• 제목/요약/키워드: IV method

검색결과 1,251건 처리시간 0.031초

Partially Balanced Resolution IV' Designs in a 2^m-Factorial

  • Paik, U.B.
    • Journal of the Korean Statistical Society
    • /
    • 제11권1호
    • /
    • pp.1-11
    • /
    • 1982
  • Srivastava and Anderson(1970) illustrate a method of obtaining Balanced (but not orthogonal) Resolution $IV^*$ designs starting with a BIB design. The incidence matrix of a BIB design with parameters (v, b, r, k, and $\lambda$) is utilized to obtain Balanced Resolution $IV^*$ designs with m factors and n=2b runs, where $m \leq v$. In this paper, the same idea is extended to the case of PBIB designs to obtain Partially Balanced Resolution $IV^*$ designs. In the designs obtained here the variances are balanced and the covariances are partially balanced with respect to the main effects. A proof of this property of Partially Balanced Resoultion $IV^*$ designs is given. The efficiency of Partially Balanced Resolution $IV^*$ designs is also considered and examples of Partially Balanced Resoultion $IV^*$ designs are included.

  • PDF

마네킹 모델과 컴퓨터 시뮬레이터를 이용한 정맥주사 실습교육의 효과 비교 (Comparison of Training Effectiveness for IV Injections: Intravenous (IV) Arm Model versus Computer Simulator)

  • 황주희;김현정
    • 기본간호학회지
    • /
    • 제21권3호
    • /
    • pp.302-310
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the effectiveness of training using an intravenous (IV) arm model versus a computer simulator for IV injections. Method: Study was a quasi-experimental study conducted with 106 nursing students. Participants were divided into two groups: the IV Arm Group using a mannequin arm model (control group) and the Computer Simulator Group using the Virtual IV demonstration (experimental group). Theoretical lectures and video presentations on IV injections were given to both groups. Each group went through the training practice using the IV arm or computer simulator. After the completion of training, questionnaires were given to the students to evaluate their learning attitudes and experiences, self-confidence in IV injection, and satisfaction with the training materials. Results: Student satisfaction with the training materials including the reality, usefulness, and educational effects showed notable differences between the two groups with the Computer Simulator group reporting more positive effects that the IV Arm group. However, there was no statistical difference between the two groups in the categories of learning attitude, learning experience, or self-confidence. Conclusion: While there was a differences in strengths and weaknesses of the two methods, both methods should be considered for practice and further study needs to be done on educational effectiveness.

2-Oximino-1-indanone을 이용한 Pt(IV) ion의 정량에 관한 연구 (Spectrophotometric Determination of Platinum (IV) with 2-Oximino-1-indanone)

  • 김정균;유미경;원미숙;심윤보;고영심
    • 약학회지
    • /
    • 제28권2호
    • /
    • pp.61-67
    • /
    • 1984
  • A method is described for the spectrophotometric determination of platinum (IV) with 2-oximino-1-indanone based on solvent extraction of Pt:2-oximino-1-indanone complex. The 2-oximino-1-indanone reacted with Pt(IV) to form a dark-orange complex which shows a characterisic maximum absorption at 342nm. The optimum PH for the platinum extraction lies between 5.4~8.0. Beer's law obeys up to 0.98-16.3ppm of platinum (IV) and the molar absorption coefficient is $1.06{\times}10^{-4}L.mol^{-1}.cm^{-1}$. The relative standard deviation of the method was $\times2.1%$. The composition of the complex is estimated to be Pt : In= 1 : 1, by the mole ratio method and ion exchange resin experiment. The optimum condition for the determination of platinum has been studied in detail. The 2-oximin-1-indanone is found to be a selectivereagent for the determination of platinum, since the synthesixed 2-oximino-1-indanone did not react with other metals such as cobalt, cadmium, copper, manganese nickel, iron, lead and zinc, to form the complex. In this studies, we have also clarified Sindhwani and Singh's spectrophotometric determination data of various metals with acenaphthenequinone monooxime (Talanta 20,248, 1973), whose results were not correct.

  • PDF

Type IV 고세장비 모듈형 수소저장용기의 충전 조건에서의 수치해석적 연구 (A Numerical Analysis Study on Charging Conditions of Type IV High Aspect Ratio Modular Hydrogen Storage Vessel)

  • 백중택;문지훈;민지훈;박균범;기광택;주성욱
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.26-31
    • /
    • 2023
  • In this study, in order to propose a modular method for type IV high aspect ratio modular hydrogen storage vessel, a numerical analysis was conducted on the heat transfer behavior in series and parallel connection methods, and the differences according to each connection method were reviewed. Computational fluid dynamics software was used to check the internal temperature and pressure values of the hydrogen storage container under charging conditions. In terms of thermal safety when charging hydrogen gas, it was confirmed that the parallel modularization method was superior.

Synthesis, Spectroscopic Studies and Biological Applications of Organotin(IV) Derivatives of 3-[N-(4-Nitrophenyl)-amido]propenoic Acid and 3-[N-(4-Nitrophenyl)-amido]propanoic Acid

  • Shahid, Khadija;Shahzadi, Saira;Ali, Saqib;Mazhar, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권1호
    • /
    • pp.44-52
    • /
    • 2006
  • New organotin(IV) derivatives with general formulae R_2SnL_2 and R_3SnL, where R = methyl, n-butyl, n-octyl and phenyl and HL is either 3-[N-(4-nitrophenyl)amido]-propenoic acid or 3-[N-(4-nitrophenyl)amido] propanoic acid have been synthesized in 1 : 2 and 1 : 1 molar ratio by different methods. The FTIR spectra clearly demonstrated that the organotin(IV) moieties react with [O,O] atoms of the ligands. The bonding and coordination behavior in these complexes are discussed on the basis of multinuclear (^1H,\,^{13}C,\,^{119}Sn) NMR and mass spectrometric studies. Antibacterial, and antifungal screening tests were performed for these compounds and reported here. These values were compared to those of the precursors and it was found that diorganotin(IV) complexes exhibit less activity as compared to triorganotin(IV) complexes . LD_{50} data were obtained by Brine Shrimp assay method. Insecticidal activity was performed for selective compounds by contact toxicity method.

프로그래밍 언어가 소프트웨어 복잡도에 미치는 영향에 관한 연구 : FORTRAN IV와 FORTRAN 77, PASCAL과 C의 비교 (A Study on the effects of programming Languages on Software Complexity : Comparison of FORTRAN IV vs. FORTRAN 77 and PASCAL vs. C)

  • 윤정모
    • 대한산업공학회지
    • /
    • 제19권3호
    • /
    • pp.59-70
    • /
    • 1993
  • This paper presents the results of experiments which compare the software complexity between programming languages, i.e, FORTRAN IV and FORTRAN 77, PASCAL and C language, respectively. Each experiment is performed to compare the complexity between programs of same problems using Halstead's method based on operator, and McCabe's based on data flow. As the results of 25 test programs experiments, FORTRAN 77 languages shows superiority to FORTRAN IV languages, and C than that of PASCAL languages, in the aspect of the global software complexity.

  • PDF

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • 제3권1호
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

분광광도법에 의한 옥살산의 정량 (The Spectrophotometric Determination of Oxalic Acid with Zr(IV)-XO Complex)

  • 정우태;박면용;이병조;박기채
    • 대한화학회지
    • /
    • 제20권1호
    • /
    • pp.43-47
    • /
    • 1976
  • 염산 산성(1∼4N) 용액에서 Zr(IV)-XO 착물의 흡광도가 옥살산의 첨가량에 반비례하는 현상을 이용하여 미량의 옥살산을 정량하는 방법을 확립하였다. 말산, 말론산, 말레산, 후마르산, 숙신산, 엽산, 글루타민산은 옥살산량의 100배가 공존하여도 미량의 옥살산을 정량하는 데 방해하지 않지만 타르타르산과 시트르산은 옥살산 보다 많으면 방해한다.

  • PDF

3-수준계 Foldover Resolution IV 부분실험법의 통계적 구조 및 추가분석방법에 관한 연구 (A Study on the Statistical Structure and Additional Analysis of the 3-level Foldover Resolution IV Fractional Factorial Designs)

  • 김상익
    • 품질경영학회지
    • /
    • 제38권1호
    • /
    • pp.42-51
    • /
    • 2010
  • For the fractional factorial designs, the resolution-IV designs can be used when we want to estimate the main effects and to investigate the structure of the non-negligible two-factor interaction effects, when the three-factor and higher order interaction effects are all negligible. However we need to add the additional treatment combinations in order to identify the influential interactions for the resolution-IV fractional factorial designs. In this paper we investigate the statistical structure for 3-level resolution-IV designs constructed by fold-over scheme and introduce a method for analyzing the influential two-factor interactions.

Resolution IV $3^t$ 요인부분실험법의 축차 분석방법에 관한 연구 (A Study on the Sequential Analysis of Resolution IV $3^t$ Fractional Factorial Designs)

  • 김상익
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2010년도 춘계학술대회
    • /
    • pp.129-138
    • /
    • 2010
  • For the fractional factorial designs, the resolution-IV designs can be used when we want to estimate the main effects and to investigate the structure of the non-negligible two-factor interaction effects, when the three-factor and higher order interaction effects are all negligible. However we need to add the additional treatment combination in order to identify the influential interactions for the resolution-IV fracrtional factorial designs. In this paper we investigate the statistical structure for 3-level resolution-IV designs constructed by fold-over scheme and introduce a method for analyzing the influential two-factor interactions.

  • PDF