• Title/Summary/Keyword: IT Corporation

Search Result 4,914, Processing Time 0.036 seconds

Analysis of the effect from the Distribution Engineering Contest and course of improvement (배전기술 경진대회 발전방향 및 효과분석)

  • Lee, Won-Jung;Won, Tai-Seung;Kang, Gi-Nam;Lee, Sun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2228-2229
    • /
    • 2008
  • 한국전력공사에서는 신배전정보시스템(NDIS1)) 및 배전자동화(DAS2)) 활용능력 향상과 배전업무 우수인력 양성을 위하여 2004년부터 매년 배전기술경진대회를 치러오고 있으며 올해 제5회 대회를 맞이하고 있다. 따라서 2004년부터 현재까지 배전기술 경진대회의 발전 방향을 소개하고, 아울러 대회 신청자, 참가자 등 각종 데이터에 대한 이력관리를 통하여 결과를 분석하고 참가자에 대한 업무수행 능력 수준 및 평가요소별 강 약점을 제시하고 지역별, 연령별 수준분석을 통한 배전정책결정 기초 자료로 활용하고자 한다.

  • PDF

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Study on Application of Reinforcement Device to Provide Greater Dynamic Stability for Power Transmission Towers and its Effect

  • Yang, Kyeong-hyeon;Bae, Choon-hee;Jeong, Nam-geun;Kim, Doo-young;Kim, Sung-min;Jang, Yong-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.33-41
    • /
    • 2016
  • To verify that the friction damper used to high buildings as a kind of control technology of wind vibration can reduce dynamic behaviors of PTTs effectively, slip dampers in this paper are proposed to absorb the energy through relatively frictional movement of slip dampers applied to main post of a PTT (Power Transmission Tower) when dynamic displacement of a PTT occurs. The result of dynamic analysis is presented to determine the capacity of the damper system by controlling damping ratio on the resonance condition. It is observed that by installing slip dampers at a PTT the strain amplitudes of the main post caused by wind load are effectively reduced. Therefore it is shown that the proposed damper satisfies the strengthened wind-load design standards, and its efficacy was also validated experimentally by field testing.

Review on Evaluation of Rare Earth Metals and Rare Valuable Metals Contained in Coal Ash of Coal-fired Power Plants in Korea

  • Park, Seok-Un;Kim, Jae-Kwan;Seo, Yeon-Seok;Hong, Jun-Seok;Lee, Hyoung-Beom;Lee, Hyun-Dong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.121-125
    • /
    • 2015
  • Distribution of rare earth metals (REMs) and rare valuable metals (RVMs) contents in coal ashes (fly ash, bottom ash, and pond ash) and leachate from 11 coal-fired power plants in Korea were investigated. Coal ashes and leachates were found to contain important REMs and RVMs such as Yttrium (Y) and Neodymium (Nd), which was in the range of 23~75 mg/kg. However, it still requires developing effective recovery and separation methods in order to utilize REMs and RVMs in ash and leachate. Recovery of valuable elements (Y and Nd) from various and extensive ash sources (8.21 million tons/year in 2013) can provide the existing power plants with additional profit; therefore, it can significantly improve economics of the power plants.

Developing High-Performance Polymer Electrolyte Membrane Electrolytic Cell for Green Hydrogen Production (그린수소 생산을 위한 고성능 고분자 전해질막 전해조 개발 연구)

  • Choi, Baeck Beom;Jo, Jae Hyeon;Lee, Yae Rin;Kim, Jungsuk;Lee, Taehee;Jeon, Sang-Yun;Yoo, Young-Sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.137-143
    • /
    • 2021
  • As an electrochemical water electrolysis for green hydrogen production, both polymer electrolyte membrane (PEM) and alkaline electrolyte are being developed extensively in various countries. The PEM electrolyzer with high current density (above 2 A/cm2) has the advantage of being able to design a simple structure. Also, it is known that it has high response to electrical output fluctuations. However, the cost problem of major components is the most important issue that a PEM electrolyzer must overcome. Instantly, there are platinum group metal (PGM)-based electrocatalysts, fluorine-based polyfluoro sulfuric acid (PFSA) membrane, Ti felt (porous transport layer, PTL) and so on. Another challenging issue is productivity. A securing outstanding productivity brings price benefits of the electrolytic cells. From this point of view, we conducted basic studies on manufacturing electrode and membrane electrode assembly (MEA) for PEM electrolyzer production.

Multi-Valued Image Entropy Coding for input-width reduction of LCD source drivers

  • Sasaki, Hisashi;Arai, Tooru;Hachiuma, Masayuki;Masuko, Akira;Taguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.149-152
    • /
    • 2004
  • A new joint source channel coding reduces both input-width and average current consumption to transmit image data to LCD source drivers. As a source coding, it is based on entropy coding of differential pulse code modulation scheme, especially using median edge detector of image predictor. As a channel coding, it is not a simple pulse amplitude modulation, but linked by source entropy to reduce average amplitude. Simulation results show 1/4 width is achievable by 16-valued transmission with keeping conventional current consumption (0.36 to 1.3).

  • PDF

Automatic Algorithm for Cleaning Asset Data of Overhead Transmission Line (가공송전 전선 자산데이터의 정제 자동화 알고리즘 개발 연구)

  • Mun, Sung-Duk;Kim, Tae-Joon;Kim, Kang-Sik;Hwang, Jae-Sang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.73-77
    • /
    • 2021
  • As the big data analysis technologies has been developed worldwide, the importance of asset management for electric power facilities based data analysis is increasing. It is essential to secure quality of data that will determine the performance of the RISK evaluation algorithm for asset management. To improve reliability of asset management, asset data must be preprocessed. In particular, the process of cleaning dirty data is required, and it is also urgent to develop an algorithm to reduce time and improve accuracy for data treatment. In this paper, the result of the development of an automatic cleaning algorithm specialized in overhead transmission asset data is presented. A data cleaning algorithm was developed to enable data clean by analyzing quality and overall pattern of raw data.

Technical Feasibility Study on Live-line Maintenance Robot System for Overhead Distribution Lines (가공 배전선로 활선 정비 로봇 시스템의 기술 타당성 검토)

  • Joon-Young, Park;Yoon-Geon, Lee;Young-Sik, Jang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 2022
  • The distribution live-line work method is an operation method of working in a state in which electricity flows through overhead distribution lines to minimize inconvenience to electric customers due to power failure. In June 2016, to strengthen the safety of electrical workers, Korea Electric Power Corporation announced that it would in principle abolish the rubber glove method, in which workers wore protective equipment such as rubber gloves and performed their maintenance work. In addition, KEPCO announced that it would develop a short-range live working method using smart sticks and an advanced live-line maintenance robot system where workers work without touching wires directly. This paper is a preliminary study for the development of the live-line maintenance robot system, and deals with the results of analyzing the technical feasibility of whether the live works performed by workers can be replaced by robots or not.

Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy (신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법)

  • Ja-hyun, Baek;Hyeonjin, Kim;Soonho, Choi;Sangho, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.

Statistical Life Expectancy Calculation of MV Cables and Application Methods (중전압 전선의 통계적 수명예측 계산과 응용 방법)

  • Chong-Eun, Cho;On-You, Lee;Sang-Bong, Kim;Kang-Sik, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.61-68
    • /
    • 2022
  • In this paper, the change history of various types of MV (Medium Voltage) cables was investigated. In addition, the statistical life expectancy of each type was calculated by using the operation data and the failure data. For cut-off year, 10 years was applied, and realistically applicable statistical life expectancy was calculated by correcting the cause of failure entered by mistake. The life expectancy of FR-CNCO-W was calculated as 51.2 years, CNCV-W 38.1 years, and CNCV 31.4 years and the overall average is 33.8 years. Currently, the life expectancy of TR CNCV-W is 29.4 years, but it is estimated that the lifespan will be extended if failure data is accumulated. As a result, it is expected that life expectancy results can be applied to Asset Management System (AMS) in the future.