• Title/Summary/Keyword: IT Use

Search Result 50,631, Processing Time 0.084 seconds

A Mutual P3P Methodology for Privacy Preserving Context-Aware Systems Development (프라이버시 보호 상황인식 시스템 개발을 위한 쌍방향 P3P 방법론)

  • Kwon, Oh-Byung
    • Asia pacific journal of information systems
    • /
    • v.18 no.1
    • /
    • pp.145-162
    • /
    • 2008
  • One of the big concerns in e-society is privacy issue. In special, in developing robust ubiquitous smart space and corresponding services, user profile and preference are collected by the service providers. Privacy issue would be more critical in context-aware services simply because most of the context data themselves are private information: user's current location, current schedule, friends nearby and even her/his health data. To realize the potential of ubiquitous smart space, the systems embedded in the space should corporate personal privacy preferences. When the users invoke a set of services, they are asked to allow the service providers or smart space to make use of personal information which is related to privacy concerns. For this reason, the users unhappily provide the personal information or even deny to get served. On the other side, service provider needs personal information as rich as possible with minimal personal information to discern royal and trustworthy customers and those who are not. It would be desirable to enlarge the allowable personal information complying with the service provider's request, whereas minimizing service provider's requiring personal information which is not allowed to be submitted and user's submitting information which is of no value to the service provider. In special, if any personal information required by the service provider is not allowed, service will not be provided to the user. P3P (Platform for Privacy Preferences) has been regarded as one of the promising alternatives to preserve the personal information in the course of electronic transactions. However, P3P mainly focuses on preserving the buyers' personal information. From time to time, the service provider's business data should be protected from the unintended usage from the buyers. Moreover, even though the user's privacy preference could depend on the context happened to the user, legacy P3P does not handle the contextual change of privacy preferences. Hence, the purpose of this paper is to propose a mutual P3P-based negotiation mechanism. To do so, service provider's privacy concern is considered as well as the users'. User's privacy policy on the service provider's information also should be informed to the service providers before the service begins. Second, privacy policy is contextually designed according to the user's current context because the nomadic user's privacy concern structure may be altered contextually. Hence, the methodology includes mutual privacy policy and personalization. Overall framework of the mechanism and new code of ethics is described in section 2. Pervasive platform for mutual P3P considers user type and context field, which involves current activity, location, social context, objects nearby and physical environments. Our mutual P3P includes the privacy preference not only for the buyers but also the sellers, that is, service providers. Negotiation methodology for mutual P3P is proposed in section 3. Based on the fact that privacy concern occurs when there are needs for information access and at the same time those for information hiding. Our mechanism was implemented based on an actual shopping mall to increase the feasibility of the idea proposed in this paper. A shopping service is assumed as a context-aware service, and data groups for the service are enumerated. The privacy policy for each data group is represented as APPEL format. To examine the performance of the example service, in section 4, simulation approach is adopted in this paper. For the simulation, five data elements are considered: $\cdot$ UserID $\cdot$ User preference $\cdot$ Phone number $\cdot$ Home address $\cdot$ Product information $\cdot$ Service profile. For the negotiation, reputation is selected as a strategic value. Then the following cases are compared: $\cdot$ Legacy P3P is considered $\cdot$ Mutual P3P is considered without strategic value $\cdot$ Mutual P3P is considered with strategic value. The simulation results show that mutual P3P outperforms legacy P3P. Moreover, we could conclude that when mutual P3P is considered with strategic value, performance was better than that of mutual P3P is considered without strategic value in terms of service safety.

Analysis of the Causes of and Risk Factors for Mortality in the Surgical Repair of Interrupted Aortic Arch (대동맥궁 단절증 수술 사망 원인과 위험인자 분석)

  • Kwak Jae Gun;Ban Ji Eun;Kim Woong-Han;Jin Sung Hoon;Kim Yong Jin;Rho Joon Ryang;Bae Eun Jung;Noh Chung Il;Yun Yong Soo;Lee Jeong Ryul
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.99-105
    • /
    • 2006
  • Background: Interrupted aortic arch is a rare congenital heart anomaly which still shows high surgical mortality. In this study, we investigated the causes of and the risk factors for mortality to improve the surgical outcomes for this difficult disease entity. Material and Method: From 1984 to 2004, 42 patients diagnosed as IAA were reviewed retrospectively. Age, body weight at operation, preoperative diagnosis, preoperative PGE1 requirement, type of interrupted aortic arch, degree of left ventricular outflow stenosis, CPB time, and ACC time were the possible risk factors for mortality. Result: There were .14 hospital deaths. Preoperative use of PGE1, need for circulartory assist and aortic cross clamp time proved to be positive risk factors for mortality on univariate analysis. Preoperative left ventricular outflow stenosis was considered a risk factor for mortality but it did not show statistical significance (p-value=0.61). Causes of death included hypoxia due to pulmonary banding, left ventricular outtract stenosis, infection, mitral valve regurgitation, long cardiopulmonary bypass time and failure of coronary transfer failure in TGA patients. Conclusion: In this study, we demonstrated that surgical mortality is still high due to the risk factors including preoperative status and long operative time. However preoperative subaortic dimension was not related statistically to operative death statistically. Adequate preoperative management and short operation time are mandatory for better survival outcome.

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Correlation between 5-Minute $^{99m}Tc-Pertechnetate$ Uptake and 24-Hour $^{131}I$ Uptake in Patients with Thyroid Disease (갑상선환자에서의 5분 $^{99m}Tc-Pertechnetate$ 섭취율과 방사성옥소섭취율의 상관관계)

  • Lee, Chan-Woo;Won, Kyu-Chang;Yoon, Hyun-Dae;Cho, In-Ho;Kim, Tae-Nyeun;Shin, Dong-Gu;Lee, Hyoung-Woo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.280-289
    • /
    • 1992
  • The 20-minute $^{99m}Tc-pertechnetate$ uptake became readily available for routine use and it replaced $^{131}I$ for thyroid imaging. However measuring thyroid uptake during a 5-minute minimizes pertechnetate uptake by the salivary glands and presence of contaminated saliva from those glands in to the pharynx and esophagus. A study was carried out to determine the suitability of the utility of a S-minute and 20-minute interval from administration of $^{99m}Tc-pertechnetate$ to imaging and uptake measurement as a replacement for the 24 hour standard originally established with $^{131}I$, and to evaluate the relationship between 5-minute $^{99m}Tc-pertechnetate$ uptake and other thyroid functions. A 5-minute and 20-minute uptake of $^{99m}Tc-pertechnetate$ were measured in 70 patients with thyroid disease at Yeungnam University Hospital from March 1, 1991 to Feb. 29, 1992. The results were as follows. 1) The 5-minute $^{99m}Tc-pertechnetate$ uptake in Graves' disease, Hashimoto's thyroiditis, simple goiter, non toxic nodular goiter, subacute thyroiditis and euthyroid were 18.2%, 14.6%, 2.8%, 3.2%, 1.2% and 1.1%, respectively. There was a significant difference between the mean of the euthyroid group and the mean of the Graves' disease. So differenciation between them can be easily made. 2) The 5 minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with 24 hour $^{131}I$ thyroid uptake (r=0.75, p<0.001). These data provided an equation for estimating the 24 hour uptake of iodide given the 5 minute pertechnetate uptake: Estimated 24-hour $^{131}I$ thyroid Uptake= 7.188*ln (5 minute $^{99m}Tc-pertechnetate$ uptake)+16.94 3) The 20-minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with 24-hour $^{131}I$ uptake (r=0.72, p<0.001) and 5-minute $^{99m}Tc-pertechnetate$ thyroid uptake (r=0.96, p<0.001). 4) In the Graves' disease, The 5-minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with serum $T_3-resin$ uptake (r=0.46, p<0.01), serum total $T_3$ (r=0.55, p<0.05), serum total $T_4$ (r=0.46, p<0.05). These results suggest that 5-minute ${99m}Tc-pertechnetate$ thyroid uptake has been found at least as useful as 24-hour $^{131}I$ uptake for diagnostic confirmation at our hospital, the logistical advantages of completing the diagnosis. The exam in 5-minutes led us to abandon the 24-hour study in the majority of patients, but the 24-hour $^{131}I$ uptake is still obtained in patients with planned or potential radioiodine therapy.

  • PDF

Patient-related Barriiers to Pain Management in General Population (일반인의 통증관리 장애정도)

  • Yoo, Yang-Sook;Choe, Sang-Ok;Cho, Young-Yi;Koh, Su-Jin;Hor, Soo-Jin;Jeon, Ji-In;Kwon, So-Hi
    • Journal of Hospice and Palliative Care
    • /
    • v.10 no.4
    • /
    • pp.184-189
    • /
    • 2007
  • Purpose: This study was to explore barriers to effective pain management in general population. Methods: Total 163 Participants completed the Barrier Questionnaire-II (BQ-II), a 27-item on a six point scale, from May to June in 2007. BQ-II consisted of four subscales which were 1) physical effects (PE) addressing beliefs that side effects of analgesics are inevitable and concerns about tolerance, fatalism (Fa) addressing fatalistic beliefs about cancer pain and its management, Communication (Co) addressing the beliefs of 'good patient' and concerns of distracting physician from underlying disease, and harmful effects (HE) addressing fear of addiction and harmful effect to immune system of pain medicine. Results: The BQ-II total had an internal consistency of 0.877 in this study. HE was the biggest barrier (3.03) followed by PE (2.73), Fa (2.15), and Co (1.71). Items appeared as great concerns were 'there is a danger of becoming addicted to pain medication'(3.58), 'using pain medicine blocks your ability to know if you have any new pain' (3.18), 'pain medicine is very addictive' (3.09), 'when you use pain medicine your body becomes used to its effects and pretty soon it won't work any more' (3.09), and 'drowsiness from pain medicine is difficult to control' (3.09). Only 12 respondents (7.4%) reported that they took any type of pain education, however, those who took pain education represented significantly lower barriers to pain management than who did not (P=.029). Conclusion: This result suggests the strategies for public education to surmount cancer pain.

  • PDF

Comparative Analysis of Nutrients and Hazardous Substances in Zophobas atratus Larvae (탈지 전, 후 아메리카왕거저리(Zophobas atratus) 유충의 영양성분 및 유해물질 비교분석)

  • Kim, Sun Young;Kim, Hong Geun;Ko, Hyeon-Jin;Kim, Mi Ae;Kim, In Woo;Seo, Minchul;Lee, Joon Ha;Lee, Hwa Jeong;Baek, Minhee;Hwang, Jae Sam;Yoon, Hyung Joo
    • Journal of Life Science
    • /
    • v.29 no.12
    • /
    • pp.1378-1385
    • /
    • 2019
  • The nutritional composition and optimal eating stage of the super mealworm, Zophobas atratus (Coleoptera : Tenebrionidae), were investigated to explore its use as a food ingredient. It was determined that 10th instar larvae were most suitable for eating in terms of nutritional value as well as economic aspects. To improve the quality of powder production, the nutritional value of 10th instar larvae before and after degreasing was analyzed. After drying the larvae powder, crude protein was the most abundant nutrient both before (52.3%) and after (60.6%) degreasing while crude fat measured 36.3% and 21.7% before and after degreasing, respectively. In terms of essential amino acids, leucine levels were highest and 1.3 times greater after degreasing (4.5%) than before (3.5%). Oleic acid, the highest unsaturated fatty acid in larvae, was 31.7% after degreasing which was 1.1 times higher than before (33.2%). Among various major minerals, potassium was most abundant and 1.4 times higher after degreasing (1267.0 mg/100 g) than before (879.3 mg/100 g). Harmful substances were 1.3 to 2.0 times lower in the degreased larvae, although mercury or pathogenic bacteria were not detected in either group. We therefore conclude that degreased Z. atratus larvae are more suitable for eating than before degreasing.

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

Troposhperic Ozone Pollutions in Korea during 1998-2002 Using Two Ozone Indices for Vegetation Protection (식생보호를 위한 한계농도 누적 지표로 본 1998-2002년도의 우리나라 대기권 오존 오염)

  • 윤성철;김보선
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.1
    • /
    • pp.38-48
    • /
    • 2004
  • Tropospheric ozone data in Korea for 1998-2002 were analyzed to assess the impact on vegetation. SUM06(sum of hourly concentrations at or above 0.06 ppm) and AOT40(accumulated exposure over a threshold of 40 ppb), widely used as ozone indices in the U.S. and Europe, were calculated based on hourly ozone concentration in 612 areas during 1998-2002 in Korea. SUM06 of the highest 30 areas were 5-12 ppm/hr which were almost the same levels of the U.S. average, and a crop loss of 5% would be expected. Ozone pollution in Seoul during 1998-2002 had decreased compared to that for 1990-97 except in the Northern area; however, ozone pollution in Kyunggi during 1998-2002 had been increased twice compare to the previous 5 years. Korea was divided into four regions: Seoul Metropolitan area, Jungbu, Honam, and Youngnam. Ozone pollution in the Seoul Metropolitan area was much higher during 1998-2000 than the other areas, but ozone pollution during 2001-2002 was almost the same in all four regions. Chunnam-Kwangyang na Kyungbuk-Gumi, famous industrial complexes in southern Korea, were significant ozone pollution areas. However, other industrial complexes, such as Incheon, Ulsan, and Kyunggi-Sihwa, were not polluted compared to their neighbors. Comparing all ozone indices, SUM06(yr), SUM06(3mon), AOT40(yr), AOT40(3mon), number of hours exceeding 100 ppb, 95 percentile, 99 percentile, and maximum concentration, it was determined reasonable to use SUM06(3mon), AOT40(3mon) and number of hours exceeding 100 ppb for evaluation of the chronic impact of ozone on vegetation.