• Title/Summary/Keyword: IT Device

Search Result 12,035, Processing Time 0.045 seconds

Evaluation of compensator to reduce thermal sensation in oncological hyperthermia (고주파 온열암 치료 시 열감감소를 위해 자체 제작한 보상체의 유효성 평가)

  • Lee, Yeong Cheol;Kim, Sun Myung;Jeong, Deok Yang;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Objectives: Oncological hyperthermia is a treatment to selectively kill cancer cells by directly applying heat to cancer cells or indirectly demage cancer cells. One of the most side effects of treatment is burn that can appear on the skin. In areas with irregularities such as the umbilicus, the patient feels a sense of hot and treatment may be discontinued. Therefore, in order to eliminate the irregularities of these areas, compensators are manufactured and measured to decrease in temperature. Materials and Methods: The temperature of the four sites (umbilicus, near the umbilicus, 5 cm below the umbilicus, back) was measured five times around the umbilicus in patients who were treated at oncological hyperthermia treatment device(EHY-2000, Oncotherm Kft, Hungary). The temperature sensor (TM-100, Oncotherm Kft, Hungary) was attached to four sites and the changes were observed at 5, 15, 25, 35, and 50 minutes after treatment. Compensators of three materials were used(Vaseline, Bolus, Dental resin). The data measured five times were compared for each compensator. Results: The temperature change when the compensator was not used increase from 34.65 degrees to 42.9 degrees on average. The near umbilicus was changed from 32.20 degrees to 37.00 degrees, and the 5 cm below the umbilicus was changed from 31.90 to 34.41 degrees. When the compensator material was inserted into the umbilicus, the temperature change was measured as 5.42 degrees for bolus, 6.55 degrees for vaseline, and 6.83 degrees for resin. Conclusion: Using the compensator in the region where the irregularities such as the umbilicus, the heat sensation could be reduced. the use of a resin that can be customized not only lowers the temperature but also significantly reduces the feeling of the patient. It will be possible to reduce the heat sensation in the treatment and to treat it in a more comfortable condition.

  • PDF

Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer (소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구)

  • Lee, Hoon-Hee;Jung, Chang-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, a Small-sized and planer resonator design of Magnetic Resonance - Wireless Power Transfer(MR-WPT) were proposed for practical applications of mobile devices, such as a laptop, a smart-phone and a tablet pc. The proposed MR-WPT system were based on four coil MR-WPT and designed as a transmitter part (Tx) and a receiver part (Rx) both are the same shape with the same loop and resonator. There are four different spiral coil type of resonators with variable of line length, width, gap and turns in $50mm{\times}50mm$ size. The both of top and bottom side of substrate(acrylic; ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$) ere used to generate high inductance and capacitance in limited small volume. Loops were designed on the same plane of resonator to reduce their volume, and there are three different size. The proposed MR-WPT system were fabricated with two acrylic substrate plane of Tx and Rx each, the Rx and Tx loops and resonators were fabricated of copper sheets. There are 12 combinations of 3 loops and 4 resonators, each combination were measured to calculate transfer efficiency and resonance frequency in transfer distance from 1cm to 5cm. The measured results, the highest transfer efficiency was about 70%, and average transfer efficiency was 40%, on the resonance frequency was about 6.78 MHz, which is standard band by A4WP. We proposed small-sized and planer resonator of MR-WPT and showed possibility of mobile applications for small devices.

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Therapeutic compliance and its related factors in pediatrics patients (소아 환자의 치료 순응도 및 이에 영향을 미치는 요인)

  • Park, Ki Soo;Kam, Sin;Kim, Heung Sik;Lee, Jeong Kwon;Hwang, Jin-Bok
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.6
    • /
    • pp.584-596
    • /
    • 2008
  • Purpose : This study was conducted to investigate treatment compliance and related factors in pediatric patients. Methods : Three hundred and fifty-five patients diagnosed with various acute diseases at a teaching hospital or clinic in October 2003 were enrolled. Data were analyzed using the Health Belief Model, which includes items on self-efficacy and family assistance. Results : The study found that 62.9% of pediatric patients adhered faithfully to agreed-upon hospital revisits, 41.6% complied with dose timings instructions, 65.8% precisely took medication, and 27.2% complied with all of these requirements. According to ${\chi}^2$ test analysis, the factors found to be related to therapeutic compliance (the taking of medicines requested) were; susceptibility, severity, benefit, barriers, mother's self-efficacy, and family assistance (P<.05). Multiple logistic analysis and path analysis showed that susceptibility, severity, barriers, and mother's self-efficacy were related to therapeutic compliance (P<.05). Moreover, mother's self-efficacy was identified as the most important factor. Conclusion : To improve therapeutic compliance among pediatric patients, parental education is necessary, and a health care professional must take a thorough history of how the medication was taken before it is assumed that treatment failure is attributable to the medication prescribed. Furthermore, the type of device recommended for dosing should be determined by clinicians. In addition, it is important that pediatric medications be discussed in relation to their palatability and internal acceptability.

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

A study on the reduction on magnetic susceptible artifacts through the usage of silicon (실리콘을 이용한 자화율 인공물의 감소에 관한 연구)

  • Choi, Kwan-Woo;Lee, Ho-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5937-5942
    • /
    • 2012
  • This study used silicon that is similar to the density of the tissue of the human body to compensate for the uneven areas that are in contact with air in order to reduce susceptible artifacts. The subjects of the study were 16 normal people and the areas of the human body in which there are a lot of uneven areas with complicated structure and a lot of susceptible artifacts were formed since the surface area that comes into contact with the air is large were the areas that were chosen to be examined. A 3.0T superconducting magnetic resonance device was used as the test equipment and SPIR images that are sensitive to magnetic differences were obtained as sagittal planes on a line that extended the metatarsal and the phalanges, including the middle of the longitudinal arc and the 5 distal phalanxes. The method of analysis was to reduce the susceptibility between the tissue and the air to discover the reduction of susceptible artifacts by comparing the SNR and CNR before and after applying silicon. A statistical analysis was utilized for the sample matching T examination. The results of the study revealed that the susceptible artifacts were reduced in the images of the uneven areas that were compensated and applied with silicon. The SNR increased in significant amount in correlation from $3.91{\pm}1.33$ before application to $21.69{\pm}4.52$ after application and the CNR decreased in significant amount in correlation from $28.97{\pm}8.20$ before application to $4.88{\pm}2.14$. In conclusion, this study did not affect the voxel but it was an innovative method of improvement that compensated for the fundamental issue of the difference in susceptibility between the air and the body. The application is simple and the study has great significance in that it proposed a method to reduce susceptible artifacts in a low cost and highly efficient manner.

A study on the developmental plan of Alarm Monitoring Service (기계경비의 발전적 대응방안에 관한 연구)

  • Chung, Tae-Hwang;So, Seung-Young
    • Korean Security Journal
    • /
    • no.22
    • /
    • pp.145-168
    • /
    • 2010
  • Since Alarm Monitoring Service was introduced in Korea in 1981, the market has been increasing and is expected to increase continually. Some factors such as the increase of social security need and the change of safety consciousness, increase of persons who live alone could be affected positively on Alarm Monitoring Service industry. As Alarm Monitoring Service come into wide use, the understanding of electronic security service is spread and consumer's demand is difficult, so consideration about new developmental plan is need to respond to the change actively. Electronic security system is consist of various kinds of element, so every element could do their role equally. Alarm Monitoring Service should satisfy consumer's various needs because it is not necessary commodity, also electronic security device could be easily operated and it's appearance has to have a good design. To solve the false alarm problem, detection sensor's improvement should be considered preferentially and development of new type of sensor that operate dissimilarly to replace former sensor is needed. On the other hand, to settle the matter that occurred by response time, security company could explain the limit on Alarm Monitoring System to consumer honestly and ask for an understanding. If consumer could be joined into security activity by security agent's explanation, better security service would be provided with mutual confidence. To save response time the consideration on the introduction of GIS(Global Information System) is needed rather than GPS(Global Positioning System). Although training program for security agents is important, several benefits for security agents should be considered together. The development of new business model is required for preparation against market stagnation and the development of new commodity to secure consumer for housing service rather than commercial facility service. for the purpose of those, new commodity related to home-network system and video surveillance system could be considered, also new added service with network between security company and consumer for a basis is to be considered.

  • PDF

A Study on Family Planning Rumors & Practice in Rural Communities (일 농촌지역 가족계획 풍문과 실천에 관한 연구)

  • 추수경
    • Journal of Korean Academy of Nursing
    • /
    • v.8 no.2
    • /
    • pp.63-77
    • /
    • 1978
  • Studies pertaining to influential factors on adoption and practice of family planning are very much needed to lower fertility, for family planning has regarded as only one social acceptable means to curb the accelerated population growth. One of the influential factors is known as rumors on family planning methods that hinder the actual practice of family planning. This study generally aimed at disclosing rumors on family planning methods prevalent in rural communities so that one could gain some in sights to cope with the ill effects of rumors to promote family planning Practice in rural communities in Korea. In order to accomplish the general aims this study formulated following four specific objectives; 1. Find out types and frequencies of rumors exposed of contraceptive methods. 2. Find out the relationship between the rumors exposed and socio-economic and demographic characteristics of new village leaders and health workers. 3. Examine the relationship between family planing rumors and family planning practices. The materials for this study were drawn from the two different sets of data gathered in July and Octorber 1977 respectivily by Center for Population & family Planning, Yon sei University. One is current family planning practice among eligible women reaiding in 4 Myuns in Kwang Wha country and the other is Survey on Rumor on family planning method heard by new village leaders and health workers in the four myuns. The four Myuns were divided into 60 small areas. Current family planning practice rate in each small area and as a whole were calculated. The unit of analysis in this study was not the indviduel person but the 55 small areas. Percentage, average, F-Test t-test and a coefficient of correlation were used for statistical analysis. Results of this study could be summarized as follows: 1. Rumors by different method of contraception: Medical complications, gastro-intestinal disorders, and difficulty in usage one most prevalent rumors about oral pills. Around 49% -77% of the 55 areas were often heard and the most frequent rumor was related medical complications of oral pills. Rumors on medical complications and incomplete effect of intrauterines as contraceptive were heard 51-66% of the 55 small areas. Rumors that vasectomy resulted in family problems, for instance infiedelity of spouse were often heard to 44% of the 55 small areas. 2. Rumors by socio-economic and demographic characteristic of new village leader and health workers: Among the demographic characteristics such as sex, age and sex composition of children, sex and age differentials in frequency of rumors heard more observed, Female new village health workers have heard more frequently than male new village leader. (t = 7.137, p> 0.01, d.f. = 53, a coefficient of correlation 0.27, p>0.05) The Younger age group less than 40 years of age have heard rumors of than the group over 40 years old. (t = 7.18, p>0.01, d.f. = 53, a coefficient of correlation 0.27, p>0.05) However, it was not observable that a consistent sex and age differentials in frequency of rumors heard of each contraceptive mettled, But, more female new village health works heard of rumors about intrauterine device than male new village leaders. (t = 0.497, p> 0.01, d.f. = 53, a coefficient of correlatin 0.32, p>0.01) 3. It was found that there was no statistically significant relationship between the frequency of rumors heard and current family planning practices on the whole, However, frequency of rumors heard about vasectomy appeared to have a positive relationship with current practice of vasectomy. A rather consistent pattern of relationship between“requency of rumors heard”and current family practice rate was demonstrated of 10 graphes which showed the relation between the two variagles. The current family planning practice rate in the“never heard”group and “frequently heard”group was equally lower than that in“often heard”group. The relatively consistent ∩ pattern of relationship needs to be farther investigated, for this pattern is different from the relationship that has been assumed to exist between these two variables.

  • PDF