• 제목/요약/키워드: IVR

검색결과 65건 처리시간 0.024초

VoiceXML을 이용한 IVR 서버 설계 및 구현 (Design and Implementation of IVR Server Using VoiceXML)

  • 이창호;장원조;강선미
    • 음성과학
    • /
    • 제9권3호
    • /
    • pp.47-59
    • /
    • 2002
  • A new brilliant service using human-voice and DTMF (Dual Tone Multi Frequency) technique is expected nowadays in order to obtain valuable information on the internet more easily. VoiceXML (Voice eXtensible Markup Language) is the right choice that makes the new service possible. In this paper, the design and implementation of IVR (Interactive Voice Response) server using VoiceXML is described, where it connects with internet and IVR server efficiently. IVR server using VoiceXML is composed of two groups: VoiceXML document handling and VoiceXML execution. Scenario part of IVR server corresponds to VoiceXML document, the execution is performed by VoiceXML execution.

  • PDF

Impact of the Fidelity of Interactive Devices on the Sense of Presence During IVR-based Construction Safety Training

  • Luo, Yanfang;Seo, JoonOh;Abbas, Ali;Ahn, Seungjun
    • 국제학술발표논문집
    • /
    • The 8th International Conference on Construction Engineering and Project Management
    • /
    • pp.137-145
    • /
    • 2020
  • Providing safety training to construction workers is essential to reduce safety accidents at the construction site. With the prosperity of visualization technologies, Immersive Virtual Reality (IVR) has been adopted for construction safety training by providing interactive learning experiences in a virtual environment. Previous research efforts on IVR-based training have found that the level of fidelity of interaction between real and virtual worlds is one of the important factors contributing to the sense of presence that would affect training performance. Various interactive devices that link activities between real and virtual worlds have been applied in IVR-based training, ranging from existing computer input devices (e.g., keyboard, mouse, joystick, etc.) to specially designed devices such as high-end VR simulators. However, the need for high-fidelity interactive devices may hinder the applicability of IVR-based training as they would be more expensive than IVR headsets. In this regard, this study aims to understand the impact of the level of fidelity of interactive devices in the sense of presence in a virtual environment and the training performance during IVR-based forklift safety training. We conducted a comparative study by recruiting sixty participants, splitting them into two groups, and then providing different interactive devices such as a keyboard for a low fidelity group and a steering wheel and pedals for a high-fidelity group. The results showed that there was no significant difference between the two groups in terms of the sense of presence and task performance. These results indicate that the use of low-fidelity interactive devices would be acceptable for IVR-based safety training as safety training focuses on delivering safety knowledge, and thus would be different from skill transferring training that may need more realistic interaction between real and virtual worlds.

  • PDF

A narrative review on immersive virtual reality in enhancing high school students' mathematics competence: From TPACK perspective

  • Idowu David Awoyemi;Feliza Marie S. Mercado;Jewoong Moon
    • 한국수학교육학회지시리즈A:수학교육
    • /
    • 제63권2호
    • /
    • pp.295-318
    • /
    • 2024
  • This narrative review explores the transformative potential of immersive virtual reality (IVR) in enhancing high school students' mathematics competence, viewed through the lens of the technological, pedagogical, and content knowledge (TPACK) framework. This review comprehensively illustrates how IVR technologies have not only fostered a deeper understanding and engagement with mathematical concepts but have also enhanced the practical application of these skills. Through the careful examination of seminal papers, this study carefully explores the integration of IVR in high school mathematics education. It highlights significant contributions of IVR in improving students' computational proficiency, problem-solving skills, and spatial visualization abilities. These enhancements are crucial for developing a robust mathematical understanding and aptitude, positioning students for success in an increasingly technology-driven educational landscape. This review emphasizes the pivotal role of teachers in facilitating IVR-based learning experiences. It points to the necessity for comprehensive teacher training and professional development to fully harness the educational potential of IVR technologies. Equipping educators with the right tools and knowledge is essential for maximizing the effectiveness of this innovative teaching approach. The findings also indicate that while IVR holds promising prospects for enriching mathematics education, more research is needed to elaborate on instructional integration approaches that effectively overcome existing barriers. This includes technological limitations, access issues, and the need for curriculum adjustments to accommodate new teaching methods. In conclusion, this review calls for continued exploration into the effective use of IVR in educational settings, aiming to inform future practices and contribute to the evolving landscape of educational technology. The potential of IVR to transform educational experiences offers a compelling avenue for research and application in the field of mathematics education.

The Experience in Dose Measurement of IVR with Glass Dosimeter System

  • Nishizawa, Kanae;Moritake, Takashi;Iwai, Kazuo;Matsumaru, Yuji;Tsuboi, Koji;Maruyama, Takashi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.269-271
    • /
    • 2002
  • It is reported that exposure for the patient and the medical staff from IVR is large. Direct measurement of patient exposure is difficult, since the measurement disturbs reading of images. The fluorescence glass-dosimeter system consisting of small-size glass chips is developed in recent years. Owing to its small size and physical characteristics, direct monitoring of surface dose may be feasible. The dose measurement for patient and medical staff during head interventional radiology (IVR) examinations was tried by using the fluorescence glass-dosimeter system. A dose response of the glass dosimeter is almost linear in large dose range but its energy dependency is high. About 20% variation of sensitivity was observed in the effective energy of 45-60keV which was used in IVR. In spite of this shortcoming, the fluorescence glass-dosimeter system is a convenient means for a dose monitoring during IVR performance.

  • PDF

A Systems Engineering Approach to Ex-Vessel Cooling Strategy for APR1400 under Extended Station Blackout Conditions

  • Saja Rababah;Aya Diab
    • 시스템엔지니어링학술지
    • /
    • 제19권2호
    • /
    • pp.32-45
    • /
    • 2023
  • Implementing Severe Accident Management (SAM) strategies is crucial for enhancing a nuclear power plant's resilience and safety against severe accidents conditions represented in the analysis of Station Blackout (SBO) event. Among these critical approaches, the In-Vessel Retention (IVR) through External Reactor Vessel Cooling (IVR-ERVC) strategy plays a key role in preventing vessel failure. This work is designed to evaluate the efficacy of the IVR strategy for a high-power density reactor APR1400. The APR1400's plant is represented and simulated under steady-state and transient conditions for a station blackout (SBO) accident scenario using the computer code, ASYST. The APR1400's thermal-hydraulic response is analyzed to assess its performance as it progresses toward a severe accident scenario during an extended SBO. The effectiveness of emergency operating procedures (EOPs) and severe accident management guidelines (SAMGs) are systematically examined to assess their ability to mitigate the accident. A group of associated key phenomena selected based on Phenomenon Identification and Ranking Tables (PIRT) and uncertain parameters are identified accordingly and then propagated within DAKOTA Uncertainty Quantification (UQ) framework until a statistically representative sample is obtained and hence determine the uncertainty bands of key system parameters. The Systems Engineering methodology is applied to direct the progression of work, ensuring systematic and efficient execution.

IVR장치의 성능 평가 기준 개발 (Establishment of Quality Control System for Angiographic Unit)

  • 강병삼;손진현;김승철
    • 한국콘텐츠학회논문지
    • /
    • 제11권1호
    • /
    • pp.236-244
    • /
    • 2011
  • 성능이 저하된 IVR 장치의 지속적 사용은 환자 및 시술자의 방사선 피폭을 증가시킬 뿐 아니라, 잘못된 영상정보를 제공함으로써 환자에게 심각한 영향을 끼칠 수 있다. 따라서 이번 연구에서는 IVR장치의 성능평가를 위한 적절한 시험방법 및 검사기준을 마련하고자 하였다. IVR장치의 국내현황 및 규격을 조사하였으며, 표준팬텀을 이용하여 국내 IVR장치의 성능을 현장 측정함으로써, 국내 실정에 맞는 적절한 IVR 장치의 화질 및 성능평가 기준을 설정하였다. 장치의 기본적 성능에 관한 검사를 위해 관전압시험, 관전류 시험, 반가층 시험을 실시하며, NEMA stndard XR-21 Phantom을 표준팬텀으로 사용하여 화질 및 선량 평가를 하도록 하였다. 표준팬텀을 이용한 검사항목은 image-field geometry, spatial resolution, low-contrast iodine detectability, wire resolution, phantom entrance dose이다. 또한 매일, 매주, 1개월, 3개월, 6개월 및 1년 주기의 평가항목을 설정하였다. 장치의 성능기준은 진단용방사선안전관리 규정을 준용하여 kVp시험은 평균오차 ${\pm}10%$, mA시험은 평균오차 ${\pm}15%$, 반가층시험은 80kVp에서 최소 2.3mmAl으로 설정하였다. 표준팬텀의 검사기준은 image-field geometry에서 최소 acceptable이 나와야 하며, spatial resolution은 Image Intensifier 나 detector 크기기준으로 34-40cm은 0.8 lp/mm, 28-33cm은 1.0lp/mm, 22-27cm은 1.2 lp/mm이상이 나와야 한다. low contrast iodine detectability는 최소농도 200mg/cc 이상 보여야 하며, phantom entrance dose는 10R/min을 초과해서는 안 된다. Wire resolution은 정지 상태에서 최소 0.012인치까지 보여야 하며, 움직일 때 최소 0.022인치까지 보여야 한다.

다중 채널 서비스를 위한 결함허용 IVR 설계 및 구현 (Design and Implementation of Fault-Tolerant IVR for Multi-Channel Service)

  • 한윤기;구용완
    • 인터넷정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.103-117
    • /
    • 2008
  • 일반 고객이 대기업 혹은 중소기업, 증권, 금융, 은행권 등의 서비스를 제공받기 위해서는 보편적으로 인터넷, SMS(Short Message Service), ATM(Automated Teller Machine), DM(Direct Mail), 텔레포니 서비스 등을 사용한다. 특히, 화재 보험사 및 증권, 금융, 은행권의 경우는 QoS(Quality of Service) 보장을 통한 실시간성 제약 조건을 만족해야 한다. 본 논문에서는 고객의 최초 접점으로 이용될 수 있는 CRM(Customer Relationship Management) 환경 하에서 다중 채널 서비스를 위한 결함허용 IVR(Interactive Voice Response)을 설계 구현하였다. 제안한 모델은 대 고객 응대 CRM 모델로 효율적으로 이용될 것으로 사료된다.

  • PDF

인터벤션 방사선발생장치에서 입사표면선량률 평가 (Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment)

  • 강병삼;장광현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.

경계-보존 방향성 평활화를 이용한 양안 영상의 변이 추정과 중간 시점 영상의 재구성 (Edge-Preserving Directional Regularization Technique for Disparity Estimation and Intermediate View Reconstruction of Stereoscopic Images)

  • 김미현;강문기;이철희;최윤식;손광훈
    • 방송공학회논문지
    • /
    • 제4권1호
    • /
    • pp.59-67
    • /
    • 1999
  • 본 논문에서는 입체 영상 시스템 중 전송단에서의 영상의 입체감 분석을 위한 변이추정 과정과 수신단에서의 중간시점영상 재구성 방식에 대해 중점적으로 연구하였다. 변이추정은 기본적으로 MAE(mean absolute error)를 최소가 되도록 하는 동시에, 블록의 변이를 각 방향에서의 영상의 벼화량에 반비례하게 평활화하는 반복적 블록 정합 방식을 제안하여 적용하였다. 수신단에서는 복원된 영상과 변이 정보를 이용하여 중간시점 영상을 재구성하였으며, 보간법(interpolation)을 사용하는 동시에 좌 또는 우영상의 가려진 영역(occlusion)에서는 좌우 영상 중 한 영상에서의 외삽법(extrapolation)을 사용하여 변이-보상 변이 전달방식으로 이를 합성하였다. 이 변이 추정 방식으로영상의 평활 영역에서 일정하게 평활화된 변이를 추정하여 변이 정보에 대한 정보량을 줄이고, 경계부분에서는 평활화 방식에서 흔히 발생하는 과평활화 문제를 해결하였다. 또한 IVR 에서는 다른 방식에 비해 영상의 경계 부분을 보존하며, occlusion 영역을 잘 살리는 특성을 보였다.

  • PDF