• 제목/요약/키워드: ISO Standard

검색결과 1,396건 처리시간 0.024초

The Physical, Mechanical, and Sound Absorption Properties of Sandwich Particleboard (SPb)

  • ISWANTO, Apri Heri;HAKIM, Arif Rahman;AZHAR, Irawati;WIRJOSENTONO, Basuki;PRABUNINGRUM, Dita Sari
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권1호
    • /
    • pp.32-40
    • /
    • 2020
  • While the utilization of wood as a raw material in related industries has been increasing with the population increasing, the availability of wood from natural forests has continued to decline. An alternative to this situation is the manufacture of particleboard from non-wood lignocellulose materials through the modification of sandwich particleboard (SPb) using bamboo strands as reinforcement. In this study, strandsof belangke bamboo (Gigantochloa pruriens W) and tali bamboo (Gigantochloa apus) were utilized. The non-wood particles included sugar palm fibers, cornstalk, and sugarcane bagasse. The board was made in a three-layer composition of the face, back, and core in a ratio of 1: 2: 1. The binder used was 8% isocyanate resin. The sheet was pressed at a temperature of 160℃ for 5 min under a pressure of 3.0 N/㎟. Testing included physical and mechanical properties based on the JIS A 5908 (2003) standard, while acoustic testing was based on ISO 11654 (1997) standards. The results showed that using bamboo strands as reinforcement has an effect on the mechanical and physical properties of SPb. Almost all the types of boards met the JIS A 5908 (2003) standards, with the exception of thickness swelling (TS) and internal bond (IB) parameters. Based on the thickness swelling parameter, the C-type board exhibited the best properties. Overall, the B-type board thatused a belangke bamboo strand for the surface and sugarcane bagasse as the core underwent the best treatment. Based on the acoustical parameter, boards using a tali bamboo strand for the surface and sugar palm fiber as the core (E-type board) exhibited good sound absorption properties.

TS 기반의 정보보호수준 평가 방법론 개발에 관한 연구 (A Study on the Evaluation Methodology for Information Security Level based on Test Scenarios)

  • 성경;김석훈
    • 한국정보통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.737-744
    • /
    • 2007
  • 조직의 정보보호 목표를 효율적이고 효과적으로 달성하기 위해서는 조직의 정보보호 수준을 정확히 평가하고 이를 개선시킬 방향을 제시하는 기준이나 평가모델이 필요하다. 또한 이를 위해 부문별 정보보호 수준을 평가하고 개선할 수 있는 평가지표나 기준이 필요하고 우리나라에서 적용 가능한 정보보호 시스템들의 평가방법론이 연구되어야 한다. 본 연구에서는 다양하고 복잡한 네트워크 보안성과 보안성능부분에 초점을 맞추어 네트워크 보안성을 평가하기 위해 필요한 평가 시스템들을 추출하고 이들 각각을 평가할 수 있는 체크리스트와 각 시스템들이 네트워크 보안성에 얼마만큼 기여하는지를 결정하여 네트워크 보안성을 평가할 수 있는 방법을 제시하였다. 또한 네트워크 보안성능을 평가할 수 있는 평가 모델과 테스트시에 필요한 테스트 시나리오를 제시하였다.

유비쿼터스 항만 물류 환경을 위한 스마트 태그 시스템의 설계 및 구현 (Design and Implementation of a Smart Tag System for Ubiquitous Port Logistics)

  • 조현태;백윤주
    • 한국정보통신학회논문지
    • /
    • 제11권8호
    • /
    • pp.1500-1510
    • /
    • 2007
  • 최근 물류의 양이 증가함에 따라 빠르고 정확한 물류처리가 요구되어 지고 있다. 특히, 광역 물류 환경에서 게이트웨이로서의 역활을 수행하는 항만에서의 물류처리는 무엇보다 중요하다. 본 논문에서는 항만에서 보다 신속, 정확한 물류 처리를 수행하기 위한 스마트 태그 시스템을 설계 및 구현한다. 스마트 태그 시스템은 사물의 정보를 인식하는 능동형 RFID, 컨테이너의 보안을 담당하는 전자봉인 장치, 그리고 사물의 위치를 파악 및 추적하는 RTLS 시스템으로 이루어져 있다. 물류 환경에서 사용되어는 인식 기술은 이종 시스템들에서 판독되어지므로 표준과의 호환성은 중요하다. 본 논문에서는 표준과의 호환성을 유지하는 방법을 소개하고 검증을 수행하였으며, 스마트 태그의 수명, 인식률 및 인식시간 등과 같은 시스템의 성능을 분석한다.

Post-fire test of precast steel reinforced concrete stub columns under eccentric compression

  • Yang, Yong;Xue, Yicong;Yu, Yunlong;Gong, Zhichao
    • Steel and Composite Structures
    • /
    • 제33권1호
    • /
    • pp.111-122
    • /
    • 2019
  • This paper presents an experimental work on the post-fire behavior of two kinds of innovative composite stub columns under eccentric compression. The partially precast steel reinforced concrete (PPSRC) column is composed of a precast outer-part cast using steel fiber reinforced reactive powder concrete (RPC) and a cast-in-place inner-part cast using conventional concrete. Based on the PPSRC column, the hollow precast steel reinforced concrete (HPSRC) column has a hollow column core. With the aim to investigate the post-fire performance of these composite columns, six stub column specimens, including three HPSRC stub columns and three PPSRC stub columns, were exposed to the ISO834 standard fire. Then, the cooling specimens and a control specimen unexposed to fire were eccentrically loaded to explore the residual capacity. The test parameters include the section shape, concrete strength of inner-part, eccentricity ratio and heating time. The test results indicated that the precast RPC shell could effectively confine the steel shape and longitudinal reinforcements after fire, and the PPSRC stub columns experienced lower core temperature in fire and exhibited higher post-fire residual strength as compared with the HPSRC stub columns due to the insulating effect of core concrete. The residual capacity increased with the increasing of inner concrete strength and with the decreasing of heating time and load eccentricity. Based on the test results, a FEA model was established to simulate the temperature field of test specimens, and the predicted results agreed well with the test results.

국내 도서관의 소장정보 관리 현황과 소장정보용 KORMARC의 개정 방안 (Current Status of Holdings Data in Korean Libraries and Proposal for Revision of KORMARC Format for Holdings Data)

  • 노지현;이은주
    • 한국도서관정보학회지
    • /
    • 제49권4호
    • /
    • pp.93-117
    • /
    • 2018
  • 소장정보용 KORMARC은 자원의 소장기관이나 소장위치는 물론이고, 복본 수나 연속간행물의 소장 권호 정보, 대출이나 복사, 이용조건 등 실질적인 이용에 필요한 데이터를 표현하고 상호 교환하기 위한 표준 형식이다. 이러한 소장정보는 자원의 소장여부 및 물리적인 위치를 정확하게 지시해 주고, 이를 도서관 간에 공유해야 할 필요성이 크게 증대하고 있는 오늘날 그 중요성이 더욱 커지고 있다. 그러나 소장정보용 KORMARC은 서지정보나 전거데이터용 KORMARC에 비해 활용도가 떨어지며, 국내 도서관들로부터 크게 주목을 받지 못하고 있는 상황이다. 본 연구에서는 (1) 최근 업데이트된 MARC21 Format for Holdings Data (Update No.26)를 비롯하여 도서관 소장정보 관련 표준 및 적용 사례를 분석하고, (2) 국내 도서관 및 종합목록 운영기관들의 소장정보 관리 동향 및 기술형식을 조사한 다음, (3) 이를 바탕으로 소장정보용 KORMARC의 개정 및 활용 방안을 제안하였다.

국방품질경영시스템 성공요인의 탐색 (An Exploratory Study on the Success Factors of Defence Quality Management System)

  • 박종훈;이상천
    • 산업경영시스템학회지
    • /
    • 제41권4호
    • /
    • pp.160-170
    • /
    • 2018
  • This paper is an exploratory study on the success factors of Defence Quality Management System (DQMS) which is the certification system granted by the military for improving the quality of munitions. DQMS is established by adding military requirements to the ISO standard, thus, we especially focus on the additional requirements to figure out success key factors of DQMS certification. The 51 additional requirements of Korean Defense Specification (KDS) are empirically investigated from 67 companies that acquired DQMS certification. Firstly, we conduct an independent t-tests on 51 additional requirements of KDS 0050-900-3 to determine if there is a difference between an easily certified company and a hard-to-certify company, and obtain 8 requirements such as 'Internal propagation of performance', 'Preparation of documented work instructions', 'Work instructions in the workplace', 'Documentation of equipment management', 'Inventory management', 'Packaging and identification', 'Guarantee of access to internal audit result for customers', 'Notification to the customer for improper product.' Secondly, we carry out an factor analysis to the 51 additional requirements for classification, and figure out that 4 requirements among the 8 requirements above mentioned are grouped together in the same factor. The 4 requirements are 'Preparation of documented work instructions', 'Work instructions in the workplace', 'Packaging and identification', and 'Guarantee of access to internal audit result for customers.' The result of this paper will provide useful information to the company preparing for DQMS.

국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교 (Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner)

  • 김부섭;김정호
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

The Effect of Occupational Noise Exposure on Serum Cortisol Concentration of Night-shift Industrial Workers: A Field Study

  • Zare, Sajad;Baneshi, Mohammad R.;Hemmatjo, Rasoul;Ahmadi, Saeid;Omidvar, Mohsen;Dehaghi, Behzad F.
    • Safety and Health at Work
    • /
    • 제10권1호
    • /
    • pp.109-113
    • /
    • 2019
  • Background: In both developed and developing countries, noise is regarded as the most common occupational hazard in various industries. The present study aimed to examine the effect of sound pressure level (SPL) on serum cortisol concentration in three different times during the night shift. Methods: This case-control study was conducted among 75 workers of an industrial and mining firm in 2017. The participants were assigned to one of the three groups (one control and two case groups), with an equal number of workers (25 participants) in each group. Following the ISO 9612 standard, dosimetry was adopted to evaluate equivalent SPL using a TES-1345 dosimeter. The influence of SPL on serum cortisol concentration was measured during the night shift. The serum cortisol concentration was measured using a radioimmunoassay (RIA) test in the laboratory. Repeated measure analysis of variance and linear mixed models were used with ${\alpha}=0.05$. Results: The results indicated a downward trend in the serum cortisol concentration of the three groups during the night shift. Both SPL and exposure time significantly affected cortisol concentration (p < 0.0001, p < 0.0001). Conversely, age and body mass index had no significant influence on cortisol concentration (p = 0.360, p = 0.62). Conclusion: Based on the obtained results, increasing SPL will lead to enhancement of serum cortisol concentration. Given that cortisol concentration varies while workers are exposed to different SPLs, this hormone can be used as a biomarker to study the effect of noise-induced stress.

Performance evaluation study of a commercially available smart patient-controlled analgesia pump with the microbalance method and an infusion analyzer

  • Park, Jinsoo;Jung, Bongsu
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.129-143
    • /
    • 2022
  • Background: Patient-controlled analgesia (PCA) has been widely used as an effective medical treatment for pain and for postoperative analgesia. However, improper dose errors in intravenous (IV) administration of narcotic analgesics from a PCA infusion pump can cause patient harm. Furthermore, opioid overdose is considered one of the highest risk factors for patients receiving pain medications. Therefore, accurate delivery of opioid analgesics is a critical function of PCA infusion pumps. Methods: We designed a microbalance method that consisted of a closed acrylic chamber containing a layer and an oil layer with an electronic balance. A commercially available infusion analyzer (IDA-5, Fluke Co., Everett, WA, USA) was used to measure the accuracy of the infusion flow rate from a commercially available smart PCA infusion pump (PS-1000, UNIMEDICS, Co., Ltd., Seoul, Korea) and compared with the results of the microbalance method. We evaluated the uncertainty of the flow rate measurement using the ISO guide (GUM:1995 part3). The battery life, delay time of the occlusion alarm, and bolus function of the PCA pump were also tested. Results: The microbalance method was good in the short-term 2 h measurement, and IDA-5 was good in the long-term 24 h measurement. The two measurement systems can complement each other in the case of the measurement time. Regarding battery performance, PS-1000 lasted approximately 5 days in a 1 ml/hr flow rate condition without recharging the battery. The occlusion pressure alarm delays of PS-1000 satisfied the conventional alarm threshold of occlusion pressure (300-800 mmHg). Average accuracy bolus volume was measured as 63%, 95%, and 98.5% with 0.1 ml, 1 ml, and 2 ml bolus volume presets, respectively. A 1 ml/hr flow rate measurement was evaluated as 2.08% of expanded uncertainty, with a 95% confidence level. Conclusion: PS-1000 showed a flow accuracy to be within the infusion pump standard, which is ± 5% of flow accuracy. Occlusion alarm of PS-1000 was quickly transmitted, resulting in better safety for patients receiving IV infusion of opioids. PS-1000 is sufficient for a portable smart PCA infusion pump.

해양플랫폼 알루미늄 핸드레일 적용을 위한 소켓 구조강도 평가법 (Methodology of Strength Analysis of Socket for AL Handrail in Offshore Platform)

  • 김연호;박주신;서정관
    • 해양환경안전학회지
    • /
    • 제28권2호
    • /
    • pp.354-360
    • /
    • 2022
  • 해양플랜트 상구구조물의 중량 절감을 위한 알루미늄 핸드레일 적용을 위하여, 소재의 항복강도 향상 및 관련 국제기준에 부합한 강도평가를 통하여 설계가 이루어지고 있다. 기존에 해양프로젝트에 설치된 알루미늄 핸드레일은 플랫폼에 설치 시 소켓에 볼트 연결되며, 소켓의 설계 정도에 따라서 핸드레일 처짐 량이 크게 좌우된다. 그러나 국제기준에서는 소켓에 대한 중요성 언급이 없으며, 별도의 평가 절차나 기준도 모호하다. 따라서 본 연구를 통해서 핸드레일 소켓 설계 시 고려해야 하는 주요 인자들에 대한 강도 해석을 수행하고, 최적의 치수를 도출하였다. 개발모델의 구조 안전성을 확보하기 위하여, 실험을 통한 검증을 수행하였고, 국제기준에서 요구하는 허용 처짐 이내에서 모두 만족함을 확인하였다. 개발된 국산화 모델은 기존 외국 제조사와 비교하여 가볍고, 생산성이 향상되어 향후 많은 분야에서 사용이 될 것으로 판단된다.