Reserpine 전처리가토(前處置家兎)에 있어서의 Bradykinin의 강압효과(降壓效果) (Depressor Effect of Bradykinin in Rabbits Pretreated with Reserpine.)

  • 김성근
    • 대한약리학회지
    • /
    • 제2권1호
    • /
    • pp.17-20
    • /
    • 1966
  • The blood pressure responses following repeated injection of bradykinin were observed in the unanesthetized rabbits or rabbits treated with reserpine (0.5mg/kg IV) 24 hours previously. Bradykinin (0.5ug/kg) was injected intravenously at 10 minutes intervals for 5 times. In both groups of rabbits no appreciable changes in the depressor responses to each injection of bradykinin were observed. In the rabbits pretreated with reserpine, however, the more pronounced depressor responses to bradykinin was elicited.

  • PDF

회전연료 분사시스템의 분무특성 (Spray Characteristics of the Rotating Fuel Injection System)

  • 이동훈;박정배;최성만
    • 한국분무공학회지
    • /
    • 제11권2호
    • /
    • pp.81-88
    • /
    • 2006
  • The spray characteristics of the rotating fuel injection system were investigated. The special test rig was devised to get the spatial and momentary droplet information. This experimental apparatus consists of a high-speed motor, a shaft, a rotating fuel nozzle and an acrylic case. Spray droplet size and velocity were measured by PDPA(Phase Doppler Particle Analyzer) and instantaneous velocity field was measured by 1'IV (Particle Image Velocimetry) system. At the same time, spray visualization was performed by using ND-YAG laser-based flash photography. From these two different laser diagnostic techniques, we could get spatial and instantaneous spray information fur rotating fuel injection system. The results presented in this paper indicate that spray characteristics such as droplet size, velocity and spray pattern were strongly influenced by rotational speed.

  • PDF

하우징 제품의 가스사출성형에 관한 연구 (A Study on Gas-assisted Injection Molding in Housing Molded Parts)

  • 이종원
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.131.2-135
    • /
    • 1999
  • This study focuses on part quality and cycle times under gas-assisted injection molding(GIM) of housing molded parts. The position of the gas channel was estabished near to parting line at the end of last locations to fill. Applied hot runner and valve gates the gas was introduced directly into the mold cavity via gas pin. As GIM was applied the introduced directly into the mold cavity via gas pin. As GIM was applied the conclusion reached as follows. I) The quality of appearance was improved by reducing sink marks and scratches of texture ii) The realibility was improved by preventing warpages and reinforcing rigidity through optimum gas channel layout iii)It is enable to use small size of injection molding machine step by step as GIM was accomplished low pressure and reduced clamp forces against CIM iv)The productivity were improved by reducing cycle times.

  • PDF

천마(Gastrodia elata Blume)의 항혈소판, 항혈전활성 (Anti-platelet and Anti-thrombotic Effects of Gastrodia elata)

  • 백영숙;송재경;윤춘희;정교순;윤혜숙
    • 생약학회지
    • /
    • 제26권4호
    • /
    • pp.385-389
    • /
    • 1995
  • MeOH extract of Gastrodia elata was fractionated to five solvent fractions, hexane fr (fr I), 90% MeOH fr (fr II), EtOAc fr (fr III), BuOH fr (fr IV) and $H_2O$ fr (fr V). Among the five fractions, fr II, III and IV showed platelet anti-aggregating effects against ADP or collagen induced rat platelet aggregation in vitro. Fr II , III and IV were also tested in vivo, in the mouse and rat models of thrombosis. Oral administration of fr II, III or IV enhanced the recovery from the thrombotic shock in the mouse model of thrombosis to 32-40% from 17% of recovery with the control group of mice. Treatment with fr II, III or IV also attenuated the sudden reduction in the blood platelet count following intravenous collagen injection to rat. The above results were indicative of the presence of anti-platelet and anti-thrombotic components in this plant.

  • PDF

Effects of Kanagawa Hemolysin on Blood Pressure and Arterial Tone in Rats

  • Kim, Young-Moon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권4호
    • /
    • pp.225-233
    • /
    • 2002
  • Kanagawa hemolysin (KH), an exotoxin produced from Kanagawa phenomenon-positive Vibrio parahemolyticus, has been shown to possess various biological activities including hemolysis, enterotoxicity, cytotoxicity, and cardiotoxicity. The aim of this study was to investigate the effect of KH on the cardiovascular system and its mechanism, employing in vivo and in vitro experiments of the rat. Intracerebroventricular (icv) administration of 100 mHU KH produced a marked and continuous pressor effect (icv KH-pressor effect), and the icv pressor effect was not repeatable. However, intravenous (iv) injection of the same dose of KH induced a prominent depressor effect (iv KH-depressor effect). The icv KH-pressor effect was inhibited by acid-denaturation, while the iv KH-depressor effect was not. Simultaneous icv administration of the three agents (ouabain, diltiazem, or bumetanide: $10{\mu}g/kg$ each) significantly reduced the pressor effect. The icv KH-pressor effect was inhibited by treatment with iv phentolamine or chlorisondamine, but was not affected by iv candesartan. The iv KH-depressor effect was repeatable and was attenuated by treatment with iv NAME or methylene blue. In vitro experiments using isolated thoracic aorta, $10^{-6}$ M phenylephrine (PE) and 50 mM KCl produced a sustained contraction. In rings contracted with either agents, KH showed relaxant responses in a concentration- dependent fashion and the relaxation (KH-vasorelaxation) was not dependent on the existence of the endothelium. The KH-vasorelaxation in the endothelium-intact rings contracted by PE was abolished by methylene blue treatment. In summary, the present findings suggest that in the icv KH-pressor effect the cation leak-inducing action of KH is implicated, which leads to the increased central sympathetic tone, that the iv KH-depressor effect results from the vasorelaxation via NO-guanylate cyclase system, and that the KH-vasorelaxation is independent of the endothelium and the guanylate cyclase system is involved in it. In conclusion, the mechanism of KH producing the icv pressor effect may not be identical to that of KH producing the iv depressor effect.

수액 소진 알람시스템을 위한 동일평면형 광센서의 연구 및 제작 (Optical Sensor of Coplanar Structure Study and Design for Intravenous Solution Exhaustion Alarm System)

  • 박효순;김태윤;정의성;성기웅;김명남;조진호
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.113-118
    • /
    • 2015
  • Intravenous (IV) infusion set is one of the most common treatment methods applied to hospitalized patients. However, it is necessary to check the injection of IV solution in order to prevent patients from any possible medical injuries. In this paper, using the optical sensors to detect exhaustion of IV solution was proposed. The optical sensor is coplanar structure composed of LED and photodiode which is installed according to focal distance of the lens. These two elements detect exhaustion of IV solution at the desired point conveniently. Through the results of experiments using various wavelength of LED (R.G.B), the blue LED was selected to the optimum light source. The suggested optical sensor can detect exhaustion of IV solution by the differences in the amount of light which is caused by properties such as total reflection, refractive index and scattering. From the implementation, the detector is applicable to both containers of IV solution, glass bottle and plastic pack. And also the result shows apparent differences according to existence of IV solution even if the IV solution color and illumination were changed.

백서 복직근피판의 허혈-재관류 손상에 대한 히스타민 차단제의 효과 (The Effects of Anti-Histamine and Mast Cell Stabilizer against Ischemia-Reperfusion Injury to TRAM Flap in Rat)

  • 강상윤;정윤규;심정연
    • Archives of Plastic Surgery
    • /
    • 제33권6호
    • /
    • pp.742-747
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the role of mast cell and histamine as typical product of mast cell in ischemia-reperfusion injury of muscle flap using H2 receptor blocker and mast cell stabilizer. Methods: Thirty-five Sprague-Dawley rats weighing 250-300 gm were divided into four groups; Group I: Control group without ischemia, Group II: Normal saline injection group with ischemia, Group III: Cimetidine injection group with ischemia, Group IV: Sodium cromoglycate injection group with ischemia. Well established single pedicled transverse rectus abdominis musculocutaneous(TRAM) flap was designed in all rats and were rendered ischemia by clamping the artery for 150 minutes. All injections were applied intramuscular around gluteal area 30 minutes before reperfusion. The flap survival was evaluated at 7 days after operation. Neutrophil counts and mast cell counts were evaluated 24 hours after reperfusion. Results: The difference of skin flap survival between control group and cimetidine injection group was not significant. In the normal saline injection group flap survival was markedly decreased compared to that of control group. The muscle flap survival was similar to the results of skin flap survival. The neutrophil counts were significantly decreased in control group and sodium cromoglycate injection group than normal saline injection group. The mast cell counts were significantly decreased in cimetidine injection group and control group than both normal saline injection and sodium cromoglycate injection groups. The protective effect of sodium cromoglycate was not seen in the skin flap, but the muscle flaps showed protective effects of sodium cromoglycate compared to normal saline injection group. Conclusions: It is suggests that commonly used antihistamine(H2 receptor blocker) has protective effect against ischemia-reperfusion injury to skin and muscle flaps by reducing neutrophil and mast cell. The mast cell stabilizer was not effective for skin flap but, possibly, for muscle flap.

Indirect Determination of Nitrite by Flame Atomic Absorption Spectrometry Using a Lead(IV) Dioxide Oxidant Microcolumn

  • Noroozifar, Meissam;Khorasani Motlagh, Mozhgan;Taheri, Aboozar;Homayoonfard, Marjan
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권6호
    • /
    • pp.875-880
    • /
    • 2006
  • A new, simple and fast flow injection analysis (FIA) method has been developed for the indirect determination of nitrite. The proposed indirect automatic method is based on the oxidation of nitrite to nitrate using a lead(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the $PbO_2$ solid phase reagent to Pb(II), which is measured by flame atomic absorption spectrometry. The absorbance of Pb(II) are proportional to the concentration of nitrite in the samples. The calibration curve was linear up to 30 mg $L ^{-1}$, with a detection limit of 0.11 mg $L ^{-1}$ for a 400 mL injected sample volume and a sampling rate of about 80 $h ^{-1}$. The results exhibit no interference from the presence of large amounts of ions. The developed procedure was found to be suitable for the determination of nitrite in foodstuffs and wastewaters. A relative standard deviation better than 0.9% was obtained in a repeatability study. The reliability of the method was established by parallel determination against the standard method.

양측 하악 매복지치 동시 발치를 위한 의식하 진정의 비교 연구: Propofol, Fentanyl과 Diazepam, Morphine (Propofol and Fentanyl Compared with Midazolam and Morphine for Conscious Sedation During Surgical Extraction of Bilateral Mandibular Impacted Third Molars)

  • 김영균;채병국;최현규
    • 대한치과마취과학회지
    • /
    • 제3권2호
    • /
    • pp.87-91
    • /
    • 2003
  • Background: The purpose of this study was to compare the availability of propofol and fentanyl (P + F) with diazepam and morphine (D + M) for intravenous conscious sedation during third molar surgery. Methods: Forty patients without systemic disease were operated under IV conscious sedation administered by either of the two techniques. Monitoring consisted of continuous observation of pulse rate, blood pressure, oxygen saturation, and the respiratory rate and were recorded every 15 minutes. Cooperation score was measured 5 and 15 minutes after induction of IV sedation. Following the operation, the surgeon and patients completed questionnaires including pain visual analog scale, amnesia, and side effects. Results: The P + F group was significantly more cooperative than the D + M group. The side effects of D + M group included pain on injection, nausea/vomiting and abdominal pain. The side effects of P + F group included talkativeness, nausea/vomiting, temporary apnea, pain on injection and vertigo. Conclusions: In this study, there were following benefits in the P + F group; more cooperative status and less pain perception. But respiratory depression developed in some patients.

  • PDF

119 구급대원의 근골격계 질환 위험성 평가 - 소방기술경연대회 구급종목을 대상으로 - (Evaluation of musculoskeletal disorders risk of 119 emergency medical technicians during emergency medical services procedures in firefighter combat challenge)

  • 손정원;박재범
    • 한국응급구조학회지
    • /
    • 제21권3호
    • /
    • pp.59-71
    • /
    • 2017
  • Purpose: The purpose of the study was to evaluate the ergonomic risk factors of 119 emergency medical technicians (EMT) with musculoskeletal disorders, performing emergency medical services (EMS) procedures in a firefighter combat challenge. Methods: The evaluated EMT procedures were cardiopulmonary resuscitation (CPR) & intubation, trauma patient assessment, and intravenous (IV) injection. Measurement of working posture was done during training. Results: In CPR & intubation, OWAS-score was 2 (mean 1.9, maximum 4), requiring correction action, while REBA-score was 11 (mean 7.28, maximum 11), requiring immediate improvement. In trauma patient assessment & IV injection, OWAS-score was 4 (mean 2.9, maximum 4), requiring immediate correction action, while the REBA score was 7 (mean 7.5, maximum 11), requiring improvement. Conclusion: Both OWAS score and REBA-score showed improvement of posture and high-risk of musculoskeletal disorders. Occupational health management in EMS procedures during combat challenge and effective injury prevention program in fire stations are warranted.