권6호
    • /
    • pp.771-778
    • /
    • 2002
  • Cooling clothes especially cooling vest are being considered for as an efficient way to reduce heat strain under hot environment. But wearing ice gel or ice-based cooling vest caused discomfort to subjects due to the weight of vest. Therefore, this study was executed to find efficient cooling parts and to reduce vest weight by cooling only these parts. Two male subjects were exposed to heat(40$^{\circ}C$, 30%RH) with A type(breast+back+abdomen+waist), B type(breast+back+waist), C type(breast+back+abdomen) and D type(breast+back) cooling vest that distinguished with cooling part. The results were as follows; When subjects were C type and D type vest, sweat volume was less and skin temperature was low. Heart rate and rectal temperature were low in B type and D type. These results suggest that excessive cooling of breast and abdomen may exert a bad influence to health and cooling of back is desirable.

과냉각을 동반한 순수물의 냉각현상 해석 (Analysis of cooling phenomenon of water with the supercooled)

  • 추미선;윤정인;김재돌
    • 대한기계학회논문집B
    • /
    • 제21권7호
    • /
    • pp.862-872
    • /
    • 1997
  • Ice formation in a horizontal circular cylinder has been studied numerically. From the numerical analysis results, it was found that there were three types of freezing pattern and that freezing phenomenon was affected largely by density inversion and cooling rate. The type of freezing pattern largely depends on the secondary flow which is generated by density inversion. When supercooling energy is released before the development of the secondary flow, the annular ice layer grows. If the energy is released when the secondary flow is considerably developed and the supercooled region is removed to the upper half part of the cylinder, an asymmetric ice layer grows. And if the energy is released after perfect development of the secondary flow, instantaneous dendritic ice formation over the full region occurs. Furthermore, this secondary flow was found to have an effect on heat transfer characteristics. The heat transfer rate becomes small at the instant when the secondary flow is generated, but becomes large with the development of the flow. It's concluded that for the facilitation of heat transfer it is desirable to keep water in liquid phase until the secondary flow is perfectly developed. This study gave an instruction of performance improvement of capsule type ice storage tank.