• Title/Summary/Keyword: IT Efficiency

Search Result 24,604, Processing Time 0.06 seconds

Cleaning Effect of Papermaking Felt with Enzymes (효소에 의한 초지용 펠트의 세척효과)

  • Yoon, Byung-Tae;Kim, Seong-Bo;Eom, Tae-Jin;Choi, Myoung-Jae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.3
    • /
    • pp.17-22
    • /
    • 2005
  • The cleaning efficiency of papermaking felt which is contaminated with fiber fines and various micro-materials was investigated and compared between the application of enzyme and commercial detergent. It was found that the cleaning efficiency by the treatment of acidic-based detergent was more efficient than that of alkaline-based one in the conventional commercial detergent. it was also observed that the treatment design of first acidic-based detergent treatment to second alkaline-based detergent procedure was better in the cleaning efficiency, compared to alkaline based-to-acidic based one. The cleaning property of felt with enzyme was resulted in good cleaning efficiency, without any addition of surfactant. Especially, the enzyme treatment under alkaline condition (pH 10) showed a better cleaning result than that under acidic condition(pH 5). The addition of nonionic surfactant to the enzyme increased the cleaning efficiency of felt and decreased the cationic demand of wastewater. These results showed more favour than the application of conventional commercial detergent.

A Study on the Enhancement of Cooling Efficiency for the Cabinet of Automatic Controller in the Interior of Industrial Building (산업용 건축물 내 자동제어반의 냉각효율 향상에 관한 연구)

  • Kim, Soon-Ho;Park, Hyun-Jung
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.79-87
    • /
    • 2013
  • The improvement of cooling efficiency for the cabinet of automatic controller is the most efficient method of it's application. Therefore, this study has been analyzed and investigated the improvement of cooling efficiency and reduction of energy for the cabinet of automatic controller, respectively. So this study was conducted to enhancement of cooling efficiency for the cabinet of automatic controller by making a structure which produces difference of air pressures in the entrance tube of external air. And the structure has capacity of the pyrogen source (PTC elements) to make temperature range from $145^{\circ}C$ to $155^{\circ}C$. Consequently, temperatures of the upper, the lower in the interior of the cabinet of automatic controller and the exhaust part were revealed $28.57^{\circ}C$, $23.38^{\circ}C$and $36.14^{\circ}C$(average temperature of the exhaust part in case of existing method : $45^{\circ}C$) in target test of this study, respectively. It was found that the cabinet of the automatic controller has better cooling ability than the cabinet of automatic controller by using an existing method.

A Study on Correlation between Improvement in Efficiency of PV and Green roof of Public Building (공공건물 옥상녹화와 설치태양광(PV)의 효율향상 상관관계 연구)

  • Lee, Eung Jik
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.111-118
    • /
    • 2013
  • This study aims to investigate advantages of complex installation of green roof and PV system in a public building, to analyze the impact of green roof on the efficiency of PV power generation, and to consider the correlation between green roof and PV power generation. When the temperature and power generation of the modules installed in the green roof and non-green roof of the public building were measured for 3 days, the average temperature of the green roof was 23.6 degrees, and it was 36.1 degrees in the non-green roof which increased by nearly 53%. Overall, the module temperature in the green roof was lower. On the other hand, in relation to the PV generation depending on temperature reduction during the same period, the mono-crystalline module and the poly-crystalline module in the green roof showed an increase in generation at nearly 222.2W and 341.6W, and the efficiency rose by 5.5% and 6.2%, respectively, compared to the modules in the non-green roof. Therefore, it is analyzed that green roof has a positive influence on PV power generation. Finally shows the efficiency of the installed on the Green Roof PV system (complex Installation) higher than on the concrete roof PV system. Thus, the complex PV systems as well as the usual benefits of green roofs will provide greater synergies.

A Study of the Effect of Compressor Performance Map on the Efficiency of High-pressure Operating PEMFC Systems in Automotive Applications (압축기 성능 맵이 자동차용 가압형 고분자전해질형 연료전지 시스템 효율에 미치는 영향 연구)

  • Cho, Donghoon;Kim, Han-Sang
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.6
    • /
    • pp.604-611
    • /
    • 2012
  • For the commercialization of fuel cell powered vehicle, it is highly important to improve the performance and efficiency of an automotive polymer electrolyte membrane fuel cell (PEMFC) system. The performance and efficiency of PEMFC systems are significantly influenced by their operating conditions. Among these conditions, the system operating pressure is considered as the one of the main factors. In this study, to investigate the effects of operating pressure on the performance and efficiency of automotive PEMFC systems, two types of high-pressure operating PEMFC systems adopting two different compressors (i. e. different performance maps) are modeled by using MATLAB/Simulink environment. The PEMFC system efficiency and parasitic compressor power are mainly analyzed and compared for the two types of high-pressure operating PEMFC systems under the same system net power conditions. It is expected that this kind of study can contribute to provide basic insight into the operating strategies of high-pressure operating PEMFC systems for automotive use.

Measuring Efficiency of Korean Fund Operation Company using DEA (DEA 모형을 이용한 국내 펀드 운용사의 효율성 분석)

  • Kim, Jong-Ki;Kang, Da-Yeon;Park, Ki-Woon;Park, Je-Hun;Ok, Seok-Jae
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.4
    • /
    • pp.173-182
    • /
    • 2008
  • It is hard environment to get a profit without active invest due to the low interest. In this kind of environment, however, it is also difficult to find good company directly. So private investors is hard to succeed in comprehensive financial environment. Analyzing efficiency is necessary to enhance the competitive power of fund companies. This paper analyze the efficiency of fund company using DEA models. We evaluate the CCR and BCC efficiency and RTS(return to scale) of 33 Korean fund companies. We also suggest the fund company which can be benchmarked based on analyzed information.

Assessment of Attraction Efficiency of By-pass Fishway at Dalseong Weir According to Operating Attraction Waterway (유인수로의 운영에 따른 달성보 인공하도식 어도의 유인효율 평가)

  • Park, Ji Hyun;Ku, Young Hun;Baek, Kyong Oh;Kim, Young Do
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • In this study, the attraction efficiency of the by-pass fishway installed at Dalseong Weir in Nakdong River was assessed according to operation of the attraction waterway by using River2D which is a two-dimensional physical habitat simulation model. The model was calibrated and validated through the measured water elevation. The attraction efficiency of the fishway was evaluated at the low flow condition because the target fish, Zacco platypus (Z. platypus), have moved frequently up and downstream at the spawning season from April to June. From simulation results, it can be deduced that the attraction efficiency at situation of open attraction waterway is superior to that of close attraction waterway. Also it is shown that velocity field at inner region of the fishway is suitable for migration of the fish.

Comparison of Calibrations using Modified SWAT Auto-calibration Tool with Various Efficiency Criteria (다양한 검증 지수를 이용한 SWAT 자동 보정 비교 평가)

  • Kang, Hyun-Woo;Ryu, Ji-Chul;Kim, Nam-Won;Kim, Seong-Joon;Engel, Bernard A.;Lim, Kyoung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.19-19
    • /
    • 2011
  • The appraisals of hydrology model behavior for flow and water quality are generally performed through comparison of simulated data with observed ones. To perform appraisal of hydrology model, some criteria are often used, such as coefficient of determination ($R^2$), Nash and Sutcliffe model efficiency coefficient (NSE), index of agreement (d), modified forms of NSE and d, and relative efficiency criteria NSE and d. These criteria are used not only for hydrology model estimations also for various comparisons of two data sets; This NSE has been often used for SWAT calibration. However, it has been known that the NSE value has some limitations in evaluating hydrology at watersheds under monsoon climate because this statistic is largely affected by higher values in the data set. To overcome these limitations, the SWAT auto-calibration module was enhanced with K-means clustering and direct runoff/baseflow modules. However the NSE is still being used in this module to evaluate model performance. Therefore, the SWAT Auto-calibration module was modified to incorporate alternative efficiency criteria into the SWAT K-means/direct runoff-baseflow auto-calibration module. It is expected that this enhanced SWAT auto-calibration module will provide better calibration capability of SWAT model for all flow regime.

  • PDF

Chitosan as a Flocculant: An Approach to Improve its Solubility for Efficient Harvesting of Microalgae

  • Sajjad, Attia;Rizwan, Muhammad;Mujtaba, Ghulam;Rashid, Naim
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.530-534
    • /
    • 2017
  • Chitosan is a promising flocculant for microalgae harvesting, but its scale-up application is not economically supported yet. Low solubility of chitosan in microalgae suspension demands high dosage (as a flocculant) to destabilize the cells, and thus, increases the cost of microalgae harvesting. This study identifies efficient solvents for the chitosan, and optimizes the concentration of solvents and chitosan dose to improve the harvesting efficiency. Chitosan was dissolved in different acids, and subsequently used as a flocculant. The flocculant efficacy was measured in terms of harvesting efficiency and reduction in chemical oxygen demand (COD) of the microalgae suspension. It was found that chitosan dissolved in 0.05 M HCl showed the highest harvesting efficiency ($89{\pm}0.87%$) at only 30 mg/L of dosage. In comparison, 270 mg/L of $FeCl_3{\cdot}6H_2O$ was required to attain $86{\pm}0.083%$ of the harvesting efficiency. $H_2SO_4$ dissolved chitosan required high flocculant dose (150 mg/L) and resulted in relatively low harvesting efficiency ($77{\pm}0.11%$). It was concluded that the efficacy of chitosan is solvent dependent, and the selection of proper solvent can decrease the dosage requirement for microalgae harvesting.

A Study on Constructed Wetland Ecological Park Design with Multiple-cell FWS Layout -focus on Structural Design of Sustainable Structured wetland Biotope(SSB) Park- (자유수면형 인공습지 환경·생태공원 설계 -생태적 수질정화비오톱 공원의 구조설계를 중심으로-)

  • Byeon, Wooil
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.5
    • /
    • pp.1-9
    • /
    • 2006
  • The purpose of this study is to make a design guideline in designing constructed wetland which can treat water quality both of point and nonpoint source water pollution. It focuses on structural aspects of two case studies of constructed wetland applying SSB(Sustainable Structured wetland Biotope) system in Korea. The constructed wetland of Lake Ju-am which was constructed in 2002 by Environmental Management Corporation, was designed by applying SSB system. It shows higher removal efficiency than expected - 56% of BOD removal efficiency, 60% of T-N removal, and 76% of T-P removal efficiency. In two cases, total wetland areal extents were calculated referred to treatment efficiency. The system is consist of micro-cell structures : inflow channel, forebay, multiple wetland cells and micro-pool. When designing constructed wetland appropriate in local area, the total organic system of vertical and horizontal structure : geology, hydrology, land use, and ecological surroundings of the sites should be considered totally.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.