• Title/Summary/Keyword: IT Device

Search Result 11,997, Processing Time 0.045 seconds

A Study on DID Implementation for Wireless Calling System using Smart-device (스마트 기기를 이용한 무선호출용 DID구현에 대한 연구)

  • Cho, Youngseok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • In this time, as an industrial society developed to a welfare society, more and more people want their quality of lives upgraded and specially customized service by mass production/mass consumption. And it leads to an increase of requiring service. There're active developments and studies on various IT equipment as the requirement made IT devices used in service. In this paper, we try to design and realize radio paging DID by using smart device to be used as a receiver of a radio pager which is broadly used at face to face service. Firstly, we used MCU to design and implement Wireless Calling Gateway which change radio calling signal of ISM band to smart device. A receiver of wireless caller used original receiver module. Also it used bluetooth module to communicate with smart device. It was possible to have satisfactory communication since radio paging signal converter and smart device were linked in 3M. Secondly, to indicate various paging information delivered from a radio pager, we realized DID application program by using Smart PAD. As a result, we could indicate various information compared to an original receiver which only could indicate letters or numeric data. Secondly, we implemented the DID app for wireless calls that can display a variety of information sent from a wireless pager. Was implemented using the Smart Pad. As a result, it is shown that can display a variety of information than the existing receiver.

Portable RTOS Character LCD Device Driver (이식 가능한 RTOS용 Character LCD 디바이스 드라이버)

  • Hong, Jung-Hwan
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.153-158
    • /
    • 2006
  • A device driver is the core construction providing connectable rules between a hardware and an operating system in Embedded softwares. It provides consistent interface for the control and mutual interactions so that an application program can use hardware's functionalities. However, the device driver is suffered to develop as it is related to both hardware and software and it is also wasted to newly develop whenever hardware platform changed. Therefore, this paper researches the method to provide high portability in heterogenous hardware and finally suggests efficient device driver development.

  • PDF

Workpiece-Chucking Device Using Two-Way Shape Memory Alloys: Feasibility Test (양방향성 형상기억합금을 이용한 공작물 척킹장치: 유용성 검증)

  • Shin, Woo-Cheol;Ro, Seung-Kook;Park, Jong-Kweon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.5
    • /
    • pp.462-468
    • /
    • 2009
  • In this study, a workpiece-chucking device that generates a chucking force from a shape memory alloy is introduced. This paper first presents train procedure to transform a commercial one-way shape memory alloy into a two-way shape memory alloy, which makes unclamping mechanism of the chucking device simpler than that using the one-way shape memory alloy Second, it describes a conceptual design of the workpiece-chucking device using the two-way type shape memory alloy. Third, it presents a prototype and its chucking characteristics, such as time-response of clamping/unclamping operations and a relationship between temperatures and chucking forces. Finally, it describes a mill-machining test conducted with the prototype. The results confirm that the proposed workpiece-chucking device is feasible for micro machine-tools.

  • PDF

Development of an Integrated IoT System for Searching Dependable Device based on User Property (사용자 요소 기반의 신뢰성 있는 기기 탐색을 위한 사물인터넷 통합 시스템 개발)

  • Ryu, Shinhye;Kim, Sangwook
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.5
    • /
    • pp.791-799
    • /
    • 2017
  • With the development of the internet of things, sensor and device are can be applied to various scenario. Overall improving of the dependability index of internet of things is the ultimate goal. And reliability aims to increase the success rate of internet of things service delivery. Many studies about internet of things system have been made on the system to assess a dependability for providing reliable service to user, but it has difficult to reflect the user context for evaluating the device reliability. Also, most do not consider the availability of content information. In this paper, it proposed dependable device searching system in the internet of things environment. This system evaluates device dependability based on device status and measured data. Through the proposed system, it can be provided reliable context information for user-centric service.

A Clinical Study on the Repeatability and Reproducibility of Portable Ryodoraku Device (포터블 양도락의 반복성.재현성에 대한 임상 연구)

  • Lee, Ji In;Ko, Seong Cheol;Song, Ho Sueb
    • Journal of Acupuncture Research
    • /
    • v.30 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the repeatability and reproducibility of the Ryodoraku acupuncture device. For such device to be accepted as a good apparatus for clinical diagnosis, the score it provides should be stable no matter who measure it or when it is measured, assuming all other conditions equal. Materials and Methods : Three oriental medical doctors who were well trained and fully aware of the usage of the Ryodoraku acupuncture device examined ten randomly selected patients three times. Each doctor measured the Ryodoraku scores three times from each of the 10 selected patients. Three doctors were involved in this experiment to investigate the reproducibility and each of them measured the Ryodoraku scores three times from each patient to investigate the repeatability. Data was analyzed with Friedman test, Spearman correlation test, and intra-class correlation coefficient(ICC) in SPSS ver. 18. Results : 1. The Friedman test showed that there is no statistically significant difference between the 1st, 2nd and 3rd Ryodoraku scores measured by the same examiner. It indicates that the Ryodoraku acupuncture device provides the repeatability. 2. Spearman correlation test confirmed the results obtained by the Fiedman test by showing that there exists a strong positive correlation between the three Ryodoraku scores measured by the same examiner. 3. A very high ICC among the three examiner assured that the Ryodoraku acupuncture device achieves the reproducibility. Conclusions : The Ryodoraku acupuncture device achieves the repeatability and reproducibility. However, we still recommend that a doctor trained to a certain level use the Device to carry out the diagnosis. Also, to improve the device in terms of Reproducibility even more, it should be considered to provide a manual for the exact usage.

A Mobile Device Description Language (모바일 단말 정보 표현 언어)

  • Kim, Tae-Hyun;Lee, Seung-Yun;Lee, Kang-Chan;Lee, Won-Suk;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.811-814
    • /
    • 2007
  • Mobile device will be able to use the various contents from the advancement of the wireless Internet and mobile device manufacture technique. Each devices HTTP headers about under using provides terminal information to contents provider which is provided the contents which is suitable in device. But there is not a standard for a terminal information proηsion and when using the contents of service network outside, interoperability problems mobile communication it will provides terminal information in different method. International Organization for Standard OMA UAProf about under using it solved interoperability problems from outside. But about under using it provides terminal information, MMS support and Smart Card support, against an external storage space supporting information it is not seen clearly UAProf not to be, it will not be able to provide terminal information which is complete. This paper hereupon it designed UAProf in base which provides the contents which has become optimize to the mobile device of domestic environment the mobile device description language which expresses device information which is necessary.

  • PDF

ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements (일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로)

  • Sang Min, Park;Gyu Ha, Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

Design of a New Haptic Device using a Parallel Mechanism with a Gimbal Mechanism

  • Lee, Sung-Uk;Shin, Ho-Chul;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2331-2336
    • /
    • 2005
  • This paper proposes a new haptic device using a parallel mechanism with gimbal type actuators. This device has three legs actuated by 2-DOF gimbal mechanisms, which make the device simple and light by fixing all the actuators to the base. Three extra sensors are placed at passive joints to obtain a unique solution of the forward kinematics problem. The proposed haptic device is developed for an operator to use it on a desktop in due consideration of the size of an average Korean. The proposed haptic device has a small workspace for on operator to use it on a desktop and more sensitivity than a serial type haptic device. Therefore, the motors of the proposed haptic device are fixed at the base plate so that the proposed haptic device has a better dynamic bandwidth due to a low moving inertia. With this conceptual design, optimization of the design parameters is carried out. The objective function is defined by the fuzzy minimum of the global design indices, global force/moment isotropy index, global force/moment payload index, and workspace. Each global index is calculated by a SVD (singular value decomposition) of the force and moment parts of the jacobian matrix. Division of the jacobian matrix assures a consistency of the units in the matrix. Due to the nonlinearity of this objective function, Genetic algorithms are adopted for a global optimization.

  • PDF

A New Policy Study on Technical Document Review Changes and User-Centric Medical Device Advertising (사용자 중심의 의료기기 광고를 위한 기술문서 심사 변경의 새로운 정책 연구)

  • Ahn, Dae Ik;Ryu, Gyu Ha
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.7-17
    • /
    • 2021
  • In the case of domestic medical device advertisements, it is possible to proceed with the advertisement after medical device certification, and pre-deliberation is possible based on the medical device technical document. However, there are some medical device advertisements that stakeholders in administrative procedures have no choice but to misunderstand in customs and laws that do not consider users. In addition, medical equipment and the pre-deliberation system were judged to be unconstitutional, and unconstitutional decisions were made in accordance with the principle of prohibiting pre-censorship based on the Constitution. This is because in domestic medical device advertisements, structural contradictions and user damage occur in the central structure of each stakeholder. It is necessary to reestablish stakeholder relationships, increase water solubility from customs and laws, and seek new policy proposals. In this study, we reestablish relationships with stakeholders by applying the Autopoiesis theory, and present the grounds and directions that can prevent hype and misidentified advertisements through the establishment of user-centered policies, and the measures to be taken by the Constitutional Court unconstitutional decision.

Fault Isolation for Linux Device Drivers

  • Son, Sunghoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.4
    • /
    • pp.1-8
    • /
    • 2017
  • In this paper, we propose a fault isolation system for device drivers of the Linux operating system. High availability systems impose stringent requirements upon Linux operating system. Especially device drivers can be a major source of operating system instability and many times contribute to system degradation and outages. The proposed fault isolation system identifies the occurrence of the memory-related faults in device driver and isolates it from the kernel. By operating at the early stage of the page fault handler in Linux kernel, the system detects which module causes fault and isolates it transparently from the remaining part of the kernel. By experiments, we show that the proposed system efficiently detects faults incurred by device driver, isolates the device driver and the process which accessed the driver module from the kernel.