• Title/Summary/Keyword: IW

Search Result 83, Processing Time 0.029 seconds

Biofilter를 이용한 천연피혁제조공장의 악취성분제거

  • Kim, Jong-U;Mun, Jong-Hye;Park, Jin-Su;O, Gwang-Jung;Kim, Dong-Uk
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.163-166
    • /
    • 2000
  • Hydrogen sulfide, ammonia and benzene which are generated from natural leather industry were simultaneously removed using biofilter including benzene degrading microbial consortia and sulfur oxidizer Thiobacillus sp.IW. The removal efficiency of benzene was maintained 90% in average for single and mixed gas treatment and that of ammonia was 99%, whereas at of hydrogen sulfide was relatively lower 85%.

  • PDF

Development and culture optimization of mutants of Thiobacillus sp. IW for elimination of hydrogen sulfide

  • Kang, Sun-Chul;Lim, Kwang-Hee;Shin, Seung-Yong
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.465-467
    • /
    • 2005
  • UIW-10 mutant obtained by UV treatment using sulfur-oxidizing bacteria, Thiobacillus sp. IW was studied. The colony size of UIW-10 was found 2 $^{\sim}$ 3 times bigger in diameter than the parent colony on TAM medium. UIW-10 mutant growth was two times higher than parent strain at 6 h culture in liquid medium containing sulfides such as sulfur and sodium thiosulfate. Initial pH and temperature for the optimum growth of UIW-10 were 6.0 and $35-40^{\circ}C$, respectively. It was found that addition of 0.5% yeast extract and 0.5 to 2.0% tryptone as nitrogen sources and the constant agitation at 150 to 200 rpm had a positive effect and the growth of UIW-10 was increased.

  • PDF

A Research Framework for the Success Factors of Information

  • Yoo, Sangjin;Soongoo, I-Iong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.3 no.1
    • /
    • pp.117-139
    • /
    • 1998
  • This study is intended to identify the factors affecting the successful information warehouse (IW) implementation through the technology acceptance model. As the IW has played an important role with the organizations, it has become a strategic management tool. However, because the building of an IWS requires a great amound of financing and a multi-period, managers should consider identifying the variables as a predictor of IWS success. The related research areas, such as TAM , TRA, and innovation diffusion theory, and previous research associated with the EWS success factors are reviewed in this paper. Based on the hypotheses presented , the study will empirically test the relationships between six external variable-user involvement, computer self-efficacy, OLAP characteristics, problem difficulty , user training and top management support-and system utilization via user's perceptions of ease of use, unusefulness. This study semmes to be a first attempt in this research area, and its results will provide general guidclines for IWS project managers to enhancement the like hood of system succes.

The hydrodynamic dispersion characteristics of chloride in high permeable alluvial deposit at the Ttaan island, Kimhae city (김해시 딴섬의 고투수성 충적층에서 염소이온의 수리분산특성)

  • Kang, Dong-Hwan;Kim, Tae-Yeong;Yang, Sung-Il;Chung, Sang-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.707-711
    • /
    • 2007
  • 낙동강과 밀양강의 합류지점에 위치한 김해시 딴섬 지역의 지표면하 $25{\sim}35\;m$ 구간에 형성되어 있는 고투수성 충적층 내 염소이온의 수리분산특성을 연구하기 위한 수렴흐름 추적자시험(convergent flow tracer test)이 수행되었다. 추적자로는 IW-1공과 IW-2공에서 각각 염소이온 5kg이 순간주입(instantaneous injection) 되었으며, PW공에서 일정한 양수율(2,500 m3 /day)로 채수하면서 염소이온농도를 관측하였다. 염소이온 주입 후 경과시간에 따른 염소이온농도 자료를 이용하여 농도이력곡선과 누적질량회수곡선이 산출되었으며, 관측된 염소이온농도의 정규분포를 검증하기 위한 일반통계분석이 수행되었다. 그리고, 농도이력의 증가/감소 구간에서의 함수를 추정하였으며, 두 시험에서 동일한 시간에 관측된 염소이온농도의 상관성이 분석되었다. 본 현장에서 수행된 추적자시험에 의한 종분산지수의 추정은 CATTI 코드(Sauty and Kinzelbach, 1992)에 의해 해석되었다. 추정된 종분산지수는 IW-1공과 PW공 구간에서는 0.4152 m, IW-2공과 PW공 구간에서는 0.4158 m 로서 매우 유사한 값으로 나타났다. 이는 추적자시험이 수행된 충적층에서의 용질이송이 방사상으로 비교적 균일함을 의미하는 것이다. 본 연구에서 수행된 추적자시험의 규모(2 m)를 Xu and Eckstein(1995)이 제시한 방정식에 대입하여 산정된 종분산지수는 0.0458 m 이었다. 이러한 결과는, 본 연구지역에서 수렴흐름 추적자시험에 의해 추정된 고투수성 충적층의 종분산지수가 일반적인 자연대수층에 비해 9.1배 정도 높다는 것을 의미한다. 이는 시험대수층의 투수성이 매우 높아 염소이온의 용질이송이 매우 빠르게 발생되었기 때문이다. 본 연구에서 추정된 종분산지수를 Gelhar et al.(1992)의 연구 결과와 비교 분석한 결과에서도 시험규모에 비해 매우 높은 수리분산이 발생된 것으로 나타났다. 그리고 염소이온의 확산면적을 추정하기 위해, 수렴흐름 추적자시험에 의한 종분산지수와 시험대수층의 평균선형유속을 이용하여 종분산계수를 구하였다. 현장에서 수행된 양수시험에 의한 평균선형유속 22.44 m/day와 평균 종분산지수 0.4155 m를 적용하여 산정된 종분산계수는 $9.32\;m^2/day$이었다. 따라서, 시험부지 내 충적층에서 일정한 양수율$(2,500\;m^3/day)$로 지하수를 개발할 시에 양수정 주변지역으로 유입되는 염소이온의 확산면적은 1일 $9.32\;m^2$ 정도일 것으로 나타났다.

  • PDF

Semi-pilot Scaled Biofilter Treatment of Malodorous Waste Air Containing Hydrogen Sulfide and Ammonia: 1. Performance of Biofilter Packed with Media with Immobilized Thiobacillus sp. IW and Return-sludge (황화수소와 암모니아를 함유한 악취폐가스의 세미파일럿 규모 바이오필터 처리: 1. Thiobacillus sp. IW 및 반송슬러지를 고정한 담체를 충전한 바이오필터 운전)

  • Lee, Eun Ju;Park, Hyeri;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.568-574
    • /
    • 2013
  • A semi-pilot biofilter packed with media with immobilized Thiobacillus sp. IW and return sludge, was operated under various operating conditions in order to treat malodorous waste air containing both hydrogen sulfide and ammonia which are major air pollutants emitted from composting factories and many publicly owned treatment works (POTW). At the incipient and middle stages of a semi-pilot biofilter operation, the hydrogen sulfide-removal efficiency behaves regardless of an inlet-load of ammonia. However, the ammonia-removal efficiency decreased as an inlet-load of hydrogen sulfide increased. Nevertheless, at the final stage of the semi-pilot biofilter operation, the ammonia-removal efficiency was not affected by the increase of hydrogen sulfide-inlet load. It is attributed to that a serious acidification of semi-pilot biofilter-media did not occur due to continuous injection of buffer solution at the final stage of the semi-pilot biofilter operation. When both hydrogen sulfide and ammonia contained in malodorous waste air were treated simultaneously by semi-pilot biofilter, the maximum elimination capacities of hydrogen sulfide and ammonia turned out to be ca. 58 and $30g/m^3/h$, respectively. These maximum elimination capacities were estimated to be ca. 39 and 46% less than those for lab-scaled biofilter-separate elimination of hydrogen sulfide and ammonia, respectively. Thus, for the simultaneous biofilter-treatment of hydrogen sulfide and ammonia, the maximum elimination capacity of ammonia decreased by 7% more than that of hydrogen sulfide.

Intraindividual Comparison of Hepatocellular Carcinoma Washout between MRIs with Hepatobiliary and Extracellular Contrast Agents

  • Yeun-Yoon Kim;Young Kon Kim;Ji Hye Min;Dong Ik Cha;Jong Man Kim;Gyu-Seong Choi;Soohyun Ahn
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.725-734
    • /
    • 2021
  • Objective: To intraindividually compare hepatocellular carcinoma (HCC) washout between MRIs using hepatobiliary agent (HBA) and extracellular agent (ECA). Materials and Methods: This study included 114 prospectively enrolled patients with chronic liver disease (mean age, 55 ± 9 years; 94 men) who underwent both HBA-MRI and ECA-MRI before surgical resection for HCC between November 2016 and May 2019. For 114 HCCs, the lesion-to-liver visual signal intensity ratio (SIR) using a 5-point scale (-2 to +2) was evaluated in each phase. Washout was defined as negative visual SIR with temporal reduction of visual SIR from the arterial phase. Illusional washout (IW) was defined as a visual SIR of 0 with an enhancing capsule. The frequency of washout and MRI sensitivity for HCC using LR-5 or its modifications were compared between HBA-MRI and ECA-MRI. Subgroup analysis was performed according to lesion size (< 20 mm or ≥ 20 mm). Results: The frequency of portal venous phase (PP) washout with HBA-MRI was comparable to that of delayed phase (DP) washout with ECA-MRI (77.2% [88/114] vs. 68.4% [78/114]; p = 0.134). The frequencies were also comparable when IW was allowed (79.8% [91/114] for HBA-MRI vs. 81.6% [93/114] for ECA-MRI; p = 0.845). The sensitivities for HCC of LR-5 (using PP or DP washout) were comparable between HBA-MRI and ECA-MRI (78.1% [89/114] vs. 73.7% [84/114]; p = 0.458). In HCCs < 20 mm, the sensitivity of LR-5 was higher on HBA-MRI than on ECA-MRI (70.8% [34/48] vs. 50.0% [24/48]; p = 0.034). The sensitivity was similar to each other if IW was added to LR-5 (72.9% [35/48] for HBA-MRI vs. 70.8% [34/48] for ECA-MRI; p > 0.999). Conclusion: Extracellular phase washout for HCC diagnosis was comparable between MRIs with both contrast agents, except for tumors < 20 mm. Adding IW could improve the sensitivity for HCC on ECA-MRI in tumors < 20 mm.

LINEAR INTERNAL WAVES THAT FOLLOWS NONLINEAR INTERNAL WAVES

  • Liu, Cho-Teng;Chyou, Yuan-Jie;Chao, Yen-Hsiang;Lee, Chang-Wei
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.364-367
    • /
    • 2006
  • Nonlinear internal waves (NLIWs) are usually generated by nonlinear process on linear internal waves (IW). Near HengChun Ridge that links Taiwan and Luzon Islands, we found that there are linear internal waves following NLIW and they travel westward at different speed, about 1.5 m/s for IW and 2.9 m/s for NLIW. This phenomenon was observed on site with ship radar and echo sounders, and later verified with thermistor chain. West of Luzon Strait, the separation of NLIW are 5 km or more, while linear internal waves are lines of wave crests at nearly equal distance that is only a few hundred meters apart. The current hypothesis is that most of the energy of internal tide forms a beam that propagates upward from the eastern shoulder of ocean ridge and later interacts with sea surface and thermocline. The interaction with thermocline generates linear internal wave that propagate along the pycnocline at about 1.5 m/s. The interaction with sea surface scatters internal wave energy downward, ensonifies the water column and generates large nonlinear waves that propagate westward at 2.9 m/s as mode 1 in a waveguide.

  • PDF

The Case Report of 1 case of Patient with Dysfunction of Autonomic Nervous System by oriental medical therapy (가미온담탕(加味溫膽湯)으로 호전된 자율신경실조증 환자 1례)

  • Lim, Jae-Won;Yim, Hyeon-Ju;Jung, In-Chul;Lee, Sang-Ryong
    • Journal of Haehwa Medicine
    • /
    • v.18 no.1
    • /
    • pp.101-107
    • /
    • 2009
  • Objectives: The purpose of this study is to show a case of patient with dysfunction of autonomic nervous system improved by oriental medical treatment. Methods: This patient was 66 year-old woman who complained pantalgia including abdominal pain and headache, cold sweating, anxiety, palpitation and fatigue. She was treated by herbal medicine(加味溫膽湯 $ji\bar{a}w\grave{e}iw\bar{e}nd\breve{a}nt\bar{a}ng$), acupuncture, moxa and aroma therapy. We used VAS(Visual analogue scale) to measure the progress of symptoms. Results : The symptoms of dysfunction of autonomic nervous system was improved after oriental medical therapy. Conclusions : This study suggests that oriental medicine therapy is effective in the trearment of dysfunction of autonomic nervous system.

  • PDF

Removal of Hydrogen Sulfide by Biofilter Media (담체 종류에 따른 황화수소의 제거특성)

  • Cha, Gyusuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.4
    • /
    • pp.41-45
    • /
    • 2007
  • It is very important that selection of packing media with large surface area, high limited back pressure in biofilter. The object of this study is the isolation of sulfur-oxidizing bacteria and the removal of hydrogen sulfide in biofilter by media. This investigation led to the following results: 1) we isolated Thiobacillus sp. IW. at an abandoned coal mine in Hwasun, Jeonnam Province. 2) The inorganic media showed better results than the organic media from experiments looking at removal characteristics and changes in pressure drop using various media. 3) Among the inorganic media, fibril and PU media showed best performance.

  • PDF

Semi-pilot Scaled Biofilter Treatment of Malodorous Waste Air Containing Hydrogen Sulfide and Ammonia: 2. Performance of Biofilter Packed with Media Inoculated with a Consortium of Separated Microbes (황화수소와 암모니아를 함유한 악취폐가스의 세미파일럿 규모 바이오필터 처리: 2. 분리 미생물들을 접종한 담체를 충전한 바이오필터 운전)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.240-246
    • /
    • 2014
  • A semi-pilot biofilter inoculated with the microbes consortium of Bacillus cereus DAH-1056 and Arthrobacter sp. KDE-0311 was operated under various operating conditions in order to treat malodorous waste air containing both hydrogen sulfide and ammonia. When both hydrogen sulfide and ammonia contained in malodorous waste air were treated simultaneously by semi-pilot biofilter inoculated with Thiobacillus sp. IW and return-sludge, the removal efficiencies of hydrogen sulfide and ammonia were ca. 80% and ca. 50%, respectively. On the other hand, in this study, the removal efficiencies of hydrogen sulfide and ammonia were ca. 90% and ca. 60%, respectively. Therefore, the removal efficiencies of hydrogen sulfide and ammonia were enhanced by ca. 13% and 20%, respectively, compared to the semipilot biofilter inoculated with Thiobacillus sp. IW and return-sludge. In addition, in this study, the maximum elimination capacities of hydrogen sulfide and ammonia were enhanced by ca. 15% ($8g/m^3/h$) and 10~17% ($3{\sim}5g/m^3/h$), respectively. In this study, it was observed either that in case of even a same inlet load of hydrogen sulfide, a higher concentration of hydrogen sulfide causes more difficulties in treating ammonia containing in waste air than a lower one, or that in case of even a same inlet load of ammonia, a lower concentration of ammonia results in higher removal efficienciy and elimination capacity than a higher one. Even though hydrogen sulfide and ammonia were treated simultaneously by a biofilter in this study, the maximum elimination capacity of hydrogen sulfide in this study exceeded or was similar to that in previous study of biofilter treating only hydrogen sulfide. In addition, this study showed the higher maximum elimination capacity of ammonia than other previous investigation of biofilter treating hydrogen sulfide and ammonia simultaneously.