• Title/Summary/Keyword: IT control tower

Search Result 167, Processing Time 0.029 seconds

Active Control of Noise from Fan Blowers in Tower-type Air Conditioners (타워형 에어컨 송풍기 소음의 능동제어)

  • Ryu, Kyungwan;Hong, Chinsuk;Jeong, Wei Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.87-93
    • /
    • 2017
  • This paper investigates active noise control of tower-type air conditioners using the filtered-x least mean square (FXLMS) algorithm to reduce fan blower noise transmission. Firstly, the main components required for the active control system including the error sensor, the control speaker and the reference sensors are selected. Since the noise could significantly reduce if the reference signal includes every frequency response information, a various reference signals from accelerometers and a microphone are used. Secondly, the controller based on the FXLMS algorithm with a single-channel reference signal is implemented. Then, the control performance is examined experimentally for the different reference signals. It is found that the accelerometer signal well possesses the motor vibration related noise and a microphone signal could includes global noise. When using the reference signal with a microphone located near the motor and the fan blower, the active control system reduces the noise globally, except for several peaks.

Garments Waterproofness Test Using Rain Tower System (인공강우시스템을 활용한 의복의 방수성능 평가)

  • Cha, Hee Chul;Park, Jun Ho;Lim, Jee Young;Shim, Huen Sup
    • Fashion & Textile Research Journal
    • /
    • v.17 no.6
    • /
    • pp.1013-1019
    • /
    • 2015
  • As the interest in leisure and health increases, the domestic outdoor wear industry becomes bigger. The waterproofness of fabrics does not ensure the waterproofness of garments because of the stitch holes during the sewing process even with the seam sealing tapes. Thus the water leakage often becomes a problem during the end use. Still companies use fabrics waterproofness data for garments marketing because they are simple to run the test, less expensive than the whole garment testing, and easy to achieve the quality control. In this study the rain tower system for evaluating the waterproofness of garments has been developed and the waterproofness of the selected waterproof and breathable garments in the market were tested. The rain tower was consisted of rain tower room, rainfall forming system and measurement system. Two different levels of rainfall can be simulated with this system(100l/m2/hr and 450l/m2/hr). Jackets in the market have been tested at two different rainfall conditions. The temperature and humidity data inside jackets didn't provide much information on the waterproofness at severe rainfall condition(450l/m2/hr, 1 hour). However, water leakage was detected on the cotton undershirt inside jacket. 5 out of 8 jackets passed the normal rainfall condition(100l/m2/hr, 30 minutes). The newly developed rain tower system was able to evaluate the waterproofness of the jacket seams. It is recommended the further study on the detailed test conditions for the end use of the waterproof and breathable garments.

Elastoplastic FEM analysis of earthquake response for the field-bolt joints of a tower-crane mast

  • Ushio, Yoshitaka;Saruwatari, Tomoharu;Nagano, Yasuyuki
    • Advances in Computational Design
    • /
    • v.4 no.1
    • /
    • pp.53-72
    • /
    • 2019
  • Safety measures for tower cranes are extremely important among the seismic countermeasures at high-rise building construction sites. In particular, the collapse of a tower crane from a high position is a very serious catastrophe. An example of such an accident due to an earthquake is the case of the Taipei 101 Building (the author was the project director), which occurred on March 31, 2002. Failure of the bolted joints of the tower-crane mast was the direct cause of the collapse. Therefore, it is necessary to design for this eventuality and to take the necessary measures on construction sites. This can only be done by understanding the precise dynamic behavior of mast joints during an earthquake. Consequently, we created a new hybrid-element model (using beam, shell, and solid elements) that not only expressed the detailed behavior of the site joints of a tower-crane mast during an earthquake but also suppressed any increase in the total calculation time and revealed its behavior through computer simulations. Using the proposed structural model and simulation method, effective information for designing safe joints during earthquakes can be provided by considering workability (control of the bolt pretension axial force and other factors) and less construction cost. Notably, this analysis showed that the joint behavior of the initial pretension axial force of a bolt is considerably reduced after the axial force of the bolt exceeds the yield strength. A maximum decrease of 50% in the initial pretension axial force under the El Centro N-S Wave ($v_{max}=100cm/s$) was observed. Furthermore, this method can be applied to analyze the seismic responses of general temporary structures in construction sites.

A Study on Off-Gas Treatment of an Air Stripping Tower Using a Plasma Reactor

  • Lim, Gye-Gyu;Yoo, Ho-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.382-389
    • /
    • 1993
  • An evaluation of a plasma reactor was conducted to investigate its potential as a feasible and economical off-gas control technology for an air stripping tower (AST). The plasma reactor was powered by an alternating current with frequencies up to 1000Hz. The study showed that over 90% conversion of gas-phase trichloroethylene (TCE) can be achieved. An optimum frequency for the laternating current existed for maximum power input. The optimum frequency was dependent on the reactor geometry and the primary voltage applied. for a fixed geometry, a plasma reactor has a limited capacity for flow rate. Even though it is a feasible process to control off-gases, further investigations should be conducted to develop a more economic process.

  • PDF

Revisiting the "T" in TMD

  • Strobel, Kurt;Salcedo, Victor
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.2
    • /
    • pp.109-116
    • /
    • 2021
  • This paper explores the meaning and importance of tuning amongst other Tuned Mass Damper (TMD) parameters and describes processes to help ensure that an as-built TMD is properly tuned to the as-built high-rise building. A summary of key TMD components and TMD implementations will be presented as an introduction and review. Next, it will be shown that tuning is a means for optimizing TMD performance. A process using modal characterization tests during tower construction to estimate natural frequencies of the completed tower will be described. Finally, the use of a Frequency Response Function (FRF) as a means for verifying the frequency of a TMD will be proposed.

Establishing an Effective Governance System Is the Top Priority in Securing Competitiveness in the Biohealth Industry (바이오헬스정책, 거버넌스 구축이 최우선 과제이다)

  • Sun-Hee Lee
    • Health Policy and Management
    • /
    • v.33 no.4
    • /
    • pp.377-378
    • /
    • 2023
  • The Yoon Suk Yeol administration is promoting the "Global Leap of the Biohealth Industry" as one of its 120 key national policies. Recently, the administration has been showing its commitment by establishing various strategies and presenting blueprints for policy implementation. However, the results felt on the ground are still not sufficient. The biohealth industry is a difficult field to generate policy effects because the related regulations are intricately intertwined and the diverse administrative tasks are scattered in various government departments, where inter-departmental interests differ. To solve this problem, an innovative governance system should be established. In order for the government's recent approach to establish a government-wide control tower to be effective, it should demonstrate a proactive policy commitment and be given practical power to coordinate the interests between departments.

A Study on Factors Affecting the Supply of Apartments in Changwon City (창원시 아파트 공급량에 영향을 미치는 요인에 관한 연구)

  • Sung, Joo-Han
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.35-50
    • /
    • 2020
  • The purpose of this study is to examine which factors are important in determining the amount of the apartment supply in Changwon City. Additionally, this study is to examine the changes in the determination of the amount of apartment supply in Changwon by dividing it into before and after 2016 as the city showed a large difference in apartment supply that caused structural changes during this time period. This study shows that the increase in the number of housing construction permits in Changwon before 2016 had a negative impact on the housing market as well as causing a decrease in the supply of apartments in Changwon after 2016. As a result of the shortsighted predictions on the housing market of Changwon from before 2016, it still affects the current housing market as of June 2020. The implication of this study is that through the housing market system of Changwon City, they can take the role as a control tower in Changwon City and propose principles and standards for supply control in order to better predict the demand of the housing market.

Design of Power and Load Reduction Controller for a Medium-Capacity Wind Turbine (중형 풍력터빈의 출력 및 타워 하중저감 제어기 설계)

  • Kim, Kwansu;Paek, Insu;Kim, Cheol-Jin;Kim, Hyun-Gyu;Kim, Hyoung-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.1-12
    • /
    • 2016
  • A control algorithm for a 100 kW wind turbine is designed in this study. The wind turbine is operating as a variable speed variable pitch (VSVP) status. Also, this wind turbine is a permanent magnet synchronous generator (PMSG) Type. For the medium capacity wind turbine considered in this study, it was found that the optimum tip speed ratios to achieve the maximum power coefficients varied with wind speeds. Therefore a commercial blade element momentum theory and multi-body dynamics based program was implemented to consider the variation of aerodynamic coefficients with respect to Reynolds numbers and to find out the power and thrust coefficients with respect tip speed ratio and blade pitch angles. In the end a basic power controller was designed for below rated, transition and above rated regions, and a load reduction algorithm was designed to reduce tower vibration by the nacelle motion. As a result, damage equivalent Load (DEL) of tower fore-aft has been reduced by 32%. From dynamic simulations in the commercial program, the controller was found to work properly as designed. Experimental validation of the control algorithm will be done in the future.

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

Development of a new free wake model using finite vortex element for a horizontal axis wind turbine

  • Shin, Hyungki;Park, Jiwoong;Lee, Soogab
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.17-27
    • /
    • 2017
  • The treatment of rotor wake has been a critical issue in the field of the rotor aerodynamics. This paper presents a new free wake model for the unsteady analysis for a wind turbine. A blade-wake-tower interaction is major source of unsteady aerodynamic loading and noise on the wind turbine. However, this interaction can not be considered in conventional free wake model. Thus, the free wake model named Finite Vortex Element (FVE hereafter) was devised in order to consider the interaction effects. In this new free wake model, the wake-tower interaction was described by dividing one vortex filament into two vortex filaments, when the vortex filament collided with a tower. Each divided vortex filaments were remodeled to make vortex ring and horseshoe vortex to satisfy Kelvin's circulation theorem and Helmholtz's vortex theorem. This model was then used to predict aerodynamic load and wake geometry for the horizontal axis wind turbine. The results of the FVE model were compared with those of the conventional free wake model and the experimental results of SNU wind tunnel test and NREL wind tunnel test under various inflow velocity and yaw condition. The result of the FVE model showed better correlation with experimental data. It was certain that the tower interaction has a strong effect on the unsteady aerodynamic load of blades. Thus, the tower interaction needs to be taken into account for the unsteady load prediction. As a result, this research shows a potential of the FVE for an efficient and versatile numerical tool for unsteady loading analysis of a wind turbine.