• Title/Summary/Keyword: IW

검색결과 83건 처리시간 0.026초

Removal of Hydrogen Sulfide, Ammonia, and Benzene by Fluidized Bed Reactor and Biofilter

  • Kim, Chong-Woo;Park, Jin-Su;Cho, Sung-Ki;Oh, Kwang-Joong;Kim, Young-Sik;Kim, Dong-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • 제13권2호
    • /
    • pp.301-304
    • /
    • 2003
  • In this study, hydrogen sulfide ($H_2S$), ammonia ($NH_3$), and benzene, which represent the major odor from a natural leather process plant, were removed using a fluidized bed bioreactor and biofilter including Thiobacillus sp. IW and a MY microbial consortium. The critical removal rate was $12g m^{-3}h^{-1}\;for\;H_2S,\;11g m^{-3}h^{-1}\;for\;NH_3\;and\;28 g m^{-3}h^{-1}$ for benzene by the fluidized bed bioreactor, and $8.5g m^{-3}h^{-1}\;for\;H_2S\;7g m^{-3}h^{-1}\;for\;NH_3,\;and\;25 g m^{-3}h^{-1}$ for benzene in the biofilter. The average removal efficiency of $H_2S$, $NH_3$, and benzene by continuous operation for over 30 days with the fluidized bed bioreactor was $95{\pm}3\%,\;99{\pm}1\%,\;and\;98{\pm}5\%$, respectively, whereas that with the biofilter was $96{\pm}4\%,\;95{\pm}4\%,\;and\;97{\pm}3\%$, respectively. Therefore, the critical removal rate of $H_2S$, $NH_3$, and benzene was higher in the fluidized bed bioreactor, whereas the removal efficiency on the continuous operation was similar in both bioreactors.

환경농업조성지구내 용수원 및 채수시기별 수질비교 (Seasonal Variation of Water Quality of the Watersheds in the Agricultural Environment Promotion Zone)

  • 김찬용;김창배;김종수;서영진;윤재탁
    • 한국환경농학회지
    • /
    • 제21권3호
    • /
    • pp.165-171
    • /
    • 2002
  • A study was conducted to investigate the seasonal changes in water quality of watershed in the Agricultural Environment Promotion Zone. Samples collected were 12 GW (ground water), 2 IW (irrigation water), 2 SW (stream water) in An-Dong City, 4 GW, 6 IW, 11 SW in Young-Yang Gun, and sampling was conducted separately during dry and rainy season. In the ground water, EC and ionic species, except pH, were higher than those in stream water, and especially $NO_3-N$ concentration exceeded the limitation of drinking water. Concentration of ions decreased as the sampling depth was far from the soil surface. During a rainy season, the concentrations of $NO_3-N$ and K in the stream water were slightly higher than those during season. COD was lower during dry season in Yong-Yang, while the trend was contrasted to An-Dong. These results suggest that ground water was polluted by fertilization and compost while streamwater was polluted by loss of soil and organic during the rainy season. Principal chemical components related with changing water quality were EC, $NO_3^-$, Ca, Mg, Na, $Cl^-$, $Cl^-$, $SO_4^-$ in ground water, whereas $NH_4-N$, K, Mg, $Cl^-$, $SO_4^-$ in stream water.

황화수소 산화세균인 새로운 Thiobacillus sp.의 분리 및 특성 (Isolation and Characterization of a New Hydrogen Sulfide-Oxidizing Bacterium Thiobacillus Sp.)

  • 차진명;이인화
    • 미생물학회지
    • /
    • 제32권4호
    • /
    • pp.252-257
    • /
    • 1994
  • 황화수소 산화세균인 Thiobacillus sp.를 전남 화순의 폐탄광수에서 분리하였다. 분리된 균주는 그람음성의 운동성이 있고, 포자를 형성하는 간균이었으며, 환원된 무기 황화합물을 산화하여 에너지원으로 사용하는 호기성 통성 화학합성 영양균이었다. 분리균주는 thiosulfate를 첨가한 기본배지에서 유기물을 동화하며 성장하였고, 에너지원으로 사용된 thiosulfate는 32mM 이상의 농도에서는 오히려 기질억제 인자로 작용하여 균의 성장을 억제하였다. 최적 thiosulfate 농도는 32mM이었다. DNA의 G+C 함량은 65.0mol%이고, 세포내 주요 지방산중 비순산화 지방산은 16:1+7$_{cyc}$, 16:0과 수산화 지방산은 3-OH 12:0을 가지며, $C_{18}$의 미동정 가지형의 지방산도 포함하고 있었다. Ubiquinone system은 Q-9을 가지고 있었다. 위와 같은 생리생화학적 특성 결과로부터, 본 분리균주는 Thiobacillus sp. iw.의 새로운 종으로 판단하였다.

  • PDF

물질흐름분석을 통한 사업장폐기물의 실제적인 재활용률과 최종처분율의 산정 및 분석 (Calculation and Analysis of Actual Recycling Rate and Final Disposal Rate of Industrial Waste by Material Flow Analysis)

  • 오길종;조윤아;김지연;김기헌
    • 한국폐기물자원순환학회지
    • /
    • 제35권8호
    • /
    • pp.785-798
    • /
    • 2018
  • Since the Framework Act on Resource Circulation was enacted in 2018, the government should establish a National Resource Circulation Master Plan every 10 years, which defines mid- to long-term policy goals and directions on the efficient use of resources, prevention of waste generation and recycling of waste. In addition, we must set mid- to long-term and stepwise targets for the final disposal rate, recycling rate (based on sorted recyclable materials and recycled products), and energy recovery rate of wastes, and relevant measures should be taken to achieve these targets. However, the current industrial waste (IW) statistics have limitations in setting these targets because the final disposal rate and recycling rate are calculated as the ratio of the recycling facility input to the IW generation. In this study, the material flow from the collection stage to the final disposal of industrial waste was analyzed based on the generation of 2016, and the actual recycling amount, actual incineration amount, final disposal amount and their rates were calculated. The effect on the recycling, incineration and final disposal rates was examined by changing the treatment method of nonhazardous wastes from the factory and construction and demolition wastes, which were put in landfills in 2016. In addition, the variation of the waste treatment charge was investigated according to the change of treatment methods. The results of this study are expected to be effectively used to establish the National Resource Circulation Master Plan and industrial waste management policy in the future in South Korea.

쾌적한 상태에서 계절별 의복을 착용하고 있는 동안 불감증설과 온열 생리 요소들 간의 관련성 (Relationships between Insensible Perspiration and Thermo Physiological Factors during Wearing Seasonal Clothing Ensembles in Comfort)

  • 이주영;최정화;박준희
    • 한국의류학회지
    • /
    • 제31권12호
    • /
    • pp.1700-1709
    • /
    • 2007
  • 본 연구의 목적은 계절별 의복을 착용하고 쾌적한 상태를 유지하는 동안 불감체중손실과 온열 생리적 요소들간의 관련성을 살펴보는 것이다. 이를 위해 한국의 계절별 실내 환경이 인공기후실에 조성되었고 (봄/가을 환경 기온 평균 22.5, 여름 24.7, 겨울 16.8), 설문조사를 바탕으로 총 26 종의 계절별 한벌의복이 선정되었다(봄/가을 옷 8종, 여름 옷 7종, 겨울 옷 11종). 다섯 명의 젊은 여성이 피험자로 참여하였으며, 결과는 다음과 같다: 1) 불감체중손실(IL)은 봄/가을 의복을 착용한 경우 $19{\pm}5g{\cdot}m^{-2}{\cdot}hr$, 여름 옷 $21{\pm}5g{\cdot}m^{-2}{\cdot}hr$, 겨울 옷 $18{\pm}6g{\cdot}m^{-2}{\cdot}hr$으로, 겨울 환경보다 여름 환경에서 더 컸다(p<.001). 2) 호흡기를 통한 불감수분손실(IWR)은 불감체중손실과 반대의 경향을 보여 주어, 겨울옷을 입은 경우 $6{\pm}1g{\cdot}m^{-2}{\cdot}hr$, 여름 옷을 입은 경우 $5{\pm}1g{\cdot}m^{-2}{\cdot}hr$ 였다(p<.001). 3) 불감수분손실 (IW)에서 호흡기를 통한 불감수분손실이 차지하는 비중은 여름 옷을 착용한 경우 평균 28%, 겨울 의복의 경우 38%였다(p<.001). 4) 쾌적한 상태에서, 산열량 중 불감수분손실이 차지하는 비율은 봄/가을 의복을 착용한 경우 25%, 여름옷의 경우 27%, 겨울옷의 경우 23%였다. 5) 불감체중손실과 의복의 보온력 간, 그리고 불감체중손실과 피복면적 간에는 모두 약한 역상관 관계가 관찰되었다. 6) 불감체중손실은 기온, 기습, 에너지 대사, 환기량, 평균피부온도, 의복내 습도 등의 요소와 유의한 상관을 보였으나, 상관계수들은 모두 0.5 이하였다. 결론적으로, 불감체중손실과 온열 생리 요인들 간에는 약한 상관이 존재했으나, 피험자들이 온열 쾌적을 유지하는 경우 착용한 의복 종류 및 노출 기온에 상관없이 불감체중손실량은 좁은 범위를 유지했다.

Polyurethane을 이용한 Thiobacillus sp. IW의 고정화

  • 황은상;임근길;이광우;강춘형;류화원;박돈희
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.536-539
    • /
    • 2000
  • A simple and effective method has been developed for the immobilization of the cell on polyurethane foam. Two types of commercially available polyurethane foam and Hydro-filt were tested. The ultimate purpose of the process is to produce low-cost materials for hydrogen sulfide removal which are being increasingly used for industrial application. Effect of several parameters were studied on the cell loading. These parameters were type, size, and amount of polyurethane foam. MC-70 was the best immobilization material of three type of carriers, and optical particle size was $5{\sim}8mm$ and amount of polyurethane foam was 8g/L.

  • PDF

탄소섬유시트(CFS)로 보강된 철근콘크리트 보의 전단내력에 관한 연구 (A Study on the Shear Capacity of Reinforced Concrete Beams Strengthened with Carbon Fiber Sheets)

  • 권철성;김하용;권우현;백승민;곽윤근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.259-262
    • /
    • 2005
  • This paper deals with the shear strengthening effect of RC beams strengthened with carbon fiber sheets. Fifteen strengthened RC beams(including control beam) were experimentally evaluated to determine improvements in shear strength. The major parmeters of experiment variables are fiber sheet strengthening ratios and strengthening methods of fiber sheet(I-S, I-W, U-S, U-W type). Reinforced concrete beams strengthened with carbon fiber sheets were tested under the combined control of load. Considering strengthening ratios and strengthening methods of fiber sheet, shear capacity and failure mode of test specimens were evaluated. The results show that shear capacity of beams strengthened with fiber sheet is about $28.82\%$ in IS type, $20.49\%$ in IW type, $26.04\%$ in US type, $28.70\%$ in UW type higher than the strength of control beam.

  • PDF

Removal of Hydrogen Sulfide and Methylmercaptan Using Thiobacillus in a Three Phase Fluidized Bed Bioreactor

  • KIM, KYUNG-RAN;KWANG-JOONG OH;KYUNG-YONG PARK;DONGUK KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제9권3호
    • /
    • pp.265-270
    • /
    • 1999
  • A three phase fluidized bed bioreactor immobilized with Thiobacillus sp. IW was tested to remove hydrogen sulfide and methylmercaptan with high loading rate. In a single gas treatment, the bioreactor removed 92- 98% of hydrogen sulfide with loading rate of 15- 66 g/l/h and removed 87-98% of methylmercaptan with loading rate of 14-60 gl/sup -1/h/sup -1/. In the mixed gas treatment, the removal efficiencies of hydrogen sulfide and methylmercaptan maintained at 89-99% for various inlet loading rates and were not affected by the inlet loading ratio of both gases in low loading rates. When the inlet concentration of methylmercaptan increased 3.8 times and was maintained for 30 h to observe the response of the bioreactor to sudden environmental change, the removal efficiency of methylmercaptan was maintained at an average of 91%.

  • PDF